HomeMy WebLinkAboutA-106A - GENERAL NOTES FOR NEW WORK & NEW WORK PLAN NOTESGENERAL NOTES FOR NEW WORK
1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN
CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND WARRANTY
REQUIREMENTS.
2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL,
STATE, AND FEDERAL AUTHORITIES, RULES, REGULATIONS & CODES.
3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY
DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS SHALL BE
BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION.
4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL
EXISTING MATERIALS, SURFACES, & EQUIPMENT TO REMAIN.
5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS
NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM DUST,
VIBRATIONS AND WATER DAMAGE.
6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE
ARCHITECT AND OWNER PRIOR TO PROCEEDING WITH WORK.
7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED MATERIAL,
EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR RETENTION, SHALL
BECOME THE PROPERTY OF THE CONTRACTOR. LOAD DEMOLISHED
MATERIAL DIRECTLY ON TRUCKS OR INTO DUMPSTER, DISPOSE OF DEBRIS
LEGALLY. DO NOT BURN ON SITE. DO NOT ALLOW DEBRIS TO ENTER
SEWERS OR ROOF DRAINS. DO NOT LET PILED DEBRIS ENDANGER
STRUCTURE, BLOCK EXITS, OR ROADWAYS. UPON DISCOVERY OF ANY
HAZARDOUS MATERIALS, NOTIFY THE OWNER OF TYPE, LOCATION, AND
EXTENT OF SAME.
8. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY PERSONNEL
LICENSED IN THE STATE OF INDIANA IN ACCORDANCE WITH ALL LOCAL,
STATE, AND FEDERAL CODES.
9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, REQUIRED BY
ALL AGENCIES AND AUTHORITIES HAVING JURISDICTION FOR THE WORK
INCLUDED IN THIS CONTRACT. PERMIT SHALL BE CONSPICUOUSLY POSTED
AT JOB SITE.
10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS AND
METHODS OF JOB SITE SAFETY.
11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN
CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH SHEET
SHOULD NOT BE READ IN ISOLATION BY THE CONTRACTOR'S WORKMEN OR
HIS SUBCONTRACTORS.
12. ANY CONFLICTS IN THE DRAWINGS OR SPECIFICATIONS, OR BETWEEN
DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED
WITH WORK UNTIL WRITTEN CLARIFICATION OF CONFLICTS IS RECEIVED
FROM THE ARCHITECT.
13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST BE
MAINTAW ED THROUGHOUT NEW CONSTRUCTION, AND ANY PENETRATIONS
OR INTERRUPTIONS MADE TO THESE RATED SYSTEMS MUST BE REPAIRED TO
MAINTAIN RATING.
14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES,
FOR COORDINATION OF ALL TESTING AND INSPECTIONS NECESSARY, AND
FOR DELIVERY & STORAGE OF ALL MATERIALS NECESSARY TO COMPLETE
THE PROJECT.
15. THE CONTRACTOR SHALL CLEAN SITE AFTER CONSTRUCTION IN A MANNER
CONSISTENT WITH THE CONDITIONS THAT EXISTED PRIOR TO
CONSTRUCTION.
16. THE OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITIONS OF
EXISTING MATERIALS THAT ARE TO BE REMOVED OR DEMOLISHED.
NEW WORK PLAN NOTES
INDICATED ON DRAWINGS (TYPICALLY "SHADED" UNLESS OTHERWISE
NOTED). SEE WALL SCHEDULE FOR FRAMING TYPE, SIZE & GAGE. AT
FULL HEIGHT WALLS, FRAMING SHALL INCLUDE TOP AND BOTTOM
TRACKS WHICH SHALL BE BOLTED TO STRUCTURE @ CEILING &
FLOOR. AT PARTIAL HEIGHT WALL DIEWALLS, FRAMING SHALL BE
ATTACHED TO STRUCTURE AT FLOOR AND UNDERSIDE OF
COUNTERTOP ABOVE. PROVIDE AND INSTALL CONTINUOUS DOUBLE
STUDS AT DOOR JAMBS. REMOVE AREA OF CARPETING BELOW NEW
FLOOR TRACK PRIOR TO INSTALLATION OF FLOOR TRACK. TAPE AND
SPACKLE WALL SMOOTH FOR RECEIPT OF NEW VINYL WALL
COVERING. PROVIDE & INSTALL CONT. CORNER BEADS AT ALL
EXTERIOR GYP. BRD. CORNERS, TAPE ALL JOINTS BETWEEN GYP. BRD.
PANELS, SKIM COAT ALL GYP. BRD. SURFACES TP PROVIDE FLUSH,
SMOOTH, CRACK FREE SUBSTRATE (SEE FINISH INDEX FOR FINISH
MATERIAL). AREAS TO WCLUDE ALL GYP. BRD. WALLS, CEILINGS AND
BULKHEADS. COMPLY WITH ASTM C587. USE "DIAMOND FINISH
PLASTER" BY US GYPSUM CO. (312321-4000) OR EQUAL.
9.02 PROVIDE NECESSARY MATERIALS AND CONSTRUCT NEW 5l8" GYPSUM
WALLBOARD BULKHEAD. USE 3 5/8" MTL. STUD FRAMING SYSTEM,
MIN. 24 GA., FRAMING TO BE 16" O.C. MAX. EXTEND FR4MING ABOVE
CEILING & ANCHOR TO STRUCTURE ABOVE WITH CLIP ANGLES SET
INTO SLAB WITH POWDER DRIVEN FASTENERS. TAPE AND SPACKLE
BULKHEAD SMOOTH TO RECEIVE NEW THREE COAT PAINT SYSTEM.
PROVIDE & INSTALL CONT. CORNER BEADS AT ALL EXTERIOR GYP.
BRD. CORNERS, TAPE ALL JOINTS BETWEEN GYP. BRD. PANELS, SKIM
COAT ALL GYP. BRD. SURFACES TP PROVIDE FLUSH, SMOOTH, CRACK
FREE SUBSTRATE (SEE FINISH INDEX FOR FINISH MATERIAL). AREAS
TO INCLUDE ALL GYP. BRD. WALLS, CEILINGS AND BULKHEADS.
COMPLY WITH ASTM C587. USE "DIAMOND FINISH PLASTER" BY US
GYPSUM CO. (312-321-4000) OR EQUAL.
9.07 CONTRACTOR TO INSTALL ALL NEW OWNER PROVIDED CARPETING
AND CARPET PAD (AS DESIGNED / SELECTED BY CAUHAUS INC., PER
SEAMING DIAGRAMS BY MANUFACTURER). CONTRACTOR / INSTALLER
SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS
PROVIDED BY "MARRIOTT INC." FOR INSTALLATION OF CARPETING
/PADDING SYSTEMS. AT CARPET INSTALLATIONS OVER AREAS OF
SEVERELY DAMAGED OR UN-EVEN FLOORING CONTRACTOR SHALL
PROVIDE AND INSTALL SKIM COAT OF "LATICRETE 816 - RAPID
UNDERLAYMENT" OVER 100 % OF DAMAGED OR UN-EVEN FLOOR
SURFACE. INSTALL UNDERLAYMENT PER ALL REQUIRED
SPECIFICATIONS OF "LATICRETE SYSTEMS". NEW CARPETING SHALL
BE CONTINUOUS UNDER OVERHANGS & OPEN COUNTERS &
CASEWORK. CARPETMG SHALL NOT RUN UNDERNEATH BUILT-IN
BANQUETTE SEATING.
�
4: STONE
4.01 CONTRACTOR SHALL PROVIDE & INSTALL NEW STONE COUNTER TOPS
& BACKSPLASH WHERE INDICATED IN FABRICATION OR OTHER
DRAWINGS. FULLY ADHERE TOPS TO STABLE SUBSTRATES, FULLY
ADHERE BACKSPLASH TO GYP. BRD. SUBSTRATES. TYPICAL EDGE g.� �
DETAIL IS SQUARE WITH EASED EDGES. PROVIDE & INSTALL
CONTINUOUS CLEAR SILICONE BEAD AT ALL STONE INTERSECTIONS,
AND BETWEEN STONE AND V.W.0 OR OTHER WALL FINISH.
7: THERMAL & MOISTURE PROTECTION
7.01 TYPICAL AT ALL WALL COVERING INSTALLATIONS: PROVIDE & INSTALL
CONTINUOUS JOINT SEALANT AT THE INTERSECTION OF NEW VINYL
WALLCOVERING AND ALL OTHER MATERIALS / SURFACES, MCLUDMG
BUT NOT LIMITED TO: CEILMGS, BULKHEADS, DOOR FRAMES,
ELEVATOR FRAMES, FIRE EXTINGUISHER CABIN ETS, SURFACE
MOUNTED & RECESSED HEATING UNITS, MASONRY WALLS,
THERMO-PLASTIC WALL COVERING. TYPICAL: USE ONE-PART NON-SAG
ACRYLIC LATEX TYPE SEALANT COMPLYING WITH ASTM C834, COLOR
TO MATCH WALL SURFACE, BY "TREMCO / 216-292-5000" OR EQUAL. AT
TOP OF VENDING ROOM TILE BASE / WALLCOVERING USE MILDEW
RESISTANT, ONE PART, SILICONE SEALANT "786 - DOW CORNING CORP
/ 517-496-4000" OR EQUAL FOLLOW ALL MANUFACTURERS
RECOMMENDATIONS.
8: DOORS & HARDWARE & WINDOWS & GLASS
8.03 PROVIDE & INSTALL NEW 1 3/4" X 3'-0" X 7'-0" SOLID WOOD CORE
DOUBLE SWING PRE-FINISHED TRAFFIC DOOR WITH HIGH PRESSURE
LAMINATE ON BOTH SIDES, BY "CHASE" DOORS (CONTACT: MIKE
HAIDINGER / CHASE DOORS / 800-543-4455 X-2917 / 800-245-7045 FAX.).
CONTRACTOR SHALL VERFIY SIZE & FIT OF PROPOSED DOOR IN FIELD
PRIOR TO PURCHASE, TO ASSURE PROPER FIT AND INSTALLATION.
PROVIDE & INSTALL "KITCHEN CLASSIC - RETRO DINER SERIES -MODEL
NUMBER "KC 5026" W/ CONCEALED PIVOTS, BY "CHASE DOORS" IN
"NEVAMAR/ MATTE BLACK" LAMINATE FORMICA ON BOTH SIDES, WITH
12" ROUND SHATTER RESISTANT CLEAR ACRYLIC VISION PANEL SET IN
BLACK RUBBER MOLDING (60" A.F.F. TO CENTER), WITH 8" SATIN ST.
STL. KICK PLATE (BOTH SIDES). ALL EDGES SHALL BE COVERED WITH
ST. STL. EDGE TRIM (T.M.KICK PL.). PROVIDE AND INSTALL ALL
ASSOCIATED HARDWARE, ACCESSORIES AND ANCHORS AS PROVIDED
& REQUIRED BY "CHASE DOORS". PROVIDE PRODUCT DATA OF EACH
DOOR TYPE & SHOP DRAWINGS SHOWING FABRICATION AND
INSTALLATION DETAILS FOR REVIEW BY ARCHITECT (PRIOR TO
PURCHASE). INSTALL PER MANUFACTURERS REQUIRED MEANS &
METHODS FOR INSTALLATION.
8.07 CONTRACTOR SHALL PROVIDE & INSTALL GLASS DOOR AND / OR
WINDOW FILM ON WINDOWS INDICATED ON I.D. DRAWINGS. WINDOW
FILM T.B.D.
8.08A CONTRACTOR SHALL PROVIDE & INSTALL NEW STAIN GRADE DOORS
NEW 2" H.M. FRAME TO COORDINATE WITH NEW DOORS AND
HARDWARE. DOORS SHALL BE PREPPED FOR HARDWARE AND
STAINED & SEALED, H.M. FRAME SHALL RECEIVE THREE COAT
PAINTED FINISH.
8.11 PROVIDE & INSTALL NEW PTD. 2" WELDED H.M. FRAME WITH DOOR
STOPS(SEE WALLSCHEDULEFOR WALLTHICKNESS/
CONSTRUCTION). PRE-PRIME FRAME TO RECEIVE MIN. TWO FINISH
COATS IN FIELD. PROVIDE AND INSTALL JAMB AND BASE ANCHORS,
TO ANCHOR FRAME TO NEW STUD FRAMING. PROVIDE AND INSTALL
MINIMUM FOUR JAMB ANCHORS PER SIDE USING #6 SELF TAPPING
SCREWS, 3/8" MIN. MORTISE FRAME TO RECEIVE NEW DOOR HINGES,
AND PROVIDE OPENING FOR DOOR STRIKE. CONTRACTOR SHALL
PROVIDE & INSTALL BACK TO BACK DOUBLE VERTICAL MTL STUD AT
ALLFRAMEJAMBS.
5.12
CONTRACTOR SHALL PROVIDE AND INSTALL NEW AUTOMATIC GLASS
"-'N DOORS TO INCLUDE DOORS, MOTOR,
RELEA5E0 FOR CONSTRUCTION .ESHo�o.
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
Cityof Carmel �P. BRD. FINISH WALLS TO THE EXTENT
`�yc,��,'.�" �,�:;valol„1��.
DATE: 06�30�20
9.13
PROVIDE AND INSTALL NEW PORCELAIN FLOOR TILE, SEE DRAWINGS FOR
LAY-OUT, SIZES AND EXTENT. RUN FLOORING TILES UNDERNEATH
OVERHANGS, OPEN COUNTERS, CASEWORK & BANQUETTES.
PROVIDE & APPLY "MAPEI -MAPELASTIC 315 CRACK ISOLATION
MEMBRANE ON SUBSTRATES UNDERNEATH ALL NEW TILE WORK. SET
TILES TO SUBSTRATE WITH "MAPEI - THINSET MORTAR. GROUT
JOINTS FULL WITH "STAR QUARTZ - QUARTZ LOCK" GROUT,
NON-STAINING, ANTI-BACTERIAL GROUT (OR EQ.). MAXIMUM JOINT
SIZE TO BE 3/16". CLEAN ALL HAZE AND GROUT FROM TILE SURFACE
WITH APPROVED CLEANER. SEE FINISH SCHEDULE FOR TILE TYPE,
COLOR AND FINISH. CONTRACTOR SHALL SUBMIT GROUT COLOR
SAMPLES FOR SELECTION IAPPROVAL PRIOR TO INSTALLATION.
MAINTAIN & RE-INSTALL EXISTING FLOOR JUNCTION BOXES, COVERS.
COORDINATE INSTALLATION WITH ADJACENT FLOORING TO PROVIDE
CONTINUOUS, FLUSH FLOOR SURFACE. SEE FINISH SCHEDULE FOR
SPECIFIC MATERIAL SELECTIONS.
CONTRACTOR SHALL SUPPLY AND INSTALL NEW WOOD WALL BASE TO
MATCH EXISTING WOOD WALL BASE IN HEIGHT, THICKESS, AND
PROFILE , WHERE INDICATED ON DRAWINGS. CONTRACTOR SHALL
REMOVE SMALL ADJACENT WALL BASE PIECES, WHERE NECESSARY,
TO PROVIDE SEAMLESS, CONTINUOUS WALL BASE PIECES.
INSTALLATION TO BE WITH RECESSED FINISH NAILS.
CONTRACTOR SHALL SUPPLY AND INSTALL NEW VINYL BASE WHERE
INDICATED ON DRAWINGS. INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
9.14 CONTRACTOR SHALL PROVIDE AND INSTALL ALL TYPICAL & ACCENT
VINYL WALLCOVERING ON ALL EXISTING & NEW GYP. BRD. WALLS
(UNLESS OTHER FINISH IS SPECIFIED). PREP 100°/ OF WALL
SUBSTRATES TO PROVIDE SMOOTH, CONTINUOUS, ADHESIVE AND
DIRT FREE SURFACE TO RECEIVE NEW WALL COVERING.
CONTRACTOR/INSTALLER SHALL ASSURE THAT THERE ARE NO
VERTICAL SEAMS WITHIN 6" OF ANY CORNERS AND NO HORIZONTAL
SEAMING. SEE FINISH SCHEDULE FOR WALL COVER TYPES,
LOCATIONS, WIDTHS, REPEATS AND ROLL SIZES.
CONTRACTOR/WSTALLER SHALL ADHERE TO ALL SPECIFICATIONS
FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR
INSTALLATION OF VINYL WALLCOVERING SYSTEMS.
9.18 CONTRACTOR SHALL PROVIDE & INSTALL NEW MTL. FRAMING LINTEL
OVER OPENING FOR DOOR SIZES INDICATED ON DRAWINGS. SEE
WALL SCHEDULE FOR FRAMING TYPE, SIZE & GAGE. LINTEL SHALL
MATCH ADJACENT WALLS IN THICKNESS, TYPE & GA..
9.19 CONTRACTOR TO INSTALL NEW WOVEN VINYL FLOORING AND
COORDINATING UNDERLAYMENT WHERE INDICATED ON DRAWINGS.
INSTALL PER MANUFACTURER'S INSTRUCTIONS.
9: PAINTING AND STAINING FINISHES
9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS, EXISITNG
WOOD MILLWORK, WOOD PIERS, WOOD BASE AND WOOD TRIM
SURFACES TO PROVIDE NICK & SCRATCH FREE, CONSISTENT STAIN
COLOR AND TONE SURFACES, TREATMENT NOT TO EXCEED 50°/ OF
ALL SURFACES. TREAT ALL SURFACES WITH LIGHT MINERAL SPIRIT
SOLVENT TO REMOVE DIRT, DUST AND GREASE. ALLOW DOORS TO
DRY, AND LIGHTLY SAND WITH "FINAL STRIPPWG PADS", CLEAN
RESIDUE WITH "TACK CLOTH". TOUCH UP DOOR SURFACES AND
EDGES WITH MATCHING STAIN COLOR. FILL NICKS AND DENTS WITH
MATCHING WOOD PUTTY, SMOOTHED AND SANDED TO BE FWSH.
APPLY A COAT OF CLEAR SATIN MINWAX "POLYACRYLIC PROTECTIVE
FINISH" USE A FOAM APPLICATOR TYPE BRUSH, ALLOW 8 HOURS TO
DRY. DOOR LEVER HARDWARE TO REMAIN IN PLACE DURING
REFINISHING, PROTECT DOOR HARDWARE FROM RECEIVING STAIN OR
FINISH.
9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH
COATS) TO ALL GYP. BRD. / PLASTER FINISH CEILINGS (SEE RNISH
SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER
SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS
PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING
SYSTEMS.
9.53 PROVIDE AND APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER &
TWO FINISH COATS) TO ALL ACCESS PANELS, GRILLES, LOUVERS,
RADIATORS & METAL HVAC COVERS. PROVIDE SMOOTH, GREASE AND
DUST FREE SURFACE TO RECEIVE PAINT SYSTEM. (SEE FINISH
SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR I INSTALLER
SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS
PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING
SYSTEMS.
9.54 PROVIDE AND APPLY NEW PAINTING SYSTEM (PRIMER & TWO FINISH
COATS) TO H.M. DOORS, AND I OR H.M. DOOR FRAMES, ALL EXPOSED
SURFACES (SEE FINISH SCHEDULE FOR COLORS AND SHEEN).
PROVIDE SMOOTH, GREASE AND DUST FREE SURFACE TO RECEIVE
PAINT SYSTEM. CONTRACTOR / INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC."
FOR APPLICATION OF PAINTING SYSTEMS.
9.55 PROVIDE AND APPLY NEW PAINTING SYSTEM (PRIMER & TWO FINISH
COATS) TO WOOD DOOR FRAMES NOTED TO BE PAINTED OR ALREADY
PAINTED. ALL EXPOSED SURFACES (SEE FINISH SCHEDULE FOR
COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO
ALL SPECIFICATIONS FOR WSTALLATION AS PROVIDED BY "MARRIOTT
INC." FOR APPLICATION OF PAINTING SYSTEMS.
9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH
COATS) TO ALL ALREADY PAINTED GYP. BRD. / PLASTER FINISH WALLS,
SOFFITS, & BULKHEADS (SEE FINISH SCHEDULE FOR COLORS AND
SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC."
FOR APPLICATION OF PAINTING SYSTEMS.
11: EQUIPMENT
11.03 FLAT SCREEN TELEVISION (EXISTING / RELOCATED): CONTRACTOR
SHALL REINSTALL FLAT SCREEN TELEVISIONS & TELEVISION
MOUNTWG DEVICES, WHERE INDICATED ON DRAWINGS, W LOCATIONS
WHERE THEY HAVE BEEN TEMPORARILY REMOVED OR RELOCATED IN
ORDER TO PROVIDE SPACE TO CONSTRUCT NEW WORK, IN
ACCORDANCE WITH NEW CONSTRUCTION DRAW WGS. CONTRACTOR
SHALL PROVIDE ALL NECESSARY IN WALL BLOCKING TO SUPPORT TV
& TV MOUNTING BRACKET IF EXISTING CONDITIONS DO NOT PROVIDE
ADEQUATE SUPPORT. CONTRACTOR SHALL PROVIDE ALL NECESSARY
ELECTRICAL CONNECTIONS REQUIRED FOR OPERATION I
INSTALLATION OF EQUIPMENT. CONTRACTER SHALL COORDINATE
RE-INSTALLATION WITH NEW & EXISTING WALL AND/OR CEILING
FINISHES. CONTRACTOR SHALL COORDINATE WITH PROPERTY & HELP
TO I NSTALL AN D CON N ECT CABLE W I RI N G SYSTEMS TO ALL
TELEVISIONS.
12: FURNISHINGS & FF&E
12.01 CONTRACTOR SHALL ASSIST PROPERTY IN INSTALLATION OF ALL
OWNER PROVIDED FF&E ITEMS.
12.02 CONTRACTOR SHALL INSTALL ALL OWNER PROVIDED WALL MOUNTED
FRAMED MIRRORS & ARTWORK WITH HARDWARE & SECURITY
ANCHORS PROVIDED BY ARTWORK /MIRROR SUPPLIER. LOCATIONS
TO BE AS PER DRAWINGS, TO BE VERIFIED IN FIELD WITH DIRECTION
BY DESIGNER. CONTRACTOR SHALL VERIFY AND INSURE THAT
ADEQUATE BLOCKING AND SUPPORT BE PROVIDED FOR ALL ITEMS
BEING HUNG FROM WALLS.
12.05 CONTRACTOR SHALL INSTALL OWNER-PROVIDED ROLLER SHADE WITH
BLACKOUTAND SHEER SHADES WITH SIDE TRACKS, AND ALL
ASSOCIATED HARDWARE, BY OWNER. CONTRACTOR TO CONFIRM
ADEQUATE SUPPORT BLOCKING BEFORE INSTALLATION OF WINDOW
SHADES.INSTALLSHADES PER MANUFACTURERSINSTALLATION
INSTRUCTIONS.
15: MECHANICAL / PLUMBING
15.01 (NOT IN USE)
16: ELECTRICAL / LIGHTING
16.01 PROVIDE & INSTALL NEW OUTLETS AND COVER PLATES AT ALL
POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS, AND PHONE
JACKS. COLOR TO BE WHITE.
16.02
`�x�x3
PROVIDE AND INSTALL NEW EDGE LIT EXIT SIGNS AS REQUIRED (SEE
ELECTRICAL DRAWINGS).
(NOT IN USE)
16.06 CONTRACTOR SHALL INSTALL ALL "OWNER PROVIDED" DECORATIVE
LIGHTING IN ACCORDANCE WITH LIGHT FIXTURE SCHEDULE AND / OR
FF&E SPECIFICATION MANUAL (SEE ELECTRICAL DRAWINGS AS WELL).
CONTRACTOR SHALL COORDINATE INSTALLATION WITH NEW
CEILWGS, DUCTWORK, GRILLES, AN EQUIPMENT, AND ALL OTHER
CEILWG ELEMENTS. CONTRACTOR SHALL VERIFY COMPATIBILITY OF
ALL FIXTURES WITH PROPOSED CEILING TYPE (GYP. BRD., A.T.C.,
ETC.), AND SHALL PROVIDE ALL NECESSARY STRUCTURAL SUPPORTS
/ BLOCKING TO SUPPORT DECORATIVE FIXTURES (WEIGHTS TO BE
PROVIDED BY FABRICATORS).
Q
L
N
N -
c
ai� ���
Q _ � o
'O o�'��
Y
yT,,.. �:.
coNsu�r�rvrs
N
�
�
U
� C
��
O =
U"
�
WU
G-' m
� c
O �
c
m
W c m `V
W wb�
Z q � ui
3 -m
� u d �
W Ni�^
�
�
�
J (n
FQ�M
OaZo
WZa�
UQ�Z
Zp��
cai�zgw
(�_��
WO�U
�Z�
w
U
Z
� Q J
c!) w
��
Q o
Z
w
�
HRCMITEQ'$ $EAL
J g�yq'�•,�
sicreEa ;,�J`o'
': a
aE�EnsEOFoa�
❑ PRELIMINARY ONLY
❑ aioowc
�vEamirs
❑ CONSTROCTION
onre�.oanuzozo
aao�ecrNo: sasz
oanwN, �w
oesicrven �w
cHECK:reo
sHEET,i,�e.
GENERAL NOTES FOR NEW
WORK 8 NEW WORK PLAN
NOTES
SHEET NO'
A.106A