GENERALNOTES
A. REFERTO�RAWINGE001FORELECTRICALSYMBOLSAN�A��ITIONALGENERALNOTES.
8. COORDINATEALLWORKWITHTHEOWNERANDTHEOTHERTRADESONTHEPROJECT.
C. REFER TO M AND P SERIES DRAWINGS FOR AD�ITIONAL ELECTRICAL RE�UIREMENTS.
�. PROTECTALLFINISHES,Ep01PMENT,AN��EVICES�URINGTHEWORK.
E REFERTOARCHITECTURALSCHE�OLES.�ETAILS,AN�ELEVATIONSFORA��ITIONAL
WFORMAiION ON DEVICE LOCATIONS PRIOR TO ROUGH�IN.
F. COOR�INATE ALL WORK WITH THE OWNER'S SYSTEMS VEN�ORS FOR �EVICES AN�
WIRING FOR �ATA, I.T. SERVICES, AN� SECURITV SYSTEMS.
G. ELECTRICAL SERVICES SHALL NOT ROUTE THROUGH ANV I�F OR M�F ROOM UNLESS
�IRECTLY SERVING THAT 1 ROOM.
H. CONTRACTORSHALLVERIFVCORDAN�PLUGCONNECTEDE�UIPMENTCORD
CONFIGURATION AN� PROVIDE MATCHING RECEPTACLE AS REp01RE�.
I. ALLRECEPTACLESWITHINSIXFEETOFASINKSHALLBEGFCITVPE.�EVICESMAVNOTBE
IDENTIFlED AS GFCI ON PLANS, BUT SHALL BE PROVI�E� ACCORDING TO THE
REQUIREMENT.
J. ALLSPECIALTYPERECEPTACLESSHALLBENEMAfidORUNLE55NOTEDOTHERWISEAND
9HALL BE qRCUITED WITH (2) k10 �(1) %10 N WTRAL t(1 �#1p GROUND. COORDINATE
REQl11REMEN-Slh'I-HOWNERSUPPLIE� EQUIPMENTPRIORTOINSTALLATION.
K. COORDI�ATEINSTALLATIONOFLIGHTFlXTURESWITHARCHITECTURALRERECTED
CEILING PLAN, ARCHITECiURAL ELEVATIONS, HVAC E�UIPMENT, DIFFUSERS, �UCTWORK,
PIPING. SUPPORTS. A\� STRUCTIIRE PRIOR TO ROOGH-IN.
L. ALLEHITSIGNS.EMERGENCYBATTERVLIGHTINGIINITS,AN�LIGHTFIXTURE55HOWN
WITH EMERGENCY BATTERV BACKUP OR IN�ICATED AS A NIGHi LIGHT ("NL") SHALL BE
PROVI�E] WRH AN UNSWITCHE� "HOT" QRCUIT CON�UCTOR.
M. AT_OCATIONSWITHTWOORMOREWALLSWITCHES.ALLSWITCHESSHALLBEINSTALLE�
CANGEOINA COMMONSWITCHBO%.
N. AT_OCATIONSWHERELIGHTSWITCHESAN�ABOVECOUNTERRECEPTACLESARETOBE
NOUNTEO ADJACENT W EACH OTHER, THE DEVICES SHALL BE INSTALLED AT THE SAME
HEIGHT
0. WHEREOCCl1PANCY5EN50R5AREIN�ICATE�ONPLANS.THEENTIRER00M5HALLBE
COVERE�.SENSOR MANUFACTORERISRESPONSIBLEFORSENSORLAYOUT.
A�DITIONAL SENSORS RE�UIRED DUE TO LACK OF COVERAGE SHALL BE iHE
RESPONSIBILITVOFTHEELECTRICALCONTRACTOR. PROVI�EQIIANTITIE5A5
RE�UIRED. CEILINGANDWALLMOUME�SENSORSSHALLBEDUALTECHNOLOGYTYPE.
SENSORS SHALL INCLU�E� ALL POWER SUPPLIES AN� RELAVS NECESSARV TO CONiROL
LIGHT FIXTURES IN ROOM�AREA. SENSORS SHALL OPERATE IN "VACANCY" MO�E -
MANUAL ONIAUTO OFF.
P. PROVIDEPULLSTRINGINALLEMPiYCON�UITS.
p. CONTRACTOR TO PROVI�E ROUGH-INS ONLV FOR �ATA, I.T. SERVICES, AN� SECURITV
SVSTEMS. DATA, I T. SERVICES. AND SECURITY SVSTEMS �EVICES AND WIRING TO BE
PROVI�E� BY iHE OWNERS SYSTEMS VEN�ORS
PLAN NOTES
1 PROVIDE (1) 4' %8' X 3/4" THICK A-C GRADE, V010.FREE PLVWOOD MAT FROM FLOOR T0
8'-0"HIGHFORTELECOMBACKBOARD. PAINTALLFACESAN�E�GESOFPLYW00�
� ! �. O : ��O.O SECTIONSWITHAMINIMUMOFTWOCOATSOFFIRE�RETAR�ANTPAINTPRIORTO
wsruinnoN.
2 PROVI�E(2�4"SLEEVESTOSECON�FLOORELECTRICALROOMPoRFUTUREDATA.
�'� `� '�,k..
�- - -�- - -��- -
- -�- - -I�- -
z�,-�
�
z�,� ry �
i-2L1—� 6 p �
- - - -�- - - - - - -�- - - - �z�,-� �- - -�
I I I I I I
_ — — — � — — — — — — — � — — — — � — — � — — �
I — I _ _ _ _ I— — — — — � — — _ — — — � — — _I
— I_ _ _ _ _ � — — — � — —
I p��-J� � CORRIDOR I I z��-Z� I
�I �' /� � ioa � .
�1 1 �
� V /
I I V/ I I
X
/\
I � � I
I I I I I I I
I I I I I I
%� SECOND LEVEL POWERISYSTEMS PLAN
118",1��"
CCORNERSTONE
■■
lrmcau
�■ STRUCTUREPOINT
inC
�
CARMEL MEDICAL
ARTS PAVILION
12174 N. Meridian Street
Carmel, Indiana 46032
= No. '
-°� 19700101�:�=
yO., SiAiE OF �:
:,`., � p+2�
��SS/ONAL F-�G•
� �•yn�niinioo
C�ERTIFIED BY�
ISSUANCE INDEX
DATE:
05.22.2020
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
E302
Project Number 2019.00780
SECONDLEVEL
POW ER/SYSTEMS
PLAN