HomeMy WebLinkAboutA201_ReflectedCeilingD D D D DDDD D D
DD
DDDDD D DD D3D3
D3 1. WHERE CEILINGS ARE TEXTURED, ADD NEW LAYER OF SMOOTH 5/8" DRYWALL
CEILINGS THROUGHOUT AT 9' -10" +/-A.F.F.
2. REMOVE ALL LIGHT FIXTURES AND PROVIDE 4" SQUARE RECESSED CAN LIGHTING
THROUGHOUT. COLOR TEMPERATURE TO BE 3500K.
3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
COVERPLATE.
4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND
IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY
POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO
BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-OUT AND TOTAL
WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE
FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED
WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET.
6. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY
SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY
WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED
SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED.
PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS
REQUIRED.
7. ALL DEVICES AND COVERS TO BE WHITE.
8. ALL DRYWALL CEILINGS TO BE PAINTED PT1 UNLESS NOTED OTHERWISE.
GENERAL NOTESLEGEND
KEYED NOTES
X
X' -X"
CEILING TYPE
CEILING HEIGHT
GYPSUM BOARD CEILING
PAINTED WHITE UNLESS NOTED OTHERWISE ON FINISH PLAN; PROVIDE ALL ACCESS
PANELS REQUIRED FOR MAINTENANCE -LOCATIONS SHALL BE APPROVED BY
PARALLEL DESIGN GROUP; PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL
BULKHEAD CONDITIONS. SEE SECTIONS FOR VERTICAL RETURN DIMENSIONS.
A
INDICATES NIGHT LIGHT
LOCATIONNL
EXIT LIGHT FIXTURE
EMERGENCY LIGHT
FIXTURE
NEW GYPSUM BOARD CEILING
LIGHT SWITCH
LIGHT SWITCH,
3-WAY
LIGHT SWITCH,
4-WAY
LIGHT SWITCH,
DIMMER
LIGHT CIRCUIT
3
4
D
4" SQUARE RECESSED CAN LIGHT
MFG: HALO
MODEL: PRS4 SMF48FS
COLOR: WHITE 3500K
EL
EXISTING GYPSUM BOARD
CEILING
PENDANT FIXTURE, 24" DIAMETER
($700 MATERIAL
ALLOWANCE/FIXTURE)
LED UNDER CABINET LIGHTING
MFG: HALO
MODEL: HU11
C1
P1
L1
LED WALL SCONCES1
PENDANT FIXTURE, 6" -8" DIAMETER
($450 MATERIAL
ALLOWANCE/FIXTURE)
P2
C1 C1
C1C1
C1 C1
C1 C1 C1 C1
C1
C1
C1
C1 C1 C1 C1 C1 C1
C1
C1
C1
C1
C1 C1
C1
C1
C1 C1
4' - 0"
4' - 0"
5' - 0" 5' - 0"5' - 0"
C1 C1
C1C1
5' - 0"5' - 0"C1 C1
C1 C1 3' - 6" 3' - 6" C1 C1
5' - 0"
C1C1
C1C1 3' - 6" 3' - 6" C1C1
C1C1
C1C1
C1 C1
5' - 0"3' - 6" 3' - 6" 3' - 0"3' - 6"5' - 6"7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
C1 C1
C1 C1
5' - 0" 5' - 0"C1 C1
C1 C1
5' - 0" 5' - 0"C1C1
C1C1
5' - 0"5' - 0"C1
C1
C1
C1C1
C1C1
3' - 0"
3' - 0"5' - 0" 5' - 0"5' - 6" L1
P1
L1
P1
P1
C1
C1
C1
C1
C1
C1
5' - 0"3' - 6"3' - 6"C1
C15' - 0"C1
C1C1
C1
5' - 0"5' - 0"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C15' - 0"5' - 0"5' - 0" 5' - 0"5' - 0"5' - 0" 5' - 0" 5' - 0"5' - 0" 5' - 0"3' - 0"
C1
5' - 0"
C1
C1
C1
C1
C1
7' - 6"5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0"C1
C1
C1
C1
C15' - 0" 5' - 0" 5' - 0" 5' - 0"GYP
9' -6"
GYP
9' -10"
GYP
9' -10"
GYP
9' -10"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 C1
C1
C1
C1
C1
C1
C15' - 0" 5' - 0"4' - 0"5' - 0" 5' - 0" 5' - 0"4' - 0"5' - 6" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 4' - 1 1/2"
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
C1 5' - 0" 5' - 0"7' - 0" 7' - 0" 7' - 0" 7' - 0"2
1
1
1
2
2 ELEL
ELELNL
NL
NL
NL
NL
S1S1
5' - 0" 5' - 0"
P2
P2
P2
P2
AREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16907.30.2020BWSB & BDA201
SECOND FLOOR
REFLECTED
CEILING PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST -2ND & 3RD FLOORCARMEL, INDIANA 460321 CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF
2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1.
2 CENTER PENDANTS OVER ISLAND. REFER TO FLOOR PLAN AND
CONFIRM FINAL LOCATION WITH TENANT.
3/16" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN1 MARK DATE DESCRIPTION09/16/20