Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1-1A
S ES ESE RSV HP OFFICE 05.295 CONFERENCE 05.340 CONFERENCE 05.110 OFFICE 05.270 TRAINING 05.225 FA OFFICE 05.285 FA OFFICE 05.280 FA OFFICE 05.275 CONFERENCE 05.445 STORAGE 05.440 OFFICE 05.430 OFFICE 05.470 OFFICE 05.475 OPEN OFFICE 05.460 OPEN OFFICE 05.480 FA OFFICE 05.490 FA OFFICE 05.495 OFFICE 05.315 OPEN OFFICE 05.520 PRINT ROOM 05.530 RECEPTION 05.105 CASHIER 05.545 OFFICE 05.535 OFFICE 05.115 OFFICE 05.325 OPEN OFFICE 05.485 BREAKROOM 05.505 MEN RESTROOM 05.500 CONFERENCE 05.350 OFFICE 05.330 OFFICE 05.320 OFFICE 05.310 OFFICE 05.305 OFFICE 05.300 OFFICE 05.265 OFFICE 05.260 OFFICE 05.255 OFFICE 05.250 OFFICE 05.245 OFFICE 05.240 OFFICE 05.235 OFFICE 05.230 OFFICE 05.335 WOMEN RESTROOM 05.510 PRINT AREA 05.515 PANTRY 05.450 ELEVATOR LOBBY 05.100 STAIRS 05.000 STAIRS 05.005 OFFICE 05.425 CORRIDOR 05.465 OPEN OFFICE 05.540 WELLNESS 05.43505.30005.425 05.23005.430 05.24005.470 05.47505.490 05.49505.23505.25005.26005.24505.25505.26505.27005.280 05.285 05.275 05.295 05.32505.31505.11505.33505.33005.32005.30505.31005.460A 05.44505.460B05.450B05.545A05.535A05.480B05.480A 05.520B05.520A 05.535B05.530 05.545B 05.43505.00005.46505.005FECFECAED 01/A1-1A01/A1-1B01/A1-1A01/A1-1BSK1 FAU1 SPD1 CO1 IWD1 WB WB WB WB A7-113 A7-1 26A7-1 5A7-1A7-1 4 8A7-1SIMA7-1811 A7-1 ±5'-63 4"±7'-514" EQEQ1'-6" MIN A7-1 9 A7-1 9 OPP 10A7-1A7-113A7-1 12 EQ EQ 100 101 101 RSV AEDFEC FEC FECFECAED Plot Date: 8/25/2020 12:03:36 PM Filename: \\nelson.com\corpdata\Proj\bank Of America\IN\20.0000681.000-bofa Indianapolis Mlwm 5th Floor Refresh\DRAWINGS\A-I\3_CD\INW-044 BofA Indianapolis MLWM 5th Floor Refresh A1-1A & A1-1B.dwg User: Edgardo Rivera-Ortiz Device: _AutoCAD PDF (General Documentation).pc3 PenTable: _NELSON-HALF.ctbA1-1A CONSTRUCTION PLAN - SIDE A Proj. No: Drawn By: Project Manager: ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, LLC 2020 ALL RIGHTS RESERVED Designer: Reviewed By: Approved By: Key Plan: Nelco Architecture, Inc. a licensed affiliate 4' 0 8' 16' Scale: PROJECT LOCATION Phone: 30 West Monroe Street - Suite 200 Chicago, IL 60603-2409 (312) 263-6605 (312) 276-4340 Phone: 20.0000681.000 MJL ERO ERO/MBM MJL/VPD VPD Date:No: Description: By: Client: Sheet Title: Consultant: Project Title & Address: Seal: Sheet Number: INW-044 BofA Indianapolis MLWM 5th Floor Refresh 510 96th Street Indianapolis, IN 46240 OWNER'S PROJECT MANAGER Jones Lang LaSalle Leslie Soto 540 W. Madison St, Suit eIL4-540-04-55 Chicago, IL 60661 T: 312.909.2139 E: leslie.soto@am.jll.com MEP ENGINEER Integrated Engineering Consultants, Inc. (IEC) Tim Vining 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T: 216.901.6711 E: tim.vining@iec-inc.cc GENERAL CONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.977.9255 E: tlc@midamericacontracting.com ISSUE FOR EARLY DEMOLITION 1 ERO 07.24.2020 ISSUE FOR ENGINEERING 2 ERO 07.31.2020 ISSUE FOR LONG LEAD ITEMS 3 ERO 07.31.2020 ISSUE FOR PERMIT 4 ERO 08.25.2020 CONSTRUCTION PLAN LEGEND: CONSTRUCTION PLAN GENERAL NOTES 1. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 2. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN PROPER ALIGNMENT, U.N.O. 3. ALL DIMENSIONS ARE TO FINISH CONSTRUCTION, U.N.O. DIMENSIONS NOTED "HOLD” MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN ± 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. DIMENSIONS NOTED “CLEAR” ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WITHOUT EXCEPTION. DIMENSIONS MARKED ± MEAN A VARIANCE NOT GREATER THAN 1 INCH, VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE FINISH FACE OF WALL BELOW SILL, U.N.O. 4. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT SURFACES. 5. PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING SLABS, WALLS AND SHAFTS, SEAL ABANDONDED PENETRATIONS AT FLOORS, WALLS AND SHAFTS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS. PATCH FIREPROOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED STRUCTURAL STEEL. 6. ALL GLASS SHALL BE CLEAR TEMPERED. GLAZING TONG MARKS SHALL NOT BE VISIBLE. CLEAN & POLISH ALL GLASS PRIOR TO PROJECT DELIVERY. 7. REFER TO THE PARTITION TYPES FOR PARTITION THICKNESS. 8. ALL INFILL OF DOORS/WALLS/OPENINGS SHALL MATCH AND BE FLUSH WITH EXISTING ADJACENT PARTITION CONSTRUCTION. 9. ALL PARTITIONS ABUTTING COLUMNS ARE TO ALIGN WITH THE FACE OF THE COLUMN, U.N.O. 10. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION. 11. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O. 12. REFER TO MATERIAL SCHEDULE & FINISH PLAN FOR MATERIALS & LOCATIONS THAT REQUIRE A LEVEL 5 FINISH, U.N.O. 13. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. 14. CONTRACTOR SHALL COORDINATE REVIEW OF THE PARTITION LAYOUT WITH THE ARCHITECT PRIOR TO PARTITION INSTALLATION. 15. CONSTRUCTION OF FIRE-RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, SHALL BE IN ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED. 16. ACOUSTICAL (SOUND-ISOLATION) PARTITIONS SHALL BE SEALED FOR FULL HEIGHT TO PREVENT PASSAGE OF AIRBORNE SOUND. TAPE AND FINISH ALL GYPSUM WALLBOARD JOINTS AND FASTENERS (INCLUDING ABOVE SUSPENDED CEILING). CAULK AT PERIMETER AND SEAL AT ALL PENETRATIONS. 17. WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, SECURE THE TOP TRACK TO THE EXPOSED CEILING GRID. PROVIDE A COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE CEILING GRID. PROVIDE TAPABLE METAL J-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6'-0" AND NO JOINTS GREATER THAN 3/16", U.N.O. CAULK PERIMETER AT TOP OF GWB. 18. PROVIDE GROUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR SUPPORT OF CASEWORK, SHELF-STANDARDS, A/V DEVICES, FURNITURE, ETC. ALL CONCEALED LUMBER AND BLOCKING TO BE FIRE TREATED. COORDINATE BLOCKING REQUIREMENTS WITH FURNITURE & AV INSTALLERS. WHERE BLOCKING OR ADDITIONAL STUDS ARE REQUIRED AT EXISTING PARTITIONS, THEY ARE TO BE PATCHED AND REPAIRED. SEE CONSTRUCTION PLANS FOR WALL-MOUNTED MARKERBOARD, MONITORS & PROJECTION SCREENS; PROVIDE BLOCKING PER MANUFACTURERS' REQUIREMENTS. 19. PROVIDE VERTICAL CONTROL JOINTS 30' O.C. MAX. IN ALL GWB PARTITIONS LONGER THAN 30'. WHEN POSSIBLE CONTROL JOINTS SHOULD BE LOCATED ABOVE THE CORNER OF A DOOR. 20. ALL HINGED DOORS TO BE 4" FROM NEAREST PERPENDICULAR PARTITION, U.N.O. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. ALL DOORS SHALL HAVE 1'-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND 1'-0 CLEAR ON THE STRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A CLOSER) VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 21. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO BE USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS OF THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR SLAB OR FINISHED FLOOR THICKNESS. 22. PROVIDE DOUBLE STUDS AT DOOR JAMBS. INSTALL ADDITIONAL STUDS IN EXISTING PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO PROVIDE DOUBLE STUDS AT JAMBS. 23. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAGE (MINIMUM) @ 16" O.C. (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE LOCATIONS. 24. PROVIDE DIAGONAL STUD BRACING TO SLAB ABOVE @ 48" O.C. AT DROP ARCHES/BULKHEADS. 25. GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING ROUGH-IN (E.G.BATHROOMS, PANTRY, JANITOR'S CLOSET, WET COLUMNS) SHALL BE WATER-RESISTANT. GENERAL CONTRACTOR (GC) RESPONSIBILITIES PER DIRECTION FROM JLL, ALTHOUGH THE GC IS NOT RESPONSIBLE FOR PROCURING THE PRODUCTS BELOW, THE GC IS RESPONSIBLE FOR ASSISTING WITH SCHEDULING AND MANAGING THESE BAC VENDORS · TYCO SECURITY · TECHNOLOGY (TBOD) · CABLING VENDOR · AV · BRANDING · ART · KNOLL & OTHER FURNITURE - CORPORATE CONCEPTS · CARPET, RESILIENT FLOOR & RESILIENT BASE - TANDUS PER DIRECTION FROM JLL, THE GC IS RESPONSIBLE FOR PROCURING PRODUCTS FROM AND SCHEDULING & MANAGING THESE BAC VENDORS: · DEMOUNTABLE OFFICE FRONT DEALER NOT IN CONTRACT EXISTING PARTITION TO REMAIN NEW CONSTRUCTION ROOM TAG CENTERLINE EXISTING DOOR TO REMAIN NEW DOOR FIRE RETARDANT WALL BLOCKING PARTITION TYPE CL WB -- 1/8" = 1'-0" CONSTRUCTION PLAN - SIDE A1 A1-1A SIDE A ROOM NAME ROOM# KEYNOTES: 100. NEW SEMI-RECESSED AED CABINET; EXISTING AED EQUIPMENT TO BE RELOCATED HERE; REFER TO AN-5 FOR FURTHER INFO. 101. NEW SEMI-RECESSED FEC CABINET; EXISTING EXTINGUISHER EQUIPMENT TO BE RELOCATED HERE; REFER TO AN-5 FOR FURTHER INFO. -- 09/16/20