HomeMy WebLinkAboutA101 Floor PlanDN
1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE
TYPE A3S.
2. EXISTING EXTERIOR WINDOW SHADES TO REMAIN. REPAIR AS NEEDED.
3. PROVIDE BRACING AND FIRE-TREATED BLOCKING AS REQUIRED IN WALLS
SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM
ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL
SUPPORT.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE
INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM
LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION.
6. ALL APPLIANCES TO BE PROVIDED BY TENANT. APPLIANCES FOR BASIS OF DESIGN
ONLY, TENANT TO CONFIRM AND COORDINATE FINAL APPLIANCE SELECTIONS.
GENERAL NOTES
KEYED NOTES
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
REFRENCE A004 FOR WALL TYPE DESCRIPTION. NOT ALL WALL TYPES
LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED
CEILING PLAN FOR CEILING HEIGHTS.
WALL TYPES
FILES
210
BREAK
211
RECEPT.
200
CONF.
201
I.T.
202
CORRIDOR
212
OFFICE
203
OFFICE
204
OFFICE
205
OFFICE
206
OFFICE
207
OFFICE
208
STORAGE
209
FE
1
2
3
4
1/A5002/A500
5 210209
208207206205204203200201A
201B2026
7
8
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
X1
DOOR AND
FRAME
(SEE DOOR
SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
DOOR AND
FRAME
WALLWALL
AREA NOT IN CONTRACT
AREA OF WORK
PLUMBING RISER DIAGRAM
TYPICAL ALL SINGLE LOCATIONS NOT TO SCALE
MA
I
N BLDG. W
A
S
T
E
2"
WA
S
T
E
TO
C.O.2" V.SINK
MAIN BLDG. VENT
2" VENT TO [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19808.14.20BWSB/BDAIR APPLICATIONS101 E. CARMEL DRIVE -SUITE 230CARMEL, INDIANA 46032A101
FLOOR PLAN
1 PROVIDE NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET. PLACEMENT IS FOR
GENERAL REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE
WITH NFPA 10.
2 PROVIDE WATER LINE FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT.
3 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET.
PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. SINK- ELKAY,
CROSSTOWN #ECTRU24179R (STAINLESS STEEL) FAUCET - DELTA, MATEO,
SINGLE-HANDLE PULL-DOWN FAUCET, ARTIC STAINLESS FINISH.
4 FIXED WALL MOUNTED TELEVISION SUPPLIED BY TENANT. CONTRACTOR
INSTALLED. COORDINATE EXACT LOCATION WITH TENANT.
5 DISHWASHER SUPPLIED BY TENANT, CONTRACTOR INSTALLED.COORDINATE ANY
PLUMBING LINES NEEDED WITH TENANT.
6 PROVIDE NEW (5) HIGH, 18" DEEP, ADJUSTABLE HEAVY-DUTY WHITE MELAMINE
SHELVING ON KV STANDARDS AND BRACKETS. PROVIDE BLOCKING AS REQUIRED.
7 PORTIONS OF EXISTING EXTERIOR WALL HEADER AND/OR SILL UNFINISHED.
PROVIDE FINISHED DRYWALL APPEARANCE, PREP FOR PAINT.
8 PROVIDE 18" DEEP, HEAVY-DUTY WHITE MELAMINE SHELF ON KV STANDARDS AND
BRACKETS. PROVIDE BLOCKING AS REQUIRED. CONFIRM WIDTH AND INSTALL
LOCATION WITH TENANT.
1/4" = 1'-0"
FLOOR PLAN1 REVISION SCHEDULEMARK DATE DESCRIPTION09/16/20