Loading...
HomeMy WebLinkAboutA000_CoverSheetPROJECT INFORMATION PROJECT SQUARE FOOTAGE REMODEL: NEW CONSTRUCTION: OCCUPANCY: CONSTRUCTION TYPE: TENANT/CLIENT REPRESENTATIVE SIGNATURE DATETENANT/CLIENT REPRESENTATIVE NAME PRINTED THE TENANT/CLIENT AGREES THAT THESE DRAWINGS AND SPECIFICATIONS REPRESENT THE ENTIRE SCOPE OF WORK FOR THE IMPROVEMENTS TO BE PROVIDED. THE TENANT/CLIENT'S SIGNATURE BELOW REPRESENTS ACCEPTANCE OF THE FINAL DESIGN. ANY CHANGES TO THIS SCOPE OF WORK INITIATED BY THE TENANT/CLIENT WILL CAUSE CHANGES IN THE TOTAL COST TO THE TENANT/CLIENT AND IN THE COMPLETION DATE FOR THE PROJECT. APPROVAL FOR CONSTRUCTION DRAWING INDEX PROJECT TEAM INTERIOR DESIGNER PARALLEL DESIGN GROUP 8801 RIVER CROSSING BLVD. SUITE 140 INDIANAPOLIS, IN 46240 PH 317.721.4399 briana@paralleldg.com ARCHITECT DESIGNPOINT INC. GEORGE SMALL 4676 ST. JOHN CIR. ZIONSVILLE, IN 46077 PH 317.289.8007 gsmall@designpointarchitects.com 5,766 SQFT YES NO (B)USINESS V-B 1. EACH CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH ALL ASPECTS OF THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BY OTHERS. THIS FAMILIARIZATION INCLUDES FULL AND COMPLETE UNDERSTANDING OF THE WORK DESCRIBED ON ALL SHEETS OF THE DRAWINGS. FAILURE BY THE CONTRACTOR TO BECOME COMPLETELY FAMILIAR OF ALL ASPECTS OF THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE MATERIALS ASSEMBLIES, OR SERVICES INDICATED IN THE CONTRACT DOCUMENTS. 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE. 3. FIELD VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO PARALLEL DESIGN GROUP BEFORE BEGINNING ANY CONSTRUCTION. 4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORKSITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. 5. GENERAL CONTRACTOR TO REVIEW DOCUMENTS IN DETAIL AND COMMUNICATE ANY ITEMS THAT MAY REQUIRE LEAD TIMES. CONTRACTOR TO COORDINATE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO TEAM ANY DECISIONS THAT NEED TO BE MADE TO KEEP PROJECT SCHEDULE ON TRACK. CONTRACTOR IS RESPONSIBLE FOR DELAYS WHEN LEAD TIMES ARE NOT PROPERLY COMMUNICATED TO OWNER AND PARALLEL DESIGN GROUP. 6. NO SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS/MATERIALS WILL BE ALLOWED WITHOUT PRIOR APPROVAL FROM PARALLEL DESIGN GROUP. PRODUCT CHANGE SUBMITTALS SHOULD BE COMMUNICATED TO PARALLEL DESIGN GROUP ALLOWING ADEQUATE TIME TO RESPOND. 7. CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 8. SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO PARALLEL DESIGN GROUP FOR APPROVAL ON ALL MATERIALS/PRODUCTS IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. 9. PROVIDE SUBMITTAL SHOP DRAWINGS IN A TIMELY FASHION TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 10. ALL MATERIAL AND EQUIPMENT OF INDUSTRY STANDARD QUALITY SPECIFIED OR NOT, AND WITH THE LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 11. EACH CONTRACTOR SHALL FULLY REVIEW DRAWING SHEETS TO FULLY UNDERSTAND NEW WORK AND EXISTING CONDITIONS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE IN ADDITION TO COORDINATING FULL EXTENT OF RESPONSIBILITIES WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 12. THE GENERAL CONTRACTOR IS REQUIRED TO PATCH AND REPAIR ANY DAMAGED EXISTING SURFACE TO MATCH NEW. 13. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 14. ALL EQUIPMENT, MATERIALS AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 15. EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 16. PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 17. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL TO FINISHED FACE OF WALL. 18. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 20. NOTE REGARDING PROJECTS WITHIN MARION COUNTY: LOCAL ORDINANCE REQUIRES ONE SET OF CONSTRUCTION DRAWINGS FOR CLASS 1 STRUCTURES, THAT ARE DESIGNED WITH A FIRE PROTECTION AND LIFE SAFETY SYSTEMS (I.E. FIRE ALARMS), BE SUBMITTED TO THE INDIANAPOLIS FIRE DEPARTMENT (IFD) FOR THE PURPOSE OF CONDUCTING A FIRE DEPARTMENT PLAN REVIEW AND ON-SITE INSPECTIONS. DRAWING SET SHOULD INCLUDE ARCH, STRUCT, MECH, ELEC, SPRINKLER, FIRE ALARM, AND SITE/CIVIL (WHERE APPLICABLE). DRAWINGS MAY BE DELIVERED OR MAILED TO THE IFD PLAN REVIEW DIVISION (1200 MADISON AVENUE, INDIANAPOLIS, IN 46225, ATTENTION: T.J. BURNS). INCLUDE THE DMD STRUCTURAL PERMIT NUMBER (STR-XXXXXX) WITH THE DRAWING SET. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SUBMISSION OF THESE DRAWINGS AND THE REQUIRED FEE TO THE IFD PLAN REVIEW DIVISION. CONTACT THE IFD WITH QUESTIONS REGARDING THIS REQUIREMENT (317-327-5529). GENERAL PROJECT NOTES DEMOLITION NOTES 1. ALL EXISTING EQUIPMENT, FIXTURES, ETC. SHALL REMAIN PROPERTY OF THE OWNER. ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION SHALL BE RETAINED FOR THE OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY THE OWNER SHALL BE DISPOSED. 2. CONTRACTOR TO VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS. DEMOLITION DRAWINGS ARE A REFERENCE TO AID CONTRACTOR IN EVALUATION OF THE EXTENT OF THE DEMOLITION, BUT SHALL NOT BE CONSIDERED ALL INCLUSIVE. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC. REFERENCE NEW CONSTRUCTION DRAWINGS TO DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. 3. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT PARALLEL DESIGN GROUP IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 4. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED OR NOTED FOR THE INSTALLATION OF THE NEW WORK. 5. EACH TRADE CONTRACTOR IS RESPONSIBLE TO REFER TO NEW CONSTRUCTION DRAWINGS FOR ADDITIONAL PATCHING AND PREPARATION WORK RELATED TO THE DEMOLITION ITEMS. 6. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 7. CHECK EXISTING FLOOR LEVEL BEFORE INSTALLATION OF NEW FLOORING. PREPARE FLOOR WITH CEMENTITIOUS LEVELING COMPOUND PRIOR TO INSTALLATION OF NEW FLOOR FINISH AS REQUIRED TO MAINTAIN LEVEL. 8. REMOVE ALL ITEMS ASSOCTIATED WITH DEMOLISHED WALL IF NOT NOTED OR SHOWN OTHERWISE. SALVAGE ANY ITEMS IS GOOD CONDITION FOR REUSE IN NEW CONSTRUCTION, e.g., OUTLETS. 9. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING SURFACES, MATERIALS, COMPONENTS, ETC. TO REMAIN OR BE RELOCATED. ANY DAMAGE TO THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND PARALLEL DESIGN GROUP AT NO ADDITIONAL EXPENSE TO THE OWNER.. 10. COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. ALWAYS ABIDE BY THE MOST RESTRICTIVE CODE. 11. THE CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED BY THE OWNER TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING OUT OF THE PROJECT AREA. THE OWNER SHALL CONFIRM ALL DUST PREVENTION MEASURE/LOCATIONS, AND SHALL DETERMINE ANY CHANGES TO THESE MEASURES. 12. REMOVE DUST AND DEBRIS FROM NEWLY EXPOSED SURFACES. 13. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 14. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS, DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY. 1. POWER AND COMMUNICATION PLAN IS TO SHOW ELECTRICAL, VOICE/DATA RECEPTACLES AND TV LOCATIONS. ELECTRICAL CONTRACTOR TO FIELD VERIFY LOAD CAPACITIES AND AVAILABILITY. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL ENGINEERING. 2. REFLECTED CEILING PLAN IS TO SHOW LIGHT FIXTURE, DIFFUSER AND SWITCH LOCATIONS ONLY. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY MECHANICAL OR ELECTRICAL ENGINEERING. 3. ELECTRICAL CONTRACTOR RESPONSIBLE FOR RELOCATION AND/OR ADDITION OF HORN STROBES, FIRE ALARM STATIONS AND EXIST SIGNS AS REQUIRED BY CODE. 4. VERIFY IF ANY SPECIAL EQUIPMENT WILL REQUIRE ADDITIONAL AIR FLOW. PROVIDE ADDITIONAL HVAC REQUIREMENTS AFTER APPROVAL FROM TENANT. REVISE ZONING AS NEEDED. 5. PLUMBING, FIRE SUPPRESSION, AND FIRE ALARM SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THE RESPECTIVE DESIGN/BUILD CONTRACTORS PER AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR RESPECTIVE SYSTEMS IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. COORDINATE WITH THE ARCHITECT IF ADDITIONAL INFORMATION IS REQUIRED IN ORDER TO DO THE WORK IN THE FIELD. PARALLEL DESIGN GROUP AND THEIR ARCHITECT ARE NOT RESPONSIBLE FOR ANY ENGINEERING FOR THESE SYSTEMS. 6. COORDINATE CIRCUITRY REQUIREMENTS FOR FURNITURE SYSTEMS WITH TENANT, BEFORE RUNNING WIRING TO JUNCTION BOXES. 7. CENTER IN CEILING TILES RECESSED DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS, UNLESS OTHERWISE NOTED. 8. REVIEW FIRE DETECTION DEVICE LOCATIONS WITH TENANT PRIOR TO INSTALLATION. 9. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. MECHANICAL & ELECTRICAL NOTES FIRE PROTECTION NOTES 1. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 2. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 3. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 4. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 1. ALL MATERIALS TO BE DELIVERED IN THEIR ORIGINAL PACKAGING WITH MANUFACTURER'S LABELS. CONTRACTOR WILL BE RESPONSIBLE FOR RECEIVING, STORING AND PROTECTING MATERIALS FROM ANY DAMAGE BY MOISTURE, WIND, SUN ABUSE, OR ANY HARMFUL EFFECTS. DAMAGED MATERIALS WILL BE REJECTED AND MUST BE REPLACED BY THE CONTRACTOR. 2. REMOVE ALL PLATES AND SWITCHES BEFORE PAINTING AND REATTACH AFTERWARDS. 3. ALL REMAINING PAINT (1 GALLON MINIMUM) TO BE LEFT WITH THE OWNER. 4. WALLCOVERING SHALL BE FROM THE SAME PRODUCTION RUN. 5. DO NOT LOCATE WALLCOVERING SEAMS ON CORNERS. WRAP 6" BEYOND INSIDE OR OUTSIDE CORNERS AS INDICATED ON THE FINISH PLAN WHERE CHANGE OF WALLCOVERING LOCATION OCCURS. 6. CONTRACTOR TO REMOVE EXCESS ADHESIVE IMMEDIATEDLY FROM SURFACE OR WALLCOVERING AS EACH JOINT OR SEAM IS MADE AND BEFORE PROCEEDING TO THE NEXT JOINT OR SEAM. 7. ALL WALLCOVERING SEAMS ARE TO BE CUT STRAIGHT. ASSURE INSTALLATION IS SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, BUBBLES, GAPS, AND/OR OVERLAPS. 8. FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) 9. TRANSITION OF DIFFERENT FLOORING MATERIALS SHALL OCCUR AT THE CENTERLINE OF THE DOOR. 10. CONTRACTOR TO PROVIDE AND INSTALL TRANSITION STRIP BETWEEN DISSIMILAR FLOORING MATERIALS. TRANSITION STRIP IS TO BE SCHLUTER OR EQUAL WITH BRUSHED ALUMINUM FINISH OR IS TO BE VINYL AND MATCH VINYL BASE COLOR (IE.: WHERE VCT MEETS CARPET). CONTRACTOR TO DETERMINE TYPE OF SCHLUTER STRIP BASED ON DISSIMILAR FLOORING MATERIALS. CONTRACTOR TO VERIFY TYPE OF TRANSITION WITH PARALLEL DESIGN, IF NOT NOTED, PRIOR TO PLACING ORDER. 11. SUBFLOOR MUST BE LEVEL, SOUND, RIGID, CLEAN/FREE OF ANY DEBRIS, AND PERMANENTLY DRY PRIOR TO INSTALLATION. THE INSTALLATION OF FINISH FLOORING MATERIALS SHALL SERVE AS ACCEPTANCE OF SLAB CONDITION. 12. FLOORING MATERIALS SHALL BE FROM THE SAME PRODUCTION RUN. 13. CONTRACTOR SHALL REPAIR, REFINISH OR TOUCH-UP SURFACES DAMAGED BY SUBSEQUENT WORK. (EXAMPLE: WHERE NEW OUTLETS/FIXTURES HAVE BEEN INSTALLED) 14. LOW VOC CONTENT PAINT AND ADHESIVES TO BE USED THROUGHOUT PROJECT. 15. REVIEW AND ABIDE BY ALL MANUFACTURER INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION OF FINISH MATERIALS. MANUFACTURER RECOMMENDED ADHESIVES/SEALANTS TO BE USED. 16. UPON COMPLETION OF ALL FINISH APPLICATIONS, ALL MATERIALS AND EQUIPMENT SHALL BE REMOVED. CONTRACTOR SHALL INSURE THAT ALL AREAS ARE LEFT CLEAN AND DAMAGE FREE. 17. ANY VARIATION IN PATTERN, TEXTURE, COLOR OR ANY OTHER DEFECT SHOULD BE BROUGHT TO THE ATTENTION OF PARALLEL DESIGN GROUP FOR DIRECTION AND APPROVAL. FINISH NOTES 10. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. 11. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS. AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. MECHANICAL & ELECTRICAL NOTES CONTINUED [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 [ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY]N ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN.2020.16907.30.2020BWSB & BDPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032PYATT BUILDERS 07.30.2020 CONSTRUCTION DOCUMENTS 630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOOR CARMEL, INDIANA 46032 COVER SHEET A000 A000 COVER SHEET A001 SECOND FLOOR LIFE SAFETY PLAN A002 THIRD FLOOR LIFE SAFETY PLAN A003 ACCESSIBILITY A004 WALL TYPES D101 SECOND FLOOR DEMOLITION PLAN A101 SECOND FLOOR PLAN A101D SECOND FLOOR DIMENSION PLAN D102 THIRD FLOOR DEMOLITION PLAN A102 THIRD FLOOR PLAN A102D THIRD FLOOR DIMENSION PLAN A110 DOOR SCHEDULES A120 ENLARGED RESTROOM PLANS A201 SECOND FLOOR REFLECTED CEILING PLAN A202 THIRD FLOOR REFLECTED CEILING PLAN A301 SECOND FLOOR POWER AND DATA A302 THIRD FLOOR POWER AND DATA A401 SECOND FLOOR FINISH PLAN A402 THIRD FLOOR FINISH PLAN A500 INTERIOR ELEVATIONS MAP_LOCATION Revision ScheduleDate Description09/16/20 SCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE. OCCUPANCY CLASSIFICATION: B (BUSINESS) CHANGE OF OCCUPANCY CLASS: NO TOTAL BUILDING AREA: 10,686 GROSS SF TOTAL AREA ON FLOOR: SECOND FLOOR: 4,920 SQ.FT. THIRD FLOOR: 846 SQ.FT. TOTAL PROJECT AREA: 5,766 SQ.FT. OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GENERAL OFFICE 3,552 100 35.5 CONFERENCE 1,081 15 72 STORAGE 202 300 .7 TOTAL OCCUPANTS IN PROJECT AREA:108.2 NUMBER OF REQUIRED EXITS: 2 MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300' SPRINKLER SYSTEM (YES/NO): YES-EXISTING TO REMAIN FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION DETAILS 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT -BUILDING EXIT LOCATION FIRE EXTINGUISHER EXIT SIGNAGE EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING, REFRENCE A200 FOR LOCATION. LEGEND EX FE EL NL EP AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE EX ELOFFICE 205 131 SF SMALL CONFERENCE 206 131 SF SMALL CONFERENCE 207 OFFICE 208 TODD'S OFFICE 209 OPEN OFFICE 210 OFFICE 213 OFFICE 212 OFFICE 211 COPY 227 9 SF HVAC 226 13 SF ACCT. STRG. 224 13 SF STRG. 223 29 SF OFFICE STORAGE 202 GUEST R.R. 201 GUEST R.R. 204 JAN. 203 RECEPTION 200 SEMI-PRIVATE OFFICE 214 49 SF SERVER 215 OSM 216 OSM 217 35 SF STUDIO STORAGE 218 87 SF MEETING 221 89 SF MEETING 220 JENNIFER'S OFFICE 219 DESIGN STUDIO 222 FEFE FE EX EL ELELELCOMMON PATH OF EGRESS = 8' EXIT ACCESS TRAVEL = 60' COFFEE 225 EXIT ACCESS TRAVEL = 117'COMMON PATH OF EGRESS = 24'EXIT ACCESS TRAVEL = 45'EXIT ACCESS TRAVEL = 51'EXIT ACCESS TRAVEL = 44'1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA001 SECOND FLOOR LIFE SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0" SECOND FLOOR LIFE SAFETY PLAN 1 MARK DATE DESCRIPTION09/16/20 SCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE. OCCUPANCY CLASSIFICATION: B (BUSINESS) CHANGE OF OCCUPANCY CLASS: NO TOTAL BUILDING AREA: 10,686 GROSS SF TOTAL AREA ON FLOOR: SECOND FLOOR: 4,920 SQ.FT. THIRD FLOOR: 846 SQ.FT. TOTAL PROJECT AREA: 5,766 SQ.FT. OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GENERAL OFFICE 3,552 100 35.5 CONFERENCE 1,081 15 72 STORAGE 202 300 .7 TOTAL OCCUPANTS IN PROJECT AREA:108.2 NUMBER OF REQUIRED EXITS: 2 MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300' SPRINKLER SYSTEM (YES/NO): YES-EXISTING TO REMAIN FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION DETAILS 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN.ELEX EXIT ACCESS TRAVEL = 46' 63 SF MARKETING STORAGE 301 643 SF CONFERENCE 300 20 SF HVAC 302 EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT -BUILDING EXIT LOCATION FIRE EXTINGUISHER EXIT SIGNAGE EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING, REFRENCE A200 FOR LOCATION. LEGEND EX FE EL NL EP AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA002 THIRD FLOOR LIFE SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0" THIRD FLOOR PLAN LIFE SAFETY 1 MARK DATE DESCRIPTION09/16/20 18"1 1/2" DIAMETER GRAB BAR, 1 1/2" MIN. GAP FROM WALL (TYPICAL) FOLD DOWN SHOWER SEAT 1 1/2" DIAMETER GRAB BAR, 1 1/2" MIN. GAP FROM WALL (TYPICAL) SOAP SHELF, WHERE INDICATED CONTROL AREA HAND HELD ADJUSTABLE SHOWER HEAD (ADA) TRANSFER ADA SHOWER 1' - 6" 1' - 6"3' - 4" 33" - 36"3' - 10"4' - 0 1/4"3' - 1 3/4" MAX32" MIN - 34" MAX19" MIN MAINTAIN MIN. ACCESSIBLE CLEARANCES AS DIMENSIONED 9" MIN 27" MIN ACCESSIBILITY ROLL-UNDER CLEARANCES T-SHAPED TURNING SPACEARMARMBASE MIN. 1' - 0" MIN. 3' - 0" MIN. 1' - 0"MIN.3' - 0"MIN.2' - 0"MIN. 5' - 0"MIN.5' - 0"X > 24"36" MIN. MANEUVERING CLEARANCE IN AN ALCOVE: FORWARD APPROACH X > 15"60" MIN. MANEUVERING CLEARANCE IN AN ALCOVE: PARALLEL APPROACH ELEVATION PLAN9"MAX. 6" 30" MIN.17"-25" TOE CLEARANCE 8" MIN.2' - 4" MIN.9" MIN.MIN. 11" MAX. 1' - 5"2' - 6" MIN.ELEVATION PLAN KNEE CLEARANCE 4" MAX.X > 27"X 80"³LIMITS OF PROTRUDING OBJECTS 27" MAX.X > 80"VERTICAL CLEARANCE 15" MIN.48" MAX.UNOBSTRUCTED FORWARD REACH 20" MAX.48" MAX.44" MAX.UNOBSTRUCTED HIGH FORWARD REACH A. B.32" MIN.36" MIN.32" MIN.36" MIN.24" MAX. 48" MIN. 24" MAX. CLEAR WIDTH OF AN ACCESSIBLE ROUTE (A) 180 DEGREE TURN (B) 180 DEGREE TURN (EXCEPTION)48" MIN.42" MIN. 42" MIN. X < 48" 36" MIN. 36" MIN. X < 48"60" MIN.CLEAR WIDTH AT TURN (C) FOLDING DOOR (A) HINGED DOOR (B) SLIDING DOOR 32" MIN. 32" MIN. 32" MIN.90°CLEAR WIDTH OF DOORWAYS (A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) FRONT APPROACH, PUSH SIDE DOOR PROVIDED WITH BOTH CLOSER AND LATCH (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PULL SIDE (F) HINGE APPROACH, PUSH SIDE (G) HINGE APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (H) LATCH APPROACH, PULL SIDE (I) LATCH APPROACH, PULL SIDE, DOOR PROVIDED WITH CLOSER (J) LATCH APPROACH, PUSH SIDE (K) LATCH APPROACH, PUSH SIDE, DOOR PROVIDED WITH CLOSER 18" MIN.48" MIN.12" MIN. 48" MIN.36" MIN. 60" MIN.42" MIN.54" MIN.42" MIN.22" MIN. 48" MIN.22" MIN.48" MIN.24" MIN. 54" MIN.24" MIN 24" MIN. 42" MIN.24" MIN.48" MIN.60" MIN.(A) PULL SIDE (B) PUSH SIDE (C) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH60" MIN.18" MIN.X > 8"48" MIN.X > 8"X > 8"12" MIN.48" MIN.MANEUVERING CLEARANCE AT RECESSED DOORS AND GATES (A) (B) (C) 48" MIN. 48" MIN.48" MIN. DOOR IN SERIES AND GATES IN SERIES (A) STAIRS (B) RAMPS (C) WALKING SURFACES34" - 38"34" - 38" 34" - 38"HANDRAIL HEIGHT 1 1/2" MIN.1 1/2" MIN.HANDRAIL CLEARANCE HANDRAIL PROJECTIONS BELOW GRIPPING SURFACE NOTE: X = TREAD DEPTH 12" MIN. 12" MIN. 12" MIN. X X TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS 5" MAX. 15" MIN. DRINKING FOUNTAIN SPOUT LOCATION 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA003 ACCESSIBILITYPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032MARK DATE DESCRIPTION09/16/20 A2 A3 WALL PARTITION TYPEPLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED A METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; BOTH SIDES, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL ELIMINATOR TRACK LINE OF STRUCTURE UNDERSIDE OF STRUCTURE CEILING GRID STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA 3 -3/4" 4 -7/8"3 -5/8" 2 -1/2" STC: NO SOUND WITH SOUND A2S A3SB2 B3 B6 B1 B1S WALL PARTITION TYPE 42" FINISHEDPLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED B METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; BOTH SIDES, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND B2S B3S B6S B8 NON- RATED NA9 -1/4"8" B8S UNDERSIDE OF STRUCTURE C2 C3 C6 C1 C1S WALL PARTITION TYPE 4"PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED C METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; ONE SIDE, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND C2S C3S C6S C8 NON- RATED NA 8 -5/8"8" C8S LATERAL BRACING AT 4'-0" O.C. MAX. E2 E3 E6 E1 E1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED E METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; ONE SIDE, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND E2S E3S E6S E8 NON- RATED NA 8 -5/8"8" E8S SEALANT AND BACKER ROD; ONE SIDE, CONT. D2 D3 D6 D1 D1S WALL PARTITION TYPE4"PLAN VIEW SECTION VIEWSECTION VIEW REMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED D METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; BOTH SIDES, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND D2S D3S D6S D8 NON- RATED NA9 -1/4"8" D8S LATERAL BRACING AT 4'-0" O.C. MAX. F2 F3 F6 F1 F1S WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW REMARKS REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED F METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER SEALANT AND BACKER ROD; BOTH SIDES, CONT. ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND F2S F3S F6S F8 9 -1/4" 8" F8S SEALANT AND BACKER ROD; BOTH SIDES, CONT. NON- RATED NA NON- RATED NA NON- RATED NA NON- RATED NA WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA004 WALL TYPESPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032MARK DATE DESCRIPTION09/16/20 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F. 2. REMOVE ALL LIGHT FIXTURES. REFERENCE REFLECTED CEILING PLAN A201. 3. PATCH CORE DRILLS/HOLES IN FLOOR AS REQUIRED. 4. REMOVE HVAC DIFFUSERS AND RETURNS AS REQUIRED. REUSE FIXTURES IN GOOD CONDITION. 5. REMOVE ALL EXISTING FINISHES. REFERENCE FINISH PLAN A400 FOR FINAL FINISH PLAN. GENERAL NOTES LEGEND NEW CONSTRUCTION SOLID LINES INDICATE EXISTING ITEMS TO REMAIN. NOTE: REFERENCE THE COVER SHEET FOR GENERAL DEMOLITION NOTES. KEYED NOTES DASHED LINES AND SYMBOLS INDICATE EXISTING ITEMS TO BE REMOVED OR SALVAGED. REFERENCE PLAN NOTES. PATCH AND PREP WALLS WHERE DEMOLITION OCCURS ADJACENT AN EXISTING WALL. TERMINATE PLUMBING AT THE NEAREST LOCATION. REUSE EXISTING FIXTURES IF IN GOOD CONDITION. 1 1 AREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDD101 SECOND FLOOR DEMOLITION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 REMOVE RAILING. 3/16" = 1'-0" SECOND FLOOR DEMOLITION PLAN 1 MARK DATE DESCRIPTION09/16/20 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F. 2. REMOVE ALL LIGHT FIXTURES. REFERENCE REFLECTED CEILING PLAN A201. 3. PATCH CORE DRILLS/HOLES IN FLOOR AS REQUIRED. 4. REMOVE HVAC DIFFUSERS AND RETURNS AS REQUIRED. REUSE FIXTURES IN GOOD CONDITION. 5. REMOVE ALL EXISTING FINISHES. REFERENCE FINISH PLAN A400 FOR FINAL FINISH PLAN. GENERAL NOTES LEGEND NEW CONSTRUCTION SOLID LINES INDICATE EXISTING ITEMS TO REMAIN. NOTE: REFERENCE THE COVER SHEET FOR GENERAL DEMOLITION NOTES. KEYED NOTES DASHED LINES AND SYMBOLS INDICATE EXISTING ITEMS TO BE REMOVED OR SALVAGED. REFERENCE PLAN NOTES. PATCH AND PREP WALLS WHERE DEMOLITION OCCURS ADJACENT AN EXISTING WALL. TERMINATE PLUMBING AT THE NEAREST LOCATION. REUSE EXISTING FIXTURES IF IN GOOD CONDITION. AREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDD102 THIRD FLOOR DEMOLITION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 REMOVE RAILING. 3/16" = 1'-0" THIRD FLOOR DEMOLITION PLAN 1 MARK DATE DESCRIPTION09/16/20 UP DOWN DOWN 1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE A3S. 2. PROVIDE NEW BLINDS ON EXTERIOR WINDOWS. BLINDS TO BE DRAPER M SCREEN, COLOR: CHARCOAL, CONTACT TEDD CONNELL AT PATRIOT SOLUTIONS. VERIFY WIDTH AND HEIGHT IN FIELD. 3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION. 6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS. GENERAL NOTES KEYED NOTES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WALL TYPES DESIGN STUDIO 222 MEETING 220 JENNIFER'S OFFICE 219 MEETING 221 OPEN OFFICE 210 TODD'S OFFICE 209 OFFICE 208 SMALL CONFERENCE 207 SMALL CONFERENCE 206 OFFICE 205 GUEST R.R. 204 JAN. 203 OFFICE STORAGE 202 GUEST R.R. 201 STRG. 223 ACCT. STRG. 224 COPY 227 HVAC 226 SEMI-PRIVATE OFFICE 214 SERVER 215 OSM 216 STUDIO STORAGE 218 OSM 217 OFFICE 211 OFFICE 212 OFFICE 213 RECEPTION 200 210 205206207208209213 212211226 224 223 200222218221 220 219217 216 2 4 1UCREFDISPLAY DISPLAY DISPLAY DISPLAYDISPLAY 3 35/A500 6/A500A500 1 COFFEE 225 3 6 6 5 5 7 7 201 202 203 204 215 3 LOCATION TBD 9 9 9 9 9 LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK PLUMBING RISER DIAGRAM TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE MA I N BL D G . W A STE 2" W A S T E TO C.O.2" V.SINK MAIN BLDG. VENT 2" VENT TO 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA101 SECOND FLOOR PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 PROVIDE WATER LINE FOR COFFE. CONFIRM LOCATION WITH TENANT. 2 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR SINK AND FAUCET. SINK- ELKAY, CROSSTOWN #ECTRU12179 (STAINLESS STEEL) FAUCET - MOEN, SLEEK CHROME ONE-HANDLE HIGH ARC MOTIONSENSE PULLDOWN KITCHEN FAUCET, MODEL: 7864EWC. 3 FIXED WALL MOUNTED TELEVISION SUPPLIED BY OWNER. CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 4 UNDERCOUNTER REFRIGERATOR SUPPLIED BY TENANT. 5 PROVIDE FULL GLASS PANES AROUND STAIRS. GLASS PANES TO BE BUTT JOINTED WITH CLEAR SILICONE. 6 PROVIDE NEW METAL IRON RAILING WITH HORIZONTAL PICKETTS. 7 PROVIDE OPERABLE PARTITIONS WHERE SHOWN ON PLAN. PARTITIONS TO BE HUFCOR OR EQUAL WITH STC RATIG OF 47 OR GREATER. 8 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR GARBAGE DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY, CROSSTOWN #ECTRU24179R (STAINLESS STEEL) FAUCET- DELTA, MATEO SINGLE-HANDLE PULL DOWN #9183-AR-DST (ARCTIC STAINLESS FINISH) 9 DISPLAY CABINETS PROVIDED BY TENANT. 3/16" = 1'-0" SECOND FLOOR PLAN 1 MARK DATE DESCRIPTION09/16/20 1 1 1 1 1 1 6' - 10 1/2"10' - 4 1/2" 10' - 5"7' - 4 1/2" 15' - 8" +/- 19' - 10 5/8" 4' - 11"4' - 11" 4' - 10 7/8" 4' - 0 3/8" 7' - 3 5/8" 6' - 5 5/8" 10' - 4 1/2" 4' - 9" +/- 11' - 5" +/- 4' - 7" +/- 16' - 0" +/-21' - 9 7/8" +/-43' - 5 5/8" 5' - 8" 7' - 11 1/8" 6' - 1 7/8" 15' - 7 1/8" +/-5' - 0 1/2" 4' - 6 1/2" 10' - 11 1/8" +/- 1 LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES 1. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS. 2. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR" OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. KEYED NOTES 3/16" = 1'-0" SECOND FLOOR DIMENSION PLAN 1 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA101D SECOND FLOOR DIMENSION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS.MARK DATE DESCRIPTION09/16/20 1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE A3S. 2. PROVIDE NEW BLINDS ON EXTERIOR WINDOWS. BLINDS TO BE DRAPER M SCREEN, COLOR: CHARCOAL, CONTACT TEDD CONNELL AT PATRIOT SOLUTIONS. VERIFY WIDTH AND HEIGHT IN FIELD. 3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION. 6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS. GENERAL NOTES KEYED NOTES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WALL TYPES MARKETING STORAGE 301 CONFERENCE 300 HVAC 302 301302 F 1 8 3 7/A500 LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK PLUMBING RISER DIAGRAM TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE MA I N BL D G . W A STE 2" W A S T E TO C.O.2" V.SINK MAIN BLDG. VENT 2" VENT TO 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA102 THIRD FLOOR PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 PROVIDE WATER LINE FOR COFFE. CONFIRM LOCATION WITH TENANT. 2 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR SINK AND FAUCET. SINK- ELKAY, CROSSTOWN #ECTRU12179 (STAINLESS STEEL) FAUCET - MOEN, SLEEK CHROME ONE-HANDLE HIGH ARC MOTIONSENSE PULLDOWN KITCHEN FAUCET, MODEL: 7864EWC. 3 FIXED WALL MOUNTED TELEVISION SUPPLIED BY OWNER. CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 4 UNDERCOUNTER REFRIGERATOR SUPPLIED BY TENANT. 5 PROVIDE FULL GLASS PANES AROUND STAIRS. GLASS PANES TO BE BUTT JOINTED WITH CLEAR SILICONE. 6 PROVIDE NEW METAL IRON RAILING WITH HORIZONTAL PICKETTS. 7 PROVIDE OPERABLE PARTITIONS WHERE SHOWN ON PLAN. PARTITIONS TO BE HUFCOR OR EQUAL WITH STC RATIG OF 47 OR GREATER. 8 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR GARBAGE DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY, CROSSTOWN #ECTRU24179R (STAINLESS STEEL) FAUCET- DELTA, MATEO SINGLE-HANDLE PULL DOWN #9183-AR-DST (ARCTIC STAINLESS FINISH) 9 DISPLAY CABINETS PROVIDED BY TENANT. 3/16" = 1'-0" THIRD FLOOR PLAN 1 MARK DATE DESCRIPTION09/16/20 2' - 4 1/2"14' - 1 5/8" LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES 1. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS. 2. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL UNLESS NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CLR" OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. KEYED NOTES 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA102D THIRD FLOOR DIMENSION PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. 3/16" = 1'-0" THIRD FLOOR PLAN DIMINSION PLAN 1 MARK DATE DESCRIPTION09/16/20 DOOR HARDWARE AFB AUTOMATIC FLUSH BOLT CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) CL CLOSER DB DEADBOLT DL DUMMY LEVER ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KF KEY FOB KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES DOOR FRAME 1. PROVIDE NEW STAIN GRADE BIRCH VENEER MASONITE DOORS AS REQUIRED. STAIN NEW DOORS TO COCOA BEAN. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW TIMELY TA-28 FRAMES AS REQUIRED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE 1 SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. 10. PROVIDE COAT HOOK ON THE BACK OF ALL RESTROOM AND OFFICE DOORS UNLESS NOTED OTHERWISE. DOOR TYPES FRAME TYPES 1/4" TEMPERED GLASS F1 F3 F4 D1D2 SEE SCHEDULE 2"2" SEE SCHED. 2" 2" 2' - 3 3/4" 2"2" SEE SCHEDULE 2" SEE SCHED. 2"SEE SCHEDULESEE SCHED.SEE SCHEDULESEE SCHED. 6" 3/8" TEMPERED GLASS SEE SCHEDULE 2"2" SEE SCHED. 2" 2" 3' - 8" 2" 6" F5 3/8" TEMPERED GLASS SEE SCHEDULE 2"2" SEE SCHED. 2" 2" 5' - 4" 2" 6" F2 SEE SCHED. FROSTED FILM CENTERED ON GLASS FROSTED FILM CENTERED ON GLASS FROSTED FILM CENTERED ON GLASS3' - 0"3' - 0"3' - 0"D3 SEE SCHEDULESEE SCHED. SEE SCHED. SEE SCHED.SEE SCHEDULE3/8" TEMPERED GLASS BLACK METAL U CHANNEL BLACK METAL U CHANNEL 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA110 DOOR SCHEDULESPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 46032DOOR SCHEDULE DOOR NUMBER ROOM PAIR POWER REQUIRED DOOR FRAME HARDWARE SET COMMENTSWIDTH x HEIGHT x THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH 200 OPEN OFFICE 3' - 0" x 8' - 0" x 1 3/4" D3 SOLID CORE WOOD/GLASS STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL 201 GUEST R.R. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM SL 202 RECEPTION 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 203 RECEPTION 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 204 GUEST R.R. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL 205 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 206 SMALL CONFERENCE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 207 SMALL CONFERENCE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 208 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 209 TODD'S OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL 210 STAIRS 3' - 0" x 9' - 0" x 3/8" D2 GLASS - F2 - - CL,CR,ML,PP CONFIRM PUSH/PULL HARDWARE (BOTH SIDES OF DOOR) WITH TENANT, LANDLORD AND DESIGNER. 211 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 212 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 213 OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F4 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 215 SERVER 3' - 0" x 7' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 EXISTING CL,SL 216 OSM 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F3 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 217 OSM 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F3 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 218 STUDIO STORAGE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL 219 JENNIFER'S OFFICE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM OL 220 MEETING 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 221 MEETING 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F5 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 222 STAIRS 3' - 0" x 9' - 0" x 3/8" D2 GLASS - F2 - - CL,CR,ML,PP CONFIRM PUSH/PULL HARDWARE (BOTH SIDES OF DOOR) WITH TENANT, LANDLORD AND DESIGNER. 223 STRG. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL 224 ACCT. STRG. 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL 226 HVAC 3' - 0" x 8' - 0" x 1 3/4" D1 SOLOID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS 301 MARKETING STORAGE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM CL,SL 302 CONFERENCE 3' - 0" x 8' - 0" x 1 3/4" D1 SOLID CORE WOOD STANDARD STAIN F1 TIMELY TA-28 BLACK ANODIZED ALUMINUM PS MARK DATE DESCRIPTION09/16/20 D D D D DDDD D D DD DDDDD D DD D3D3 D3 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F. 2. REMOVE ALL LIGHT FIXTURES AND PROVIDE 4" SQUARE RECESSED CAN LIGHTING THROUGHOUT. COLOR TEMPERATURE TO BE 3500K. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 7. ALL DEVICES AND COVERS TO BE WHITE. 8. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. GENERAL NOTESLEGEND KEYED NOTES X X' -X" CEILING TYPE CEILING HEIGHT GYPSUM BOARD CEILING PAINTED WHITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE -LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL BULKHEAD CONDITIONS. SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS. A INDICATES NIGHT LIGHT LOCATIONNL EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE NEW GYPSUM BOARD CEILING LIGHT SWITCH LIGHT SWITCH, 3-WAY LIGHT SWITCH, 4-WAY LIGHT SWITCH, DIMMER LIGHT CIRCUIT 3 4 D 4" SQUARE RECESSED CAN LIGHT MFG: HALO MODEL: PRS4 SMF48FS COLOR: WHITE 3500K EL EXISTING GYPSUM BOARD CEILING PENDANT FIXTURE, 24" DIAMETER ($700 MATERIAL ALLOWANCE/FIXTURE) LED UNDER CABINET LIGHTING MFG: HALO MODEL: HU11 C1 P1 L1 LED WALL SCONCES1 PENDANT FIXTURE, 6" -8" DIAMETER ($450 MATERIAL ALLOWANCE/FIXTURE) P2 C1 C1 C1C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 4' - 0" 4' - 0" 5' - 0" 5' - 0"5' - 0" C1 C1 C1C1 5' - 0"5' - 0"C1 C1 C1 C1 3' - 6" 3' - 6" C1 C1 5' - 0" C1C1 C1C1 3' - 6" 3' - 6" C1C1 C1C1 C1C1 C1 C1 5' - 0"3' - 6" 3' - 6" 3' - 0"3' - 6"5' - 6"7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" C1 C1 C1 C1 5' - 0" 5' - 0"C1 C1 C1 C1 5' - 0" 5' - 0"C1C1 C1C1 5' - 0"5' - 0"C1 C1 C1 C1C1 C1C1 3' - 0" 3' - 0"5' - 0" 5' - 0"5' - 6" L1 P1 L1 P1 P1 C1 C1 C1 C1 C1 C1 5' - 0"3' - 6"3' - 6"C1 C15' - 0"C1 C1C1 C1 5' - 0"5' - 0" C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C15' - 0"5' - 0"5' - 0" 5' - 0"5' - 0"5' - 0" 5' - 0" 5' - 0"5' - 0" 5' - 0"3' - 0" C1 5' - 0" C1 C1 C1 C1 C1 7' - 6"5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0"C1 C1 C1 C1 C15' - 0" 5' - 0" 5' - 0" 5' - 0"GYP 9' -6" GYP 9' - 10" GYP 9' - 10" GYP 9' - 10" C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C15' - 0" 5' - 0"4' - 0"5' - 0" 5' - 0" 5' - 0"4' - 0"5' - 6" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 4' - 1 1/2" C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0" 7' - 0"2 1 1 1 2 2 ELEL ELELNL NL NL NL NL S1S1 5' - 0" 5' - 0" P2 P2 P2 P2 AREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA201 SECOND FLOOR REFLECTED CEILING PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1. 2 CENTER PENDANTS OVER ISLAND. REFER TO FLOOR PLAN AND CONFIRM FINAL LOCATION WITH TENANT. 3/16" = 1'-0" SECOND FLOOR REFLECTED CEILING PLAN 1 MARK DATE DESCRIPTION09/16/20 DDD 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL CEILINGS THROUGHOUT AT 9' - 10" +/- A.F.F. 2. REMOVE ALL LIGHT FIXTURES AND PROVIDE 4" SQUARE RECESSED CAN LIGHTING THROUGHOUT. COLOR TEMPERATURE TO BE 3500K. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 7. ALL DEVICES AND COVERS TO BE WHITE. 8. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE. GENERAL NOTESLEGEND KEYED NOTES X X' -X" CEILING TYPE CEILING HEIGHT GYPSUM BOARD CEILING PAINTED WHITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE -LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL BULKHEAD CONDITIONS. SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS. A INDICATES NIGHT LIGHT LOCATIONNL EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE NEW GYPSUM BOARD CEILING LIGHT SWITCH LIGHT SWITCH, 3-WAY LIGHT SWITCH, 4-WAY LIGHT SWITCH, DIMMER LIGHT CIRCUIT 3 4 D 4" SQUARE RECESSED CAN LIGHT MFG: HALO MODEL: PRS4 SMF48FS COLOR: WHITE 3500K EL EXISTING GYPSUM BOARD CEILING PENDANT FIXTURE, 24" DIAMETER ($700 MATERIAL ALLOWANCE/FIXTURE) LED UNDER CABINET LIGHTING MFG: HALO MODEL: HU11 C1 P1 L1 LED WALL SCONCES1 PENDANT FIXTURE, 6" -8" DIAMETER ($450 MATERIAL ALLOWANCE/FIXTURE) P2 P1 P1 P1 4' - 6" 4' - 6"7' - 0" 7' - 0"5' - 0" 5' - 0" 5' - 0" 5' - 0"7' - 0"EQ.EQ. EQ. EQ. C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 L1 2 2 2 ELAREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA202 THIRD FLOOR REFLECTED CEILING PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1. 2 CENTER PENDANTS OVER ISLAND. REFER TO FLOOR PLAN AND CONFIRM FINAL LOCATION WITH TENANT. 3/16" = 1'-0" THIRD FLOOR REFLECTED CEILING PLAN 1 MARK DATE DESCRIPTION09/16/20 UP DED +44 +44GFI+44DEDGFI +44 GFI +44 +60+60+60HD+60+60+60HD+60+60+60HDEXEX EX EXEX EX EXEX EX EXEX EX EXEX EX EXEX EX EXEX EXEXGFI+44+44 +44+44 +44 +441. ALL OUTLETS, COVERS, SWITCHES, AND SWITCHPLATE COVERS TO BE WHITE. 2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TEMINAL AT FACE PLATE. 3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI. 4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E. MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL ROOM. 5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSWISE. 6. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. GENERAL NOTES LEGEND POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) BOX, BLANK COVER PLATE BOX, OPEN P POWER AND DATA POLE FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED NEW EXISTING TO REMAIN DEDICATED CIRCUIT GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE N EX DED GFI +44" J B O J DATA JB HD CEILING MOUNTED POWER & HDMIHD HD FLOOR BOX WITH POWER, DATA, & HDMI FLUSH MOUNTED SPECIAL PLUG HDMI KEY NOTES RANGE PLUGR OPEN OFFICE 210 TODD'S OFFICE 209 OFFICE 208 SMALL CONFERENCE 207 SMALL CONFERENCE 206OFFICE 205 COPY 227 HVAC 226 ACCT. STRG. 224 SEMI-PRIVATE OFFICE 214 SERVER 215 OSM 216 OSM 217 STUDIO STORAGE 218 MEETING 221 MEETING 220 JENNIFER'S OFFICE 219 DESIGN STUDIO 222 GUEST R.R. 201 OFFICE STORAGE 202 STRG. 223 JAN. 203 GUEST R.R. 204 RECEPTION 200 OFFICE 211 OFFICE 212 OFFICE 213 1 2 3 3 3 5 5 5 5 4 6 5 5 AREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA301 SECOND FLOOR POWER AND DATAPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0" SECOND FLOOR POWER & DATA 1 1 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. 2 CONFIRM IT REQUIREMENTS WITH TENANT. 3 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION SUPPLIED BY TENANT, CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 4 PROVIDE POWER AS NEEDED FOR GARBAGE DISPOSAL. 5 PROVIDE FLUSH MOUNT 4" CORE DRILL FOR POWER AND DATA. COORDINATE EXACT LOCATION WITH TENANT. 6 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED UNDERCOUNTER FRIDGE.MARK DATE DESCRIPTION09/16/20 DED GFI +44 GFI +44 +60+60+60HD+44+44 EXEXEXEX EXEX EX1. ALL OUTLETS, COVERS, SWITCHES, AND SWITCHPLATE COVERS TO BE WHITE. 2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TEMINAL AT FACE PLATE. 3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI. 4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E. MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL ROOM. 5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSWISE. 6. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. GENERAL NOTES LEGEND POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) BOX, BLANK COVER PLATE BOX, OPEN P POWER AND DATA POLE FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED NEW EXISTING TO REMAIN DEDICATED CIRCUIT GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE N EX DED GFI +44" J B O J DATA JB HD CEILING MOUNTED POWER & HDMIHD HD FLOOR BOX WITH POWER, DATA, & HDMI FLUSH MOUNTED SPECIAL PLUG HDMI KEY NOTES RANGE PLUGR 3 5 MARKETING STORAGE 301 CONFERENCE 300 HVAC 302 AREA NOT IN CONTRACT AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA302 THIRD FLOOR POWER AND DATAPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. 2 CONFIRM IT REQUIREMENTS WITH TENANT. 3 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION SUPPLIED BY TENANT, CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 4 PROVIDE POWER AS NEEDED FOR GARBAGE DISPOSAL. 5 PROVIDE FLUSH MOUNT 4" CORE DRILL FOR POWER AND DATA. COORDINATE EXACT LOCATION WITH TENANT. 6 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED UNDERCOUNTER FRIDGE. 3/16" = 1'-0" THIRD FLOOR POWER & DATA 1 MARK DATE DESCRIPTION09/16/20 DESIGN STUDIO 222 LVT1 PT1 VB1 GUEST R.R. 201 T1 PT1 TB1 OFFICE STORAGE 202 LVT1 PT1 VB1 JAN. 203 LVT1 PT1 VB1 GUEST R.R. 204 T1 PT1 TB1 RECEPTION 200 LVT1 PT1 VB1 OPEN OFFICE 210 LVT1 PT1 VB1 MEETING 220 LVT1 PT1 VB1 JENNIFER'S OFFICE 219 CPT1 PT1 VB1 MEETING 221 LVT1 PT1 VB1 STUDIO STORAGE 218 LVT1 PT1 VB1 OSM 217 LVT1 PT1 VB1 OSM 216 LVT1 PT1 VB1 SERVER 215 CPT1 PT1 VB1 SEMI-PRIVATE OFFICE 214 PT1 VB1 OFFICE 211 CPT1 PT1 VB1 OFFICE 212 CPT1 PT1 VB1 OFFICE 213 CPT1 PT1 VB1 COPY 227 LVT1 PT1 VB1 HVAC 226 LVT1 PT1 VB1 ACCT. STRG. 224 LVT1 PT1 VB1 STRG. 223 LVT1 PT1 VB1 TODD'S OFFICE 209 CPT1 PT1 VB1 OFFICE 208 CPT1 PT1 VB1SMALL CONFERENCE 207 LVT1 PT1 VB1 SMALL CONFERENCE 206 LVT1 PT1 VB1 OFFICE 205 LVT1 PT1 VB1 STAIRS 202 CPT2 PT1 VB1 STAIRS 201 CPT2 PT1 VB1 LVT1XCPT1MFG: TBD TYPE: CARPET TILE PATTERN: TBD COLOR: TBD INSTALLATION: TBD CONTACT: TBD FINISH SPECIFICATIONS CPT1 CPT2 CARPET LVT1 MFG: TBD SIZE: TBD PATTERN: TBD COLOR: TBD MFG: TBD SIZE: TBD COLOR: TBD GROUT: TEC POWER GROUT-COLOR TBD (WALLS ONLY) CONTACT: TBD WT2 LUXURY VINYL TILE MFG: TEC COLOR: TBD TYPE: POWER GROUT LOCATION: USED WITH PTX GROUT GT1 MFG: JOHNSONITE TYPE: 4" MILLWORK BASE -REVEAL PROFILE COLOR: TBD WALL BASE VB1 MFG: SHERWIN WILLIAMS COLOR: SW 7005 PURE WHITE FINISH: EGGSHELL PAINT PT1 PT2 PT3 MFG: TBD COLOR: TBD (CABINETRY SURFACES AS NOTED) PLASTIC LAMINATE + SOLID SURFACES PL1 MFG: TBD COLOR: TBD (COUNTERTOP SURFACES AS NOTED) QTZ1 MFG: TBD TYPE: CARPET TILE PATTERN: TBD COLOR: TBD INSTALLATION: TBD CONTACT: TBD MFG: SHERWIN WILLIAMS COLOR: SW 7069 IRON ORE FINISH: EGGSHELL MFG: SHERWIN WILLIAMS COLOR: TBD FINISH: EGGSHELL CERAMIC / GLASS WALL TILE MFG: (FIELD TILE IN RESTROOMS) SIZE: TBD COLOR: TBD GROUT: TEC POWER GROUT-COLOR TBD (WALLS ONLY) CONTACT: TBD WT1 T1 FLOOR TILE MFG: (FIELD FLOOR IN RESTROOMS) SIZE: TBD COLOR: TBD CONTACT: TBD MFG: TBD TYPE: TBD COLOR: TBD TB1 MFG: TBD COLOR: TBD (COUNTERTOP SURFACES AS NOTED) QTZ2 PL2 MFG: TBD COLOR: TBD (CABINETRY SURFACES AS NOTED) 1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE A THREE-COAT SYSTEM, PRIMER COAT AND TWO (2) FINISH COATS. 2. THE FINISHES AT TIME OF THE ISSUE DATE HAVE BEEN CHECKED AND ARE AVAILABLE UNLESS OTHERWISE NOTED. WALLCOVERING, CARPET, CERAMIC TILE AND SPECIALTY ITEMS CAN BE UP TO 6-8WEEK LEAD TIME. PARALLEL DESIGN GROUP STRONGLY RECOMMENDS ORDERING FINISHES IMMEDIATELY TO ENSURE TIMELY DELIVERY FOR AN ON- TIME INSTALATION. 3. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 4. ALL FINISHES AND SPECIFICATIONS ARE TO BE SUBMITTED TO PARALLEL DESIGN GROUP FOR FINAL APPROVAL PRIOR TO ORDERING FINISH MATERIALS. 5. ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. 6. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER PLANS. 7. ALL FINISHES TO COMPLY WITH APPLICABLE CODES. 8. PT1 AND VB1 TO BE USED THROUGHOUT UNLESS OTHERWISE NOTED. 9. REPRESENTS DIRECTION OF FLOORING 10. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER FLOORS FOR. GENERAL NOTES FINISH PLAN TAG ROOM NAME ROOM NUMBER FLOOR BASE WALL KEY NOTES 3/16" = 1'-0" SECOND FLOOR FINISH PLAN 1 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA401 SECOND FLOOR FINISH PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460321 NEW CARPET ON STAIRS. 2 PAINT EXISTING HANDRAIL.MARK DATE DESCRIPTION09/16/20 1. ALL AREAS RECEIVING PAINT ARE TO RECEIVE A THREE-COAT SYSTEM, PRIMER COAT AND TWO (2) FINISH COATS. 2. THE FINISHES AT TIME OF THE ISSUE DATE HAVE BEEN CHECKED AND ARE AVAILABLE UNLESS OTHERWISE NOTED. WALLCOVERING, CARPET, CERAMIC TILE AND SPECIALTY ITEMS CAN BE UP TO 6-8WEEK LEAD TIME. PARALLEL DESIGN GROUP STRONGLY RECOMMENDS ORDERING FINISHES IMMEDIATELY TO ENSURE TIMELY DELIVERY FOR AN ON- TIME INSTALATION. 3. WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 4. ALL FINISHES AND SPECIFICATIONS ARE TO BE SUBMITTED TO PARALLEL DESIGN GROUP FOR FINAL APPROVAL PRIOR TO ORDERING FINISH MATERIALS. 5. ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. 6. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER PLANS. 7. ALL FINISHES TO COMPLY WITH APPLICABLE CODES. 8. PT1 AND VB1 TO BE USED THROUGHOUT UNLESS OTHERWISE NOTED. 9. REPRESENTS DIRECTION OF FLOORING 10. FINISH SPECIFICATIONS CORRESPOND WITH THE FINISH PLAN ON THIS SHEET ONLY. DO NOT CROSS REFERENCE OTHER FLOORS FOR. GENERAL NOTES FINISH PLAN TAG ROOM NAME ROOM NUMBER FLOOR BASE WALL KEY NOTES MFG: TBD TYPE: CARPET TILE PATTERN: TBD COLOR: TBD INSTALLATION: TBD CONTACT: TBD FINISH SPECIFICATIONS CPT1 CPT2 CARPET LVT1 MFG: TBD SIZE: TBD PATTERN: TBD COLOR: TBD MFG: TBD SIZE: TBD COLOR: TBD GROUT: TEC POWER GROUT-COLOR TBD (WALLS ONLY) CONTACT: TBD WT2 LUXURY VINYL TILE MFG: TEC COLOR: TBD TYPE: POWER GROUT LOCATION: USED WITH PTX GROUT GT1 MFG: JOHNSONITE TYPE: 4" MILLWORK BASE -REVEAL PROFILE COLOR: TBD WALL BASE VB1 MFG: SHERWIN WILLIAMS COLOR: SW 7005 PURE WHITE FINISH: EGGSHELL PAINT PT1 PT2 PT3 MFG: TBD COLOR: TBD (CABINETRY SURFACES AS NOTED) PLASTIC LAMINATE + SOLID SURFACES PL1 MFG: TBD COLOR: TBD (COUNTERTOP SURFACES AS NOTED) QTZ1 MFG: TBD TYPE: CARPET TILE PATTERN: TBD COLOR: TBD INSTALLATION: TBD CONTACT: TBD MFG: SHERWIN WILLIAMS COLOR: SW 7069 IRON ORE FINISH: EGGSHELL MFG: SHERWIN WILLIAMS COLOR: TBD FINISH: EGGSHELL CERAMIC / GLASS WALL TILE MFG: (FIELD TILE IN RESTROOMS) SIZE: TBD COLOR: TBD GROUT: TEC POWER GROUT-COLOR TBD (WALLS ONLY) CONTACT: TBD WT1 T1 FLOOR TILE MFG: (FIELD FLOOR IN RESTROOMS) SIZE: TBD COLOR: TBD CONTACT: TBD MFG: TBD TYPE: TBD COLOR: TBD TB1 MFG: TBD COLOR: TBD (COUNTERTOP SURFACES AS NOTED) QTZ2 PL2 MFG: TBD COLOR: TBD (CABINETRY SURFACES AS NOTED) MARKETING STORAGE 301 ETR ETR ETR CONFERENCE 300 LVT PT1 VB1 HVAC 302 ETR ETR ETR 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA402 THIRD FLOOR FINISH PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0" THIRD FLOOR FINISH PLAN 1 1 NEW CARPET ON STAIRS. 2 PAINT EXISTING HANDRAIL.1 2 MARK DATE DESCRIPTION09/16/20 MILL/CASEWORK NOTES 1. CAULK SELECTIONS ARE TO BE PROVIDED TO PARALLEL DESIGN GROUP FOR SELECTION AND/OR APPROVAL BEFORE INSTALLATION OF MILLWORK. 2. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO PARALLEL DESIGN GROUP FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 3. CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 4. UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 5. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND PARALLEL DESIGN GROUP PRIOR TO FABRICATION. 6. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO PARALLEL DESIGN GROUP THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 7. UNLESS OTHERWISE SHOWN, PROVIDE 25" DEEP, PLASTIC LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. 8. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED STANDARD MOUNTING HEIGHTS FOR THE PARTICULAR APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT CHOICES TO PARALLEL DESIGN GROUPS FOR FINAL DECISIONS. 9. PROVED CABINETRY HARDWARE: MFG: RICHELIEU PRODUCT: CONTEMPORARY METAL PULL SIZE: 3 IN CENTER TO CENTER FINISH: BRUSHED NICKEL 3/A5002/A5004/A500 3' - 6"1' - 4" 8' - 8 3/4" 4' - 2 1/4" 1' - 2" 8' - 6 1/8" 4' - 2 7/8"2' - 6"3' - 6"2' - 0" 8' - 11 7/8" 1' - 3" COPIER BY TENANT WT22' - 6"1' - 6" 3' - 0" 2' - 6" 3/4" HOLD 5' - 5" 1' - 3" 1' - 3" 3/4"3" 2' - 0" 2' - 0" 3" WT2 3" 2' - 0" 2' - 3"1' - 8" 2' - 6"U.C. REFRIGERATOR BY TENANT 2' - 10" REF./FREEZER BY TENANT WT2 D / W BY TENANT WT2 10' - 2 3/4"3' - 0" 2 3/4"1' - 6" HOLD 2' - 0"3' - 0"1' - 6" 2' - 0" HOLD 3' - 6"1' - 6"3' - 0"2' - 0" 1' - 9" 3" 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA500 INTERIOR ELEVATIONSPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/8" = 1'-0" RECEPTION 200 - ENLARGED PLAN11/2" = 1'-0" RECEPTION 200 - FRONT VIEW 21/2" = 1'-0" RECEPTION 200 - BACK VIEW 3 1/2" = 1'-0" COPY 22751/2" = 1'-0" COFFEE 22561/2" = 1'-0" LARGE CONFERENCE 300 7 4" VINYL BASE (VB1) 24"D PLASTIC LAMINATE BASE CABINETS (PL1) 25"D QUARTZ COUNTERTOP (QTZ1) UNDERCABINET LIGHTING, CONCEAL WITH FASCIA (PL2). FASCIA TO ALIGN WITH BOTTOM SHELF 12"D PLASTIC LAMINATE UPPER CABINETS (PL2) PLASTIC LAMINATE FILLER PANEL (PL1) PLASTIC LAMINATE FILLER PANEL (PL2) 4" VINYL BASE (VB1) 24"D PLASTIC LAMINATE BASE CABINETS (PL1) 25"D QUARTZ COUNTERTOP (QTZ1) UNDERCABINET LIGHTING, CONCEAL WITH FASCIA (PL2). FASCIA TO ALIGN WITH BOTTOM SHELF 12"D PLASTIC LAMINATE UPPER CABINETS (PL2) PLASTIC LAMINATE FILLER PANEL (PL1) PLASTIC LAMINATE FILLER PANEL (PL2) 4" VINYL BASE (VB1) 24"D PLASTIC LAMINATE BASE CABINETS (PL1) 25"D QUARTZ COUNTERTOP (QTZ1) PLASTIC LAMINATE FILLER PANEL (PL1) 24"D PLASTIC LAMINATE PULL -OUT DOUBLE TRASH BINS (PL1) SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. SEE SHEET A101 FOR SPEC. SINGLE BOWL STAINLESS STEEL UNDERMOUNT BAR SINK AND FAUCET. SEE SHEET A101 FOR SPEC. 1/2" = 1'-0" RECEPTION 200 - STORAGE 4 4" VINYL BASE (VB1) 24"D PLASTIC LAMINATE BASE CABINETS (PL1) 25"D QUARTZ COUNTERTOP (QTZ2) PLASTIC LAMINATE FILLER PANEL (PL1) 4" VINYL BASE (VB1) 24"D LOCKABLE PLASTIC LAMINATE BASE CABINETS (PL1) 12"D QUARTZ TRANSACTION TOP (QTZ2) 25"D QUARTZ WORK SURFACE TOP (QTZ2) REMOVABLE MELAMINE PAINTED KNEE WALL (PT1) 4" VINYL BASE (VB1) 12"D QUARTZ TRANSACTION TOP (QTZ2) PAINTED KNEE WALL (PT1) UNDERCABINET LIGHTING, CONCEAL WITH FASCIA (PL2). FASCIA TO ALIGN WITH BOTTOM SHELF 12"D PLASTIC LAMINATE UPPER CABINETS (PL2) PLASTIC LAMINATE FILLER PANEL (PL2)MARK DATE DESCRIPTION09/16/20