HomeMy WebLinkAboutRev_A001_SafetyPlanSCOPE OF WORK: OFFICE SPACE BUILD-OUT REMODEL TO PREVIOUSLY BUILT-OUT OFFICE. OCCUPANCY CLASSIFICATION: B (BUSINESS) CHANGE OF OCCUPANCY CLASS: NO TOTAL BUILDING AREA: 10,686 GROSS SF TOTAL AREA ON FLOOR: SECOND FLOOR: 4,920 SQ.FT. THIRD FLOOR: 846 SQ.FT. TOTAL PROJECT AREA: 5,766 SQ.FT. OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GENERAL OFFICE 3,552 100 35.5 CONFERENCE 1,081 15 72 STORAGE 202 300 .7 TOTAL OCCUPANTS IN PROJECT AREA:108.2 NUMBER OF REQUIRED EXITS: 2 MAXIMUM EXIT ACCESS TRAVEL DISTANCE: 200' SPRINKLER SYSTEM (YES/NO): NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2008 INDIANA BUILDING (2006 IBC, ASCE-7-2005) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. CODE SUMMARY GENERAL NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE PROTECTION SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO SHEET A100 FOR WALL TYPE AND CONSTRUCTION DETAILS 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT -BUILDING EXIT LOCATION FIRE EXTINGUISHER EXIT SIGNAGE EMERGENCY LIGHTING NIGHT LIGHT/EMERGENCY LIGHTING, REFRENCE A200 FOR LOCATION. LEGEND EX FE EL NL EP AREA NOT IN CONTRACT AREA OF WORK COMMON PATH OF EGRESS EXIT ACCESS TRAVEL DISTANCE EX ELOFFICE 205 131 SF SMALL CONFERENCE 206 131 SF SMALL CONFERENCE 207 OFFICE 208 TODD'S OFFICE 209 OPEN OFFICE 210 OFFICE 213 OFFICE 212 OFFICE 211 COPY 227 9 SF HVAC 226 13 SF ACCT. STRG. 224 13 SF STRG. 223 29 SF OFFICE STORAGE 202 GUEST R.R. 201 GUEST R.R. 204 JAN. 203 RECEPTION 200 SEMI-PRIVATE OFFICE 214 49 SF SERVER 215 OSM 216 OSM 217 35 SF STUDIO STORAGE 218 87 SF MEETING 221 89 SF MEETING 220 JENNIFER'S OFFICE 219 DESIGN STUDIO 222 FEFE FE EX EL ELELELCOMMON PATH OF EGRESS = 8' EXIT ACCESS TRAVEL = 60' COFFEE 225 EXIT ACCESS TRAVEL = 117' COMMON PATH OF EGRESS = 24'EXIT ACCESS TRAVEL = 45'EXIT ACCESS TRAVEL = 51'EXIT ACCESS TRAVEL = 44'1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16909.02.2020BWSB & BDA001 SECOND FLOOR LIFE SAFETY PLANPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0" SECOND FLOOR LIFE SAFETY PLAN 1 MARK DATE DESCRIPTION09/16/20