HomeMy WebLinkAboutA002_SafetyPlanSCOPE OF WORK:
OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE.
OCCUPANCY CLASSIFICATION:
B (BUSINESS)
CHANGE OF OCCUPANCY CLASS:
NO
TOTAL BUILDING AREA:
10,686 GROSS SF
TOTAL AREA ON FLOOR:
SECOND FLOOR: 4,920 SQ.FT.
THIRD FLOOR: 846 SQ.FT.
TOTAL PROJECT AREA:
5,766 SQ.FT.
OCCUPANCY CALCULATIONS
SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
GENERAL OFFICE 3,552 100 35.5
CONFERENCE 1,081 15 72
STORAGE 202 300 .7
TOTAL OCCUPANTS IN PROJECT AREA:108.2
NUMBER OF REQUIRED EXITS:
2
MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 300'
SPRINKLER SYSTEM (YES/NO):
YES-EXISTING TO REMAIN
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
N/A
APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD,
ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH
INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND
ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.ELEX
EXIT ACCESS TRAVEL = 46'
63 SF
MARKETING STORAGE
301
643 SF
CONFERENCE
300
20 SF
HVAC
302
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT -BUILDING EXIT LOCATION
FIRE EXTINGUISHER
EXIT SIGNAGE
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING,
REFRENCE A200 FOR LOCATION.
LEGEND
EX
FE
EL
NL
EP
AREA NOT IN CONTRACT
AREA OF WORK
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA002
THIRD FLOOR LIFE
SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
THIRD FLOOR PLAN LIFE SAFETY 1 MARK DATE DESCRIPTION09/16/20