HomeMy WebLinkAboutA-107A - GENERAL NOTES FOR NEW WORK & NEW WORK PLAN NOTESGENERAL NOTES FOR NEW WORK
1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN
CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND
WARRANTY REQUIREMENTS.
2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE
LOCAL, STATE, AND FEDERAL AUTHORITIES, RULES, REGULATIONS
& CODES.
3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY
DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS
SHALL BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S
ATTENTION.
4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO
PROTECT ALL EXISTING MATERIALS, SURFACES, & EQUIPMENT TO
REMAIN.
5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS
NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM
DUST, VIBRATIONS AND WATER DAMAGE.
6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE
REPORTED TO THE ARCHITECT AND OWNER PRIOR TO
PROCEEDING WITH WORK.
7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED
MATERIAL, EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR
RETENTION, SHALL BECOME THE PROPERTY OF THE
CONTRACTOR. LOAD DEMOLISHED MATERIAL DIRECTLY ON
TRUCKS OR INTO DUMPSTER, DISPOSE OF DEBRIS LEGALLY. DO
NOT BURN ON SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS
OR ROOF DRAINS. DO NOT LET PILED DEBRIS ENDANGER
STRUCTURE, BLOCK EXITS, OR ROADWAYS. UPON DISCOVERY OF
ANY HAZARDOUS MATERIALS, NOTIFY THE OWNER OF TYPE,
LOCATION, AND EXTENT OF SAME.
8. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY
PERSONNEL LICENSED IN THE STATE OF INDIANA IN ACCORDANCE
WITH ALL LOCAL, STATE, AND FEDERAL CODES.
9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS,
REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING
JURISDICTION FOR THE WORK INCLUDED IN THIS CONTRACT.
PERMIT SHALL BE CONSPICUOUSLY POSTED AT JOB SITE.
10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS
AND METHODS OF JOB SITE SAFETY.
11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN
CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH
SHEET SHOULD NOT BE READ IN ISOLATION BY THE
CONTRACTOR'S WORKMEN OR HIS SUBCONTRACTORS.
12. ANY CONFLICTS IN THE DRAWMGS OR SPECIFICATIONS, OR
BETWEEN DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT
TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE
CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN
CLARIFICATION OF CONFLICTS IS RECEIVED FROM THE
ARCHITECT.
13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST
BE MAINTAINED THROUGHOUT NEW CONSTRUCTION, AND ANY
PENETRATIONS OR INTERRUPTIONS MADE TO THESE RATED
SYSTEMS MUST BE REPAIRED TO MAINTAIN RATING.
14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL
TRADES, FOR COORDINATION OF ALL TESTING AND INSPECTIONS
NECESSARY, AND FOR DELIVERY & STORAGE OF ALL MATERIALS
NECESSARY TO COMPLETE THE PROJECT.
15. THE CONTRACTOR SHALL CLEAN SITE AFTER CONSTRUCTION IN A
MANNER CONSISTENT WITH THE CONDITIONS THAT EXISTED
PRIOR TO CONSTRUCTION.
16. THE OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITIONS
OF EXISTING MATERIALS THAT ARE TO BE REMOVED OR
DEMOLISHED.
NEW WORK PLAN NOTES
7: THERMAL & MOISTURE PROTECTION
7.01 TYPICAL AT ALL WALL COVERMG INSTALLATIONS: PROVIDE
& INSTALL CONTINUOUS JOINT SEALANT AT THE
INTERSECTION OF NEW VINYL WALLCOVERING AND ALL
OTHER MATERIALS / SURFACES, INCLUDING BUT NOT
LIMITED TO: CEILINGS, BULKHEADS, DOOR FRAMES,
ELEVATOR FRAMES, FIRE EXTINGUISHER CABIN ETS,
SURFACE MOUNTED & RECESSED HEATING UNITS,
MASONRY WALLS, THERMO-PLASTIC WALL COVERING.
TYPICAL: USE ONE-PART NON-SAG ACRYLIC LATEX TYPE
SEALANT COMPLYING WITH ASTM C834, COLOR TO MATCH
WALL SURFACE, BY "TREMCO / 216-292-5000" OR EQUAL. AT
TOP OF VENDING ROOM TILE BASE / WALLCOVERING USE
MILDEW RESISTANT, ONE PART, SILICONE SEALANT'786 -
DOW CORNING CORP I 517-496-4000" OR EQUAL FOLLOW
ALLMANUFACTURERS RECOMMENDATIONS.
8: DOORS & HARDWARE & WINDOWS & GLASS
8.08A CONTRACTOR SHALL PROVIDE & INSTALL NEW STAIN
GRADE DOORS NEW 2" H.M. FRAME TO COORDINATE WITH
NEW DOORS AND HARDWARE. DOORS SHALL BE PREPPED
FOR HARDWARE AND STAINED & SEALED, H.M. FRAME
SHALL RECEIVE THREE COAT PAINTED FINISH.
8.11 PROVIDE & INSTALL NEW PTD. 2" WELDED H.M. FRAME WITH
DOOR STOPS (SEE WALL SCHEDULE FOR WALL THICKNESS
/ CONSTRUCTION). PRE-PRIME FRAME TO RECEIVE MIN.
TWO FINISH COATS IN FIELD. PROVIDE AND INSTALL JAMB
AND BASE ANCHORS, TO ANCHOR FRAME TO NEW STUD
FRAMING. PROVIDE AND INSTALL MINIMUM FOUR JAMB
ANCHORS PER SIDE USING #6 SELF TAPPING SCREWS, 3/8"
MIN. MORTISE FRAME TO RECEIVE NEW DOOR HINGES,
AND PROVIDE OPENING FOR DOOR STRIKE. CONTRACTOR
SHALL PROVIDE 8, INSTALL BACK TO BACK DOUBLE
VERTICAL MTL. STUD AT ALL FRAME JAMBS.
9: FINISHES & WALL FRAMING
9.07 CONTRACTOR TO INSTALL ALL NEW OWNER PROVIDED
CARPETING AND CARPET PAD (AS DESIGNED / SELECTED
BY CAUHAUS INC., PER SEAMING DIAGRAMS BY
MANUFACTURER). CONTRACTORIINSTALLERSHALL
ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS
PROVIDED BY "MARRIOTT INC." FOR INSTALLATION OF
CARPETING /PADDING SYSTEMS. AT CARPET
INSTALLATIONS OVER AREAS OF SEVERELY DAMAGED OR
UN-EVEN FLOORWG CONTRACTOR SHALL PROVIDE AND
INSTALL SKIM COAT OF "LATICRETE 816 - RAPID
UNDERLAYMENT" OVER 100°/ OF DAMAGED OR UN-EVEN
FLOOR SURFACE. INSTALL UNDERLAYMENT PER ALL
REQUIRED SPEGFICATIONS OF "LATICRETE SYSTEMS".
NEW CARPETING SHALL BE CONTINUOUS UNDER
OVERHANGS & OPEN COUNTERS & CASEWORK.
CARPETING SHALL NOT RUN UNDERNEATH BUILT-IN
BANQUETTE SEATING.
�
CONTRACTOR SHALL PROVIDE AND INSTALL ALL TYPICAL &
ACCENT VINYL WALLCOVERMG ON ALL EXISTING & NEW
GYP. BRD. WALLS (UNLESS OTHER FINISH IS SPECIFIED).
PREP 100% OF WALL SUBSTRATES TO PROVIDE SMOOTH,
CONTINUOUS, ADHESIVE AND DIRT FREE SURFACE TO
RECEIVE NEW WALL COVERING. CONTRACTOR/INSTALLER
RELEA5E0 FOR CONSTRUCTION RE ARE "o veRncn� senMs
RS AND NO HORIZONTAL
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�y,:a���'.�`� �,�:;vaYa/„1��.
DATE: 06�30�20
SEAMING. SEE FINISH SCHEDULE FOR WALL COVER TYPES,
LOCATIONS; WIDTHS, REPEATS AND ROLL SIZES.
CONTRACTORIINSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC" FOR INSTALLATION OF VINYL
WALLCOVERING SYSTEMS.
9: PAINTING AND STAINING FINISHES
9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS,
EXISITNG WOOD MILLWORK, WOOD PIERS, WOOD BASE
AND WOOD TRIM SURFACES TO PROVIDE NICK & SCRATCH
FREE, CONSISTENT STAIN COLOR AND TONE SURFACES,
TREATMENT NOT TO EXCEED 50% OF ALL SURFACES.
TREAT ALL SURFACES WITH LIGHT MINERAL SPIRIT
SOLVENT TO REMOVE DIRT, DUST AND GREASE. ALLOW
DOORS TO DRY, AND LIGHTLY SAND WITH "FINAL STRIPPING
PADS", CLEAN RESIDUE WITH "TACK CLOTH". TOUCH UP
DOOR SURFACES AND EDGES WITH MATCHING STAIN
COLOR. FILL NICKS AND DENTS WITH MATCHING WOOD
PUTTY, SMOOTHED AND SANDED TO BE FLUSH. APPLY A
COAT OF CLEAR SATIN MINWAX "POLYACRYLIC PROTECTNE
FINISH" USE A FOAM APPLICATOR TYPE BRUSH, ALLOW 8
HOURS TO DRY. DOOR LEVER HARDWARE TO REMAIN IN
PLACE DURING REFINISHING, PROTECT DOOR HARDWARE
FROM RECEIVING STAIN OR FINISH.
9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER &
TWO FINISH COATS) TO ALL GYP. BRD. / PLASTER FINISH
CEILINGS (SEE FINISH SCHEDULE FOR COLORS AND
SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS.
9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER &
TWO FINISH COATS) TO ALL ALREADY PAINTED GYP. BRD. /
PLASTER FINISH WALLS, SOFFITS, & BULKHEADS (SEE
FINISH SCHEDULE FOR COLORS AND SHEEN).
CONTRACTOR / WSTALLER SHALL ADHERE TO ALL
SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY
"MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS.
11: EQUIPMENT
11.05 CONTRACTOR SHALL ASSIST PROPERTY IN RE-LOCATING
EXISTING (EQUIPMENT) TO STORAGE LOCATION
DESIGNATED BY PROPERTY DURING CONSTRUCTION, AND
SHALL ASSIST PROPERTY IN MOVING (EQUIPMENT) TO
FINAL LOCAL UPON COMPLETION OF RENOVATION WORK.
15: MECHANICAL / PWMBING
15.01 (NOT IN USE)
16: ELECTRICAL / LIGHTING
16.01 PROVIDE & INSTALL NEW OUTLETS AND COVER PLATES AT
ALL POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS,
AND PHONE JACKS. COLOR TO BE WHITE.
16.02 PROVIDE AND INSTALL NEW EDGE LIT EXIT SIGNS AS
REQUIRED (SEE ELECTRICAL DRAWINGS).
16.03 (NOT IN USE)
16.04 (NOT IN USE)
16.06 CONTRACTOR SHALL INSTALL ALL "OWNER PROVIDED"
DECORATIVE LIGHTING IN ACCORDANCE WITH LIGHT
FIXTURE SCHEDULE AND / OR FF&E SPECIFICATION MANUAL
(SEE ELECTRICAL DRAWINGS AS WELL). CONTRACTOR
SHALL COORDINATE INSTALLATION WITH NEW CEILINGS,
DUCTWORK, GRILLES, A/V EQUIPMENT, AND ALL OTHER
CEILING ELEMENTS. CONTRACTOR SHALL VERIFY
COMPATIBILITY OF ALL FIXTURES WITH PROPOSED CEILING
TYPE (GYP. BRD., A.T.C., ETC.), AND SHALL PROVIDE ALL
NECESSARY STRUCTURAL SUPPORTS / BLOCKING TO
SUPPORT DECORATIVE FIXTURES (WEIGHTS TO BE
PROVIDED BY FABRICATORS).
Q
t
N
� -
c
d � � m n
O - � a
� N o� �'_
y
y�.,_.T�
cousu�,nrv,s
N
T
�
v
❑�
d' 9
O =
U "_
W c°�
� �
,� "
O d
� C q
W C R N
wwa�
Z � m
� .�. a�o
Z � E �
WNi�=
�
��
J (n
FQ�M
OzQ7
UQ�Z
Zp�
J
�z�w
(�_��
Z�rna
wO�U
�Z�
w
U
Z
� Q J
cn w
��
Q o
Z
w
�
ARCHITEQ'S SEAL
J 3A;q'�•,�
s.c.eeo`.�'1'0 ;
':�c
oYwio� ; * _
aE�EASEOFoa�
❑ PRELIMINARY ONLY
❑ 81�OING
�PEamirs
❑ CONSTROLTION
�ATE�.�3�]L2W�
PROJEQ NO.: 5353
oanww �w
oesi�rven �w
cnecrc-.rao
sHEErnr�e
GENERAL NOTES FOR NEW
WORK 8 NEW WORK PLAN
NOTES
SHEET NO[
A.107A