Loading...
HomeMy WebLinkAboutA-107A - GENERAL NOTES FOR NEW WORK & NEW WORK PLAN NOTESGENERAL NOTES FOR NEW WORK 1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND WARRANTY REQUIREMENTS. 2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL AUTHORITIES, RULES, REGULATIONS & CODES. 3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS SHALL BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION. 4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING MATERIALS, SURFACES, & EQUIPMENT TO REMAIN. 5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM DUST, VIBRATIONS AND WATER DAMAGE. 6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT AND OWNER PRIOR TO PROCEEDING WITH WORK. 7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED MATERIAL, EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR. LOAD DEMOLISHED MATERIAL DIRECTLY ON TRUCKS OR INTO DUMPSTER, DISPOSE OF DEBRIS LEGALLY. DO NOT BURN ON SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS OR ROOF DRAINS. DO NOT LET PILED DEBRIS ENDANGER STRUCTURE, BLOCK EXITS, OR ROADWAYS. UPON DISCOVERY OF ANY HAZARDOUS MATERIALS, NOTIFY THE OWNER OF TYPE, LOCATION, AND EXTENT OF SAME. 8. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY PERSONNEL LICENSED IN THE STATE OF INDIANA IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. 9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING JURISDICTION FOR THE WORK INCLUDED IN THIS CONTRACT. PERMIT SHALL BE CONSPICUOUSLY POSTED AT JOB SITE. 10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS AND METHODS OF JOB SITE SAFETY. 11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH SHEET SHOULD NOT BE READ IN ISOLATION BY THE CONTRACTOR'S WORKMEN OR HIS SUBCONTRACTORS. 12. ANY CONFLICTS IN THE DRAWMGS OR SPECIFICATIONS, OR BETWEEN DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION OF CONFLICTS IS RECEIVED FROM THE ARCHITECT. 13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST BE MAINTAINED THROUGHOUT NEW CONSTRUCTION, AND ANY PENETRATIONS OR INTERRUPTIONS MADE TO THESE RATED SYSTEMS MUST BE REPAIRED TO MAINTAIN RATING. 14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES, FOR COORDINATION OF ALL TESTING AND INSPECTIONS NECESSARY, AND FOR DELIVERY & STORAGE OF ALL MATERIALS NECESSARY TO COMPLETE THE PROJECT. 15. THE CONTRACTOR SHALL CLEAN SITE AFTER CONSTRUCTION IN A MANNER CONSISTENT WITH THE CONDITIONS THAT EXISTED PRIOR TO CONSTRUCTION. 16. THE OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITIONS OF EXISTING MATERIALS THAT ARE TO BE REMOVED OR DEMOLISHED. NEW WORK PLAN NOTES 7: THERMAL & MOISTURE PROTECTION 7.01 TYPICAL AT ALL WALL COVERMG INSTALLATIONS: PROVIDE & INSTALL CONTINUOUS JOINT SEALANT AT THE INTERSECTION OF NEW VINYL WALLCOVERING AND ALL OTHER MATERIALS / SURFACES, INCLUDING BUT NOT LIMITED TO: CEILINGS, BULKHEADS, DOOR FRAMES, ELEVATOR FRAMES, FIRE EXTINGUISHER CABIN ETS, SURFACE MOUNTED & RECESSED HEATING UNITS, MASONRY WALLS, THERMO-PLASTIC WALL COVERING. TYPICAL: USE ONE-PART NON-SAG ACRYLIC LATEX TYPE SEALANT COMPLYING WITH ASTM C834, COLOR TO MATCH WALL SURFACE, BY "TREMCO / 216-292-5000" OR EQUAL. AT TOP OF VENDING ROOM TILE BASE / WALLCOVERING USE MILDEW RESISTANT, ONE PART, SILICONE SEALANT'786 - DOW CORNING CORP I 517-496-4000" OR EQUAL FOLLOW ALLMANUFACTURERS RECOMMENDATIONS. 8: DOORS & HARDWARE & WINDOWS & GLASS 8.08A CONTRACTOR SHALL PROVIDE & INSTALL NEW STAIN GRADE DOORS NEW 2" H.M. FRAME TO COORDINATE WITH NEW DOORS AND HARDWARE. DOORS SHALL BE PREPPED FOR HARDWARE AND STAINED & SEALED, H.M. FRAME SHALL RECEIVE THREE COAT PAINTED FINISH. 8.11 PROVIDE & INSTALL NEW PTD. 2" WELDED H.M. FRAME WITH DOOR STOPS (SEE WALL SCHEDULE FOR WALL THICKNESS / CONSTRUCTION). PRE-PRIME FRAME TO RECEIVE MIN. TWO FINISH COATS IN FIELD. PROVIDE AND INSTALL JAMB AND BASE ANCHORS, TO ANCHOR FRAME TO NEW STUD FRAMING. PROVIDE AND INSTALL MINIMUM FOUR JAMB ANCHORS PER SIDE USING #6 SELF TAPPING SCREWS, 3/8" MIN. MORTISE FRAME TO RECEIVE NEW DOOR HINGES, AND PROVIDE OPENING FOR DOOR STRIKE. CONTRACTOR SHALL PROVIDE 8, INSTALL BACK TO BACK DOUBLE VERTICAL MTL. STUD AT ALL FRAME JAMBS. 9: FINISHES & WALL FRAMING 9.07 CONTRACTOR TO INSTALL ALL NEW OWNER PROVIDED CARPETING AND CARPET PAD (AS DESIGNED / SELECTED BY CAUHAUS INC., PER SEAMING DIAGRAMS BY MANUFACTURER). CONTRACTORIINSTALLERSHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR INSTALLATION OF CARPETING /PADDING SYSTEMS. AT CARPET INSTALLATIONS OVER AREAS OF SEVERELY DAMAGED OR UN-EVEN FLOORWG CONTRACTOR SHALL PROVIDE AND INSTALL SKIM COAT OF "LATICRETE 816 - RAPID UNDERLAYMENT" OVER 100°/ OF DAMAGED OR UN-EVEN FLOOR SURFACE. INSTALL UNDERLAYMENT PER ALL REQUIRED SPEGFICATIONS OF "LATICRETE SYSTEMS". NEW CARPETING SHALL BE CONTINUOUS UNDER OVERHANGS & OPEN COUNTERS & CASEWORK. CARPETING SHALL NOT RUN UNDERNEATH BUILT-IN BANQUETTE SEATING. � CONTRACTOR SHALL PROVIDE AND INSTALL ALL TYPICAL & ACCENT VINYL WALLCOVERMG ON ALL EXISTING & NEW GYP. BRD. WALLS (UNLESS OTHER FINISH IS SPECIFIED). PREP 100% OF WALL SUBSTRATES TO PROVIDE SMOOTH, CONTINUOUS, ADHESIVE AND DIRT FREE SURFACE TO RECEIVE NEW WALL COVERING. CONTRACTOR/INSTALLER RELEA5E0 FOR CONSTRUCTION RE ARE "o veRncn� senMs RS AND NO HORIZONTAL Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel `�y,:a���'.�`� �,�:;vaYa/„1��. DATE: 06�30�20 SEAMING. SEE FINISH SCHEDULE FOR WALL COVER TYPES, LOCATIONS; WIDTHS, REPEATS AND ROLL SIZES. CONTRACTORIINSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC" FOR INSTALLATION OF VINYL WALLCOVERING SYSTEMS. 9: PAINTING AND STAINING FINISHES 9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS, EXISITNG WOOD MILLWORK, WOOD PIERS, WOOD BASE AND WOOD TRIM SURFACES TO PROVIDE NICK & SCRATCH FREE, CONSISTENT STAIN COLOR AND TONE SURFACES, TREATMENT NOT TO EXCEED 50% OF ALL SURFACES. TREAT ALL SURFACES WITH LIGHT MINERAL SPIRIT SOLVENT TO REMOVE DIRT, DUST AND GREASE. ALLOW DOORS TO DRY, AND LIGHTLY SAND WITH "FINAL STRIPPING PADS", CLEAN RESIDUE WITH "TACK CLOTH". TOUCH UP DOOR SURFACES AND EDGES WITH MATCHING STAIN COLOR. FILL NICKS AND DENTS WITH MATCHING WOOD PUTTY, SMOOTHED AND SANDED TO BE FLUSH. APPLY A COAT OF CLEAR SATIN MINWAX "POLYACRYLIC PROTECTNE FINISH" USE A FOAM APPLICATOR TYPE BRUSH, ALLOW 8 HOURS TO DRY. DOOR LEVER HARDWARE TO REMAIN IN PLACE DURING REFINISHING, PROTECT DOOR HARDWARE FROM RECEIVING STAIN OR FINISH. 9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL GYP. BRD. / PLASTER FINISH CEILINGS (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL ALREADY PAINTED GYP. BRD. / PLASTER FINISH WALLS, SOFFITS, & BULKHEADS (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / WSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 11: EQUIPMENT 11.05 CONTRACTOR SHALL ASSIST PROPERTY IN RE-LOCATING EXISTING (EQUIPMENT) TO STORAGE LOCATION DESIGNATED BY PROPERTY DURING CONSTRUCTION, AND SHALL ASSIST PROPERTY IN MOVING (EQUIPMENT) TO FINAL LOCAL UPON COMPLETION OF RENOVATION WORK. 15: MECHANICAL / PWMBING 15.01 (NOT IN USE) 16: ELECTRICAL / LIGHTING 16.01 PROVIDE & INSTALL NEW OUTLETS AND COVER PLATES AT ALL POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS, AND PHONE JACKS. COLOR TO BE WHITE. 16.02 PROVIDE AND INSTALL NEW EDGE LIT EXIT SIGNS AS REQUIRED (SEE ELECTRICAL DRAWINGS). 16.03 (NOT IN USE) 16.04 (NOT IN USE) 16.06 CONTRACTOR SHALL INSTALL ALL "OWNER PROVIDED" DECORATIVE LIGHTING IN ACCORDANCE WITH LIGHT FIXTURE SCHEDULE AND / OR FF&E SPECIFICATION MANUAL (SEE ELECTRICAL DRAWINGS AS WELL). CONTRACTOR SHALL COORDINATE INSTALLATION WITH NEW CEILINGS, DUCTWORK, GRILLES, A/V EQUIPMENT, AND ALL OTHER CEILING ELEMENTS. CONTRACTOR SHALL VERIFY COMPATIBILITY OF ALL FIXTURES WITH PROPOSED CEILING TYPE (GYP. BRD., A.T.C., ETC.), AND SHALL PROVIDE ALL NECESSARY STRUCTURAL SUPPORTS / BLOCKING TO SUPPORT DECORATIVE FIXTURES (WEIGHTS TO BE PROVIDED BY FABRICATORS). Q t N � - c d � � m n O - � a � N o� �'_ y y�.,_.T� cousu�,nrv,s N T � v ❑� d' 9 O = U "_ W c°� � � ,� " O d � C q W C R N wwa� Z � m � .�. a�o Z � E � WNi�= � �� J (n FQ�M OzQ7 UQ�Z Zp� J �z�w (�_�� Z�rna wO�U �Z� w U Z � Q J cn w �� Q o Z w � ARCHITEQ'S SEAL J 3A;q'�•,� s.c.eeo`.�'1'0 ; ':�c oYwio� ; * _ aE�EASEOFoa� ❑ PRELIMINARY ONLY ❑ 81�OING �PEamirs ❑ CONSTROLTION �ATE�.�3�]L2W� PROJEQ NO.: 5353 oanww �w oesi�rven �w cnecrc-.rao sHEErnr�e GENERAL NOTES FOR NEW WORK 8 NEW WORK PLAN NOTES SHEET NO[ A.107A