HomeMy WebLinkAboutC800 Construction Details-C801DATE MARK REVISIONS BYCERTIFIED: S & A JOB NO.
SHEET NO.
DRAWN BY: CHECKED BY:THIS DRAWING IS NOT INTENDED TO BEREPRESENTED AS A RETRACEMENT ORORIGINAL BOUNDARY SURVEY, A ROUTESURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942STORM SEWER DETAILSSECTIONS FOUR A & FOUR BC801
55115PYT-S4THE GROVE at THE LEGACYKJJM/JAW BKR CLAY TOWNSHIP HAMILTON COUNTY, INDIANA03/18/20DP
I
T
E
S
G
E
E
O
TS R
P
RTE WLE
D EHVADIR
J .ADNINAI EEG NIRENOILA NSFEPROSTATE OF
S
File Name: S:\55115-PYT-S4\DWG\C800 Construction Details.dwg - C801Modified / By: August 14, 2020 1:32:44 PM / dmetzPlotted / By: August 14, 2020 3:00:20 PM / Darren Metz04/29/20 REVISED PER TAC COMMENTS DSM05/13/20 REVISED PER CLIENT COMMENTS DSMNOTES:
The storm sewer system shall be constructed per design specified
and as approved by the City of Carmel on the final approved
construction plans. Deviations from the approved design shall
only be permitted due to special circumstances or difficulty during
construction and will require prior field approval from a
designated representative of the City of Carmel in addition to
supplemental approval by the design engineer. An explanation of
any such deviation shall be included as a requirement on
as-built/record drawings submitted for release of performance
guarantees. Approved design slopes identified as generating
velocities of 2.5 fps or less or 10 fps or greater (at full flow
capacity) shall require as-built certification at the time of
construction, prior to backfilling the pipe. The contractor is
instructed to as-built each section of storm pipe as it is being
installed to ensure compliance with the design plans and as
approved by the City of Carmel.
All storm sewers shall be constructed with reinforced concrete
pipe Class III or as noted and conform to A.S.T.M. C-76 or latest
revision. All manholes shall be precast concrete construction in
accordance with State of Indiana Specifications and shall have
Type "A" cast iron ring and cover.
STAMPED "NO DUMPING DRAINS TO WATERWAY".
NOTE: ALL CASTINGS SHALL BE
*
SEE LOGO DETAIL THIS SHEET.
CASTING R-3360A
SHALL BE STAMPED WITH DUMP
NO WASTE LOGO. SEE DETAIL THIS SHEET
NOTE TO CONTRACTOR:
THE CITY OF CARMEL REQUIRES
DOUBLE WALL HANCOR HI-Q SSD
PIPE OR EQUAL TO BE USED.
(AREA INLET)
09/11/20