HomeMy WebLinkAboutA000_CoverSheetPROJECT INFORMATION
PROJECT SQUARE FOOTAGE
REMODEL:
NEW CONSTRUCTION:
OCCUPANCY:
CONSTRUCTION TYPE:
TENANT/CLIENT REPRESENTATIVE SIGNATURE
DATETENANT/CLIENT REPRESENTATIVE NAME PRINTED
THE TENANT/CLIENT AGREES THAT THESE DRAWINGS AND SPECIFICATIONS
REPRESENT THE ENTIRE SCOPE OF WORK FOR THE IMPROVEMENTS TO BE
PROVIDED. THE TENANT/CLIENT'S SIGNATURE BELOW REPRESENTS ACCEPTANCE
OF THE FINAL DESIGN. ANY CHANGES TO THIS SCOPE OF WORK INITIATED BY THE
TENANT/CLIENT WILL CAUSE CHANGES IN THE TOTAL COST TO THE TENANT/CLIENT
AND IN THE COMPLETION DATE FOR THE PROJECT.
APPROVAL FOR CONSTRUCTION
DRAWING INDEX
PROJECT TEAM
INTERIOR DESIGNER
PARALLEL DESIGN GROUP
8801 RIVER CROSSING BLVD.
SUITE 140
INDIANAPOLIS, IN 46240
PH 317.721.4399
briana@paralleldg.com
ARCHITECT
DESIGNPOINT INC.
GEORGE SMALL
4676 ST. JOHN CIR.
ZIONSVILLE, IN 46077
PH 317.289.8007
gsmall@designpointarchitects.com
5,766 SQFT
YES
NO
(B)USINESS
V-B
1. EACH CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF
THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THIS
FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK
DESCRIBED ON ALL SHEETS OF THE DRAWINGS. FAILURE BY THE CONTRACTOR TO
BECOME COMPLETELY FAMILIAR OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE
THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS ASSEMBLIES, OR
SERVICES INDICATED IN THE CONTRACT DOCUMENTS.
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE
AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE
CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE.
3. FIELD VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS INDICATED ON THE
DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR
TO PARALLEL DESIGN GROUP BEFORE BEGINNING ANY CONSTRUCTION.
4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING
ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE,
MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORKSITE,
TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING
CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS"
WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT
SCOPE.
5. GENERAL CONTRACTOR TO REVIEW DOCUMENTS IN DETAIL AND COMMUNICATE
ANY ITEMS THAT MAY REQUIRE LEAD TIMES. CONTRACTOR TO COORDINATE PROJECT
SCHEDULE ACCORDINGLY AND COMMUNICATE TO TEAM ANY DECISIONS THAT NEED
TO BE MADE TO KEEP PROJECT SCHEDULE ON TRACK. CONTRACTOR IS RESPONSIBLE
FOR DELAYS WHEN LEAD TIMES ARE NOT PROPERLY COMMUNICATED TO OWNER
AND PARALLEL DESIGN GROUP.
6. NO SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS/MATERIALS WILL BE
ALLOWED WITHOUT PRIOR APPROVAL FROM PARALLEL DESIGN GROUP. PRODUCT
CHANGE SUBMITTALS SHOULD BE COMMUNICATED TO PARALLEL DESIGN GROUP
ALLOWING ADEQUATE TIME TO RESPOND.
7. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE
DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE
INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E.
WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF
LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN).
8. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO PARALLEL DESIGN
GROUP FOR APPROVAL ON ALL MATERIALS/PRODUCTS IF THE DRAWINGS DO NOT
INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
9. PROVIDE SUBMITTAL SHOP DRAWINGS IN A TIMELY FASHION TO ALLOW
SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND
DELIVERY OF MATERIALS AND EQUIPMENT.
10. ALL MATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY SPECIFIED OR
NOT, AND WITH THE LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE
INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE
OF THE FINISHED PROJECT.
11. EACH CONTRACTOR SHALL FULLY REVIEW DRAWING SHEETS TO FULLY
UNDERSTAND NEW WORK AND EXISTING CONDITIONS TO DETERMINE FULL EXTENT
OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE IN ADDITION TO COORDINATING
FULL EXTENT OF RESPONSIBILITIES WITH ALL OTHER TRADES. FIELD WORK ORDERS &
CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS
THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD
INSPECTION AND AFTER AWARD OF CONTRACT.
12. THE GENERAL CONTRACTOR IS REQUIRED TO PATCH AND REPAIR ANY DAMAGED
EXISTING SURFACE TO MATCH NEW.
13. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL
PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR
FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND
SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW.
14. ALL EQUIPMENT, MATERIALS AND/OR FIXTURES SHALL BE INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
15. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION
THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL
GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK.
16. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR
INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE
PROJECT.
17. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ALL DIMENSIONS ARE FROM
FINISHED FACE OF WALL TO FINISHED FACE OF WALL.
18. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW
BLINDS.
19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED
DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL
AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY
THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE
OWNER/CONTRACTOR AGREEMENT.
20. NOTE REGARDING PROJECTS WITHIN MARION COUNTY: LOCAL ORDINANCE
REQUIRES ONE SET OF CONSTRUCTION DRAWINGS FOR CLASS 1 STRUCTURES, THAT
ARE DESIGNED WITH A FIRE PROTECTION AND LIFE SAFETY SYSTEMS (I.E. FIRE
ALARMS), BE SUBMITTED TO THE INDIANAPOLIS FIRE DEPARTMENT (IFD) FOR THE
PURPOSE OF CONDUCTING A FIRE DEPARTMENT PLAN REVIEW AND ON-SITE
INSPECTIONS. DRAWING SET SHOULD INCLUDE ARCH, STRUCT, MECH, ELEC,
SPRINKLER, FIRE ALARM, AND SITE/CIVIL (WHERE APPLICABLE). DRAWINGS MAY BE
DELIVERED OR MAILED TO THE IFD PLAN REVIEW DIVISION (1200 MADISON AVENUE,
INDIANAPOLIS, IN 46225, ATTENTION: T.J. BURNS). INCLUDE THE DMD STRUCTURAL
PERMIT NUMBER (STR-XXXXXX) WITH THE DRAWING SET. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SUBMISSION OF
THESE DRAWINGS AND THE REQUIRED FEE TO THE IFD PLAN REVIEW DIVISION.
CONTACT THE IFD WITH QUESTIONS REGARDING THIS REQUIREMENT (317-327-5529).
GENERAL PROJECT NOTES DEMOLITION NOTES
1. ALL EXISTING EQUIPMENT, FIXTURES, ETC. SHALL REMAIN PROPERTY OF THE
OWNER. ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION SHALL BE RETAINED
FOR THE OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE
OWNER SHALL BE DISPOSED.
2. CONTRACTOR TO VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS.
DEMOLITION DRAWINGS ARE A REFERENCE TO AID CONTRACTOR IN EVALUATION OF
THE EXTENT OF THE DEMOLITION, BUT SHALL NOT BE CONSIDERED ALL INCLUSIVE.
CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC.
REFERENCE NEW CONSTRUCTION DRAWINGS TO DETERMINE THE FULL EXTENT OF
NECESSARY DEMOLITION.
3. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. THE CONTRACTOR SHALL VERIFY IN THE
FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT PARALLEL DESIGN GROUP IMMEDIATELY IF THE
CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION
APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. THE CONTRACTOR IS
SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL
SYSTEM.
4. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED
OR NOTED FOR THE INSTALLATION OF THE NEW WORK.
5. EACH TRADE CONTRACTOR IS RESPONSIBLE TO REFER TO NEW CONSTRUCTION
DRAWINGS FOR ADDITIONAL PATCHING AND PREPARATION WORK RELATED TO THE
DEMOLITION ITEMS.
6. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF
THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL
INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE
REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE
DIRECTED BY OWNER.
7. CHECK EXISTING FLOOR LEVEL BEFORE INSTALLATION OF NEW FLOORING. PREPARE
FLOOR WITH CEMENTITIOUS LEVELING COMPOUND PRIOR TO INSTALLATION OF NEW
FLOOR FINISH AS REQUIRED TO MAINTAIN LEVEL.
8. REMOVE ALL ITEMS ASSOCTIATED WITH DEMOLISHED WALL IF NOT NOTED OR
SHOWN OTHERWISE. SALVAGE ANY ITEMS IS GOOD CONDITION FOR REUSE IN NEW
CONSTRUCTION, e.g., OUTLETS.
9. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
SURFACES, MATERIALS, COMPONENTS, ETC. TO REMAIN OR BE RELOCATED. ANY
DAMAGE TO THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY
THE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND PARALLEL DESIGN
GROUP AT NO ADDITIONAL EXPENSE TO THE OWNER..
10. COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND
REGULATIONS. ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE.
11. THE CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED
BY THE OWNER TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING
OUT OF THE PROJECT AREA. THE OWNER SHALL CONFIRM ALL DUST PREVENTION
MEASURE/LOCATIONS, AND SHALL DETERMINE ANY CHANGES TO THESE MEASURES.
12. REMOVE DUST AND DEBRIS FROM NEWLY EXPOSED SURFACES.
13. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL
PERMANENTLY ABANDONED SYSTEMS.
14. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
1. POWER AND COMMUNICATION PLAN IS TO SHOW ELECTRICAL, VOICE/DATA
RECEPTACLES AND TV LOCATIONS. ELECTRICAL CONTRACTOR TO FIELD VERIFY
LOAD CAPACITIES AND AVAILABILITY. PARALLEL DESIGN GROUP AND THEIR
ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL
ENGINEERING.
2. REFLECTED CEILING PLAN IS TO SHOW LIGHT FIXTURE, DIFFUSER AND SWITCH
LOCATIONS ONLY. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT
RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL ENGINEERING.
3. ELECTRICAL CONTRACTOR RESPONSIBLE FOR RELOCATION AND/OR
ADDITION OF HORN STROBES, FIRE ALARM STATIONS AND EXIST SIGNS AS
REQUIRED BY CODE.
4. VERIFY IF ANY SPECIAL EQUIPMENT WILL REQUIRE ADDITIONAL AIR FLOW.
PROVIDE ADDITIONAL HVAC REQUIREMENTS AFTER APPROVAL FROM TENANT.
REVISE ZONING AS NEEDED.
5. PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM SYSTEMS SHALL BE DESIGNED
AND INSTALLED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS PER
AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR
RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL
BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL
INFORMATION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. PARALLEL
DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY
ENGINEERING FOR THESE SYSTEMS.
6. COORDINATE CIRCUITRY REQUIREMENTS FOR FURNITURE SYSTEMS WITH
TENANT, BEFORE RUNNING WIRING TO JUNCTION BOXES.
7. CENTER IN CEILING TILES RECESSED DOWNLIGHTS, SMOKE DETECTORS,
SPRINKLER HEADS, AND EXIT SIGNS, UNLESS OTHERWISE NOTED.
8. REVIEW FIRE DETECTION DEVICE LOCATIONS WITH TENANT PRIOR TO
INSTALLATION.
9. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA
BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS,
CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION
OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS.
MECHANICAL &
ELECTRICAL NOTES
FIRE PROTECTION NOTES
1. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER
THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL
DESIGN GROUP IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
RENOVATION OF THE FIRE SPRINKLER SYSTEM.
2. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING
CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND
REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE
SUPPRESSION SYSTEMS.
3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS,
AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND
LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
1. ALL MATERIALS TO BE DELIVERED IN THEIR ORIGINAL PACKAGING WITH
MANUFACTURER'S LABELS. CONTRACTOR WILL BE RESPONSIBLE FOR RECEIVING,
STORING AND PROTECTING MATERIALS FROM ANY DAMAGE BY MOISTURE, WIND,
SUN ABUSE, OR ANY HARMFUL EFFECTS. DAMAGED MATERIALS WILL BE
REJECTED AND MUST BE REPLACED BY THE CONTRACTOR.
2. REMOVE ALL PLATES AND SWITCHES BEFORE PAINTING AND REATTACH
AFTERWARDS.
3. ALL REMAINING PAINT (1 GALLON MINIMUM) TO BE LEFT WITH THE OWNER.
4. WALLCOVERING SHALL BE FROM THE SAME PRODUCTION RUN.
5. DO NOT LOCATE WALLCOVERING SEAMS ON CORNERS. WRAP 6" BEYOND
INSIDE OR OUTSIDE CORNERS AS INDICATED ON THE FINISH PLAN WHERE
CHANGE OF WALLCOVERING LOCATION OCCURS.
6. CONTRACTOR TO REMOVE EXCESS ADHESIVE IMMEDIATEDLY FROM SURFACE
OR WALLCOVERING AS EACH JOINT OR SEAM IS MADE AND BEFORE PROCEEDING
TO THE NEXT JOINT OR SEAM.
7. ALL WALLCOVERING SEAMS ARE TO BE CUT STRAIGHT. ASSURE INSTALLATION
IS SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, BUBBLES, GAPS, AND/OR
OVERLAPS.
8. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE
GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS,
TAPING DETAILS, CORNER BEADS, ETC.)
9. TRANSITION OF DIFFERENT FLOORING MATERIALS SHALL OCCUR AT THE
CENTERLINE OF THE DOOR.
10. CONTRACTOR TO PROVIDE AND INSTALL TRANSITION STRIP BETWEEN
DISSIMILAR FLOORING MATERIALS. TRANSITION STRIP IS TO BE SCHLUTER OR
EQUAL WITH BRUSHED ALUMINUM FINISH OR IS TO BE VINYL AND MATCH VINYL
BASE COLOR (IE.: WHERE VCT MEETS CARPET). CONTRACTOR TO DETERMINE
TYPE OF SCHLUTER STRIP BASED ON DISSIMILAR FLOORING MATERIALS.
CONTRACTOR TO VERIFY TYPE OF TRANSITION WITH PARALLEL DESIGN, IF NOT
NOTED, PRIOR TO PLACING ORDER.
11. SUBFLOOR MUST BE LEVEL, SOUND, RIGID, CLEAN/FREE OF ANY DEBRIS, AND
PERMANENTLY DRY PRIOR TO INSTALLATION. THE INSTALLATION OF FINISH
FLOORING MATERIALS SHALL SERVE AS ACCEPTANCE OF SLAB CONDITION.
12. FLOORING MATERIALS SHALL BE FROM THE SAME PRODUCTION RUN.
13. CONTRACTOR SHALL REPAIR, REFINISH OR TOUCH-UP SURFACES DAMAGED
BY SUBSEQUENT WORK. (EXAMPLE: WHERE NEW OUTLETS/FIXTURES HAVE BEEN
INSTALLED)
14. LOW VOC CONTENT PAINT AND ADHESIVES TO BE USED THROUGHOUT
PROJECT.
15. REVIEW AND ABIDE BY ALL MANUFACTURER INSTALLATION INSTRUCTIONS
PRIOR TO INSTALLATION OF FINISH MATERIALS. MANUFACTURER
RECOMMENDED ADHESIVES/SEALANTS TO BE USED.
16. UPON COMPLETION OF ALL FINISH APPLICATIONS, ALL MATERIALS AND
EQUIPMENT SHALL BE REMOVED. CONTRACTOR SHALL INSURE THAT ALL AREAS
ARE LEFT CLEAN AND DAMAGE FREE.
17. ANY VARIATION IN PATTERN, TEXTURE, COLOR OR ANY OTHER DEFECT
SHOULD BE BROUGHT TO THE ATTENTION OF PARALLEL DESIGN GROUP FOR
DIRECTION AND APPROVAL.
FINISH NOTES
10. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED.
PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE
APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF
WORK.
11. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS. AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS,
WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE
PROJECT.
MECHANICAL &
ELECTRICAL NOTES CONTINUED
[ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 [ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY]N
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.2020.16907.30.2020BWSB & BDPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032PYATT BUILDERS
07.30.2020
CONSTRUCTION DOCUMENTS
630 3RD AVENUE SOUTHWEST - 2ND & 3RD
FLOOR
CARMEL, INDIANA 46032
COVER SHEET
A000
A000 COVER SHEET
A001 SECOND FLOOR LIFE SAFETY PLAN
A002 THIRD FLOOR LIFE SAFETY PLAN
A003 ACCESSIBILITY
A004 WALL TYPES
D101 SECOND FLOOR DEMOLITION PLAN
A101 SECOND FLOOR PLAN
A101D SECOND FLOOR DIMENSION PLAN
D102 THIRD FLOOR DEMOLITION PLAN
A102 THIRD FLOOR PLAN
A102D THIRD FLOOR DIMENSION PLAN
A110 DOOR SCHEDULES
A120 ENLARGED RESTROOM PLANS
A201 SECOND FLOOR REFLECTED CEILING PLAN
A202 THIRD FLOOR REFLECTED CEILING PLAN
A301 SECOND FLOOR POWER AND DATA
A302 THIRD FLOOR POWER AND DATA
A401 SECOND FLOOR FINISH PLAN
A402 THIRD FLOOR FINISH PLAN
A500 INTERIOR ELEVATIONS
MAP_LOCATION Revision ScheduleDate Description09/16/20
SCOPE OF WORK:
OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE.
OCCUPANCY CLASSIFICATION:
B (BUSINESS)
CHANGE OF OCCUPANCY CLASS:
NO
TOTAL BUILDING AREA:
10,686 GROSS SF
TOTAL AREA ON FLOOR:
SECOND FLOOR: 4,920 SQ.FT.
THIRD FLOOR: 846 SQ.FT.
TOTAL PROJECT AREA:
5,766 SQ.FT.
OCCUPANCY CALCULATIONS
SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
GENERAL OFFICE 3,552 100 35.5
CONFERENCE 1,081 15 72
STORAGE 202 300 .7
TOTAL OCCUPANTS IN PROJECT AREA:108.2
NUMBER OF REQUIRED EXITS:
2
MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300'
SPRINKLER SYSTEM (YES/NO):
YES-EXISTING TO REMAIN
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
N/A
APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD,
ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH
INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT -BUILDING EXIT LOCATION
FIRE EXTINGUISHER
EXIT SIGNAGE
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING,
REFRENCE A200 FOR LOCATION.
LEGEND
EX
FE
EL
NL
EP
AREA NOT IN CONTRACT
AREA OF WORK
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
EX
ELOFFICE
205
131 SF
SMALL CONFERENCE
206
131 SF
SMALL CONFERENCE
207
OFFICE
208
TODD'S OFFICE
209
OPEN OFFICE
210
OFFICE
213
OFFICE
212
OFFICE
211
COPY
227
9 SF
HVAC
226
13 SF
ACCT. STRG.
224
13 SF
STRG.
223
29 SF
OFFICE STORAGE
202
GUEST R.R.
201
GUEST R.R.
204
JAN.
203
RECEPTION
200
SEMI-PRIVATE OFFICE
214
49 SF
SERVER
215 OSM
216
OSM
217
35 SF
STUDIO STORAGE
218 87 SF
MEETING
221
89 SF
MEETING
220
JENNIFER'S OFFICE
219
DESIGN STUDIO
222 FEFE
FE
EX
EL
ELELELCOMMON PATH OF EGRESS = 8'
EXIT ACCESS TRAVEL = 60'
COFFEE
225
EXIT ACCESS TRAVEL = 117'COMMON PATH OF EGRESS = 24'EXIT ACCESS TRAVEL = 45'EXIT ACCESS TRAVEL = 51'EXIT ACCESS TRAVEL = 44'1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA001
SECOND FLOOR
LIFE SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
SECOND FLOOR LIFE SAFETY PLAN 1 MARK DATE DESCRIPTION09/16/20
SCOPE OF WORK:
OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE.
OCCUPANCY CLASSIFICATION:
B (BUSINESS)
CHANGE OF OCCUPANCY CLASS:
NO
TOTAL BUILDING AREA:
10,686 GROSS SF
TOTAL AREA ON FLOOR:
SECOND FLOOR: 4,920 SQ.FT.
THIRD FLOOR: 846 SQ.FT.
TOTAL PROJECT AREA:
5,766 SQ.FT.
OCCUPANCY CALCULATIONS
SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
GENERAL OFFICE 3,552 100 35.5
CONFERENCE 1,081 15 72
STORAGE 202 300 .7
TOTAL OCCUPANTS IN PROJECT AREA:108.2
NUMBER OF REQUIRED EXITS:
2
MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300'
SPRINKLER SYSTEM (YES/NO):
YES-EXISTING TO REMAIN
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
N/A
APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD,
ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH
INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.ELEX
EXIT ACCESS TRAVEL = 46'
63 SF
MARKETING STORAGE
301
643 SF
CONFERENCE
300
20 SF
HVAC
302
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT -BUILDING EXIT LOCATION
FIRE EXTINGUISHER
EXIT SIGNAGE
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING,
REFRENCE A200 FOR LOCATION.
LEGEND
EX
FE
EL
NL
EP
AREA NOT IN CONTRACT
AREA OF WORK
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA002
THIRD FLOOR LIFE
SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
THIRD FLOOR PLAN LIFE SAFETY 1 MARK DATE DESCRIPTION09/16/20
18"1 1/2" DIAMETER GRAB
BAR, 1 1/2" MIN. GAP
FROM WALL (TYPICAL)
FOLD DOWN
SHOWER SEAT
1 1/2" DIAMETER GRAB
BAR, 1 1/2" MIN. GAP
FROM WALL (TYPICAL)
SOAP SHELF, WHERE
INDICATED
CONTROL AREA
HAND HELD ADJUSTABLE
SHOWER HEAD (ADA)
TRANSFER ADA SHOWER
1' - 6" 1' - 6"3' - 4" 33" - 36"3' - 10"4' - 0 1/4"3' - 1 3/4" MAX32" MIN - 34" MAX19" MIN
MAINTAIN MIN.
ACCESSIBLE
CLEARANCES AS
DIMENSIONED 9" MIN 27" MIN
ACCESSIBILITY ROLL-UNDER CLEARANCES
T-SHAPED TURNING SPACEARMARMBASE
MIN.
1' - 0"
MIN.
3' - 0"
MIN.
1' - 0"MIN.3' - 0"MIN.2' - 0"MIN.
5' - 0"MIN.5' - 0"X > 24"36" MIN.
MANEUVERING CLEARANCE IN AN ALCOVE:
FORWARD APPROACH X > 15"60" MIN.
MANEUVERING CLEARANCE IN AN
ALCOVE: PARALLEL APPROACH
ELEVATION PLAN9"MAX.
6" 30" MIN.17"-25"
TOE CLEARANCE
8" MIN.2' - 4" MIN.9" MIN.MIN.
11"
MAX.
1' - 5"2' - 6" MIN.ELEVATION PLAN
KNEE CLEARANCE
4" MAX.X > 27"X 80"³LIMITS OF PROTRUDING OBJECTS 27" MAX.X > 80"VERTICAL CLEARANCE
15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH
20" MAX.48" MAX.44" MAX.UNOBSTRUCTED HIGH FORWARD REACH
A. B.32" MIN.36" MIN.32" MIN.36" MIN.24" MAX. 48" MIN. 24" MAX.
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
(A)
180 DEGREE TURN
(B)
180 DEGREE TURN (EXCEPTION)48" MIN.42" MIN. 42" MIN.
X < 48"
36" MIN. 36" MIN.
X < 48"60" MIN.CLEAR WIDTH AT TURN
(C)
FOLDING DOOR
(A)
HINGED DOOR
(B)
SLIDING DOOR
32" MIN. 32" MIN. 32" MIN.90°CLEAR WIDTH OF DOORWAYS
(A)
FRONT APPROACH, PULL SIDE (B)
FRONT APPROACH, PUSH SIDE
(C)
FRONT APPROACH, PUSH SIDE
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
(D)
HINGE APPROACH, PULL SIDE
(E)
HINGE APPROACH, PULL SIDE
(F)
HINGE APPROACH, PUSH SIDE
(G)
HINGE APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
(H)
LATCH APPROACH, PULL SIDE
(I)
LATCH APPROACH, PULL SIDE,
DOOR PROVIDED WITH CLOSER
(J)
LATCH APPROACH, PUSH SIDE
(K)
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
18" MIN.48" MIN.12" MIN. 48" MIN.36" MIN. 60" MIN.42" MIN.54" MIN.42" MIN.22" MIN. 48" MIN.22" MIN.48" MIN.24" MIN. 54" MIN.24" MIN 24" MIN. 42" MIN.24" MIN.48" MIN.60" MIN.(A)
PULL SIDE
(B)
PUSH SIDE
(C)
PUSH SIDE, DOOR PROVIDED
WITH BOTH CLOSER AND LATCH60" MIN.18" MIN.X > 8"48" MIN.X > 8"X > 8"12" MIN.48" MIN.MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES
(A) (B)
(C)
48" MIN. 48" MIN.48" MIN.
DOOR IN SERIES AND GATES IN SERIES
(A)
STAIRS
(B)
RAMPS
(C)
WALKING SURFACES34" - 38"34" - 38" 34" - 38"HANDRAIL HEIGHT
1 1/2" MIN.1 1/2" MIN.HANDRAIL CLEARANCE HANDRAIL PROJECTIONS
BELOW GRIPPING SURFACE
NOTE: X = TREAD DEPTH
12" MIN.
12" MIN.
12" MIN.
X
X
TOP AND BOTTOM HANDRAIL
EXTENSION AT RAMPS
TOP HANDRAIL EXTENSION
AT STAIRS
BOTTOM HANDRAIL
EXTENSION AT STAIRS
5" MAX. 15" MIN.
DRINKING FOUNTAIN SPOUT LOCATION
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA003
ACCESSIBILITYPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032MARK DATE DESCRIPTION09/16/20
A2
A3
WALL PARTITION TYPEPLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
A
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL
ELIMINATOR TRACK
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
CEILING GRID
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
3 -3/4"
4 -7/8"3 -5/8"
2 -1/2"
STC:
NO SOUND
WITH SOUND
A2S
A3SB2
B3
B6
B1 B1S
WALL PARTITION TYPE 42" FINISHEDPLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
B
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL
METAL RUNNER
LINE OF
STRUCTURE
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 -7/8"
3 -3/4"
4 -7/8"
7 -1/4"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
B2S
B3S
B6S
B8 NON-
RATED NA9 -1/4"8"
B8S
UNDERSIDE OF
STRUCTURE
C2
C3
C6
C1 C1S
WALL PARTITION TYPE 4"PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
C
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; ONE SIDE, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL.
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE
OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 -1/4"
3 -1/8"
4 -1/4"
6 -5/8"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
C2S
C3S
C6S
C8 NON-
RATED NA 8 -5/8"8"
C8S
LATERAL BRACING AT 4'-0" O.C. MAX.
E2
E3
E6
E1 E1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
E
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; ONE SIDE, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL.
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE
OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 -1/4"
3 -1/8"
4 -1/4"
6 -5/8"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
E2S
E3S
E6S
E8 NON-
RATED NA 8 -5/8"8"
E8S
SEALANT AND BACKER ROD; ONE SIDE, CONT.
D2
D3
D6
D1 D1S
WALL PARTITION TYPE4"PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
D
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 -7/8"
3 -3/4"
4 -7/8"
7 -1/4"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
D2S
D3S
D6S
D8 NON-
RATED NA9 -1/4"8"
D8S
LATERAL BRACING AT 4'-0" O.C. MAX.
F2
F3
F6
F1 F1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
F
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW
METAL RUNNER
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS;
REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION,
AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD
REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA 2 -7/8"
3 -3/4"
4 -7/8"
7 -1/4"6"
3 -5/8"
2 -1/2"
1 -5/8"
STC:
NO SOUND
WITH SOUND
F2S
F3S
F6S
F8
9 -1/4" 8"
F8S
SEALANT AND BACKER ROD; BOTH SIDES, CONT.
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. NOT
ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER
TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA004
WALL TYPESPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032MARK DATE DESCRIPTION09/16/20
1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8"
DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F.
2. REMOVE ALL LIGHT FIXTURES. REFERENCE REFLECTED CEILING
PLAN A201.
3. PATCH CORE DRILLS/HOLES IN FLOOR AS REQUIRED.
4. REMOVE HVAC DIFFUSERS AND RETURNS AS REQUIRED. REUSE
FIXTURES IN GOOD CONDITION.
5. REMOVE ALL EXISTING FINISHES. REFERENCE FINISH PLAN A400
FOR FINAL FINISH PLAN.
GENERAL NOTES
LEGEND
NEW CONSTRUCTION
SOLID LINES INDICATE EXISTING ITEMS TO REMAIN.
NOTE: REFERENCE THE COVER SHEET FOR GENERAL
DEMOLITION NOTES.
KEYED NOTES
DASHED LINES AND SYMBOLS INDICATE EXISTING
ITEMS TO BE REMOVED OR SALVAGED. REFERENCE
PLAN NOTES.
PATCH AND PREP WALLS WHERE DEMOLITION
OCCURS ADJACENT AN EXISTING WALL. TERMINATE
PLUMBING AT THE NEAREST LOCATION.
REUSE EXISTING FIXTURES IF IN GOOD CONDITION.
1
1
AREA NOT IN CONTRACT
AREA OF WORK
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDD101
SECOND FLOOR
DEMOLITION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 REMOVE RAILING.
3/16" = 1'-0"
SECOND FLOOR DEMOLITION PLAN 1 MARK DATE DESCRIPTION09/16/20
1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8"
DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F.
2. REMOVE ALL LIGHT FIXTURES. REFERENCE REFLECTED CEILING
PLAN A201.
3. PATCH CORE DRILLS/HOLES IN FLOOR AS REQUIRED.
4. REMOVE HVAC DIFFUSERS AND RETURNS AS REQUIRED. REUSE
FIXTURES IN GOOD CONDITION.
5. REMOVE ALL EXISTING FINISHES. REFERENCE FINISH PLAN A400
FOR FINAL FINISH PLAN.
GENERAL NOTES
LEGEND
NEW CONSTRUCTION
SOLID LINES INDICATE EXISTING ITEMS TO REMAIN.
NOTE: REFERENCE THE COVER SHEET FOR GENERAL
DEMOLITION NOTES.
KEYED NOTES
DASHED LINES AND SYMBOLS INDICATE EXISTING
ITEMS TO BE REMOVED OR SALVAGED. REFERENCE
PLAN NOTES.
PATCH AND PREP WALLS WHERE DEMOLITION
OCCURS ADJACENT AN EXISTING WALL. TERMINATE
PLUMBING AT THE NEAREST LOCATION.
REUSE EXISTING FIXTURES IF IN GOOD CONDITION.
AREA NOT IN CONTRACT
AREA OF WORK
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDD102
THIRD FLOOR
DEMOLITION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 REMOVE RAILING.
3/16" = 1'-0"
THIRD FLOOR DEMOLITION PLAN 1 MARK DATE DESCRIPTION09/16/20
UP
DOWN
DOWN
1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE
TYPE A3S.
2. PROVIDE NEW BLINDS ON EXTERIOR WINDOWS. BLINDS TO BE DRAPER M SCREEN,
COLOR: CHARCOAL, CONTACT TEDD CONNELL AT PATRIOT SOLUTIONS. VERIFY
WIDTH AND HEIGHT IN FIELD.
3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS
SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM
ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL
SUPPORT.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE
INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM
LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION.
6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN
ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS.
GENERAL NOTES
KEYED NOTES
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES
LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED
CEILING PLAN FOR CEILING HEIGHTS.
WALL TYPES
DESIGN STUDIO
222
MEETING
220 JENNIFER'S OFFICE
219
MEETING
221
OPEN OFFICE
210
TODD'S OFFICE
209
OFFICE
208
SMALL CONFERENCE
207
SMALL CONFERENCE
206
OFFICE
205
GUEST R.R.
204
JAN.
203
OFFICE STORAGE
202
GUEST R.R.
201
STRG.
223
ACCT. STRG.
224
COPY
227
HVAC
226
SEMI-PRIVATE OFFICE
214
SERVER
215 OSM
216
STUDIO STORAGE
218
OSM
217
OFFICE
211
OFFICE
212
OFFICE
213
RECEPTION
200
210 205206207208209213 212211226
224
223
200222218221
220
219217
216
2
4
1UCREFDISPLAY
DISPLAY
DISPLAY
DISPLAYDISPLAY
3
35/A500 6/A500A500
1
COFFEE
225
3
6
6
5
5
7 7
201
202
203
204
215
3
LOCATION TBD
9
9 9
9
9
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
X1
DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
DOOR AND
FRAME
WALLWALL
AREA NOT IN CONTRACT
AREA OF WORK
PLUMBING RISER DIAGRAM
TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE
MA
I
N BL
D
G
.
W
A
STE
2" W
A
S
T
E
TO
C.O.2" V.SINK
MAIN BLDG. VENT
2" VENT TO 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA101
SECOND FLOOR
PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 PROVIDE WATER LINE FOR COFFE. CONFIRM LOCATION WITH TENANT.
2 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR SINK AND
FAUCET. SINK- ELKAY, CROSSTOWN #ECTRU12179 (STAINLESS STEEL)
FAUCET - MOEN, SLEEK CHROME ONE-HANDLE HIGH ARC
MOTIONSENSE PULLDOWN KITCHEN FAUCET, MODEL: 7864EWC.
3 FIXED WALL MOUNTED TELEVISION SUPPLIED BY OWNER.
CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH
TENANT.
4 UNDERCOUNTER REFRIGERATOR SUPPLIED BY TENANT.
5 PROVIDE FULL GLASS PANES AROUND STAIRS. GLASS PANES TO BE
BUTT JOINTED WITH CLEAR SILICONE.
6 PROVIDE NEW METAL IRON RAILING WITH HORIZONTAL PICKETTS.
7 PROVIDE OPERABLE PARTITIONS WHERE SHOWN ON PLAN. PARTITIONS
TO BE HUFCOR OR EQUAL WITH STC RATIG OF 47 OR GREATER.
8 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND
FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL.
PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR GARBAGE
DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY, CROSSTOWN
#ECTRU24179R (STAINLESS STEEL) FAUCET- DELTA, MATEO
SINGLE-HANDLE PULL DOWN #9183-AR-DST (ARCTIC STAINLESS FINISH)
9 DISPLAY CABINETS PROVIDED BY TENANT.
3/16" = 1'-0"
SECOND FLOOR PLAN 1 MARK DATE DESCRIPTION09/16/20
1
1
1
1 1
1 6' - 10 1/2"10' - 4 1/2" 10' - 5"7' - 4 1/2" 15' - 8" +/- 19' - 10 5/8" 4' - 11"4' - 11" 4' - 10 7/8" 4' - 0 3/8" 7' - 3 5/8" 6' - 5 5/8" 10' - 4 1/2" 4' - 9" +/- 11' - 5" +/- 4' - 7" +/- 16' - 0" +/-21' - 9 7/8" +/-43' - 5 5/8" 5' - 8" 7' - 11 1/8"
6' - 1 7/8" 15' - 7 1/8" +/-5' - 0 1/2"
4' - 6 1/2" 10' - 11 1/8" +/-
1
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
X1
DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
DOOR AND
FRAME
WALLWALL
AREA NOT IN CONTRACT
AREA OF WORK
GENERAL NOTES
1. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO
PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS.
2. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS
NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN
TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR"
OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH
TO FACE OF FINISH.
KEYED NOTES
3/16" = 1'-0"
SECOND FLOOR DIMENSION PLAN 1 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA101D
SECOND FLOOR
DIMENSION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW
WALLS ARE IN LINE WITH EXISTING WALLS.MARK DATE DESCRIPTION09/16/20
1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE
TYPE A3S.
2. PROVIDE NEW BLINDS ON EXTERIOR WINDOWS. BLINDS TO BE DRAPER M SCREEN,
COLOR: CHARCOAL, CONTACT TEDD CONNELL AT PATRIOT SOLUTIONS. VERIFY
WIDTH AND HEIGHT IN FIELD.
3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS
SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM
ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL
SUPPORT.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE
INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM
LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION.
6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN
ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS.
GENERAL NOTES
KEYED NOTES
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES
LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED
CEILING PLAN FOR CEILING HEIGHTS.
WALL TYPES
MARKETING STORAGE
301
CONFERENCE
300
HVAC
302 301302
F
1 8
3 7/A500
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
X1
DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
DOOR AND
FRAME
WALLWALL
AREA NOT IN CONTRACT
AREA OF WORK
PLUMBING RISER DIAGRAM
TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE
MA
I
N BL
D
G
.
W
A
STE
2" W
A
S
T
E
TO
C.O.2" V.SINK
MAIN BLDG. VENT
2" VENT TO 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA102
THIRD FLOOR PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 PROVIDE WATER LINE FOR COFFE. CONFIRM LOCATION WITH TENANT.
2 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR SINK AND
FAUCET. SINK- ELKAY, CROSSTOWN #ECTRU12179 (STAINLESS STEEL)
FAUCET - MOEN, SLEEK CHROME ONE-HANDLE HIGH ARC
MOTIONSENSE PULLDOWN KITCHEN FAUCET, MODEL: 7864EWC.
3 FIXED WALL MOUNTED TELEVISION SUPPLIED BY OWNER.
CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH
TENANT.
4 UNDERCOUNTER REFRIGERATOR SUPPLIED BY TENANT.
5 PROVIDE FULL GLASS PANES AROUND STAIRS. GLASS PANES TO BE
BUTT JOINTED WITH CLEAR SILICONE.
6 PROVIDE NEW METAL IRON RAILING WITH HORIZONTAL PICKETTS.
7 PROVIDE OPERABLE PARTITIONS WHERE SHOWN ON PLAN. PARTITIONS
TO BE HUFCOR OR EQUAL WITH STC RATIG OF 47 OR GREATER.
8 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND
FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL.
PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR GARBAGE
DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY, CROSSTOWN
#ECTRU24179R (STAINLESS STEEL) FAUCET- DELTA, MATEO
SINGLE-HANDLE PULL DOWN #9183-AR-DST (ARCTIC STAINLESS FINISH)
9 DISPLAY CABINETS PROVIDED BY TENANT.
3/16" = 1'-0"
THIRD FLOOR PLAN 1 MARK DATE DESCRIPTION09/16/20
2' - 4 1/2"14' - 1 5/8"
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
X1
DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
DOOR AND
FRAME
WALLWALL
AREA NOT IN CONTRACT
AREA OF WORK
GENERAL NOTES
1. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO
PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS.
2. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS
NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN
TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR"
OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH
TO FACE OF FINISH.
KEYED NOTES
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA102D
THIRD FLOOR
DIMENSION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW
WALLS ARE IN LINE WITH EXISTING WALLS.
3/16" = 1'-0"
THIRD FLOOR PLAN DIMINSION PLAN 1 MARK DATE DESCRIPTION09/16/20
DOOR HARDWARE
AFB AUTOMATIC FLUSH BOLT
CH COAT HOOK
CR CARD READER BY TENANT (N.I.C.)
CL CLOSER
DB DEADBOLT
DL DUMMY LEVER
ES ELECTRIC STRIKE BY TENANT (N.I.C.)
H HOLD OPEN
KF KEY FOB
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
DOOR FRAME
1. PROVIDE NEW STAIN GRADE BIRCH VENEER MASONITE
DOORS AS REQUIRED. STAIN NEW DOORS TO COCOA BEAN.
PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS.
2. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE
POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING
STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON
NEW LOCK AND LATCHSETS.
3. PROVIDE NEW TIMELY TA-28 FRAMES AS REQUIRED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT
WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING
REQUIREMENTS AND LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE
SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL
ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC
HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS
AND INSTALLATIONS MUST COMPLY WITH THE INDIANA
BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
· 7'-0" HT. TO HAVE 3 HINGES
· GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
· FINISH TO MATCH HARDWARE SET
8. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS
OTHERWISE NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT
EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD
BLOCKING BEHIND WALL STOP.
10. PROVIDE COAT HOOK ON THE BACK OF ALL RESTROOM AND
OFFICE DOORS UNLESS NOTED OTHERWISE.
DOOR TYPES
FRAME TYPES
1/4" TEMPERED
GLASS
F1 F3 F4
D1D2 SEE SCHEDULE 2"2"
SEE SCHED.
2" 2"
2' - 3 3/4"
2"2" SEE SCHEDULE 2" SEE SCHED. 2"SEE SCHEDULESEE SCHED.SEE SCHEDULESEE SCHED.
6"
3/8" TEMPERED
GLASS
SEE SCHEDULE 2"2"
SEE SCHED.
2" 2"
3' - 8"
2"
6"
F5
3/8" TEMPERED
GLASS
SEE SCHEDULE 2"2"
SEE SCHED.
2" 2"
5' - 4"
2"
6"
F2
SEE SCHED.
FROSTED FILM
CENTERED ON
GLASS
FROSTED FILM
CENTERED ON
GLASS
FROSTED FILM
CENTERED ON
GLASS3' - 0"3' - 0"3' - 0"D3 SEE SCHEDULESEE SCHED.
SEE SCHED. SEE SCHED.SEE SCHEDULE3/8" TEMPERED
GLASS
BLACK METAL
U CHANNEL
BLACK METAL
U CHANNEL 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA110
DOOR SCHEDULESPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032DOOR SCHEDULE
DOOR NUMBER
ROOM PAIR POWER
REQUIRED
DOOR FRAME HARDWARE SET
COMMENTSWIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH
200 OPEN OFFICE 3' - 0" x 8' - 0" x 1 3/4" D3 SOLID CORE
WOOD/GLASS
STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL
201 GUEST R.R. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM SL
202 RECEPTION 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
203 RECEPTION 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
204 GUEST R.R. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL
205 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
206 SMALL
CONFERENCE
3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
207 SMALL
CONFERENCE
3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
208 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
209 TODD'S OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL
210
STAIRS
3' - 0" x 9' - 0" x 3/8" D2 GLASS - F2 - - CL,CR,ML,PP CONFIRM PUSH/PULL HARDWARE (BOTH SIDES
OF DOOR) WITH TENANT, LANDLORD AND
DESIGNER.
211 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
212 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
213 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
215 SERVER 3' - 0" x 7' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 EXISTING CL,SL
216 OSM 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F3 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
217 OSM 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F3 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
218 STUDIO STORAGE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL
219 JENNIFER'S OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL
220 MEETING 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
221 MEETING 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
222
STAIRS
3' - 0" x 9' - 0" x 3/8" D2 GLASS - F2 - - CL,CR,ML,PP CONFIRM PUSH/PULL HARDWARE (BOTH SIDES
OF DOOR) WITH TENANT, LANDLORD AND
DESIGNER.
223 STRG. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL
224 ACCT. STRG. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL
226 HVAC 3' - 0" x 8' - 0" x 1 3/4" D1 SOLOID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS
301 MARKETING
STORAGE
3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL
302 CONFERENCE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS MARK DATE DESCRIPTION09/16/20
D D D D DDDD D D
DD
DDDDD D DD D3D3
D3 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL
CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F.
2. REMOVE ALL LIGHT FIXTURES AND PROVIDE 4" SQUARE RECESSED CAN LIGHTING
THROUGHOUT. COLOR TEMPERATURE TO BE 3500K.
3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVERPLATE.
4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND
IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY
POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO
BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL
WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE
FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED
WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY
SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY
WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED
SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED.
PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS
REQUIRED.
7. ALL DEVICES AND COVERS TO BE WHITE.
8. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE.
GENERAL NOTESLEGEND
KEYED NOTES
X
X' -X"
CEILING TYPE
CEILING HEIGHT
GYPSUM BOARD CEILING
PAINTED WHITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS
PANELS REQUIRED FOR MAINTENANCE -LOCATIONS SHALL BE APPROVED BY
PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL
BULKHEAD CONDITIONS. SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS.
A
INDICATES NIGHT LIGHT
LOCATIONNL
EXIT LIGHT FIXTURE
EMERGENCY LIGHT
FIXTURE
NEW GYPSUM BOARD CEILING
LIGHT SWITCH
LIGHT SWITCH,
3-WAY
LIGHT SWITCH,
4-WAY
LIGHT SWITCH,
DIMMER
LIGHT CIRCUIT
3
4
D
4" SQUARE RECESSED CAN LIGHT
MFG: HALO
MODEL: PRS4 SMF48FS
COLOR: WHITE 3500K
EL
EXISTING GYPSUM BOARD
CEILING
PENDANT FIXTURE, 24" DIAMETER
($700 MATERIAL
ALLOWANCE/FIXTURE)
LED UNDER CABINET LIGHTING
MFG: HALO
MODEL: HU11
C1
P1
L1
LED WALL SCONCES1
PENDANT FIXTURE, 6" -8" DIAMETER
($450 MATERIAL
ALLOWANCE/FIXTURE)
P2
C1 C1
C1C1
C1 C1
C1 C1 C1 C1
C1
C1
C1
C1 C1 C1 C1 C1 C1
C1
C1
C1
C1
C1 C1
C1
C1
C1 C1
4' - 0"
4' - 0"
5' - 0" 5' - 0"5' - 0"
C1 C1
C1C1
5' - 0"5' - 0"C1 C1
C1 C1 3' - 6" 3' - 6" C1 C1
5' - 0"
C1C1
C1C1 3' - 6" 3' - 6" C1C1
C1C1
C1C1
C1 C1
5' - 0"3' - 6" 3' - 6" 3' - 0"3' - 6"5' - 6"7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
C1 C1
C1 C1
5' - 0" 5' - 0"C1 C1
C1 C1
5' - 0" 5' - 0"C1C1
C1C1
5' - 0"5' - 0"C1
C1
C1
C1C1
C1C1
3' - 0"
3' - 0"5' - 0" 5' - 0"5' - 6" L1
P1
L1
P1
P1
C1
C1
C1
C1
C1
C1
5' - 0"3' - 6"3' - 6"C1
C15' - 0"C1
C1C1
C1
5' - 0"5' - 0"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C15' - 0"5' - 0"5' - 0" 5' - 0"5' - 0"5' - 0" 5' - 0" 5' - 0"5' - 0" 5' - 0"3' - 0"
C1
5' - 0"
C1
C1
C1
C1
C1
7' - 6"5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0"C1
C1
C1
C1
C15' - 0" 5' - 0" 5' - 0" 5' - 0"GYP
9' -6"
GYP
9' - 10"
GYP
9' - 10"
GYP
9' - 10"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 C1
C1
C1
C1
C1
C1
C15' - 0" 5' - 0"4' - 0"5' - 0" 5' - 0" 5' - 0"4' - 0"5' - 6" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 4' - 1 1/2"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0" 7' - 0"2
1
1
1
2
2 ELEL
ELELNL
NL
NL
NL
NL
S1S1
5' - 0" 5' - 0"
P2
P2
P2
P2
AREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA201
SECOND FLOOR
REFLECTED
CEILING PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF
2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1.
2 CENTER PENDANTS OVER ISLAND. REFER TO FLOOR PLAN AND
CONFIRM FINAL LOCATION WITH TENANT.
3/16" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN 1 MARK DATE DESCRIPTION09/16/20
DDD
1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL
CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F.
2. REMOVE ALL LIGHT FIXTURES AND PROVIDE 4" SQUARE RECESSED CAN LIGHTING
THROUGHOUT. COLOR TEMPERATURE TO BE 3500K.
3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVERPLATE.
4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND
IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY
POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO
BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL
WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE
FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED
WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY
SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY
WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED
SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED.
PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS
REQUIRED.
7. ALL DEVICES AND COVERS TO BE WHITE.
8. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE.
GENERAL NOTESLEGEND
KEYED NOTES
X
X' -X"
CEILING TYPE
CEILING HEIGHT
GYPSUM BOARD CEILING
PAINTED WHITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS
PANELS REQUIRED FOR MAINTENANCE -LOCATIONS SHALL BE APPROVED BY
PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL
BULKHEAD CONDITIONS. SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS.
A
INDICATES NIGHT LIGHT
LOCATIONNL
EXIT LIGHT FIXTURE
EMERGENCY LIGHT
FIXTURE
NEW GYPSUM BOARD CEILING
LIGHT SWITCH
LIGHT SWITCH,
3-WAY
LIGHT SWITCH,
4-WAY
LIGHT SWITCH,
DIMMER
LIGHT CIRCUIT
3
4
D
4" SQUARE RECESSED CAN LIGHT
MFG: HALO
MODEL: PRS4 SMF48FS
COLOR: WHITE 3500K
EL
EXISTING GYPSUM BOARD
CEILING
PENDANT FIXTURE, 24" DIAMETER
($700 MATERIAL
ALLOWANCE/FIXTURE)
LED UNDER CABINET LIGHTING
MFG: HALO
MODEL: HU11
C1
P1
L1
LED WALL SCONCES1
PENDANT FIXTURE, 6" -8" DIAMETER
($450 MATERIAL
ALLOWANCE/FIXTURE)
P2
P1 P1 P1
4' - 6" 4' - 6"7' - 0" 7' - 0"5' - 0" 5' - 0" 5' - 0" 5' - 0"7' - 0"EQ.EQ. EQ. EQ.
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
L1
2 2 2 ELAREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA202
THIRD FLOOR
REFLECTED
CEILING PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF
2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1.
2 CENTER PENDANTS OVER ISLAND. REFER TO FLOOR PLAN AND
CONFIRM FINAL LOCATION WITH TENANT.
3/16" = 1'-0"
THIRD FLOOR REFLECTED CEILING PLAN 1 MARK DATE DESCRIPTION09/16/20
UP
DED +44 +44GFI+44DEDGFI
+44
GFI
+44
+60+60+60HD+60+60+60HD+60+60+60HDEXEX EX EXEX EX EXEX EX
EXEX EX EXEX EX
EXEX
EX EXEX EXEXGFI+44+44
+44+44 +44 +441. ALL OUTLETS, COVERS, SWITCHES, AND SWITCHPLATE COVERS TO
BE WHITE.
2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE
TEMINAL AT FACE PLATE.
3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI.
4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E.
MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN
SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL
ROOM.
5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSWISE.
6. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC
STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT
SPECIFIED BY PARALLEL DESIGN GROUP.
GENERAL NOTES
LEGEND
POWER OUTLET, DUPLEX
POWER OUTLET, QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED JUNCTION BOX
DATA/COMMUNICATION OUTLET (PROVIDE
BOX AND PULL STRING ONLY)
BOX, BLANK COVER PLATE
BOX, OPEN
P POWER AND DATA POLE
FLOOR BOX WITH JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER AND DATA,
FLUSH MOUNTED
NEW
EXISTING TO REMAIN
DEDICATED CIRCUIT
GROUND FAULT CIRCUIT INTERRUPT OUTLET
HEIGHT OF ELECTRICAL OR DATA DEVICE
N
EX
DED
GFI
+44"
J
B
O
J
DATA
JB
HD
CEILING MOUNTED POWER & HDMIHD
HD FLOOR BOX WITH POWER, DATA, & HDMI
FLUSH MOUNTED
SPECIAL PLUG
HDMI
KEY NOTES
RANGE PLUGR
OPEN OFFICE
210
TODD'S OFFICE
209
OFFICE
208
SMALL CONFERENCE
207
SMALL CONFERENCE
206OFFICE
205
COPY
227
HVAC
226
ACCT. STRG.
224
SEMI-PRIVATE OFFICE
214
SERVER
215 OSM
216
OSM
217
STUDIO STORAGE
218
MEETING
221
MEETING
220
JENNIFER'S OFFICE
219
DESIGN STUDIO
222
GUEST R.R.
201
OFFICE STORAGE
202
STRG.
223
JAN.
203
GUEST R.R.
204
RECEPTION
200
OFFICE
211
OFFICE
212
OFFICE
213
1
2
3
3
3
5 5
5
5
4
6
5
5
AREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA301
SECOND FLOOR
POWER AND DATAPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
SECOND FLOOR POWER & DATA 1
1 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
2 CONFIRM IT REQUIREMENTS WITH TENANT.
3 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION
SUPPLIED BY TENANT, CONTRACTOR INSTALLED. COORDINATE
EXACT LOCATION WITH TENANT.
4 PROVIDE POWER AS NEEDED FOR GARBAGE DISPOSAL.
5 PROVIDE FLUSH MOUNT 4" CORE DRILL FOR POWER AND DATA.
COORDINATE EXACT LOCATION WITH TENANT.
6 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED
UNDERCOUNTER FRIDGE.MARK DATE DESCRIPTION09/16/20
DED GFI
+44
GFI
+44
+60+60+60HD+44+44 EXEXEXEX EXEX EX1. ALL OUTLETS, COVERS, SWITCHES, AND SWITCHPLATE COVERS TO
BE WHITE.
2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE
TEMINAL AT FACE PLATE.
3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI.
4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E.
MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN
SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL
ROOM.
5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSWISE.
6. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC
STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT
SPECIFIED BY PARALLEL DESIGN GROUP.
GENERAL NOTES
LEGEND
POWER OUTLET, DUPLEX
POWER OUTLET, QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED JUNCTION BOX
DATA/COMMUNICATION OUTLET (PROVIDE
BOX AND PULL STRING ONLY)
BOX, BLANK COVER PLATE
BOX, OPEN
P POWER AND DATA POLE
FLOOR BOX WITH JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER AND DATA,
FLUSH MOUNTED
NEW
EXISTING TO REMAIN
DEDICATED CIRCUIT
GROUND FAULT CIRCUIT INTERRUPT OUTLET
HEIGHT OF ELECTRICAL OR DATA DEVICE
N
EX
DED
GFI
+44"
J
B
O
J
DATA
JB
HD
CEILING MOUNTED POWER & HDMIHD
HD FLOOR BOX WITH POWER, DATA, & HDMI
FLUSH MOUNTED
SPECIAL PLUG
HDMI
KEY NOTES
RANGE PLUGR
3
5
MARKETING STORAGE
301
CONFERENCE
300
HVAC
302
AREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA302
THIRD FLOOR
POWER AND DATAPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
2 CONFIRM IT REQUIREMENTS WITH TENANT.
3 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION
SUPPLIED BY TENANT, CONTRACTOR INSTALLED. COORDINATE
EXACT LOCATION WITH TENANT.
4 PROVIDE POWER AS NEEDED FOR GARBAGE DISPOSAL.
5 PROVIDE FLUSH MOUNT 4" CORE DRILL FOR POWER AND DATA.
COORDINATE EXACT LOCATION WITH TENANT.
6 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED
UNDERCOUNTER FRIDGE.
3/16" = 1'-0"
THIRD FLOOR POWER & DATA 1 MARK DATE DESCRIPTION09/16/20
DESIGN STUDIO
222
LVT1
PT1
VB1
GUEST R.R.
201
T1
PT1
TB1
OFFICE
STORAGE
202
LVT1
PT1
VB1
JAN.
203
LVT1
PT1
VB1
GUEST R.R.
204
T1
PT1
TB1
RECEPTION
200
LVT1
PT1
VB1
OPEN OFFICE
210
LVT1
PT1
VB1
MEETING
220
LVT1
PT1
VB1
JENNIFER'S
OFFICE
219
CPT1
PT1
VB1
MEETING
221
LVT1
PT1
VB1
STUDIO
STORAGE
218
LVT1
PT1
VB1
OSM
217
LVT1
PT1
VB1
OSM
216
LVT1
PT1
VB1
SERVER
215
CPT1
PT1
VB1
SEMI-PRIVATE
OFFICE
214
PT1
VB1
OFFICE
211
CPT1
PT1
VB1
OFFICE
212
CPT1
PT1
VB1
OFFICE
213
CPT1
PT1
VB1
COPY
227
LVT1
PT1
VB1
HVAC
226
LVT1
PT1
VB1
ACCT. STRG.
224
LVT1
PT1
VB1
STRG.
223
LVT1
PT1
VB1
TODD'S OFFICE
209
CPT1
PT1
VB1
OFFICE
208
CPT1
PT1
VB1SMALL
CONFERENCE
207
LVT1
PT1
VB1
SMALL
CONFERENCE
206
LVT1
PT1
VB1
OFFICE
205
LVT1
PT1
VB1
STAIRS
202
CPT2
PT1
VB1
STAIRS
201
CPT2
PT1
VB1
LVT1XCPT1MFG: TBD
TYPE: CARPET TILE
PATTERN: TBD
COLOR: TBD
INSTALLATION: TBD
CONTACT: TBD
FINISH SPECIFICATIONS
CPT1
CPT2
CARPET
LVT1 MFG: TBD
SIZE: TBD
PATTERN: TBD
COLOR: TBD
MFG: TBD
SIZE: TBD
COLOR: TBD
GROUT: TEC POWER GROUT-COLOR TBD
(WALLS ONLY)
CONTACT: TBD
WT2
LUXURY VINYL TILE
MFG: TEC
COLOR: TBD
TYPE: POWER GROUT
LOCATION: USED WITH PTX
GROUT
GT1
MFG: JOHNSONITE
TYPE: 4" MILLWORK BASE -REVEAL PROFILE
COLOR: TBD
WALL BASE
VB1
MFG: SHERWIN WILLIAMS
COLOR: SW 7005 PURE WHITE
FINISH: EGGSHELL
PAINT
PT1
PT2
PT3
MFG: TBD
COLOR: TBD
(CABINETRY SURFACES AS NOTED)
PLASTIC LAMINATE + SOLID SURFACES
PL1
MFG: TBD
COLOR: TBD
(COUNTERTOP SURFACES AS NOTED)
QTZ1
MFG: TBD
TYPE: CARPET TILE
PATTERN: TBD
COLOR: TBD
INSTALLATION: TBD
CONTACT: TBD
MFG: SHERWIN WILLIAMS
COLOR: SW 7069 IRON ORE
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
COLOR: TBD
FINISH: EGGSHELL
CERAMIC / GLASS WALL TILE
MFG: (FIELD TILE IN RESTROOMS)
SIZE: TBD
COLOR: TBD
GROUT: TEC POWER GROUT-COLOR TBD
(WALLS ONLY)
CONTACT: TBD
WT1
T1
FLOOR TILE
MFG: (FIELD FLOOR IN RESTROOMS)
SIZE: TBD
COLOR: TBD
CONTACT: TBD
MFG: TBD
TYPE: TBD
COLOR: TBD
TB1
MFG: TBD
COLOR: TBD
(COUNTERTOP SURFACES AS NOTED)
QTZ2
PL2 MFG: TBD
COLOR: TBD
(CABINETRY SURFACES AS NOTED)
1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE A THREE-COAT
SYSTEM, PRIMER COAT AND TWO (2) FINISH COATS.
2. THE FINISHES AT TIME OF THE ISSUE DATE HAVE BEEN CHECKED
AND ARE AVAILABLE UNLESS OTHERWISE NOTED.
WALLCOVERING, CARPET, CERAMIC TILE AND SPECIALTY ITEMS
CAN BE UP TO 6-8WEEK LEAD TIME.
PARALLEL DESIGN GROUP STRONGLY RECOMMENDS ORDERING
FINISHES IMMEDIATELY TO ENSURE TIMELY DELIVERY FOR AN ON-
TIME INSTALATION.
3. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH.
4. ALL FINISHES AND SPECIFICATIONS ARE TO BE SUBMITTED TO
PARALLEL DESIGN GROUP FOR FINAL APPROVAL PRIOR TO
ORDERING FINISH MATERIALS.
5. ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY
WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE.
6. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON
THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER PLANS.
7. ALL FINISHES TO COMPLY WITH APPLICABLE CODES.
8. PT1 AND VB1 TO BE USED THROUGHOUT UNLESS OTHERWISE
NOTED.
9. REPRESENTS DIRECTION OF FLOORING
10. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON
THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER FLOORS
FOR.
GENERAL NOTES
FINISH PLAN TAG
ROOM NAME
ROOM NUMBER
FLOOR BASE
WALL
KEY NOTES
3/16" = 1'-0"
SECOND FLOOR FINISH PLAN 1 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA401
SECOND FLOOR
FINISH PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 NEW CARPET ON STAIRS.
2 PAINT EXISTING HANDRAIL.MARK DATE DESCRIPTION09/16/20
1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE A THREE-COAT
SYSTEM, PRIMER COAT AND TWO (2) FINISH COATS.
2. THE FINISHES AT TIME OF THE ISSUE DATE HAVE BEEN CHECKED
AND ARE AVAILABLE UNLESS OTHERWISE NOTED.
WALLCOVERING, CARPET, CERAMIC TILE AND SPECIALTY ITEMS
CAN BE UP TO 6-8WEEK LEAD TIME.
PARALLEL DESIGN GROUP STRONGLY RECOMMENDS ORDERING
FINISHES IMMEDIATELY TO ENSURE TIMELY DELIVERY FOR AN ON-
TIME INSTALATION.
3. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH.
4. ALL FINISHES AND SPECIFICATIONS ARE TO BE SUBMITTED TO
PARALLEL DESIGN GROUP FOR FINAL APPROVAL PRIOR TO
ORDERING FINISH MATERIALS.
5. ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY
WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE.
6. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON
THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER PLANS.
7. ALL FINISHES TO COMPLY WITH APPLICABLE CODES.
8. PT1 AND VB1 TO BE USED THROUGHOUT UNLESS OTHERWISE
NOTED.
9. REPRESENTS DIRECTION OF FLOORING
10. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON
THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER FLOORS
FOR.
GENERAL NOTES
FINISH PLAN TAG
ROOM NAME
ROOM NUMBER
FLOOR BASE
WALL
KEY NOTES
MFG: TBD
TYPE: CARPET TILE
PATTERN: TBD
COLOR: TBD
INSTALLATION: TBD
CONTACT: TBD
FINISH SPECIFICATIONS
CPT1
CPT2
CARPET
LVT1 MFG: TBD
SIZE: TBD
PATTERN: TBD
COLOR: TBD
MFG: TBD
SIZE: TBD
COLOR: TBD
GROUT: TEC POWER GROUT-COLOR TBD
(WALLS ONLY)
CONTACT: TBD
WT2
LUXURY VINYL TILE
MFG: TEC
COLOR: TBD
TYPE: POWER GROUT
LOCATION: USED WITH PTX
GROUT
GT1
MFG: JOHNSONITE
TYPE: 4" MILLWORK BASE -REVEAL PROFILE
COLOR: TBD
WALL BASE
VB1
MFG: SHERWIN WILLIAMS
COLOR: SW 7005 PURE WHITE
FINISH: EGGSHELL
PAINT
PT1
PT2
PT3
MFG: TBD
COLOR: TBD
(CABINETRY SURFACES AS NOTED)
PLASTIC LAMINATE + SOLID SURFACES
PL1
MFG: TBD
COLOR: TBD
(COUNTERTOP SURFACES AS NOTED)
QTZ1
MFG: TBD
TYPE: CARPET TILE
PATTERN: TBD
COLOR: TBD
INSTALLATION: TBD
CONTACT: TBD
MFG: SHERWIN WILLIAMS
COLOR: SW 7069 IRON ORE
FINISH: EGGSHELL
MFG: SHERWIN WILLIAMS
COLOR: TBD
FINISH: EGGSHELL
CERAMIC / GLASS WALL TILE
MFG: (FIELD TILE IN RESTROOMS)
SIZE: TBD
COLOR: TBD
GROUT: TEC POWER GROUT-COLOR TBD
(WALLS ONLY)
CONTACT: TBD
WT1
T1
FLOOR TILE
MFG: (FIELD FLOOR IN RESTROOMS)
SIZE: TBD
COLOR: TBD
CONTACT: TBD
MFG: TBD
TYPE: TBD
COLOR: TBD
TB1
MFG: TBD
COLOR: TBD
(COUNTERTOP SURFACES AS NOTED)
QTZ2
PL2 MFG: TBD
COLOR: TBD
(CABINETRY SURFACES AS NOTED)
MARKETING
STORAGE
301
ETR
ETR
ETR
CONFERENCE
300
LVT
PT1
VB1
HVAC
302
ETR
ETR
ETR 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA402
THIRD FLOOR
FINISH PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
THIRD FLOOR FINISH PLAN 1
1 NEW CARPET ON STAIRS.
2 PAINT EXISTING HANDRAIL.1
2 MARK DATE DESCRIPTION09/16/20
MILL/CASEWORK NOTES
1. CAULK SELECTIONS ARE TO BE PROVIDED TO PARALLEL
DESIGN GROUP FOR SELECTION AND/OR APPROVAL BEFORE
INSTALLATION OF MILLWORK.
2. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR
PAINTED AS SPECIFIED) TO PARALLEL DESIGN GROUP FOR
REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS
OF ALL MILLWORK.
3. CASEWORK AND MILLWORK GENERALLY INDICATED ON
THESE DRAWINGS ARE TO BE PROVIDED UNDER THE
GENERAL CONTRACT.
4. UNLESS INDICATED OTHERWISE, COMPLY WITH
ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT
STANDARDS FOR CUSTOM GRADE WOODWORK.
5. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND
CASEWORK FOR APPROVAL BY THE TENANT AND PARALLEL
DESIGN GROUP PRIOR TO FABRICATION.
6. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED,
VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF
AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO PARALLEL DESIGN GROUP THROUGH THE
GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO
CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS
UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT
OF THE DESIGN SHOWN ON THE DRAWINGS.
7. UNLESS OTHERWISE SHOWN, PROVIDE 25" DEEP, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES
WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED.
8. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT
INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED
STANDARD MOUNTING HEIGHTS FOR THE PARTICULAR
APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT
CHOICES TO PARALLEL DESIGN GROUPS FOR FINAL
DECISIONS.
9. PROVED CABINETRY HARDWARE:
MFG: RICHELIEU
PRODUCT: CONTEMPORARY METAL PULL
SIZE: 3 IN CENTER TO CENTER
FINISH: BRUSHED NICKEL
3/A5002/A5004/A500
3' - 6"1' - 4" 8' - 8 3/4" 4' - 2 1/4"
1' - 2" 8' - 6 1/8" 4' - 2 7/8"2' - 6"3' - 6"2' - 0" 8' - 11 7/8" 1' - 3"
COPIER
BY TENANT
WT22' - 6"1' - 6" 3' - 0" 2' - 6" 3/4"
HOLD
5' - 5"
1' - 3" 1' - 3" 3/4"3" 2' - 0" 2' - 0" 3"
WT2
3" 2' - 0" 2' - 3"1' - 8" 2' - 6"U.C.
REFRIGERATOR
BY TENANT 2' - 10" REF./FREEZER
BY TENANT
WT2
D / W
BY TENANT
WT2
10' - 2 3/4"3' - 0" 2 3/4"1' - 6"
HOLD
2' - 0"3' - 0"1' - 6" 2' - 0"
HOLD
3' - 6"1' - 6"3' - 0"2' - 0" 1' - 9" 3" 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA500
INTERIOR
ELEVATIONSPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/8" = 1'-0"
RECEPTION 200 - ENLARGED PLAN11/2" = 1'-0"
RECEPTION 200 - FRONT VIEW 21/2" = 1'-0"
RECEPTION 200 - BACK VIEW 3
1/2" = 1'-0"
COPY 22751/2" = 1'-0"
COFFEE 22561/2" = 1'-0"
LARGE CONFERENCE 300 7
4" VINYL BASE (VB1)
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
25"D QUARTZ COUNTERTOP (QTZ1)
UNDERCABINET LIGHTING,
CONCEAL WITH FASCIA (PL2).
FASCIA TO ALIGN WITH BOTTOM SHELF
12"D PLASTIC LAMINATE
UPPER CABINETS (PL2)
PLASTIC LAMINATE FILLER PANEL (PL1)
PLASTIC LAMINATE FILLER PANEL (PL2)
4" VINYL BASE (VB1)
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
25"D QUARTZ COUNTERTOP (QTZ1)
UNDERCABINET LIGHTING,
CONCEAL WITH FASCIA (PL2).
FASCIA TO ALIGN WITH BOTTOM SHELF
12"D PLASTIC LAMINATE
UPPER CABINETS (PL2)
PLASTIC LAMINATE FILLER PANEL (PL1)
PLASTIC LAMINATE FILLER PANEL (PL2)
4" VINYL BASE (VB1)
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
25"D QUARTZ COUNTERTOP (QTZ1)
PLASTIC LAMINATE FILLER PANEL (PL1)
24"D PLASTIC LAMINATE
PULL -OUT DOUBLE TRASH BINS (PL1)
SINGLE BOWL STAINLESS STEEL UNDERMOUNT
SINK AND FAUCET. SEE SHEET A101 FOR SPEC.
SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR
SINK AND FAUCET. SEE SHEET A101 FOR SPEC.
1/2" = 1'-0"
RECEPTION 200 - STORAGE 4
4" VINYL BASE (VB1)
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
25"D QUARTZ COUNTERTOP (QTZ2)
PLASTIC LAMINATE FILLER PANEL (PL1)
4" VINYL BASE (VB1)
24"D LOCKABLE PLASTIC LAMINATE
BASE CABINETS (PL1)
12"D QUARTZ TRANSACTION TOP (QTZ2)
25"D QUARTZ WORK SURFACE TOP (QTZ2)
REMOVABLE MELAMINE
PAINTED KNEE WALL (PT1)
4" VINYL BASE (VB1)
12"D QUARTZ
TRANSACTION TOP (QTZ2)
PAINTED KNEE WALL (PT1)
UNDERCABINET LIGHTING,
CONCEAL WITH FASCIA (PL2).
FASCIA TO ALIGN WITH BOTTOM SHELF
12"D PLASTIC LAMINATE
UPPER CABINETS (PL2)
PLASTIC LAMINATE FILLER PANEL (PL2)MARK DATE DESCRIPTION09/16/20