Loading...
HomeMy WebLinkAboutE501 - ELECTRICAL ONELINE RISER DIAGRAM� Q N RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel 'v�:���� i�.va�� . DATE: O$�Z4�2O � I F400 3H1 2]]IGBOV 3P-0W JOOA MLO � _ T 2L1 120i208V ]5 KVA 3P-4W ��� P25A MCB F400 2H1 2]]I480V T2_1 3P�4W ]5 KVA ,aoA � � MLO F,�S � MDP O I 2]L480V 3P.aW SB�V 1200A nury Q Mca iFORMER I �I� _ � _ O 1201208V I 3P 46V 225A MGB SECONDFLOOR I _ _ THIRDFLOOR F125 F225 (1) M2 AL GN�, 314'C TO BUILDING GROUN�ING SYSTEM. I T.�u ]5 KVA F125 1� ELECTRICAL ONE-LINE RISER DIAGRAM NO SCALE F400 iH1 znweov 3P.4W a00A MLO (1) %3/0 Cu GN�, 1"C TO ELECTRICAL SERVICE GROUND ROD RELD (1 � q310 Cu GN�, 1"C TO INCOMING NATRUAL GAS SERVICE PIPE WHERE RE�UIRED AND PERMITTED BY CODE �i � k310 Gu GND,1'C TO BUIL�ING STEEL GROUN� WALL MOIINTE� 114"x6"Hx24"W GROUNDBUSBAR O [ O O O O O O � � (1)q1ALGN�.314'CTO PANELMHi' (1)q1ALGN�.314'CTO PANEL2H1' (1�q1ALGN�.314'CTO PANEL'3H1' 4 5 6 RRST FLOOR ELECROOM'M�P' 0 0 0 0 O O O O O O O O � O O O � o 0 O O O O O O O 0 0 0 Fz�S (1) A2 AL GN�, 3l4"C TO BUIL�ING G40UNDING SYSTEM. izaizoav 3P-4W 125A MCB _ � I I FIRST FLOOR F225 (1) M2 AL GN�, 314'G TO BUILDING GROUNDING SYSTEM. (t) #31� Cu GND, 1"C TO UFER GROUND (1) #310 Cu GN�. 1"C TO INCOMING WATER SERVICE PIPE �� MAIN DISTRIBUTION PANEL'MDP' GROUND BUSBAR DETAIL �J NO SCALE PLAN NOTES 1 PROVIDE(2)4"CONDUITSFORELECTRICPRIMARYCONOUCTORSTOSERVETHEUTILINTRANSPoRMER. TRANSFORMER PRIMARV CON�UCTORS INSTALLE� BY UTILIN. 2 METERFURNISHEDBYTHEUTILITYANDWSTALLEDBVCONTRACTOR.PROVIDE2-112"CONDUITFROM TRANSFORMER TO METER AS REQUIRE�. 3 REFERTOGROUNDING�ETAILONTHISSHEETFORADDITIONALMFORMATION. 4 BON�ALLMETALPIPING�ESCRBE�INNFPAIO-25�.104,INCLU�INGGASPIPING. 5 GROUN�INGCON�UCTORS SHALL BE INSTALLE� IN CON�UIT WHERE INSTALLEDABOVE GRA�E. 6 CONNECTWATERSERVICEGROUNDMGCON�UCTORTOSTREETSIDEOFWATERMETER. PROVI�EBONDING JUMPER ACROSS WATER METER AN� INSTALL WITH TAG. FEEDER AND BRANCH CIRCUIT SCHEDULE NOiE: SEE DRAWINGS FOR NUMBER OF WIRES IN HOMERUN CONDUCTORS2E TYPECA9LE CONOUIT FEEDERIBRANCH CIRCUIT �ESIGNATION pXA5E8NE0TRAL EQOIPMENT p�UMINOM COPPER GROUND F20 1P 12 X MC F30 1� 10 X MC F40-50 0 10 X MC F60 6 10 X MC F]0-80 4 8 X MC F90 3 8 X MC F1�0 3 8 X MC F125 ll0 4 X MC Fi6a YO 4 X 2-1/Y Fns aio a x vvr Fzoa zso a x a� F225 300 2 X 3' F25a �50 2 X 3' F3�0 500 2 X 3-11Y Po60 2RUNSOF610 1 X 2-112' Fd00 2RUNSOF250 1 X 3"EACH F600 2 RUNS OF 500 2I0 % 3412" EACH F800 3 RUNS OF A00 310 X 9412" EACH F1000 3 RUNS OF 600 410 X 4'EACH F1200 a RUNS OF 500 250 X 3412"EACH F1600 5 RUNS OF 600 350 % 4"EACH F2000 6 RUNS OF 600 400 X 4"EACH F2500 ]RUNSOF750 fi00 X 5"EACH FJ000 BRUNSOF750 fi00 X 5"EACH NOTES: 1. 20 A BRANCH QRCUITS SHALL BE SRE� FOR VOLTAGE �ROP. WIRE SIZES ARE NOT IN�ICATE� ON THE �RAWINGS TO COMPENSATE PoR VOLTAGE �ROP. PoR THESE CIRCUITS, CONTRACTOR SHALL UTILIZE WIRE SIZE SHOWNABOVE FOR DISTANCES LISiED ABOVE. 2 VOLTAGE�ROPWIRESIZESWILLBESTRICTLYINFORCE�.CONTRACTORSHALLSOBMITALISTOFCIRCUITSTHATWILL EXCEED THE DISTANCES ALLOWED AND INDICATE WIRE SI2E TO BE USED PRIOR TO ANY WIRE BEMG WSTALLE�. 3. DONOTSHARENEUTRALCON�UCTORSFORANYBRANCHCIRCUITS.ALLBRANCHCIRCUITSHALLHAVESEPARATE, IN�EPEN�ENTNEUTRALCON�IICTORS. a. ALLBRANCHCIRWITWIRINGSHALLBEMCCABLEWITHTHEFOLLOWINGEXCEPTIONS�. a. ALLWIRINGCONNECTEOTOTHEEMERGENCYILIFESAFETYPOWERSYSTEMSHALLBEINSiALLEDINCONDUIT LOMPLETE. b. ALLWIRINGTHATISINSTALLEDINAREASTHATDONOTHAVECEILINGSORWHEREWIRINGWOULDBEE%POSED SHALLBEINSTALLE�IN CON�UIT COMPLEiE. 5. ALLCON�UITPENETRATIONSTHROTHEFLOORSLABSHALLBEMA�EWITHCAUTION.CONTRACTORSHALL COORDINATE ALL HOLE LOCATIONS WITH STRUCTURAL ENGWEER PRIOR TO CUTTING ANV NEW HOLES. NEW HOLES SHALL BE A�JUSTE� AS REQUIRE� TO MISS REBAR AS �ETERMINE� BY THE STRUCTIIRAL ENGINEER. VOLTAGE DROP FOR 20A BRANCH CIRCUITS MAXIMUM OISTANCE ALLOWEO FEEOERSIZETOOSE 120V Z��� F20 100 FEET 200 FEET F3� 150FEET 360FEET F40-50 240 FEET 550 FEET F6� 385 FEET 885 FEET NOTES 1. CON�UCTORS FOR 20 AMP BRANCH CIRCUITS SHALL BE SIZE� FOR VOLTAGE �ROP. WIRESIZESARENOTINDICATE�ONTHEDRAWINGSTOCOMPENSATE FOR VOLiAGE DROP FOR THESE CIRCUITS. CONTRACTOR SHALL UTILIZE WIRE SIZE SHOWN ABOVE FOR THE �ISTANCES LISTE� ABOVE. 2. VOLTAGEDROPWIRESIZESWILLBESTRICTLVENFORCE�.CONTRACTOR SHALL SUBMIT A LIST OF CIRCUITS THA wILL EXCEED THE DISTANCES ALLOWE� AN� IN�ICATE WIRE SIZE TO BE USE� PRIOR TO ANY WIRE BEING INSTALLE�. J. PROVIDESEPARATE.INDEPENDENiNEUTRALCON�UCTORSFORALLBRANCH CIRCUITS. �ONOSHARENEIITRALSBETWEENCIRCl11T5. �,� VOLTAGE DROP SCHEDULE �J NO SCALE INFORMATION PLATE LAMACOID PLATE PANEL1LN1 Eo��PMENTSER�Eo 1201208V 3P 4W. vo�rnce FEDFROMMDP 5ouaceoFPoweR NOTB PROVIDEID.PLATELABEL FOR ELECTRICAL EQUIPMENT SUCH AS MAIN S W ITCHG EAR, SWITCNBOAROPANELBOAR�S, ANDTRFNSFORMERS �� ELECTRICAL EQUIPMENT I.D. LABELING DETAIL NO SCALE Arc Flash Hazard Appropriate PPE Required Equipmen�Type 480VSwitchgear Grounding Gmunded Work Oie[anca 11 Inchae (300 mm) Availiable 3-Ph Bolted Current 25 kA Flash Proteclion Boundary 2] inches Incitlen� Energy a� 71 inches 4.39 caVcm2 RiskCategory 2 Equipmenl Name: Switchboard NOTE: PROVIDE WARNING LABEL FOR ALL ELECTRICAL EQUIPMENT SUCH AS MAIN SWITCHGEAR,SWITCHBOARDS,PANELBOARDS,AND TRANSFORMERS. �� ELECTRICAL EQUIPMENT WARNING LABEL DETAIL NO SCALE CCORNERSTONE ■� �Fmcau �■ STRUCTUREPOINT inc CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 No. 19700101 SiAiE OF 'V--�c) �--s CERTIFIED BY ISSUANCE INDEX DATE: 05.ZZ.Za20 PROJECT PHASE: CONSTRUCTION DOCUMENTS E501 Prqect Number 2019.00780 ELECTRICAL ONELINE RISER DIAGRAM