Loading...
HomeMy WebLinkAboutC303 Storm Water Poll. & Prev.Plan S4B-C303SF SF SF SF SF SF SF SF SF SF750750755 755 755760751751752 75 2753 75375475 4756 756 756757757 757758759750750755755755751751752752753753754754756 75 7 758759756 756 757 757756EX. MH. #726 T.C.=758.49 8" S.D.R. 26 P.V.C N INV.=744.62 8" S.D.R. 26 P.V.C S INV.=744.52 8" S.D.R. 26 P.V.C W INV.=746.23 EX. MH. #725 T.C.=757.98 8" S.D.R. 26 P.V.C E INV.=748.98 8" S.D.R. 35 P.V.C W INV.=749.08 EX. MH. #714 T.C.=754.21 8" S.D.R. 26 P.V.C W INV.=740.71 8" S.D.R. 26 P.V.C E INV.=740.65 EX. MH. #713 T.C.=753.44 8" S.D.R. 26 P.V.C W INV.=739.21 8" S.D.R. 26 P.V.C E INV.=739.16 EX. MH. #712 T.C.=755.06 8" S.D.R. 26 P.V.C S INV.=741.69 8" S.D.R. 26 P.V.C N INV.=737.61 8" S.D.R. 26 P.V.C W INV.=737.43 8" S.D.R. 26 P.V.C E INV.=737.09 EX. MH. #722A T.C.=755.68 8" S.D.R. 26 P.V.C E INV.=742.24 8" S.D.R. 26 P.V.C S INV.=737.81 EX. MH. #722 T.C.=756.30 8" S.D.R. 26 P.V.C N INV.=742.86 8" S.D.R. 26 P.V.C W INV.=742.76 EX. MH. #724 T.C.=757.23 8" S.D.R. 26 P.V.C N INV.=743.60 8" S.D.R. 26 P.V.C S INV.=743.52 8" S.D.R. 26 P.V.C W INV.=745.14 EX. MANHOLE #802 T.C.=755.43 18" R.C.P. N INV.=749.93 18" R.C.P. SE INV.=749.83 12" R.C.P. W INV.=750.28 EX. CURB INLET #813 T.C.=755.25 12" R.C.P. W INV.=751.66 12" R.C.P. E INV.=751.56 EX. CURB INLET #812 T.C.=755.32 12" R.C.P. E INV.=751.76 EX. END SECTION #800A 12" R.C.P. S INV.=753.15 20' Force Main Easement Inst. No.: 2008-043639 EX. DRY DETENTION #2 (DD2) N.P.=750.00 10 YR. ELEV.=751.50 100 YR. ELEV.=753.94 T.O.B.=756.00 EX. YARD INLET #836 T.C.=756.37 12" R.C.P. W INV.=752.50 EX. YARD INLET #825 T.C.=756.44 15" R.C.P. W INV.=751.54 12" R.C.P. E INV.=751.54 EX. MANHOLE #826 T.C.=755.94 27" R.C.P. SW INV.=751.16 18" R.C.P. S INV.=751.25 15" R.C.P. E INV.=751.16 EX. MANHOLE #862 T.C.=756.49 18" R.C.P. E INV.=751.50 18" R.C.P. N INV.=751.45 EX. CURB INLET #827 T.C.=756.18 27" R.C.P. NE INV.=751.00 30" R.C.P. W INV.=751.00 EX. YARD INLET #828 T.C.=755.47 30" R.C.P. E INV.=750.80 30" R.C.P. W INV.=750.80 12" R.C.P. S INV.=751.00 15" R.C.P. N INV.=751.00 EX. CURB INLET #829 T.C.=755.69 30" R.C.P. E INV.=749.97 36" R.C.P. W INV.=749.97 EX. CURB INLET W/2' SUMP #829A T.C.=755.63 36" R.C.P. E INV.=749.91 36" R.C.P. W INV.=749.91 EX. YARD INLET #843 T.C.=755.98 12" R.C.P. N INV.=751.71 EX. END SECTION #830 36" R.C.P. E INV.=749.79 EX. CURB INLET #839 T.C.=757.25 15" R.C.P. N INV.=753.12 EX. MANHOLE #840 T.C.=757.15 15" R.C.P. S INV.=752.91 18" R.C.P. W INV.=752.00 12" R.C.P. E INV.=752.10 EX. MANHOLE #837 T.C.=757.17 12" R.C.P. S INV.=752.91 12" R.C.P. W INV.=752.81 EX. CURB INLET #838 T.C.=757.32 12" R.C.P. N INV.=752.99 EX. MH. #725 T.C.=755.57 8" S.D.R. 35 P.V.C N INV.=745.22 8" S.D.R. 35 P.V.C SE INV.=745.12 EX. MH. #726 T.C.=756.32 8" S.D.R. 35 P.V.C S INV.=746.22 8" S.D.R. 35 P.V.C E INV.=746.32 EX. MH. #727 T.C.=756.66 8" S.D.R. 35 P.V.C N INV.=747.36 8" S.D.R. 35 P.V.C S INV.=747.14 8" S.D.R. 35 P.V.C W INV.=747.04 EX. MH. #728 T.C.=755.61 8" S.D.R. 35 P.V.C N INV.=748.22 EX. MH. #724 T.C.=758.66 8" S.D.R. 35 P.V.C E INV.=751.07 EX. MH. #226 T.C.=758.65 8" S.D.R. 35 P.V.C W INV.=749.66 8" S.D.R. 35 P.V.C E INV.=749.56 EX. MH. #723 T.C.=758.23 8" S.D.R. 35 P.V.C W INV.=749.17 8" S.D.R. 35 P.V.C E INV.=749.13 EX. MANHOLE #177 EX. END SECTION #178 30" R.C.P. SE INV.=749.81 EX. INLET #881 T.C.=754.04 12" R.C.P. S INV.=750.28 15' D&U.E. 15' D&U.E.15' D&U.E. 15' D&U.E. 15' D&U.E.10' D.U.&S.S.E. 10' D.U.&S.S.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E.10' D.&U.E.50'50' VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. VAR. I.E.E.& D.U.&S.S.E. 4' R.A.E. 4' R.A.E. 4' R.A.E. 4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E. 4' R.A.E.4' R.A.E. 4' R.A.E.4' R.A.E. 4' R.A.E. 4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.757758 756756 751 752 753 BIRTHRIGHT WAY WILBUR ROAD(PRIVATE)ANTIQUITY DRIVE BIRTHRIGHT WAY PICKETT PLACE JAMES DEAN DRIVE(PRIVATE) (PRIVATE) EX. 8" WATER MAIN EX. FIRE HYDRANT EX. FIRE HYDRANT EX. 8" WATER MAIN EX. FIRE HYDRANT (PRIVATE)SF SF SF SF SF SF SF SF SF SF SFSFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF POSTING SIGN LOCATION EARTHWORK CONTRACTOR SHALL INSTALL 20' x 150' MIN. STONE ACCESS DRIVE PRIOR TO CONSTRUCTION.SF SF SF SFSFSF SF SF SFSF SF SF SFSF SF SF SFSF SF SFCONCRETE WASH OUT AREA DEBRIS CONTROL AREATEMP. CONSTRUCTION STAGING AREA PORT-O-LET Z Z DATE MARK REVISIONS BYCERTIFIED: S & A JOB NO. SHEET NO. DRAWN BY: CHECKED BY:THIS DRAWING IS NOT INTENDED TO BEREPRESENTED AS A RETRACEMENT ORORIGINAL BOUNDARY SURVEY, A ROUTESURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942INTIAL STORM WATER POLL. & PREV. PLANSECTION FOUR BC303 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT 55115PYT-S4THE GROVE at THE LEGACYKJJM/JAW BKR CLAY TOWNSHIP HAMILTON COUNTY, INDIANA03/18/20DP I T E S G E E O TS R P RTE WLE DEHVADI R J . ADNINAI EEG NIRENOI LA NSFEPROSTATE OF S File Name: S:\55115-PYT-S4\DWG\C303 Storm Water Poll. & Prev.Plan S4B.dwg - C303Modified / By: August 14, 2020 11:48:36 AM / dmetzPlotted / By: August 14, 2020 2:50:17 PM / Darren Metz04/29/20 REVISED PER TAC COMMENTS DSM05/13/20 REVISED PER CLIENT COMMENTS DSMFOR EROSION CONTROL ONLY. THIS SHEET TO BE USED PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: TODD PYATT PHONE: (317) 379-0184 NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. ANY DISCHARGE OF CONTAMINATED WATER DUE TO DEWATERING SHALL OUTLET THROUGH EXISTING VEGETATION OR FILTER BAGS THAT WILL NOT ADVERSELY IMPACT STORM WATER QUALITY. NOTE: 1. ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. 2. IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON POLYMER. 3. CONTRACTOR TO STAY WITHIN CONSTRUCTION LIMITS TO MAINTAIN VEGETATIVE BUFFER AREAS. 4. THERE ARE NO PROPOSED BMP STRUCTURESFOR THIS PHASE OF DEVELOPMENT. LEGEND Denotes Silt Fence Denotes Construction Limits Temporary "Coconut Fiber Mat" or Below Grade " Drop Inlet Protection Basket" Temporary "Drop Inlet Protection Basket", "Sediment Control Devices" SF SF SF 09/11/20