HomeMy WebLinkAboutRev_A301_PowerDataUP
DED +44 +44GFI+44DEDGFI
+44
GFI
+44
+60+60+60HD+60+60+60HD+60+60+60HDEXEX EX EXEX EX EXEX EX
EXEX EX EXEX EX
EXEX
EX EXEX EXEXGFI+44+44
+44+44 +44 +441. ALL OUTLETS, COVERS, SWITCHES, AND SWITCHPLATE COVERS TO
BE WHITE.
2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE
TEMINAL AT FACE PLATE.
3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI.
4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E.
MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN
SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL
ROOM.
5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSWISE.
6. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC
STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT
SPECIFIED BY PARALLEL DESIGN GROUP.
GENERAL NOTES
LEGEND
POWER OUTLET, DUPLEX
POWER OUTLET, QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED JUNCTION BOX
DATA/COMMUNICATION OUTLET (PROVIDE
BOX AND PULL STRING ONLY)
BOX, BLANK COVER PLATE
BOX, OPEN
P POWER AND DATA POLE
FLOOR BOX WITH JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER AND DATA,
FLUSH MOUNTED
NEW
EXISTING TO REMAIN
DEDICATED CIRCUIT
GROUND FAULT CIRCUIT INTERRUPT OUTLET
HEIGHT OF ELECTRICAL OR DATA DEVICE
N
EX
DED
GFI
+44"
J
B
O
J
DATA
JB
HD
CEILING MOUNTED POWER & HDMIHD
HD FLOOR BOX WITH POWER, DATA, & HDMI
FLUSH MOUNTED
SPECIAL PLUG
HDMI
KEY NOTES
RANGE PLUGR
OPEN OFFICE
210
TODD'S OFFICE
209
OFFICE
208
SMALL CONFERENCE
207
SMALL CONFERENCE
206OFFICE
205
COPY
227
HVAC
226
ACCT. STRG.
224
SEMI-PRIVATE OFFICE
214
SERVER
215 OSM
216
OSM
217
STUDIO STORAGE
218
MEETING
221
MEETING
220
JENNIFER'S OFFICE
219
DESIGN STUDIO
222
GUEST R.R.
201
OFFICE STORAGE
202
STRG.
223
JAN.
203
GUEST R.R.
204
RECEPTION
200
OFFICE
211
OFFICE
212
OFFICE
213
1
2
3
3
3
5 5
5
5
4
6
5
5
AREA NOT IN CONTRACT
AREA OF WORK 1[PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399 2020.16909.02.2020BWSB & BDA301
SECOND FLOOR
POWER AND DATAPYATT BUILDERS630 3RD AVENUE SOUTHWEST - 2ND & 3RD FLOORCARMEL, INDIANA 460323/16" = 1'-0"
SECOND FLOOR POWER & DATA 1
1 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
2 CONFIRM IT REQUIREMENTS WITH TENANT.
3 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION
SUPPLIED BY TENANT, CONTRACTOR INSTALLED. COORDINATE
EXACT LOCATION WITH TENANT.
4 PROVIDE POWER AS NEEDED FOR GARBAGE DISPOSAL.
5 PROVIDE FLUSH MOUNT 4" CORE DRILL FOR POWER AND DATA.
COORDINATE EXACT LOCATION WITH TENANT.
6 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED
UNDERCOUNTER FRIDGE.MARK DATE DESCRIPTION09/16/20