Loading...
HomeMy WebLinkAboutA101 Floor PlanDN 1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE A3S. 2. EXISTING EXTERIOR WINDOW SHADES TO REMAIN. REPAIR AS NEEDED. 3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION. 6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS. GENERAL NOTES KEYED NOTES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WALL TYPES FILES 210 BREAK 211 RECEPT. 200 CONF. 201 I.T. 202 CORRIDOR 212 OFFICE 203 OFFICE 204 OFFICE 205 OFFICE 206 OFFICE 207 OFFICE 208 STORAGE 209 FE 1 2 3 4 1/A5002/A500 5 210209 208207206205204203200201A 201B2026 7 8 LEGEND NEW CONSTRUCTION EXISTING TO REMAIN X1 DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. DOOR AND FRAME WALLWALL AREA NOT IN CONTRACT AREA OF WORK PLUMBING RISER DIAGRAM TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE MA I N BLDG. W A S T E 2" WA S T E TO C.O.2" V.SINK MAIN BLDG. VENT 2" VENT TO [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN. N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19808.14.20BWSB/BDAIR APPLICATIONS101 E. CARMEL DRIVE -SUITE 230CARMEL, INDIANA 46032A101 FLOOR PLAN 1 PROVIDE NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET. PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH NFPA 10. 2 PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. 3 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. SINK- ELKAY, CROSSTOWN #ECTRU24179R (STAINLESS STEEL) FAUCET - DELTA, MATEO, SINGLE-HANDLE PULL-DOWN FAUCET, ARTIC STAINLESS FINISH. 4 FIXED WALL MOUNTED TELEVISION SUPPLIED BY TENANT. CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. 5 DISHWASHER SUPPLIED BY TENANT, CONTRACTOR INSTALLED.COORDINATE ANY PLUMBING LINES NEEDED WITH TENANT. 6 PROVIDE NEW (5) HIGH, 18" DEEP, ADJUSTABLE HEAVY-DUTY WHITE MELAMINE SHELVING ON KV STANDARDS AND BRACKETS. PROVIDE BLOCKING AS REQUIRED. 7 PORTIONS OF EXISTING EXTERIOR WALL HEADER AND/OR SILL UNFINISHED. PROVIDE FINISHED DRYWALL APPEARANCE, PREP FOR PAINT. 8 PROVIDE 18" DEEP, HEAVY-DUTY WHITE MELAMINE SHELF ON KV STANDARDS AND BRACKETS. PROVIDE BLOCKING AS REQUIRED. CONFIRM WIDTH AND INSTALL LOCATION WITH TENANT. 1/4" = 1'-0" FLOOR PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION09/16/20