HomeMy WebLinkAboutA500 Interior ElevationsMILL/CASEWORK NOTES
1. CAULK SELECTIONS ARE TO BE PROVIDED TO PARALLEL
DESIGN GROUP FOR SELECTION AND/OR APPROVAL BEFORE
INSTALLATION OF MILLWORK.
2. SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR
PAINTED AS SPECIFIED) TO PARALLEL DESIGN GROUP FOR
REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS
OF ALL MILLWORK.
3. CASEWORK AND MILLWORK GENERALLY INDICATED ON
THESE DRAWINGS ARE TO BE PROVIDED UNDER THE
GENERAL CONTRACT.
4. UNLESS INDICATED OTHERWISE, COMPLY WITH
ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT
STANDARDS FOR CUSTOM GRADE WOODWORK.
5. FURNISH SHOP DRAWINGS ON ALL MILLWORK AND
CASEWORK FOR APPROVAL BY THE TENANT AND PARALLEL
DESIGN GROUP PRIOR TO FABRICATION. PROVIDE SEAMING
DIAGRAM TO PARALLEL DESIGN GROUP.
6. WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED,
VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF
AS-BUILT CONDITIONS IN FIELD. REPORT ANY
DISCREPANCIES TO PARALLEL DESIGN GROUP THROUGH THE
GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO
CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS
UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT
OF THE DESIGN SHOWN ON THE DRAWINGS.
7. UNLESS OTHERWISE SHOWN, PROVIDE 25" DEEP, PLASTIC
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES
WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED.
8. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT
INDIVIDUAL UNITS OF WORK AT INDUSTRY RECOGNIZED
STANDARD MOUNTING HEIGHTS FOR THE PARTICULAR
APPLICATION AND REFER QUESTIONABLE MOUNTING HEIGHT
CHOICES TO PARALLEL DESIGN GROUPS FOR FINAL
DECISIONS.
9. PROVED CABINETRY HARDWARE:
MFG: RICHELIEU
PRODUCT: BP56325128174
SIZE: 5" CENTER TO CENTER
FINISH: MATTE CHROME
3' - 0" 1' - 6" 3' - 0"2' - 10"2' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
3" 3' - 0" 1' - 6" 3' - 0"
(HOLD)
2' - 0" 2' - 6" 1' - 6 1/8"3' - 0"1' - 6" 3' - 0" (HOLD)
3' - 7" 2' - 0"
3' - 0" [PROJECT NUMBER][DATE][DRAWN BY][CHECKED BY]ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.
N [ P ][ W ]Indianapolis, IN 46240ParallelDG.com317.721.4399 8940 River Crossing Blvd. Ste 1502020.19808.14.20BWSB/BDAIR APPLICATIONS101 E. CARMEL DRIVE - SUITE 230CARMEL, INDIANA 46032A500
INTERIOR
ELEVATIONS
DISHWASHER
(BY TENANT)
3/4" = 1'-0"
BREAK 211 -A13/4" = 1'-0"
BREAK 211 -B 2
REFRIGERATOR
( BY TENANT)
25"D SOLID SURFACE COUNTERTOP,
4"H BACKSPLASH (SS1)
12"D PLASTIC LAMINATE
UPPER CABINETS (PL1)
UNDER CABINET LIGHTING,
CONCEAL WITH FASCIA (PL1)
PROVIDE UNDERMOUNT SINGLE BOWL
SINK AND FAUCET W/ DISPOSAL, REFER TO
SHEET A101 FOR SPECIFICATION
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
24"D PLASTIC LAMINATE TRASH CABINET,
ROLL OUT, DOUBLE-BIN (PL1)
4"H VINYL BASE (VB2)
25"D SOLID SURFACE COUNTERTOP,
4"H BACKSPLASH (SS1)
12"D PLASTIC LAMINATE
UPPER CABINETS (PL1)
24"D PLASTIC LAMINATE
BASE CABINETS (PL1)
4"H VINYL BASE (VB2)REVISION SCHEDULEMARK DATE DESCRIPTION09/16/20