Loading...
HomeMy WebLinkAboutC200 Site Development Plan S4A-C200753FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM EX. 8'x3' CONCRETE BOX CULVERT BEANS EX. CURB INLET #812 T.C.=755.32 12" R.C.P. E INV.=751.76 EX. BOX CULVERT 117 INV.=747.19 EX. BASIN (VS4) N.P.=746.75 2 YR. ELEV.=749.08 10 YR. ELEV.=749.99 100 YR. ELEV.=752.20 T.O.B.=752.00 W W WWW W W EX. YARD INLET #843 T.C.=755.98 12" R.C.P. N INV.=751.71 T.C.=757.25 15" R.C.P. N INV.=753.12 INV.=752.91 18" R.C.P. W INV.=752.00 12" R.C.P. E INV.=752.10 EX. CURB INLET #838 T.C.=757.32 12" R.C.P. N INV.=752.99 EX. CURB INLET #877 T.C.=753.21 12" R.C.P. E INV.=749.70 15" R.C.P. SW INV.=749.70 EX. CURB INLET #876 T.C.=753.69 12" R.C.P. W INV.=749.80 EX. MANHOLE #139 T.C.=754.10 30" R.C.P. N EX. MANHOLE #177 T.C.=754.60 30" R.C.P. NW INV.=748.97 30" R.C.P. S INV.=748.87 EX. END SECTION #178 30" R.C.P. SE INV.=749.81 EX. INLET #881 T.C.=754.04 12" R.C.P. S INV.=750.28 EX. MANHOLE #878 T.C.=755.14 15" R.C.P. NE INV.=749.60 18" R.C.P. SW INV.=749.60 12" R.C.P. N INV.=749.60 EX. END SECTION #879 18" R.C.P. N INV.=749.22 EX. END SECTION #458AEX. END SECTION #143EX. END SECTION #143A W WW W WW W WWEX. MANHOLE #870A T.C.=754.01 12" R.C.P. E INV.=747.69 12" R.C.P. S INV.=747.59 EX. END SECTION #871 12" R.C.P. N INV.=747.38 EX. CURB INLET #811 T.C.=753.06 12" R.C.P. W INV.=749.37 12" R.C.P. E INV.=749.47 EX. CURB INLET #810 T.C.=753.00 12" R.C.P. W INV.=749.63 EX. CURB INLET #850 T.C.=752.46 27" R.C.P. S INV.=747.91 EX. END SECTION #25 27" R.C.P. N INV.=747.26 EX. END SECTION #14 24" R.C.P. W ASCL 5264 756.39 ASCL 5270 755.52 ASCL 5274 754.42 > o o o15' D&U.E.10' D.U.&S.S.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.50' VAR. D.U. S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. 4' R.A.E. 4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.THE GROVE AT THE LEGACY SECTION THREE A Inst.#2020004967 PC. #5, Slide #1105 EX. 12" FORCEMAIN EX. 8" WATER MAIN EX. 8" WATER MAIN EX. FIRE HYDRANT W W W W W W W W W W W W W W W W W W W W W W W WW W W W W W WW W W W W W W W W W W W50' R/W30' B-BGUEST PARKING8 SPACESGUEST PARKING8 SPACES0+25754.336+97 755.38 0+00 754.16 1+00 754.27 2+00 754.48 3+00 755.15 4+00 755.82 5+00 755.64 0+50 754.28 1+50 754.17 2+50 754.82 3+50 755.48 5+50 755.31 6+50 755.10 50 L.F. 12" R.C.P. @ 0.80%30 L.F. 12" R.C.P. @ 0.30%92 L .F . 1 2 " R .C.P . @ 0 .5 3 %117 L.F. 15" R.C.P. @ 0.87%112 L.F. 27" R.C.P. @ 0.10%30 L.F. 12" R.C.P. @ 0.30%137 L.F. 12" R.C.P. @ 0.77%248 L.F. 12" R.C.P. @ 0.51% HP 4+36.87 756.00 LP 6+14.60 754.94 GRD.CHG. 1+85.53 754.39 HP 0+74.71 754.42 LP 0+19.08 754.09 LP 1+30.89 754.12 GRD.CHG.0+13.38754.11236 L.F. 21" R.C.P. @ 0.14%2+64 756.54 1+00755.42 2+00756.160+50754.982+50756.461+00 755.59 2+00 754.99 3+00 755.27 4+00 756.05 1+50 755.29 3+50 755.66 184A 756.6 183A 756.6 182A 756.2 66A 756.6 67A 756.7 68B 757.0 180B 756.0 181B 756.0 65B 756.0 64B 756.0 63B 757.1 176B 755.0 62A 756.0 754.7 754.0 754.1 754.1 756.2 753.4754.9755.4755.9756.3755.9755.3 756.1755.5 754.0754.7754.4754.1754.7755.0 754.6 755.5756.7755.2 756.0 184B 756.6 183B 756.6 182B 756.2 66B 756.6 67B 756.7 68A 757.0 62B 756.0 61A 756.3 61B 756.3 60A 756.7 60B 756.7 176A 755.0 177B 755.5 177A 755.5 178B 755.0 178A 755.0 179B 756.0 179A 756.0 180A 756.0 181A 756.0 65A 756.0 64A 756.0 63A 757.1 2+64752.131+00754.552+00753.940+50753.832+50752.53GRD.CHG.1+52.00755.30GRD.CHG.0+13.38753.74GRD.CHG.0+35.01 753.61 GRD.CHG. 0+12.00 755.40 GRD.CHG. 0+62.45 755.81 GRD.CHG. 2+36.21 754.77 GRD.CHG. 4+35.99 756.34 GRD.CHG. 4+72.00 756.12 GRD.CHG.0+13.38754.66GRD.CHG.1+52.00755.8730 L.F. 12" R.C.P. @ 0.43% 31 L.F. 12" R.C.P. @ 0.33%311 L.F. 30" R .C.P. @ 0.27%755.8 755.4 755.9 756.5756.2ANTIQUITY DRIVE (PUBLIC)WILBUR ROAD(PRIVATE)ALLEY WEST(PRIVATE)MLAG 757.3 MFF 757.3MFF 757.3MFF 757.3MFF 757.3MFF 757.3MFF 757.3MFF 757.3 MFF 755.8 MFF 755.8 MFF756.7 MFF 756.7 MFF 755.8 MFF 755.8 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.8 MFF 757.8 MFF 757.8 MLAG 755.0 MLAG 757.3 MLAG 757.3MLAG 755.9 MLAG 757.8 MLAG 756.8 MLAG 756.8 MLAG 756.8 MLAG756.8 MLAG 756.8 MLAG 756.8MLAG 756.8 MLAG 756.8 MLAG756.8 MLAG 756.8 MLAG 755.9 MLAG 755.3 MLAG 755.3 MLAG 755.3MFF 757.8 MFF 757.8 MFF 757.8 MFF 756.7 MFF 756.7 ALLEY EAST(PRIVATE)23 L.F. 12" R.C.P. @ 0.30% 14 L.F. 12" R.C.P. @ 0.30% 14 L.F. 15" R.C.P. @ 0.30% 873 845 846 849 867 868 869 872 750 753752 751 754 755 847 875 874 876 877 878756.6 756.0753.7 753.7 753.7 753.8 755.1 754.9 755.4 756.0 756.0756.0756.0757.1755.2754.8756.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 MFF 757.3 10' B.L. 10' B.L. 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.LARSON DRIVE(PUBLIC)LARSON DRIVE(PUBLIC)* * * 20 FEET FORCE MAIN EASEMENT INSTR. No. 2008043639 30' R.D.E.CHERRY CREEK BOULEVARD5' SIDEWALK5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E.10' B.L.6' D.U.&S.S.E. 6' D.U.&S.S.E.10' D.U.&S.S.E.VAR. SIGNEA S EM EN T ANTIQUITY DRIVE (PUBLIC) ALLEY WEST TO EAST (PRIVATE) 755.0 756.2756.212' ASPHALT PATH5' SIDEWALK BUILT WITH FUTURE HOME CONSTRUCTIONJAMES DEAN DRIVE752.94 753.39 753.78 754.18 754.58 754.97 755.33 754.41 754.22 753.71 753.93 754.31 754.68 753.90 12' ASPHALT PATH 12' ASPHALT PATHEX. 5' SIDEWALKPEDESTRIAN ACCESS EXISTING PATH PEDESTRIAN ACCESS LEGEND DENOTES CONSTRUCTION LIMITS EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE EXISTING CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED CONTOUR PROPOSED WATER LINE PROPOSED SWALE PROPOSED GRADE ELEVATION PROPOSED 5' SIDEWALK (BY HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) Ù ADA RAMP TO BE INSTALLED PROPOSED CURB w/ 6" UNDERDRAIN PROPOSED 6" SUB-SURFACE DRAIN LOT NUMBER PAD GRADE MINIMUM FINISH FLOOR ELEVATION MINIMUM LOWEST ADJACENT GRADE MFF=850.70 MINIMUM FINISH FLOOR ELEVATION IS BASED OFF OF THE FOLLOWING CRITERIA: 1. 12" (1.0') ABOVE THE NEAREST UPSTREAM OR DOWNSTREAM SANITARY MANHOLE, WHICHEVER IS LOWEST. 2. 15" (1.25') ABOVE THE HIGHEST ROAD ELEVATION 3. 6" (0.5') ABOVE THE HIGHEST MLAG MLAG MINIMUM LOWEST ADJACENT GRADE (FLOOD PROTECTION) B.L. BUILDING SETBACK LINE M.E. MATCH EXISTING H.P. HIGH POINT L.P. LOW POINT GRD. CHG. GRADE CHANGE STORM SYSTEM STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300) SHOULD BE INSTALLED AS SOON AS PRACTICAL. CONTACTS CARMEL UTILITIES FOR WATER LOCATES (317) 571-2648 RISER 300 850.0 MFF=850.70 MLAG=850.2 DATE MARK REVISIONS BYCERTIFIED: S & A JOB NO.THIS DRAWING IS NOT INTENDED TO BEREPRESENTED AS A RETRACEMENT ORORIGINAL BOUNDARY SURVEY, A ROUTESURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942SHEET NO. DRAWN BY: CHECKED BY:SITE DEVELOPMENT PLANSECTION FOUR AC200 55115PYT-S4THE GROVE at THE LEGACYKJJM/JAW BKR CLAY TOWNSHIP HAMILTON COUNTY, INDIANA03/18/20DP I T E S G E E O TS R P RTE WLE D EHVADI R J .ADNINAI EEG NIRENOILANSFEPROSTATE OF S File Name: S:\55115-PYT-S4\DWG\C200 Site Development Plan S4A.dwg - C200Modified / By: August 14, 2020 2:20:04 PM / dmetzPlotted / By: August 14, 2020 2:47:57 PM / Darren Metz04/29/20 REVISED PER TAC COMMENTS DSM05/13/20 REVISED PER CLIENT COMMENTS DSMGRAPHIC SCALE ( IN FEET ) 1" = 50 FT VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS ON THE SITE. LAND USE ADJACENT PROPERTIES NORTH: GRASS/WEEDS EAST: RESIDENTIAL SOUTH: RESIDENTIAL WEST: GRASS/WEEDS TO CONVERT THE 1929 BENCHMARK TO NAVD88, SUBTRACT 0.43 FEET FROM ALL ELEVATIONS. NGVD29 - 0.43' = NAVD88" DRAINAGE SUMMARY Site Acreage = 5.103 ac. Offsite/Upstream Acreage= 0 ac. Allowable Release Rate Western System: 10yr =21.21 cfs 100yr = 63.63 cfs Post Developed Release Rates: 10yr= 13.82 cfs 100yr= 49.78 cfs This section drains to existing detention basins built with previous sections (Detention Basin VS3 & DD2). These existing basins are part of the overall Western Drainage System per the approved Post Construction Storm Water Master Plan (Sept. 2012). Basin VS3 drains to VS4, which outlets to DD1, DD2 also outlets to DD1, DD1 outlets from the site into the existing Haverstick Community Pond (Elizabeth Werner Drain), and ultimately drains to the White River. Post-Developed Conditions comply with the Allowable Conditions stated in the Legacy Master Drainage Plan. NOTES TO CONTRACTOR 1 ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. 2 ANY PRIVATE TILES LOCATED ON THIS SITE WILL NEED TO BE LOCATED; BREATHERS SET AT THE DOWNSTREAM PROPERTY LINE AND CRUSHED OR REMOVED ACROSS THIS SITE. IF ANY OF THESE TILES EXTEND BEYOND THE LIMITS OF THIS PROJECT, THEY WILL NEED TO BE PROVIDED A POSITIVE OUTLET AND ALLOWED TO CONTINUE TO FUNCTION, AS IT IS ILLEGAL TO BLOCK OFF A PRIVATE "MUTUAL" TILE. 3 CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 4 CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, 5 REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY R/W. 6 NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 7 THERE IS TO BE NO DRIVEWAY ENCROACHMENTS INTO EASEMENTS BETWEEN LOTS. 8 IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES , THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE-FOOT OF THE PROPOSED RIGHT-OF-WAY. 9 DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 10 ALL PAVING WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. 11 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGH-OF-WAY LINE. 12 ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND THE REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. BENCHMARK DATA A STANDARD USGS DISK IN CONCRETE STAMPED "95 RHP 752 1951" AT THE NORTHWEST CORNER OF 146TH STREET AND NORFOLK AND WESTERN RAILROAD, 18.5 FEET NORTH OF THE CENTERLINE OF 146TH STREET. ELEVATION: 751.46' (NGVD 1929) TBM 2 (TSC PROJECT NUMBER 5271.002): TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE, SW. QUADRANT OF 146TH STREET AND RIVER ROAD. ELEVATION: 760.79' (NGVD 1929) S & A TEMPORARY BENCHMARKS TBM #1 A BRONZE DISC SET IN THE EASTERN HEADWALL OF A CULVERT, 2.5 FEET SOUTH OF THE NORTH END OF HEADWALL, SAID CULVERT IS ALONG RIVER ROAD AND 1100 FEET + NORTHEAST OF THE ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED "HAM 25 1964" ELEVATION: 749.52' (NGVD 1929) TBM #2 A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. ELEVATION: 771.54' (NGVD 1929) TBM #3 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14261, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 1150 FEET + EAST OF CHERRY TREE ROAD. ELEVATION: 785.49' (NGVD 1929) TBM #4 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 630 FEET + WEST OF GREYLAN PLACE. ELEVATION: 759.73' (NGVD 1929) TBM #5 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND STAGHORN COURT. ELEVATION: 757.78' (NGVD 1929) TBM #6 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND PLANTATION LANE. ELEVATION: 773.87' (NGVD 1929) TBM #7 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. ELEVATION: 770.76' (NGVD 1929) TBM #8 A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE ROAD AND KLINGENSMITH BLVD. ELEVATION: 773.68' (NGVD 1929) EARTHWORK EXCAVATION A EXCAVATED MATERIAL THAT IS SUITABLE MAY BE USED FOR FILLS. ALL UNSUITABLE MATERIAL AND ALL SURPLUS EXCAVATED MATERIAL NOT REQUIRED SHALL BE REMOVED FROM THE SITE. B PROVIDE AND PLACE ANY ADDITIONAL FILL MATERIAL FROM OFFSITE AS MAY BE NECESSARY TO PRODUCE THE GRADES REQUIRED ON PLANS. FILL OBTAINED FROM OFFSITE SHALL BE OF QUALITY AS SPECIFIED FOR FILLS HEREIN AND THE SOURCE APPROVED BY THE DEVELOPER. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR ANY COSTS FOR FILL NEEDED. REMOVAL OF TREES A. ALL TREES AND STUMPS SHALL BE REMOVED FROM AREAS TO BE OCCUPIED BY A ROAD SURFACE OR STRUCTURE AREA. TREES AND STUMPS SHALL NOT BE BURIED ON SITE. PROTECTION OF TREES A THE CONTRACTOR SHALL, AT THE DIRECTION OF THE DEVELOPER, ENDEAVOR TO SAVE AND PROTECT TREES OF VALUE AND WORTH WHICH DO NOT IMPAIR CONSTRUCTION OF IMPROVEMENTS AS DESIGNED. B IN THE EVENT CUT OR FILL EXCEEDS 0.5 FOOT OVER THE ROOT AREA, THE DEVELOPER SHALL BE CONSULTED WITH RESPECT TO PROTECTIVE MEASURE TO BE TAKEN, IF ANY, TO PRESERVE SUCH TREES. REMOVAL OF TOPSOIL A ALL TOPSOIL SHALL BE REMOVED FROM ALL AREAS BENEATH FUTURE PAVEMENTS OR BUILDING. TOPSOIL REMOVAL SHALL BE TO A MINIMUM DEPTH OF 6 INCHES OR TO THE DEPTH INDICATED IN THE GEOTECHMICAL REPORT PROVIDED BY THE DEVELOPER TO BE EXCAVATED OR FILLED. TOPSOIL SHOULD BE STORED AT A LOCATION WHERE IT WILL NOT INTERFERE WITH CONSTRUCTION OPERATIONS. THE TOPSOIL SHALL BE FREE OF DEBRIS AND STONES. UTILITIES A RULES AND REGULATION GOVERNING THE RESPECTIVE UTILITY SHALL BE OBSERVED IN EXECUTING ALL WORK UNDER THIS SECTION. B IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES 2 WORKING DAYS PRIOR TO COMMENCING WORK. FOR UTILITY LOCATIONS TO BE MARKED CALL 811. SITE GRADING A DO ALL CUTTING, FILLING, COMPACTING OF FILLS AND ROUGH GRADING REQUIRED TO BRING ENTIRE PROJECT AREA TO SUBGRADE AS SHOWN ON THE DRAWING. B THE TOLERANCE FOR PAVED AREAS SHALL NOT EXCEED 0.05 FEET ABOVE ESTABLISHED SUBGRADE. ALL OTHER AREAS SHALL NOT EXCEED 0.05 FEET PLUS OR MINUS THE ESTABLISHED GRADE. PROVIDE ROUNDINGS AT TOP AND BOTTOM OF BANKS AND OTHER BREAKS IN GRADE. C THE ENGINEER SHALL BE NOTIFIED WHEN THE CONTRACTOR HAS REACHED THE TOLERANCE AS STATED ABOVE, SO THAT FIELD MEASUREMENTS AND SPOT ELEVATIONS CAN BE VERIFIED BY THE ENGINEER. THE CONTRACTOR SHALL NOT REMOVE HIS EQUIPMENT FROM THE SITE UNTIL THE ENGINEER HAS VERIFIED THAT THE JOB MEETS THE ABOVE TOLERANCE. HORIZONTAL DATUM SHALL BE BASED ON INDIANA STATE PLANE COORDINATES, NAD83. HORIZONTAL CONTROL/COORDINATE: ℄ MONUMENT N: 1728602.73 E: 221845.61 ALICE PAUL LANE & KNIGHTSTOWN WAY ℄ MONUMENT N: 1727940.59 E: 221845.61 JAMES DEAN DRIVE & KNIGHTSTOWN WAY ℄ MONUMENT N: 1727368.59 E: 222151.58 CUL-DE-SAC BEN KINGSLEY COURT Minimum Flood Protection Grades From Sections 104.02, 302.06 and 303.07 of the City of Carmel Storm Water Technical Standards Manual 1. Definitions a. Minimum Flood Protection Grade of all structures fronting a pond or open ditch shall be no less than 2 feet above any adjacent 100-year local or regional flood elevations, whichever is greater, for all windows, doors, pipe entrances, window wells, and any other structure member where floodwaters can enter a building. b. Lowest Adjacent Grade is the elevation of the lowest grade adjacent to a structure, where the soil meets the foundation around the outside of the structure (including structural members such as basement walkout, patios, decks, porches, support posts or piers, and rim of the window well. 2. Standard: Lowest Adjacent Grade a. General i. The Lowest Adjacent Grade for residential, commercial, or industrial buildings shall have two feet of freeboard above the flooding source's 100-year flood elevation under proposed conditions. b. For areas outside a Special Flood Hazards Area (SFHA) or FEMA or IDNR designated floodplain i. The Lowest Adjacent Grade for all residential, commercial, or industrial buildings adjacent to ponds shall be set a minimum of 2 feet above the 100-year pond elevation or 2 feet above the emergency overflow weir elevation, whichever is higher. ii. The Lowest Adjacent Grade for all residential, commercial, or industrial buildings shall be set a minimum of 2 feet above the highest noted overflow path/ponding elevation across the property frontage. iii. In addition to the Lowest Adjacent Grade requirements, any basement floor must be at least a foot above the normal water level of any wet-bottom pond. 1. Design Notes: a. Each lot that is adjacent to a pond, open ditch or flooding source has a flood protection grade. There are instances where there are multiple different flooding sources for 1 structure. In this case, there should be a flood protection grade listed for each side of the structure in the event that piping from the structure discharge to either flood source. b. Finished floor elevation or the lowest building entry elevation shall be no less than 6 inches above finished grade around the building. Also, the building's lowest entry elevation that is adjacent to and facing a road shall be a minimum of 15 inches above the road elevation. NOTE: ALL DWELLINGS ARE SLAB ON GRADE CONSTRUCTION. NO SUMP PUMP CONNECTIONS ARE REQUIRED FLOOD STATEMENT BASED ON THE 11/19/2014 FIRM PANEL 180567C0231G A PORTION OF THE PROPOSED DEVELOPMENT LIES WITHIN A ZONE X, 0.2 PERCENT CHANCE (500 YR FLOOD PLAIN) FLOOD HAZARD. BASED ON THE WEST FORK WHITE RIVER PROFILE FOR THIS AREA, THE 0.2 PERCENT CHANCE ELEVATION IS BELOW THE FINISHED GROUND ELEVATION OF THE PROPOSED DEVELOPMENT 09/11/20