HomeMy WebLinkAboutM-002 - MECHANICAL -NOTES AND SCHEDULESRELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
r
�un��V l�rc�alols�.
i
DATE: OF)�30�20
PLUMBING GENERAL NOTES:
1. ALLWORKSHALLCONFORMTOTHEINTERNATIONALPLUMBINGCODE-2015EDITIONAN�
ALL LOCAL CODES, RULES AND REGULATIONS INCLUDING THE AMERICANS WITH
DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES, OSHA ACTS AN� REGULATIONS, AND
THE RE�UIREMENTS OF THE LOCAL AUTHORITIES HAVING JURISDICTION.
2. THE CONTRACTOR SHALL OBTAIN ALL PERMITS. FEES, ANO LICENSES, ETC. REQUIRED TO
PERFORM THE WORK. THE CONTRAGTOR SHALL FURNISH AN� WSTALL NLL LABOR,
MATERIALANDEQUIPMENTTOPROVIDECOMPLETEANDOPERABLESYSTEMS. THE
WORK SHALL INCLUDE ANV INCIDENTAL ACCESSORIES NECESSARYTO MAKE THE WORK
COMPLETE IN ALL RESPECTS AND REA�Y FOR OPERATION.
3. WORKSHALLCONFORMTOSTANDARDINDl15TRYPRACTICES.ROl1TINGOFALLPIPING
AS SHOWN ON THE DRAWINGS IS DIAGRAMMATIC ONLY. INTENDING TO SHOW GENERAL
Rl1NS AND LOCATIONS OF PIPING, FIXTl1RE5 AND SPECIALTIES. IT IS NOTTHE IMENT OF
THESE DOCUMENTS TO INDICATE ALL OFFSETS AND FITTINGS REQUIRED. GENERALLY,
PIPING SHALL BE WSTALLED PARALLEL WITH OR PERPENDICULAR TO WALL
CONSTRUCTION. SUPPLV SVSTEMS SHALL BE INSTALLED LEVEL AND PLUMB, GRAVITY
SYSTEMS SHALL BE INSTqLLED WITH A UNIFORM SLOPE.
4. ALL PIPING SHOWN ON PLANS OR IN�ICATE� BV NOTES SHALL BE CONCEALED ABOVE
THE CEILING, LOCATE� BELOW THE FINISH FLOOR OR WNCEALE� IN WALLS OR CHASES,
UNLESS NOTED OTHERWISE.
5. THECONTRACTORSHALLVERIFYALLCONDITIONSBEFORESTARTINGTHEWORKAND
SHALL NOTIFY THE ARCHITECT IF A CONDITION EXISTS WHICH PREVENTS THE
GONTRACTOR FROM FCCOMPLISHING THE INTENT OF THE DRAWINGS. FAILURE TO
NOTIFY THE ARCHITECT IN A TIMELY MANNER SHALL MEAN THE CONTRACTOR HAS
PROCEEDED AT HIS OWN EXPENSE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE PLUMBING
WORK WITH ALL OTHER TRAOES, INC W DING STRUCTURAL, MECHANICAL, AND
ELECTRICAL WORK. THE CONTRACTOR SHALL PROVIDE NECESSARY OFFSETS,
TRANSITIONS, PIPE ROUTING, MATERIALS AND LABOR TO ARRANGE EQIIIPMENT AND
PIPING AS REQUIRED FOR A PROPER AND ACCESSIBLE INSTALLATION WITH MINIMAL
CONFLICT. CLOSE COORDINATION WILL BE RE�UIRED FOR ALL SERVICES.
7. DO NOT LOCATE PW MBING PIPINQ EQIIIPMENT, ETC., WER ELECTRICAL PANELS.
8. MATERIALS USED SHALL BE NEW ANO FlRST RATE IN QIIALITV. CARE SHALL BE TAKEN
WITH THE HANDLING AND SETTING OF ALL E�UIPMENT AND MATERIALS. ALL WORK SHALL
BE FREE FROM DEFECTS.
9. REFERENCETHEARCHITECTURALDRAWINGSFORDIMENSIONE�LOCATIONSOFWALLS,
PARTITIONS, PLUMBING FI%TURES AN� FOR PARTITION THICKNE55 AND CONSTRUCTION
MATERIALS. DRAWINGS SHALL NOT BE SCALED.
70. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVMG SCRAP MATERIALS AND
DEBRIS ASSOCIATED WITH THIS WORK FROM THE SITE.
11. PROVIDEFINALCONNECTIONSTOALLEQUIPMENTFURNISHEDBVTHEOWNERAND/OR
OTHERS.
72. PROVIDE ACCESS PANELS PoR ALL ITEMS REQIIIRING ACCESS OR MAIMENANCE
WGLUDING SHUT-OFF VALVES, WATER HAMMER ARRESTORS, BALANCING VALVES, ETC.
13. ALL PIPING AND MATERINLS USED IN A PLENUM SPNCE SHALL BE PLENUM RATED. THE
CONTRACTOR SHALL FlELD VERIFY EXTENT OF THE AREAS THAT ARE PLENUMS.
14. PIPE SIZES INDICATED ARE MINIMUM. IF A PIPING MATERIAL IS NOT MANUFACTURED OR
OTHERWISE AVAILABLE IN THE SIZE INDICATED THEN THE NEXT L4RGER PIPE SIZE SHALL
BE PROVIDED AND INSTALLED.
75. ALL EXPOSED WATER PIPING AND P-TRAPS SUBJECT TO FREEZING SHALL BE PROTECTED
BV INSULATION AND HEAT TAPE.
i6. CONTRACTORSHALLPROVIDECOORDINATIONDRAWINGS(MM.il4"SCALE)BEFORE
COMMENCE THEIR WORK. COORDINATION DRAWMGS SHALL INCW�E, BUT NOT LIMRED
T0. DUGTWORK, PIPING, WNDUITS LARGER THAN 2". E�UIPMENT, DEVICES THAT NEED
ACCESS. ALL DIMENSIONS SHOWN SHALL BE Ol1TSIDE DIMENSIONS. SIZES AND
ELEVATIONS OF TOP AND BOTTOM OF DUCTWORKIPIPES/EQUIPMENT SHALL BE CALLED
OUT ON COORDINATION DRAWINGS.
77. CONTRACTORSHALLSUBMITSHOPDRAWINGS,PRODUCTDATAANDSAMPLESTOTHE
ARCHITECT/ENGINEER FOR APPROVAL. WRITTEN SUBMITTALS SHALL BE FORWARDED IN
SIX (6) COPIES AND CLFARLY MARKED TO INDICATE SPECIFIC ITEM, PERFORMANCE OR
CAPACITIES, SRE, COLOR AND LOCATION OF USE. ALL SUBMRTALS SHALL BE CHECKED,
�ATE�,PRESENTE�AN�LFBELEDINACLEARAN�THOROUGHMANNER. SUBMITTALS
SHALLINCLUOE,BUTARENOTLIMITEDTO,THEFOLLOWING: PLUMBMGFIXTURES,
WSULATION. VALVES, HANGERS AND ALL PIPING AN� NCCESSORIES. ALL ITEMS LISTED
ON DRAWINGS AND/OR IN SPEQFlCATIONS ARE NOT IMENDED TO PREC W DE THE USE
OF OTHER PRODUGTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
MODIFICATIONS, REROUTING, RELOCATION AND VARIATIONS AT NO EXTRA COST TO THE
OWNER WHEN AND IF SUBSTITUTED ITEMS ARE APPROVED FOR USE. ALL WORK SHALL BE
PERFORMED IN ACCORDANCE WITH THE APPLICABLE STATE FN� LOCAL CODES, THE
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), THE ENVIRONMENTAL PROTECTION
AGENCv (EPA) AND THE LOCAL AUTHORITIES HAVING JURIS�ICTION.
PLUMBING SPECIFICATIONS:
GENERAC
1. THEWORKSHALLINCWDEPROVIDINGANDINSTALLINGALLMATERIALSINDICATEDTOPROVIDE
COMPLETE AND OPERABLE SYSTEMS. WORK SHALL TERMINATE AT A POINT FNE FEET FROM THE FACE
OF THE BUIL�ING, UNLESS NOTED OTHERWISE AN� SHALL INCLUDE CONNECTIONS TO SITE UTILITIES.
2 PROVIDEACCESSPANELSFORALLEQUIPMENTANDMATERIALSREQIIIRINGMAINTENANCEOR
INSPECTION INCLUDMG (BUT NOT LIMITED TO) VALVES, MOTORS, WATER HAMMER ARRESTORS,
3. PROVIDECUTTINGANDPATCHINGOFEXISTINGCONSTRUCTIONASREQUIREDTOINSTALLTHEWORK.
4. SUBMITTALS'.THECONTRACTORSHALLSUBMITALLPRODUCTDATAFORREVIEWANDACCEPTANCE
BV THE ENGMEER. THE CONTRACTOR SHALL BE PROCEEDING AT THEIR OWN RISK IF THE
CONTRACTOR CHOOSES TO PROCEED WITH THE WORK PRIOR TO ACCEPTANCE OF THE MATERIALS
AND E�UIPMENT BV THE ENGINEER.
PW MBING PIPING SVSTEMS'
5. REFERENCE THE PIPING MATERIAL SCHEDULE FOR PIPING MATERIALS.
fi. PROVIDE INSULATION FOR PIPING AND EQl11PMENTAS FOLLOWS:
DOMESTIC COLD WATER- 1" FIBERGLASS WITH ASJ
DOMESTIC HOT WATER- 1" FlBERGLASS WITH ASJ
HORIZONTAL RAINWATER CONDUCTORS (PRIMARV AND SECONOARY�- 1" FIBERGLASS WITH ASJ
VERTICAL RAINWATER CONDl1CTORS (PRIMARY AND SECONDARY) -1" FIBERGLASS WITH ASJ
ROOF DRAIN BODIES (PRIMARY AND SECONDARY) -1" FIBERGLA55 WITH FOIL FACE
WASTE PIPING FROM ELECTRIC WATER COOLERS OR CONDENSATE DRAWS (FIRST 10-FEET OF
DRAINAGE)- 1" FlBERGLASS WITH ASJ
7. DOMESTIC WATER SYSTEM VALVES: 2-PIECE, FULL-PORT BRASS BALL VALVES, NI8C0 S-FPLOON OR
NON-RISING STEM, FULLPORT BRASS GATE VALVES, NIBCO TI-8.
8. DOMESTIC HOT WATER RETl1RN SYSTEM BALANCING VALVES: BRASS GLOBE VALVES WITH TEST
PORTS, NIBCO 51710.
9. HANGERS: HANGERS, BRAGES AND RESTRAINTS SHALL ADEQUATELY SUPPORT THE SVSTEMS
HORIZONTALLY AND VERTICALLY AND SHALLALLOW FOR MOVEMENT WITHOl1TTRANSMITTING STRESS
OR VIBRATION TO THE STRUCTURE. HANGERS SHALL BE E�UAL TO GRINNELL PRODUCTS. HANGERS
ON INSULATED PIPING SHALL BE PROVIDED WITH AN� SHALL BE SIZED TO ACCOMMODATE INSULATION
INSERTS AN� HANGER SHIELDS.
10. HORIZONTALSOIL,WASTEANDVENTPIPINGHUNGFROMBUIL�INGCONSTRUCTIONSHALLBE
SUPPORTED AT NOT OVER 5 FEET NEXT TO FITTINGS. PROVIDE ADDITIONAL SUPPORTS AT JOINTS,
CHANGES IN DIRECTION AND ELSEWHERE AS RE�UIRED TO MAWTAIN PROPER ALIGNMENT.
11. PROVIDE ACRYLIC SNAP-ON LABELS WITH OIRECTIONAL ARROWS FOR ALL PLUMBING PIPING SYSTEMS.
LABELS SHALL BE SPACED A MAXIMUM OF 25'-0" APART AND WITHIN 2'-0" OF WALL PENETRATIONS.
12 PENETR4TIONS:ALLPIPINGPENETRATIONSOFRATE�ASSEMBLIESSHALLBESEALEDIN
ACW RDANCE WITH UL LISTED THROUGH PENETRATION ASSEMBLIES.
PLUMBING SPECIALTIES:
1. CLEANOUTS SHALL HAVE TOPS DESIGNED FOR SPEQFIC FLOOR FINISHES IN WHICH THEYARE
INSTALLED SUCH AS CARPET, TILE, ETC., UNLESS NOTED OTHERWISE.
2. QEANOUTS SHALL BE PROVIDED WITH TAPERED BRONZE PWGS.
3. WALL CLEANOUTS SHALL BE PROVIOED WITH ROUN� STAINLESS STEEL ACCESS COVERS.
PLUMBING FIXTURES:
L FIXTURES 8 TRIM: FIXTURES SHALL BE PROVIDEO IN ACCORDANCE WITH THE PROJECT
REQUIREMENTS. ASSEMBLIES SHALL BE COMPLETE AN� SHALL INCLUDE FIXTURES AN� ALL REQUIRED
APPURTENANCES, TRIM AND FlTTMGS TO PROVIDE A COMPLETE INSTALLATION. ALL FlXTURES SHALL
BE SEGURELV ANCHORED AN� FASTENED IN PLACE AND SHALL BE PLUMB AND LEVEL AND AT HEIGHTS
REQUIRED BY REFERENCED PLUMBING CODE, ACCESSIBILITY CO�E AND THE AMERICANS WITH
DISABILITIES ACCESSIBILITV GUIDELINES.
2. PROVIDESILICONCAULK(DOW-CORNING]841NTERIORSEALANTORE�VAL�ATTHEJOINTBETWEEN
PWMBING FlXTURES AND ADJACEM FLOORS. WALLS, ETC.
ADJUSTING AND START-UP:
1. THISCONTRACTORSHALLCLEANALLFIXTURES,ADJUSTALLVALVES,ANDLEAVETHESYSTEMIN
GOOD WORKING ORDER, REMOVE ALL DEBRIS AN� RUBBISH CAUSED BV HIS WORK, AND REPAIR ANv
DAMAGE CAUSED BY HIS WORKMAN.
2. ADJUSTMENT:THISCONTRACTORSHALLINCLUDEINHISBIDARETURNVISITTOTHESITEATATIME
TO BE DETERMINED, TO RE-ADJUST VALVES, AND CHECK FOR LEAKS AFTER THE SYSTEM HAS BEEN IN
OPERATION.
PROJECTCLOSE-OUT
1. THECONTRACTORSHALLPROVIDETOTHEENGINEERACOMPLETESETOFPROJECTDOCUMENTS
INDICATING ALL CHANGES TO THE WORK NOT MCORPORATED IN THE DOCUMENTS. CHANGES SHALL
BE ANNOTATED WITH A CONTRASTMG COLOR (RED�. THE ANNOTATE� SET SHALL ALSO MC W DE
MANUFFCTURER'S MODEL NUMBERS OF FIXTURES AN� E�UIPMENT WHICH ARE �IFFERENT FROM THE
PROJECT DOCUMENT INDICATED MODEL NUMBERS.
2. THECONTRACTORSHALLPROVIDETOTHEOWNERACOMPLETESETOFOPERATIONAND
MAINTENANCE MATERIALS INDICATING MAINTENANCE SCHEDULES, TROUBLESHOOTING GUIDELINES
AND MANl1FACTURER'SISUPPLIERS CONTACT MFORMATION.
FIRE STOPPING:
1. FIRE-RATE�CONSTRUCTION'MAINTAINBARRIERANDSTRUCTURALFLOORFIRE
RESISTANCE RATINGS WCLUDING RESISTANCE TO COLD SMOKE ATALL PENETRATIONS.
2. ALL PIPING PENETRATIONS MUST BE SEALED IN ACCORDANCE WITH "UL" LISTED
ASSEMBLIES.
3. VERIFYEXISTINGCONDITIONSANDSUBSTRATESBEFORESTARTINGWORK.CORRECT
UNSATISFACTORV CONDITIONS BEFORE PROCEEDING.
4. ALL FIRESTOPPING PRODUCTS SHALL BE FROM A SINGLE MANUFACTURER
5. THEGONTRACTORSHALLSUBMITFORREVIEWANDACCEPTANCETHEPROPOSEDTHROUGH
PENETRATION ASSEMBLV DETAILS PRIOR TO STARTING THE WORK.
fi. CLEAN SURFACES TO BE IN CONTACT WITH PENETRATION SEAL MATERIALS. OF DIRT,
GREASE, OIL, LOOSE MNTERIALS, RUST, OR OTHER SUBSTANCES THAT MAV AFFECT PROPER
FlTTING, ADHESION, OR THE RE�UIRED FlRE RESISTANCE.
7. INSTALL PENETRATION SEAL MATERIALS IN ACCORDANCE WITH PRIMED INSTRUCTIONS OF
THE U.L FIRE RESISTANGE DIRECTORY AND IN ACCOR�ANCE WITH MANUFACTURER'S
INSTRl1CTI0N.
B. EXAMWE PENETRATION SEALEO AREAS TO ENSURE PROPER INSTALLATION BEFORE
CONCEALING OR ENCLOSING AREAS.
9. KEEP AREAS OF WORK ACCESSIBLE UNTIL MSPECTION BY APPLICABLE CODE AUTHORITIES.
10. PERFORM PATCHING AND REPAIRING OF FIRESTOPPING CAUSED BY CUTTING OR
PENETRATION BY OTHER TRADES.
11. FIRESTOPPINGMATERIALSSHALLBECOMPATABLEWITHPIPINGMATERIALS,AS
RECOMMEN�EDBVTHEMANUFACTURERS.
PLUMBING LEGEN�
SVMBOLS
�OMESTIC COLD WATER
---- ooMesricnoTwnTee�no°F�
�OMESTIC HOT WATER RETl1RN (110° F)
----140- �OMESTICHOTWATER�140°F)
----140- �OMESTICHOTWATERRETURN(140°F)
SANITARY
VENT
STORM�Sn
- - STORM BELOW SLAB/GRADE
STORM OVERFLOW (STO)
- G - NATURALGAS
- C� CONDENSATE
� PIPETURNINGDOWN
PIPE TURNING UP
- TEETURNINGDOWN
TEE TURNING UP
� PIPECAP
��� 'P'TRAP
�� �OH SHUT-0FF VALVE
N CHECKVALVE
�O� BALANCWGVALVE
�O� GASCOCK
CG PRESSURE REDUCINGIREGULATING VALVE
� STRAINER
�'�" SAFETYORRELIEFVALVE
W SOLENOIDVALVE
� OS&YVALVE
�TS OS&YVALVEWITHTAMPERSWRCH
�� FD4 FLOOR DRAIN (Sl1FFlX INDICATES DRAIN TYPE)
� HD HUBDRAIN
--� FS4 FLOOR SINK (SUFFIH INDICATES DRAIN NPE)
� TRENCH DRAIN
� RD-7 ROOFDRAIN�SUFFlXINDICATESDRAINTYPE)
�u FLOOR CLEANOUT
�� WALL OR END-OF-LINE CLEANOUT
�
� PRESSURE6A6E
� THERMOMETER
�WHA WATERHAMMERARRESTOR�SUFFIXINDICATESPDISIZE)
�I� UNION
z"� BACKFLOW PREVENTER (REDUCED PRESSURE ZONE)
� BACKFLOWPREVEMER(DOUBLECHECK)
�� METER (GAS OR WATER)
� PUMP
�WH WALLHYDRANT(SUFFIHINDICATESHVDRANTNPE)
HB HOSEBIBB(Sl1FFlXINDICATESHOSEBIB6TYPE)
F�TP TRAPPRIMER
4 FLOWSWITCH
�IRECTION OF FLOW
- � PIPEANCHOR
� DIRECTIONOFDRAINAGEPIPEPITCH
OSPECIFIC OR NEW WORK NOTES
� REVISION NOTES
e� SANITARVWASTEAN�VENTRISERDESIGNATION
eWATERRISERDESIGNATION
�
5T
� STORM RISER �ESIGNATION
OETAIL OR PLAN N0.
DETAIL OR PLAN 5
SVMBOL SHEETONWHICHDETAILORPLANISDRAWN
SHEET ON WHICH DETAIL OR PLAN IS TAKEN
ABBREVIATIONS
@ AT
' DEGREES
� DELTA
0 DIAMETER
ii POUND,NUMBER
ABV ABOVE
AFF ABOVE FINISH FLOOR
AD AREADRAIN
AHJ AUTHORITY HAVING JURISDICTION
AP ACCESSPANEL
BEL BELOW
BET BETWEEN
BFF BELOW FINISH FLOOR
BOT BOTTOM
BTUH BRITISHTHERMAWNIT/HOUR
CFM CUBIC FEET PER MINUTE
G CASTIRON
t CENTERLME
CNDS CONDENSATE
CO CLEANOl1T
CW COLD WATER
DIA DIAMETER
DN DOWN
DP DRV-PIPE
os oowNSPour
DET DETAIL
DWG DRAWING
E� EQIIAL
EQPT E�UIPMEM
EWC ELECTRIC WATER COOLER
F FARIENHEIT,FIRE
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FlN FlNISH
FFE FINISHED FLOOR ELEVATION
FL FLOOR
FR FROM
FS FLOOR SINK, FLOW SWITCH
FSEC FOODSERVICEEQIIIPMENTCONTRACTOR
FT FOOT
GAL GALLON
GC GENERALGONTRAGTOR
GPM GALLONSPERMINUTE
HCP HANDICAP
HW HOTWATER
HWR HOT WATER RETURN
IE INVERTELEVATION
INV INVERT
IBC INTERNATIONAL BUILDING CO�E
IPC INTERNATIONALPLUMBINGCO�E
KW KITCHEN WASTE
LAV LAVATORV
MBH 10�OBTUH
MH MANHOLE
MTD MOUNTED
NTS NOTTOSCALE
OFCI OWNER FURNISHED CONTRACTOR INSTALLEO
OSBV OUTSIDESCREWANDYOKE
P, PLBG PLUMBING
PC PLUMBING CONTRACTOR
P01 PLUMBINGAN�DRAINAGEINSTITUTE
PIV POSTIN�ICATORVALVE
PRV PRESSURE REDUCING(REGl1LATING)VALVE
RD ROOF �RNIN
RM ROOM
RPM REVOWTIONSPERMINUTE
RWC RAINWATERCON�UCTOR
SA SHOCKARRESTOR
SAN SANITARV
SCHED SCHEDULE
SF S�VAREFOOT
SS SERVICESINK,STAWLESSSTEEL
ST STORM WATER
STO STORMWATEROVERFLOW
T&P TEMPERATUREANDPRESSURERELIEFVALVE
T� TRENCH DRAIN
TLT TOILET
TW TEMPERED WATER
TYP TVPICAL
UNO 11NLESS NOTED OTHERWISE
UR URINAL
V VENT
VAC VACUUM
VB VACUUM BREAKER
VLV VALVE
VTR VENTTHRUROOF
VUSBC VIRGINIAUNIFORMSTATEWIDEBUIL�INGGO�E
W WASTE,WIDE
WC WATERGLOSET
WCO WALLCLEANOUT
WH WALLHVDRANT,WATERHFATER
WST WASTE
XH EXTRA HEAVY
MARK
DESCRIPTION
PLUMBING FIXTURES (SUBSTITUTES REQUIRES ARCHITECTI OWNER'S APPROVAL)
LAVATORV-PUBLIC ARES; UN�ERMOUNT, VITREOUS CHINA, LS GPM
P40 SINGLELEVERFAUCETWITHOFFSETGRIDDRAINANDSTEEL
BRAI�ED SUPPLIEQ ACCESSIBLE
LAVATORV- GUESTROOM; UNDERMOUNT, VITREOUS CHINA, 1.5 GPM
P-1 SINGLE LEVER FAUCET WITH OFFSET GRID DRAIN AND STEEL
BRAIOED Sl1PPLIES
LAVATORY - GUESTROOM; UNDERMOUNT, VITREOUS CHINA, 7.5 GPM
P-0A SINGLELEVERFAUCETWITHOFFSETGRIDDRAINAN�STEEL
BRAIDE� SUPPLIES, ACCESSIBLE
SHOWER- GUESTROOM; MIXING VALVE AND 1.5 GPM HANDHELD
P"z SHOWER @ FUNCTION) WITH 36" SLIDE BAR, AGCESSIBLE
ROLL-W SHOWER-GUESTROOM; FIBERGLASS SHOWER PAN
p_pq WITH MIRING VALVE, HANDHELD SHOWER HEAD AND WALL MOUNTED
SHOWER HEA�, WITH 36" SLIDE BAR, ACCESSIBLE
WATERCLOSET-GUSETROOM ELONGATEDTOILET"128GPF
P-3 (Wq7ERSENSE CERTIFIE��, 30" X 18" X 29-114", FLOOR MOUNTED.
WHITE, ACCESSIBLE
SERVICECONNECTIONS MOl1NTMG
WASTE VENT CW HW HEIGHT REMARKS
FIXTURE'. KOHLER K-2682
FAUCET:KOHLERK-7518
2'• 1_1/T' 1l2" 1/2" COUNTER 7EMPERINGVALVE:APOLLOVALVEMVDR(NOTE2)
INSULATION KIT: TRUBRO
SOAP DISPENSER �. DELTA 72055T
FIXTURE�. AMERICAN STANDARD STUDI00614.000
2" 1-0/2" 1/2" 112" GOUNTER FAUCET:BRR066088LF-ECO
TEMPERING VALVE APOLLO VALVE MVDR (NOTE 2)
FIXTURE'. AMERICAN STANDARD STU�100614000
FAUCET:BRIZO65088LFEC0
7• 1 V2' V2" 7/2" COUMER 7EMPERINGVALVE:APOLLOVALVEMVDR(NOTE2)
INSl1LATI0N KIT�. TRUBRO
2" 1-0/2" il2" 1/2" FLOOR SHOWER'DELTAPROCRYLIC60"x3P'
TRIM: DELTA T13H332
FLOOR DRAIN' JR SMITH 2O05-AHP-CP
2" i ll2" V2" V2" FLOOR SHOWER'KOHLERK-02102-GZZ60"x3fi"
TRIM' DELTA T13H303�25
FLOOR DRAIN: JR SMITH 2O05-AHP-CP
3^ �_��p^ 3�q^ - FLOOR FIXTURE:OELTA,C43908-WH,WHITE
SEAT:BERM15,7900TDGSL.WHITE
1. MOUNTING HEIGHT IS TO FLOOD LEVEL RIM OF FIXTURE UNLESS NOTED OTHERWISE.
2.LOCATETEMPERMGVALVEABOVEACCESSIBLECEILINGORBEHINDANACCESSPANELBELOWTHEFlXTURE. TEMPERINGVALVESHALLBELOCATE�ASCLOSETOTHEFAUCETASPOSSIBLE.
3. SEE MNNUFACTUROR'S INSTALLATION MSTRUCTIONS FOR BLOCKING RE�URMENTS FOR MOUNTING SUPPORT BRACKETS.
PWMBING PIPMG MATERIALS
SVSTEM MATERIAL STANDARD REMARKS
DOMESTIC WATER, BELOW GROUND, 3" AND SMALLER TYPE K COPPER ASTM B88 NOTES 1& 2
DOMESTIC WATER, ABOVE GROUND TYPE L COPPER, INSULATE� ASTM B88 NOTE 7 8 5
PIPING INSULATION - COLD WATER 1" FlBERGLASS, ASJ
PIPINGINSULATION-HOTWATERANDRECIRCULATION 1"FlBERGLASS,ASJ
SANITARY WASTE , ABOVE GROUND PVC - SOLIO CORE ASTM D2729
SANITARY VENT, ABOVE GROUND PVC - SOLIO CORE ASTM D2729
SANITARY WASTE 8 VENT, BELOW GROUND PVC -SOLIO CORE ASTM D 2fi65 NOTE 4
GENERALNOTES'.
A. THROUGH PENETRATION ASSEMBLIES AT RATED WALLS SHALL BE COMPATIBLE WITH PIPING MATERIALS.
B. SUPPLV PIPING SHALL CONFORM TO THE REQUIREMENTS OF NSF 61.
C. PIPE AND FITTINGS FOR A GNEN SYSTEM SHFLL BE PROVIDED BY A SINGLE MANUFACTURER.
NOTES:
1. INSTALL PIPING USING WROUGHT OR CAST FITTINGS AND SOLDER JOINTS USING 95-5 TIN-ANTIMONY SOLDER.
2 USE CONTINllOUS LENGTH OF ANNEALED COPPER COIL FOR PIPING LOCATED BELOW SLAB-ON-GRADE CONSTRUCTION.
3.NOTUSED.
4. SOLVENT CEMENT AN� PRIMER SHALL COMPLV WITH RE�UIREMENTS FOR LOW VOC CONTEM.
5. FITTINGS FOR �OMESTIC WATER PIPING SHALL BE COPPER, NO PLASTIC FITTINGS WILL BE ACCEPTED.
Q
L
N
� -
C
a � � � a
� °-c'mo
:0 d o�«�
y � m O �
y���e�
CONSOLTAVTS
Vr VI
�L �
W a ry
/w '~"� N c
r � w v � m
ry c C
� m j � W
+ � w o c
3Z Sw��
N �
Jw ��o
v Q
\o.P`O°PNiENk (U�O.
; �STnR�
= ��No.v ird],{ooi,9a,�..� '
•```\�� 1X��"
STATE OF �,
�q'�iF; . irvo i nc�a \�$'\.��
/�SSiii�iLii��� .
04I16I20
J (�
~J�M
OZQ7
UQ�Z
Zp�'�
(�Z�w
(�_��
Z�'6JQ
wO�U
�Z�
W
U
�Q �
(n w
N �
Q o
Z
W
�
1 nacnr�crvs s'�n�
1 suevissior�s
I REVISIONS:
aE�EnsEOFoa�
❑ VHELIMINARY ONLY
❑91��ING
� aEamirs
❑ coNsraucnoN
onreov3vzozo
VROJECT N0.:5352
�RAWM LW
oes�rveo��w
cHecK�.leo
sHee.nne.
NOTESANDSCHEDULES
� S�EETM . 002