Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AN-3.2
Plot Date: 8/25/2020 12:01:37 PM Filename: \\nelson.com\corpdata\Proj\bank Of America\IN\20.0000681.000-bofa Indianapolis Mlwm 5th Floor Refresh\DRAWINGS\A-I\3_CD\INW-044 BofA Indianapolis MLWM 5th Floor Refresh AN-3.2.dwg User: Edgardo Rivera-Ortiz Device: _AutoCAD PDF (General Documentation).pc3 PenTable: _NELSON-HALF.ctbAN-3.2 ACCESSIBILITY DIAGRAMS Proj. No: Drawn By: Project Manager: ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, LLC 2020 ALL RIGHTS RESERVED Designer: Reviewed By: Approved By: Nelco Architecture, Inc. a licensed affiliate Phone: 30 West Monroe Street - Suite 200 Chicago, IL 60603-2409 (312) 263-6605 (312) 276-4340 Phone: 20.0000681.000 MJL ERO ERO/MBM MJL/VPD VPD Date:No: Description: By: Client: Sheet Title: Consultant: Project Title & Address: Seal: Sheet Number: INW-044 BofA Indianapolis MLWM 5th Floor Refresh 510 96th Street Indianapolis, IN 46240 OWNER'S PROJECT MANAGER Jones Lang LaSalle Leslie Soto 540 W. Madison St, Suit eIL4-540-04-55 Chicago, IL 60661 T: 312.909.2139 E: leslie.soto@am.jll.com MEP ENGINEER Integrated Engineering Consultants, Inc. (IEC) Tim Vining 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T: 216.901.6711 E: tim.vining@iec-inc.cc GENERAL CONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.977.9255 E: tlc@midamericacontracting.com ISSUE FOR EARLY DEMOLITION 1 ERO 07.24.2020 ISSUE FOR ENGINEERING 2 ERO 07.31.2020 ISSUE FOR LONG LEAD ITEMS 3 ERO 07.31.2020 ISSUE FOR PERMIT 4 ERO 08.25.2020 1. FLOOR SURFACES SHALL BE SLIP RESISTANT. 2. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE NOT LESS THAN 44" IN WIDTH. 3. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2. 4. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 34" AND 44" ABOVE FLOOR FINISH. 5. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 34" AND 44" ABOVE THE FLOOR. 6. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. 7. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. 8. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3' IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WITH OF THE DOORWAY IS NOT LESS THAN 32". 9. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ON STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 10. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 11. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY, CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 12. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" A.F.F. TO BOTTOM OF BOX. 13. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A BUILDING SHALL BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED. 14. ENTRY TO SANITARY FACILITIES: A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE. B. DOORWAYS TO HAVE A 32" CLEAR OPENING. C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH. 15. TOILET ROOM ACCESSORIES: A. MOUNT BOTTOM EDGE OF MIRRORS NO HIGHER THAN 40" FROM THE FLOOR. B. MOUNT TOILET TISSUE DISPENSERS WITHIN 7"-9" TO CENTERLINE FROM THE FRONT EDGE OF THE TOILET SEAT. C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR. 16. SINGLE ACCOMMODATION TOILET FACILITY: A. MINIMUM CLEAR SPACE IN FRONT OF WATER CLOSET TO BE 48". B. NOT USED 17. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17" AND 19". 18. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF THE TOILET WITH THE GREATEST SEPARATION FROM ADJACENT WALL OR OTHER SURFACE. 19. PROVIDE GRAB BARS ON THE SIDE WALL AND BACK WALL OF WATER CLOSET. A. GRAB BARS TO BE 33" TO CENTER LINE OF GRAB BAR, ABOVE AND PARALLEL TO THE FLOOR. (MIN 33", MAX 36" TO TOP ALLOWED) B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT BACK TO BE 36" LONG. C. DIAMETER OF GRAB BARS TO BE 1 1/4" TO 1 1/2". D. PROVIDE 1 1/2" CLEARANCE BETWEEN GRAB BARS AND WALL. E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL SUPPORT A 250 POUND LOAD. F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. G. GRAB BARS AND ANY ADJACENT SURFACE SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". 20. PROVIDE A CLEAR FLOOR SPACE 30" X 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH. 21. MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT UP EXTENDING A MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH, AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY. 22. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER OPPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF CLOSING ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 23. INSULATE OR OTHERWISE COVER ALL WATER AND DRAIN PIPES UNDER SINKS TO PREVENT CONTACT. 24. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS. ACCESSIBILITY NOTES: INTERNATIONAL TTY SYMBOL INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS ELEVATOR/STAIR/DIRECTION SIGNS 6 SIGNAGE NOTES & LOCATION of Law 10"instructedE 10" unless otherwise In case of fire use stairs Smoking Penalty Under PLAN No b) DISPLAY CONDITIONS a) PROPORTIONS THIS DETAIL IS FOR GENERAL REFERENCE ONLY. COORDINATE EVACUATION SIGNAGE FINAL SIGNAGE WITH SIGNAGE VENDOR. NOTE : N.T.S. INTERNATIONAL SYMBOL OF ACCESSIBILITY INTERNATIONAL SYMBOLS2 N.T.S. GRAB BARS AT TOILET STALLS AND LAVATORY CLEARANCES ACCESSIBLE WOMEN'S ROOM SIGN MEN'S ROOM SIGN ACCESSIBLE WOMEN (BRAILLE) (BRAILLE) MEN TOILET SIGNAGE THIS DETAIL IS FOR GENERAL REFERENCE ONLY. COORDINATE FINAL SIGNAGE WITH SIGNAGE VENDOR. NOTE : (BRAILLE) MEN (BRAILLE)5/8" HIGH6" WOMEN MEN'S ROOM SIGNWOMEN'S ROOM SIGN N.T.S. N.T.S. 10 DRINKING FOUNTAINS & WATER COOLERS 1/2" RADIUS MAX. 1 1/4" MAX. 30 °MAX. RADIUS ANGLED RISER OF ACCEPTABLE NOSINGS USABLE TREAD WIDTH AND EXAMPLES ANGLED NOSING 4 ROUNDED NOSING MANEUVERING CLEARANCES 8 HANDRAIL EXTENSION REQUIRED TREAD WIDTH MIN. X NOTE: T EXTENTION AT BOTTOM OF RUN EXTENTION AT TOP OF RUN 11 STAIR HANDRAILS AT BOTTOM RISER THE CONDITIONS ILLUSTRATED ON THIS SHEET CONSTITUTE LEGAL STANDARDS FOR HANDICAPPED ACCESSIBILITY. THEY DO NOT CONSTITUTE ACTUAL ARCHITECTURAL CONDITIONS FOR CONSTRUCTION IN THE COURSE OF THIS WORK. SEE ENCLOSED ARCHITECTURAL DRAWINGS FOR ACTUAL EXTENT OF WORK. NOT ALL CONDITIONS SHOWN HERE NECESSARILY OCCUR IN THIS PROJECT. CONTRACTOR TO INFORM ARCHITECT WHEN DUE TO FIELD CONDITIONS, ETC., ACTUAL CONSTRUCTION WILL NOT CONFORM TO THESE STANDARDS. NOTE: AND SAMPLE RAMP DIMENSIONS COMPONENTS OF A SINGLE RAMP RUN3 LANDING SURFACE OF RAMP LEVEL OR RUN HORIZONTAL PROJECTION SLOPE 1:12 to < 1:16 1:16 to < 1:20 30" 30" MAXIMUM RISE MAXIMUM HORIZ. PROJECTION 30'-O" 40'-O"RISEN.T.S. 12 WHEELCHAIR AND ONE AMBULATORY PERSON MINIMUM PASSAGE WIDTH FOR ONE36" MIN.36"x>48" 36" 44" MIN 42" MIN X<48" 42" MIN48" MINTURNS AROUND AN OBSTRUCTION WIDTH OF ACCESSIBLE ROUTE FOR 78" MIN 60" MINSPACE NEEDED FOR SMOOTH U-TURN IN A WHEELCHAIR ACCESSIBLE ROUTES 7 3.5 NTSACCESSIBLE HEIGHTS MINIMUM MANEUVERING CLEARANCES AT DOORS13 22" MIN 42" MIN48" MIN48" MINX 18" MIN60" MINX Y 44" MIN22" MIN 48" MIN48" MIN PULL SIDE PUSH SIDE PULL SIDE NOTE: X = 36" MIN IF Y = 60" X = 42" MIN IF Y = 54" PUSH SIDE 42" MIN 24" MIN Y44" MINX 24" MIN X 24" MIN Y48" MINPULL SIDE PUSH SIDE 12" MAX.33"-36" TO TOP 42" MIN 54" MIN 36" MIN 33"REAR WALL OF STANDARD STALL 12"MIN 24"MIN 36"MIN 12" MAX42" MIN 17"-19"SIDE WALLS19" MIN.33"-36" TO TOP 17"-18" 7"-9"30"MIN17"MIN 48" MIN9" MIN6" MAX 17" 8" MIN 40"MAX27"MIN34"MAX(C)"x"PARALLEL APPROACH (B) 30" MIN FORWARD APPROACH 48" MIN (A)"x"CLEAR FLOOR SPACE 30" MIN NOTE: X < 24" (610 mm) 36" MIN CLEAR FLOOR SPACE IN ALCOVES 48" MIN48" MIN30" MIN30" MINNOTE: X < 15" (380 mm) 60" MIN 48" MIN "x" "x"CL LC 4'-0" MAX.MIN 34", MAX 44"F.E.C. 4'-0" MAX.1'-6" 4'-0" MAX. TO TOP OF OPERABLE PARTS PHONE LC 6'-8" FIRE ALARM, STROBE, SPEAKER (AS APPLICABLE) T'STAT, INTERCOM, 2ND ROW OF RECEPT. CENTER TO CLUSTER. (WHEN USING DIMMERS, LOCATE T'STAT AT OPPOSITE SIDE OF DOOR) SWITCHES, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. POWER & TELEPHONE RECEPTACLES FINISHED FLOOR LC U.O.N.LC 6" DOOR N.T.S. N.T.S. N.T.S. N.T.S. N.T.S. N.T.S. N.T.S. N.T.S.1/4" MAX.1/4" TO 1/2" MAX.CHANGE IN LEVEL CHANGE IN LEVEL 2" MAX ALLOWED PER 2013 CBC 505.7.1 1 1/2" MIN 34" - 38"12" MIN TREAD WIDTHT 2'-10"1 1/2" MINNOTE: IF "X" > 15" (380 mm), THEN AN ADDITIONAL MANEUVERING CLEARANCE OF 12" (305 mm) SHALL BE PROVIDED AS SHOWN NOTE: IF "X" > 24", THEN AN ADDITIONAL MANEUVERING CLEARANCE OF 6" SHALL BE PROVIDED FRONT APPROACH - SWINGING DOOR FRONT APPROACH - SWINGING DOOR FRONT APPROACH - SLIDING OR FOLDING DOORS SLIDE SIDE APPROACH - SLIDING OR FOLDING DOORSLATCH SIDE APPROACH - SWINGING DOOR LATCH SIDE APPROACH - SWINGING DOOR LATCH SIDE APPROACH - SLIDING OR FOLDING DOORS SIDE APPROACH - SWINGING DOOR NOTE: Y = 48" MIN IF DOOR HAS BOTH A CLOSER AND LATCH TWO HINGED DOORS IN SERIES TWO HINGED DOORS IN SERIES NOTE: X = 12" MIN IF DOOR HAS BOTH A CLOSER AND LATCH NOTE: Y = 54" MIN IF DOOR HAS A CLOSER NOTE: Y = 48" MIN IF DOOR HAS A CLOSER HINGE SIDE APPROACH - SWINGING DOOR 48" MIN 24" PREFERRED 1 5 9 30° MA X . 30° MA X. 60" MIN. LANDING LEVEL 60" MIN. TURNS AROUND AN OBSTRUCTION WIDTH OF ALT. ACCESSIBLE ROUTE FOR 5/8" HIGH6" 5/8" HIGH 6"5/8" HIGH 6"54" MIN 17"-19" 19" MIN.7"-9" X 48" MIN TWO HINGED DOORS IN SERIES 32" MIN. CLR. ACCESSIBLE DOORWAYSRECESSED DOOR - PULL SIDE RECESSED DOOR - PUSH SIDE W/ LATCH AND CLOSER RECESSED DOOR - PUSH SIDE W/O LATCH & CLOSERX>8"48" MIN X>8"48" MIN12" MIN.X>8" 60" MIN18" MIN.X>27"X>80" 4" MAX. 19" MAX.18" MIN. TO CL1 1/4" MAX.34" - 38"60" MIN FOR CORRIDORS OVER 200' 18" MIN.32" MIN.CLR.17" MIN.DEPTH 6" MAX.TOE CLEARANCE9" MIN.8" MIN.27" MIN.36" MAX.48" MIN. SPOUT HEIGHT AND KNEE CLEARANCE FORWARD APPROACH CLEAR FLOOR SPACE FORWARD APPROACH 5" MAX SPOUT HEIGHT FOR STANDING PERSONS SHALL BE 38" MIN. AND 43" MAX. ABOVE FINISHED FLOOR 18" TO 19"30" MIN18" MIN.VARIES 48" MIN. CLEAR FLOOR SPACE AT "HI-LOW" DRINKING FOUNTAIN ALCOVES30" MIN"HI" FOUNTAIN "LOW" FOUNTAIN AT "HI-LOW" TYPE FOUNTAINS, CENTER THE 30" BY 48" CLEAR FLOOR SPACE ON THE "LOW" FOUNTAIN FIXTURE AT ALCOVE > 24" DEEP, PROVIDE EXTRA 6" WIDTH4"4"4" (BRAILLE) 4" (BRAILLE) STAIR 6" (BRAILLE)6" A 5/8" HIGH 2" HIGH 2 3" (BRAILLE)3"3" HIGH NOTE : FINAL SIGNAGE WITH SIGNAGE VENDOR. THIS DETAIL IS FOR GENERAL REFERENCE ONLY. COORDINATE SIGNAGE NOTES: FINISHES: TBD PLAQUE: TBD MOUNTING: CONCEALED EDGE PROFILE: SQUARE FRAME: TBD BRAILLE WHERE REQUIRED. PROVIDE METAL SIGNS AS NOTED. ALL SIGNAGE TO COMPLY WITH ADA REQUIREMENTS FINAL GRAPHICS TO BE APPROVED BY ARCHITECTS TEMPORARY SIGNAGE TO BE SUPPLIED BY OWNER METAL BASE WITH RAISED LETTERING AND SIZE: MIN. 1/16" THICK X LENGTH AND HEIGHT AS INDICATED. TEXT AND LETTER STYLE: AS INDICATED, ACID ETCHED GRAPHICS TO CONFORM TO ADA REQUIREMENTS. ACCEPTABLE PRODUCT: EQUITABLE TO SERIES 322 FRAME ALL SIGNAGE TO BE COORDINATED WITH CLIENT SIGNAGE VENDOR CONDITIONS OF APPLICATION AND USE. PROVIDE CONCEALED FASTENERS OR ADHESIVES AS RECOMENDED BY MANUFACTURERS AND AS REQUIRED FOR PERMANENT AND SECURE MOUNTING TO SUBSTRATES INDICATED. SUITABLE FOR 9" ELEVATOR FLOOR SIGN STAIRWELL SIGN DIRECTIONAL SIGN 1 DIRECTIONAL SIGN 2 9" 18" MIN CLR.5'-0"MOUNTING HEIGHT SHALL BE 60 INCHES (1524 MM) ABOVE THE FINISH FLOOR TO THE CENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES (76 MM) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. · CHARACTERS ON SIGNS SHALL BE RAISED 1/32 INCH (0.794 MM) MINIMUM AND SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIED BY CONTRACTED (GRADE 2) BRAILLE ·RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8 INCH (15.9 MM) AND A MAXIMUM OF 2 INCHES (51 MM) HIGH. · PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE DIMENSION OF THE PICTOGRAM FIELD SHALL BE A MINIMUM OF 6 INCHES (152 MM) IN HEIGHT. ·CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCH (9.5 MM) AND A MAXIMUM OF 1/2 INCH (12.7 MM) DIRECTLY BELOW THE TACTILE CHARACTERS; FLUSH LEFT OR CENTERED. WHEN TACTILE TEXT IS MULTILINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT. MENS TOILET ROOMS SHALL BE 1/4" THICK TRIANGLE, 14" X 14" X 14" THE SYMBOL SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR. (CBC 1115B.5). WOMENS TOILET ROOMS SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK, 12" DIAMETER OR 54" MIN (24" MIN. IF EXTERIOR )48" MIN, 60" MAX39"-41" EXIT (BRAILLE)6"6"48" MIN, 60" MAXAFF - BOTTOM OFBRAILLETYPICAL MOUNTING HEIGHT 5 8" HIGH 18"MIN.18" MIN. CL CENTERED ON RAISED CHARACTERS 6" 09/16/20