Loading...
HomeMy WebLinkAboutA-108 - NEW CONSTRUCTION ENLARGED LOBBY LEVEL PLAN - RESTROOMSAT05UM � - -- -- ---- -- --------------------------�-�----------------- i�i � I % ,�, I i I � � 10.11 10.14 �7.01 9.14 9.53 15.0� 16A1 �7.01 9.14 9.53 15.021 16.01 � 25 RESTROOM 13B � : 8" 0.EAR MIN. 3._0. I"-J'-I" 0.EAR HO 7.02 ] 0.09 �(IYPJ -12.02 .� z_a i�a• 2�_i a�f o �.�. 9.01 � 10.09 (TYP.) �'� Vz° r s i/s" Y� i/z' r s i/s" f� i/z° rJ. o � 15.05 TYP. -12.02 � 10.09 0 0 (TYP � � � � �� -�� " -�r 8.10 10.13 (TYP.) W 26 'S RFcrRnnn� 0 0 � - - - � 6.03 I I5.05 I 7.02 15.03 Typ I TYP. I I 15.04 I TYP. I I _� L _ 1J ��__�� I 15I.04 I T`VP. 15.03 � TYP. I L - _ _ J 6.03 7.02 `��� SCALE:1/2" = 1'-0" GENERAL NOTES FOR NEW WORK 1. ALL WORK SHALL BE DONE IN WORKMAN LIKE MANNER AND IN CONFORMANCE WITH MANUFACTURER'S INSTALLATION AND WARRANTY REQUIREMENTS. 2. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL AUTHORITIES, RULES, REGULATIONS & CODES. 3. ALL DIMENSIONS AND FIELD CONDITIONS SHALL BE VERIFIED. ANY DISCREPANCIES IN DIMENSIONS, CONDITIONS, OR DOCUMENTS SHALL BE BROUGHT IMMEDIATELY TO THE ARCHITECT'S ATTENTION. 4. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING MATERIALS, SURFACES, & EQUIPMENT TO REMAIN. 5. CONTRACTOR SHALL BE LIABLE FOR, AND TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ALL EQUIPMENT AND BUILDING FROM DUST, VIBRATIONS AND WATER DAMAGE. 6. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT AND OWNER PRIOR TO PROCEEDING WITH WORK. 7. REMOVE ALL DEBRIS PROPERLY FROM SITE. ALL DEMOLISHED MATERIAL, EXCEPT THAT LISTED OR MARKED BY ARCHITECT FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR. LOAD DEMOLISHED MATERIAL DIRECTLY ON TRUCKS OR INTO DUMPSTER, DISPOSE OF DEBRIS LEGALLY. DO NOT BURN ON SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS OR ROOF DRAINS. DO NOT LET PILED DEBRIS ENDANGER STRUCTURE, BLOCK EXITS, OR ROADWAYS. UPON DISCOVERY OF ANY HAZARDOUS MATERIALS, NOTIFY THE OWNER OF TYPE, LOCATION, AND EXTENT OF SAME. 8. ALL ELECTRIC AND MECHANICAL WORK SHALL BE PROVIDED BY PERSONNEL LICENSED IN THE STATE OF INDIANA IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. 9. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, REQUIRED BY ALL AGENCIES AND AUTHORITIES HAVING JURISDICTION FOR THE WORK INCLUDED IN THIS CONTRACT. PERMIT SHALL BE CONSPICUOUSLY POSTED AT JOB SITE. 10. THE CONTRACTOR IS SPECIFICALLY RESPONSIBLE FOR ALL MEANS AND METHODS OF JOB SITE SAFETY. 11. CONTRACTOR SHALL ENSURE THAT NUMBER NOTES ARE READ IN CONJUNCTION WITH A NUMBER NOTE EXPLANATION, I.E., EACH SHEET SHOULD NOT BE READ IN ISOLATION BY THE CONTRACTOR'S WORKMEN OR HIS SUBCONTRACTORS. 12. ANY CONFLICTS IN THE DRAWINGS OR SPECIFICATIONS, OR BETWEEN DRAWINGS AND SPECIFICATIONS, SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION OF CONFLICTS IS RECEIVED FROM THE ARCHITECT. 13. ALL EXISTING RATED WALLS, FLOORS, CEILINGS, OR SHAFTS MUST BE MAINTAINED THROUGHOUT NEW CONSTRUCTION, AND ANY PENETRATIONS OR INTERRUPTIONS MADE TO THESE RATED SYSTEMS MUST BE REPAIRED TO MAINTAIN RATING. 14. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL TRADES, FOR COORDINATION OF ALL TESTING AND INSPECTIONS NECESSARY, AND FOR DELIVERY & STORAGE OF ALL MATERIALS NECESSARY TO COMPLETE THE PROJECT. RELEASEO FOR CONSTRUCTION 'LEAN SITE AFTER CONSTRUCTION IN A I THE CONDITIONS THAT EXISTED PRIOR Suhjec� �o compliance with all regula�ions o4S�a�eantlLocalCodes 2ESPONSIBILITYFORTHECONDITIONSOF Cityof Carmel ARE TO BE REMOVED OR DEMOLISHED. `�yc,��,'.�" �,�:;valol„1��. DATE: 06�30�20 NEW WORK PLAN NOTES 6: FABRICATIONS 6.03 CONTRACTOR SHALL FABRICATE 8 INSTALL NEW BATHROOM VANITY COUNTER. COMPONENTS SHALL INCLUDE THE FOLLOWING: 5/4" SQUARE EDGE STONE COUNTER AND STONE TURN-DOWN FACE AND BACKSPLASH ON THREE SIDES, AND WOOD VENEER APRON/PIPE COVER. PROVIDE STEEL ANGLE FRAME AT LEADING EDGE FOR COUNTER SUPPORT. ANCHOR VANITY STRUCTURE DIRECTLY TO WALL STRUCTURE. SEE MILLWORK DRAWINGS FOR DETAIL SIZES & DIMENSIONS. PROVIDE IN-WALL SOLID BLOCKING AT WALL ANCHOR POINTS. INSTALL ALL SPECIFIED PLUMBING FIXTURES AND COORDINATE AND INSTALL ALL REQUIRED PLUMBING CONNECTIONS, VAWES, P-TRAP, STACK VENT CONNECTIONS, ETC.. CAULK ALL JOINTS BETWEEN COUNTER & BACKSPLASHES, AND BETWEEN BACKSPLASHES AND WALL. 7: THERMAL & MOISTURE PROTECTION 7.01 TYPICAL AT ALL WALL COVERING INSTALLATIONS: PROVIDE & INSTALL CONTINUOUS JOINT SEALANTAT THE INTERSECTION OF NEW VINYL WALLCOVERING AND ALL OTHER MATERIALS I SURFACES, INCLUDING BUT NOT LIMITED TO: CEILINGS, BULKHEADS, DOOR FRAMES, ELEVATOR FRAMES, FIRE EXTINGUISHER CABW ETS, SURFACE MOUNTED & RECESSED HEATING UNITS, MASONRY WALLS, THERMO-PLASTIC WALL COVERING. TYPICAL: USE ONE-PART NON-SAG ACRYLIC LATEX TYPE SEALANT COMPLYING WITH ASTM C834, COLOR TO MATCH WALL SURFACE, BY "TREMCO I 216-292-5000" OR EQUAL. AT TOP OF VENDING ROOM TILE BASE / WALLCOVERING USE MILDEW RESISTANT, ONE PART, SILICONE SEALANT'786 - DOW CORNING CORP / 517-496-4000" OR EQUAL. FOLLOW ALL MANUFACTURERS RECOMMENDATIONS. 7.02 TYPICAL AT ALL PLUMBING FIXTURES & EDGES OF VANITY TOPS INCLUDED BUT NOT LIMITED TO TOILETS, SINKS, URINALS, FLOOR DRAINS & FAUCET SETS. PROVIDE & INSTALL CONTINUOUS SANITARY SEALANT AT THE INTERSECTION OF FIXTURE & FLOOR TILE, FIXTURE AND STONE COUNTERS, FIXTURE & WALL TILE, & ALL OTHER INTERSECTIONS. USE MILDEW RESISTANT, ONE PART, SILICONE RUBBER, IN CLEAR. USE ONE FO THE FOLLOWING: " 786 BY DOW CORNING CORP. 800-662-0661, "1700" BY GENERAL ELECTRIC CO 800-225-8886, OR "898" BY PECORA CORP. 800-923-6688 8: DOORS & HARDWARE & WINDOWS & GLASS 8.09 CONTRACTOR SHALL PROVIDE & INSTALL GLASS DOOR AND / OR WINDOW FILM ON WINDOWS INDICATED. WINDOW FILM TBD. 8.10 (ATRIUM BAHTROOMS) CONTRACTOR SHALL PROVIDE AND INSTALL NEW PAINT GRADE WOOD VENNER FRAME SWING DOORS WITH FLUSH STAINED WOOD INSET PANELS AND NEW 2" HM FRAME TO COORDINATE WITH NEW DOORS AND HARDWARE INCLUDING PRIVACY LEVER LOCK SET, DOOR SHALL BE PREPPED FOR HARDWARE AND STAINED 8 SEALED, HM FRAME SHALL RECEIVE THREE COAT PAINTED FINISH. 10.10 11 � ) I I 36x80 �� II 10 m� I I �2 P'� � � I I �� � - - d 0 � 10.09 (TYP. @ TOILET PAPER DISPENSERS) g 5'-21/4' I'-51/2" . 1'-5 _ s'-n'nreaunn 1/2• ��� �o ✓ (TYP.) � ]0.09 (TYP � GRAB P ME24ING ROOM = 1�A- 10.09 (TYP. L NAPKIN DI � � I 0.09 (TY P. @ TOI LET PAPER DISPENSERS) �i �� 9: FINISHES & WALL FRAMING 9.01 CONTRACTOR SHALL PROVIDE AND INSTALL NEW GTP BOARD FINISH WALLS TO THE EXTENT INDICATED ON DRAWINGS. SEE SCHEDULE FOR FRAMING TYPE, SIZE AND GAGE. FRAMING SHALL INCLUDE TOP AND BOTTOM TRACKS WHICH SHALL BE BOLYED TO STRUCTURE AT CEILING AND FLOOR. PROVIDE AND INSTALL CONTINUOUS DOUBLE STUDS AT DOOR JAMBS. REMOVE AREA OF CARPETING BELOW NEW FLOOR TRACK PRIOR TO INSTALLATION OF FLOOR TRACK. TAPE AND SPACKLE WALL SMOOTH FOR RECEIPT OF NEW VINYL WALL COVERING. PROVIDE & INSTALL CONT. CORNER BEADS AT ALL EXTERIOR GYP. BOARD. CORNERS, TAPE ALL JOINTS BETWEEN GYP. BOARD. PANELS, SKIM COAT ALL GYP. BOARD. SURFACES TP PROVIDE FLUSH, BETWEEN GYP. BOARD. PANELS, SKIM COAT ALL GYP. BOARD. SURFACES TP PROVIDE FLUSH, SMOOTH, CRACK FREE SUBSTRATE (SEE FINISH INDEX FOR FINISH MATERIAL). AREAS TO INCLUDE ALL GYP. BOARD. WALLS. CEILINGS AND BULKHEADS. COMPLY WITH ASTM C587. USE "DIAMOND FINISH PLASTER" BY US GYPSUM CO. (312321-4000) OR EQUAL. 9.14 CONTRACTOR SHALL PROVIDE & INSTALL ALL TYPICAL & ACCENT VINYL WALLCOVERING ON ALL EXISTING & NEW GYP. BRD WALLS (UNLESS OTHER FINISH IS SPECIFIED). PREP 100& OF WALL SUBSTRATE TO PROVIDE SMOOTH, CONTINUOUS, ADHESIVE AND DIRT FREE SURFACE TO RECEIVE NEW WALL COVERING. CONTRACTOR/ INSTALLER SHALL ASSURE THAT THERE ARE NO VERTICAL SEAMS WITHIN 6" OF ANY CORNERS, AN NO HORIZONTAL SEAMING, SEE FINISH SCHEDULE FOR WALL COVER TYPES, LOCATIONS, WIDTHS, REPEATS, AND ROLL SIZES. CONTRACTOR/ INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC" FOR INSTALLATION OF VINYL WALLCOVERING SYSTEMS. 9: PAINTING AND STAINING FINISHES 9.50 CLEAN AND TOUCH UP STAIN ALL WOOD FINISH DOORS, EXISITNG WOOD MILLWORK, WOOD PIERS, WOOD BASE AND WOOD TRIM SURFACES TO PROVIDE NICK & SCRATCH FREE, CONSISTENT STAIN COLOR AND TONE SURFACES, TREATMENT NOT TO EXCEED 50% OF ALL SURFACES. TREAT ALL SURFACES WITH LIGHT MINERAL SPIRIT SOWENT TO REMOVE DIRT, DUST AND GREASE. ALLOW DOORS TO DRY, AND LIGHTLY SAND WITH "FINAL STRIPPING PADS", CLEAN RESIDUE WITH "TACK CLOTH". TOUCH UP DOOR SURFACES AND EDGES WITH MATCHING STAIN COLOR. FILL NICKS AND DENTS WITH MATCHING WOOD PUTTY, SMOOTHED AND SANDED TO BE FLUSH. APPLY A COAT OF CLEAR SATIN MINWAX "POLYACRYLIC PROTECTIVE FINISH" USE A FOAM APPLICATOR TYPE BRUSH, ALLOW 8 HOURS TO DRY. DOOR LEVER HARDWARE TO REMAIN IN PLACE DURING REFINISHING, PROTECT DOOR HARDWARE FROM RECEIVING STAIN OR FINISH. 9.52 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL GYP. BRD. I PLASTER FINISH CEILINGS � : N.I.C. � � (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 9.53 PROVIDE AND APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL ACCESS PANELS, GRILLES, LOUVERS, RADIATORS BMETAL HVAC COVERS. PROVIDE SMOOTH, GREASE AND DUST FREE SURFACE TO RECEIVE PAINT SYSTEM. SEE FINISH SCHEDULE FOR COLORS AND SHEEN. CONTRACTOR / INSTALL SHALL ADHERE TO ALL SPECIFICATION FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 9.54 PROVIDE AND APPLY NEW PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO H.M. DOORS, ANDI OR H.M. DOOR FRAMES, ALL EXPOSED SURFACES (SEE FINISH SCHEDULE FOR COLOR AND SHEEN)/ PROVIDE SMOOTH, GREASE AND DUST FREE SURFACE TO RECEIVE PAINT SYSTEM. CONTRACTORI INSTALLAER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC" FOR APPLICATION OF PAINTING SYSTEMS. 9.58 APPLY NEW THREE COAT PAINTING SYSTEM (PRIMER & TWO FINISH COATS) TO ALL ALREADY PAINTED GYP. BRD. I PLASTER FINISH WALLS, SOFFITS, & BULKHEADS (SEE FINISH SCHEDULE FOR COLORS AND SHEEN). CONTRACTOR / INSTALLER SHALL ADHERE TO ALL SPECIFICATIONS FOR INSTALLATION AS PROVIDED BY "MARRIOTT INC." FOR APPLICATION OF PAINTING SYSTEMS. 10: SPECIALTIES 10.09 (PUBLIC RESTROOMS) CONTRACTOR SHALL RE-INSTALL EXISTING BRIGHTWORK IN SIMILAR AS EXISTING LOCATIONS. CONTRACTOR SHALL ENSURE ADEQUATE IN WALL BLOCKMG IN PROVIDED AT ALL GRAB BARS. 10.10 PROVIDE AND INSTALL NEW BATHROOM STALL DIVIDER PARTITIONS IN THEIR ENTIRERTY. PARTITIONS TO INCLUDE PARTITION, HARDWARE, AND ANCHORS. FOLLOW ALL OF THE MANUFACTURERS RECCOMENDATIONS AND REQUIREMENTS FOR INSTALLATION. CONTRACTOR/INSTALLER SHALL USE COMPATIBLE ANCHORS AND CONNECTORS SO AS NOT TO ALLOW FOR GALVANIC ACTION AND / OR RUST TO OCCUR BETWEEN MATERIALS. 10.11 CONTRACTOR SHALL PROVIDE AND INSTALL ALL NEW RECESSED PAPER TOWEL DISPENSER/ RECESSED TRASH CAN BY "BOBRICK" B-36903". FIXTURE SHALL BE OWNER SPECIFIEDI PROVIDED IN LOCATION INDICATED ON DRAWINGS. CONTRACTORTOINSTALLPER MANUFACTURERS SPECIFICATIONS. CONTRACTOR SHALL VERFIY AND ENSURE THAT ADEQUATE BLOCKING AND SUPPORT BE PROVIDED PER DETAILS. GENERAL ADA NOTES FOR NEW WORK 1. AT ACCESSIBLE STALLS: 604.8.1.2 DOORS. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH 404 EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 MCHES (1065 MM) MINIMUM. DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR OPENING SHALL BE 4 INCHES (100 MM) MAXIMUM FROM THE FRONT PARTITION. THE DOOR SHALL BE SELF-CLOSWG. A DOOR PULL COMPLYING WITH 40427 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. 2. AT AMBULATORY STALLS: 604.8.22 DOORS. TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH 404, EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 INCHES (1065 MM) MINIMUM. THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH 4042.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. 604.8.2.3 GRAB BARS. GRAB BARS SHALL COMPLY WITH 609. A SIDE-WALL GRAB BAR COMPLYING WITH 604.5.1 SHALL BE PROVIDED ON BOTH SIDES OF THE COMPARTMENT. 10.13 CONTRACTOR SHALL PROVIDE AND INSTALL NEW OWNER SPECIFIED/ PROVIDED TOILET PAPER DISPENSERS BY BOBRICK B-69991N LOCATION INDIACATED ON DRAWINGS. CONTRACTOR TO INSTALL PER MANUFACTURERS SPECIRCATIONS. CONTRACTOR SHALL VERIFY AND ENSURE THAT ADEQUATE BLOCKING AND SUPPORT BE PROVIDED PER DETAILS. 12: FURNISHINGS & FF&E 12.02 CONTRACTOR SHALL INSTALL ALL OWNER PROVIDED WALL MOUNTED FRAMED MIRRORS & ARTWORK WITH HARDWARE & SECURITY ANCHORS PROVIDED BY ARTWORK /MIRROR SUPPLIER. LOCATIONS TO BE AS PER DRAWINGS, TO BE VERIFIED IN FIELD WITH DIRECTION BY DESIGNER. CONTRACTOR SHALL VERIFY AND INSURE THAT ADEQUATE BLOCKING AND SUPPORT BE PROVIDED FOR ALL ITEMS BEING HUNG FROM WALLS. AT ADA LOCATION, MIRROR MUST BE MOUNTED SO THAT REFLECTIVE SURFACE IS 3'-4"A.F.F. MAX. 15: MECHANICAL / PLUMBING 15.02 (RESTROOMS) CONTRACTOR SHALL COVER & PROTECT EXISTING FLOOR DRAINS FROM DAMAGE, DUST AND DEBRIS FOR THE DURATION OF THE RENOVATION/ CONSTRUCTION WORK. 15.03 CONTRACTOR SHALL PROVIDE & WSTALL NEW DECK MOUNTED AUTOMATIC FAUCET IN LOCATIONS INDICATED. FACUETS TO BE SLOAN- EFX-200-500-000 BASYS SERIES SENSOR FAUCET (FOLLOW ALL MECHANICAU ELECTRICAL BUILDMG AND LOCAL JURISDICTION CODES) 15.04 CONTRACTORS SHALL PROVIDE d INSTALL NEW DECK MOUNTED AUTOMATIC FAUCETS IN LOCATIONS INDICATED. FAUCETS TO BE "SLOAN-EFX-200-500-000 BASYS SERIES SENSOR FAUCET" (FOLLOW ALL MECHANICAL / ELECTRICAL BUILDING AND LOCAL JURISDICTION CODES). 15.05 CONTRACTOR SHALL PROVIDE & INSTALL NEW DECK MOUNTED AUTOMATIC SOAP DISPENSERS IN LOCATIONS INDICATED. DISPENSERS TO BE: SLOAN-OPTIMA SOAP DISPENSER ESD-400-CP" (FOLLOW ALL MECHANICAL / ELECTRICAL BUILDING AND LOCAL JURISDICTION CODES). 16: ELECTRICAL / LIGHTING 16.01 PROVIDE & INSTALL NEW OUTLETS AND COVER PLATES AT ALL POWER , GFI, DATA, SWITCHING & DIMMER OUTLETS, AND PHONE JACKS. COLOR TO BE WHITE. NOTES (TYPICAL IN ALL SCOPE OF WORK): 9.50 9.52 9.58 16.01 Q % - � - a � � � a o ��� :� s��_ a�+ - ` y �, `-=�_ CONSULTAMS + � Ci � c K= O= U" c W ° U � c w '_ O a c m W c m v�i W w'v� Z q c � -m � « m � Z 2 � ^ W Vl U .M.. � ��� J (n O��O a WZ¢� UQ�Z Zp� J (�Z�w (�_�� Q WO�U �z� w u z ¢� ��w �� - o Q� Z W � ARCHITECTS SEAL J 1=,t : �,,.0 ,.� ; * �E6LNPilOIJ ae�enseoroa: ❑ PreEUMirvnav orv�r ❑aioowc � PEftMITS ❑ coNs�aucriory on.e.oansnozo GROJECTNO[5352 DRAWMLW DESIGNEO:LW cHECK�.reo SXEETTITLE- NEW CONSTRUCTION ENLARGEDLOBBVLEVELF RESTROOMS SHEETNO: A.108