Loading...
HomeMy WebLinkAboutP000- SYMBOLS AND ABBREVIATIONS� ABBREVIATIONS AND TERMS ¢ DIAMETER PHASE ID INSIDEDIAMETER `F �EGREESFAHRENHEIT IE INVERTELEVATION A COPRESSE�AIR IN INCH INCHES A� AREA �RAIN, ACCE55 �OOR INT INTERIOR AFF ABOVEFlNISHE�FLOOR INV INVERT AGA AMERICANGASASSOCIATION IPS INTERNATIONALPIPESTAN�AR� AN51 AMERICANNATIONALSTAN�ARDSMSTITUTE IW INDIRECTWASTE AP ACI�PROOF.ACCESSPANEL KEC KITCHENEQUIPMENTCONTRACTOR APPROX. APPROXIMATELV kW NILOWATT ARCH ARCHITECT LAB LABORATORY ASME AMERICANSOqETYOFMECHANICALENGMEERS L LAVATORV ASPE AMERICANSOQETVOFPLUMBINGENGINEERS LBS POUN�S ASTM AMERICANSOQETVFORTESTINGAN�MATERIALS LF LINEARFEET AUTO AUTOMATIC LP LIpUIDPETROLEUM AVG AVERAGE MAX MAXIMUM AVS ACI�VENTSTACK MB MOPBASIN AW ACI� WASTE MBH THOUSAN� BW PER HOUR AWWA AMERICANWATERWORKSASSOCIATION MC MECHANICALCONTRACTOR BF 9ARRIERFREE MCA MINIMUMCIRCUITAMPS BFC BELOWFlNISHE�CEILING MFR MANUFACTURER BHP 9RAKEHORSEPOWER MH MANHOLE BLDG BOIL�ING MIN MINIMUM BOP BOTTOM OF PIPING MISC MISCELLANEOUS BSMT BASEMENT N NITROGEN BT 9ATHTUB NA NOTAPPLICABLE 8TM BOTTOM NC NORMALLYCLOSE� BWH 9RITISHTHERMALUNITPERHOOR NEC NATIONALELECTRICCO�E CA COMPRESSEDAIR NFC NATIONALFIRECODE CB CATCHBASIN NFPA NATIONALFIREPROTECTIONASSOCIATION CD CON�ENSATE�RAIN NIC NOTINCONTRACT CO CARBONDIOXI�E NO NORMALLYOPEN,NIiROUSOXIDE CFM CUBICFEETPERMINUTE NOM NOMINAL Q CASTIRON NP NON-POTABLEWATER CMP CORRUGATEDMETALPIPE NTS NOTTOSCALE CO CLEANOUT 0 OXVGEN W CICRULATORPUMP OD OUTSIDEDIAMETER CPVC CHLORINATE�POL1'VINVLCHLORI�E CW COLDWATER OFlCI OWNERFURNISHED/CONTRACTORINSTALLED CWP CONDENSERVVATERPUMP OSD OPENSITE�RAIN DBP DOMESTICBOOSTERPUMP OW OILWASTE �CVA �OUBLECHECKVALVEASSEMBLY OZ OUNCE DF DRINKINGFOUNTAIN P P��MP DH �RENCHHOSE RGP REINFORCEDCONCRETEPIPE DIA �IAMETER R� ROOFDRAINIROP DN DOWN PE POLYETHYLENE �S DOWNSPOUT PH PHASE �W �ISTILLE� WATER PIV POST INDICATOR VALVE DWG DRAWWG PP POLYPROPYLENE DWV DRAIN,WASTEBVENT PPM PARTSPERMILLION EA EACH PRV PRESSUREREDUCINGVALVE EC ELECTRICALCONTRACTOR PSI POUN�SPERSpUAREWCH ECO EXTERIORCLEANOUT PSIG POUNDSPERS�VAREINCHGAUGE EFF EFFIQENCV PVC POLYVINVLCHLORI�E EL ELEVATION PW PIIREWATER ES EMERGENCYSHOWER RM ROOM EEW EMERGENCYEVEWASH RPBP REQUIREDPRESSUREBACKFLOWPREVEMER EWC ELECTRICWATERCOOLER RPM REVOLUTIONSPERMINUTE E% E%ISTING SAN SANITARY FCO FLOORCLEANOUT SF SOIIAREF00T,SUPPLVFAN,SAFETYFACTOR FD FLOOR�RAM RREDAMPER SG SPECAILGAS F�C FIRE�EPARTMENTCONNECTION SH SHOWER FH FUMEH00� SK SINK FHC RREMOSECABINET SPEC SPECIFICATION FLR FLOOR 55 SERVICESINK,STAINLESSSTEEL FM FACTORVMUTUAI STD STANDARD FPM FEETPERMINUiE T TURRET FSC FlRE Sl1PPRE5510N CONTRACTOR TD TRENCH DRAIN FT FOOT,FEET TDH TOTALDVNAMICHEA� FTG FOOTING TEMP TEMPERATORE G NATURALGAS TET THERMALEXPANSIONTANK GA GAGEORGAUGE TMV THERMOSTATICMIXINGVALVE GAL GALLON TP TRAPPRIMER GC GEVERALCONTRACTOR TS TAMPERSWITCH GPD GALLONSPER�AY GPH GALLONSPERHOUR iVP iVPICAL GPM GALLONS PER MINUTE 11L UNDERWRRERS LABORATOPoES GT GREASETRAP UON 11NLE550THERWISENOTE� GW GREASEWASTE 11R IIRINAL HB HOSEBIBB V VOLTS VENT HD HEAD�R.) VAC VACOIIM Hu MERCURV VB VACOUMBREAKER HO HUBOUTLET VFD VARIABLEFRE�UENCVORNE HP HORSEPOWER,HEATPUMP �TR VENTTHROUGHROOF HR HOUR�S) W WASTE,WATT HW HOTWATER �M1'B WASHERBOX HWR HOT WATER RETURN WC WATER COLUMN, WATER CLOSET HX HEATEHCHANGER WCO WALLCLFANOIIT HV� WALLHY�RAM WSB WATERSUPPLVBOX n� nERrz vo vnRooRnw RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel `v�a��\i 1�.rvalp/f �. DATE: O$�Z4I2O PIPING IDENTITY SYMBOLS FLOWDIRECTIONARROW PITCHDIRECiIONARROW � O PIPERISE J - PIPE�ROP PIPE CAP PIPE CONTINUES (REFERENCE ELSEWHEREJ — PIPEGUI�E 3E PIPEANCHOR II II EXPANSIONLOOP �li �II� uNioN,FUNCEouNioN � GATE VALVE F(�i BALL VALVE CW GLOBEVALVE �r� BUTfERFLVVALVE �7, PWGVALVE N CHECKVALVE � PRESSUREREDUCINGVALVE REDUCED PRESSURE BACKFLOW PREVEMER DOUBLE CHECK BACKFLOW PREVEMER O~ DOU&EDETECTORCHECKVALVEASSEMBLY �— ANGLEVALVE � RELIEFVALVE � VALVEWITHOUTSI�ESTEMBVOKE � SOLENOIDVALVE Q FLOWSWITCH 4 PRESSURESWITCH Q A�UASTAT � BALANCEVALVE STRAINER STRAINER WRH CAPPE� BLOW�OWN } MANUALAIRVENT Q AUTOMATICAIRVENT g VACUUMBREAKER * TEMPERATUREIPRESSURETAP 4 THERMOMETER Q PRESSUREGAUGE � AIRFlLTERI�RVEF � INLINEPUMP WHA.A T — WATERHAMMERARRESTERWITHSCHE�ULETYPE � Fo a-rRnanNORisER �2"F�-0 FLOOR�RAINWRHSIZE85CHE�ULEiYPE I CO EN�OFPIPECLEANOUT O FCO FLOORCLEANOIIT T WCO yyq��CLFANOUT � EXTERIORCLFANOOTORRO��INGHOLE ECO 7-+HB-0 7-+WH-0 HOSEBIBB,WALLHY�RANTWITHSCHE�ULETYPE OM I WATERMETER OG I GASMETER O4'R� O4'OF� ROOF�RAIN,OVERFLOW�RAINWITHSIZE � POSTINDICATORVALVE � FlREDEPARTMENTCONNECTION VALVE TAMPER SWITCH � UPRIGHTSPRINKLERHEAO � < PENDANTSPRINKLERHEAO � O DRYPENDANTSPRINKLERHEAD � CONCEALEDSPRINKLERHEAD � 4 SIDEWALLSPRINKLERHEAD PIPING LINE SYMBOLS STORM DRAIN CON�ENSATE DRAIN SANITARV WASTE (W) SANITARV6REASE SANITARV FORCED MAIN 9ANITARYVENT(VJ ACID WASTE ACID VENT DRAIN INDIRECiWASTE PUMP DISCHARGE DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER SUPPLV (HW) DOMESTIC HOT WATER RETURN (HWR) id0`F HOT WATER ta0`F HOT WATER RETURN NON-POTABLEWATER CONDITIONED SOFT WATER CHLORINATED WATER DISTILLE�WATER DEIONIZE�WATER FIRE SUPPRESSION NATURAL GAS (WC OR PSIGJ GASVENT LI�UID PETROLEUM ME�ICAL COMPRESSED AIR (WC OR PSIG) ME�ICALVACUUM OXVGEN NITROGEN NITROU50%I�E CAReON DIO%I�E WET VACUUM GLEANING DRV VACUUM CLEANING COMPRESSED AIR (WC OR PSIG) TEMPERE� WATER SUPPLY RA�ON ST co SG FM —__—__—_y'_______— AW ________py_______— 0 IW — PD 140°F 140°F NPW CL DI DE F G GV LP MA MV 0 N NO COZ WVC ovc q TW R LINETYPE DESIGNATORS THIN CONTINUOUS LWETVPE INOICATE EXISTMG REMS TO REMAIN. INTERMEDIATE DASHED LINETVPE INDICATE E%ISTING REMS TO BE REMOVE�. — INTERMEDIATEORWIDECONTINUOUSLINETVPEINDICATENEW — ITEMS. THIN HALFTONE LINETYPE INDICATE ITEMS BV OTHER DISCIPLINE. � IN�ICATESPOINTOFNEWCONNECTIONTOEXISTINGEQUIPMENT,PIPING OR MATERIALS. � INDICATESPOINTOF�ISCONNECTIONTOEXISTINGE�UIPMENT,PIPIN6 OR MATERIALS. PLUMBING NOTES A. ALLWORNONTHEPWMBING�RAWINGSISNEWAN�BYTHISCONTRACTOR UNLESS OTHERWISE INDICATEo. B. THEPLUMBINGCONTRACTORSHALLWCLUOEINHISBIDALLOWANCES,FEES, AN� COSTS TO COMPLETE THIS PROJECT. C- THEPLUMBINGCONTRACTORSHALLFl1RNISHALLREQl11RE�LABORAND PROVIDE ALL MATERIAL W UIPMENT INCLUOING ALL CONTRACTOR'S SERVICES NECESSARVTO COMPLETE WSTALLATION OF THE REQIIIRED SVSTEMS IN FULL CONFORMITV W ITH APPLICABLE C��ES AND ORDINANCES. THE FINISHED INSTALLATION SHALL BE FONCTIONAL AND COMPLETE IN EVERV �ETAIL INCLU�ING ANV AND ALL SUCH ITEMS FOR COMPLETE AND OPERATIONALSYSTEMS. D. ALLPLUMBINGSVSTEMSTOBEINSTAUEOTOMEETTHERE�UIREMENTSOF THE IN�IANA PLOMBING CO�E �2�O01NTERNATIONAL P W MBING CO�E WITH THELATESTIN�IANAAMEN�MENTS). E ALLSOILWASTEVENT,ANOSTORMPIPINGSHALLBEINSTALLE�ATTHE FOLLOWING MINIMUM SLOPP.118" (� % � PER FOOT GRA�E FOk PIPE SIZES 3" AN� lAROER. ll4" (2% ) PER FOOT ORA�E FOR PIPE SIZE6 21/2" AND 6MALLER. F. CUTTMGANDPATCHINGAN�CORE�RILLI�GFORPLUM9INGWORKSHALL BE THE RESPONSIBILITY OF THE PLUMBING C�NTRACTOR. G. PIPINGAN�/OREQUIPMENTSHALLNOTBESUPPORTE�FROMSTRl1CTORAL MEMBERS WITHOUT PRIOR REVIEW AND APPROVAL FROA4 THE STRUCTURAL ENGWEER. H. ALLDOMESTICWATERPIPINGSHALLBEINSULATE�.REFERTOWSULATION SCHEDULE IN SPECIFICATIONS. I. ALLPLUMBINGFlXTURESANOEQWPMENTSHALLCONPoRMTOALL APPLICABLE ENERGV CONSERVATION CO�ES. J. ALLPIPING,VALVES,ANDACCESSORIESSERVINGEQUIPMENTSHALL CONPoRM TO ALL APPLICABLE ENERGV CONSERVATION CODES. K. ANCILLARVSYSTEMSNOTASSOCIATE�WITHEpUIPMENTSHALLNOTBE INSTALLED SO AS TO INHIBIi SERVICING AN�/OR REMOVAL OF SAID WUIPMENT. L STERILIZE�OMESTICWATERPIPINGSYSTEMINACWR�ANCEWITHSTATE AND LOCAL CO�ES. AND BASE BUILDING SPECIFICATIONS. M. PRIORTOTHEINSTALLATION.FABRICATION,REMOVAL,ORRELOCATIONOF ANY WORK, THE CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE ACTUAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND SHALL FULLY COOR�INATE ALL WORK'NITH THE ARCHITECTURAL PLANS, 6111L�ING STRUCTURE. AN� WORK OF ALL OTHER TRADES. CONTRACTOR SHALL VERIFV E%ISTING INVERTS PRIOR TO CONSTRIICTION. N. FOUN�ATIONAN�FOOTINGSSHALLNOT9EOISTUR9EDWIRiOUTOBTAINING PERM6510N FROM THE ARCHITECT ANDiOR STRUCTURAL ENGMEER. PROPER 11NDERPINNING MEiH0�5 SHALL BE 115ED T� PROTECT AFFECTE� PoUNDATION COMPONENTS. 0. PROVIDEPIPEESCUTCHEONSATEXPOSEDPIPEPENETRATI�NSATALL FlNISHE� WALLS AN� CEILINGS. P. PROVIDESLEEVESFORALLPIPWGTHATPENETRATESFULLHEIGHTWALLS. 0. PROVI�EACHECKVALVEONHOTAN�COLDWATERBRANCHLMESSERVING ALL MOP SINKS. R. PROVIDEWATERHAMMERARRESTERSPRIORTOQUICK�CLOSMGVALVES�ie: ELECTRIC, PNEUMATIC, SPRING LOA�E� VALVES OR DEVICES, pUICK HAN� CLOSUREVALVESORFIXNRETRIM�. SIZEARRESTERSPERSCHE�ULEON DRAwWGS AND POI-WH 201 CERTIFIEO STANDARD. S. INSULATE ALL PLASTIC PIPWG IN RETURN AIR PLENUMS TO MAINTAIN 25150 FIRE SMOKE RATING AN� AS DIRECTE� IN SPEQFICATIONS. INSOlATION MATERIAL SHALL BE llT' GLOSE� CELL ELASTOMERIC, UNLESS OTHERWISE INDICAiED IN PART 3 OF SPEQFlCATION SECTION 220I00. T. WOR�INATEVENTPENETRATIONSWITHMECHANICALROOFTOP E�UIPMENT, REFER TO "H" SERIES DRAWINGS. OFFSET VENTS AS RE�UIRE� TO MAINTAIN MINIMUM 10'-0" SEPARATION FROM AIR INTAKES. U. PROVI�EREA�-FREP,"NO-LFA�".AN�/OR"LOW-LEA�"PLUMBINGFITTINGS COMPLIANT WITH THE FEDERAL LAW IN EFFECT ON JANUARV a, 2014 - MAXIMUM 025% LEAD CONTEM. V. PROVI�EFREEZEPROTECTIONFORALL�OMESTICWATERPIPINGAN� TRAPS INSTALLE� IN ONHEATE� AREAS. USE ELECTRIC HEAT TRACE CABLE AND INCLUDE ALL ACCESSORIES FOR A COMPLETE AUTOMATIC OPERATING FREEZEPROTECTIONSVSTEM. COVERWITHINSULATION. ALLHEAT TRACING COMPONENTS SHALL BE PROVIDE� AN� INSTALLE� BV THE PLUMBINGCONTRACTOR FlNALCONNECTIONTOTHEELECTRICALSYSTEM SHALL BE MADE BY THE ELECiRICAL CONTRACTOR. W. ELEVATOREpUIPMENTR00M5:�ONOTROUTEANY5Y5TEM5THR0UGH ELEVATOR E�UIPMENT ROOMS. FOR SYSTEMS THAT SERVE ELEVATOR EQUIPMENT ROOMS. �0 NOT ROUTE OVER ELEVATOR EpUIPMENT OR ELECTRICAL COMPONENTS. �0 NOT HIN�ER SERVICE ACCE55. X TELECOMMUNICATIONSROOMS:�M�FANDIDF)DONOTROUTEANY SYSTEMS OVER EQUIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCE55. V. ELECTRICALE�UIPMENTROOMS:DONOTROUTEANYSYSTEMSOVER ELECTRICAL E�OIPMENT OR ELECTRICAL COMPONENTS. DO NOT HINDER SERVICE ACCE55. Z. DONOTROUTEANYSVSTEMSABOVEELECTRICALE�UIPMENTOR ELECTRICALCOMPONENTS. REFERENCE SYMBOLS SECTIONINDICATOR'. REFERENCESECTIONLOCATIONTHROUGHANAREA KEVNOTEINDICATOR'. REFERENCESHEETKEVNOTELOCATIONFOR PoR AD�ITIONAL WFORMATION. ADDITIONAL WFORMATION. SECTIONLOCATION BEVON�AREA KEVNOTEINDICATORS INpRAWINGM00ULE EXTENSION NUMERICCHARACTER X P�N POINTLEA�ER X X X RELATES TO REM X ARFALFADER SECTION LOCATION AT SUBSET SHEET LWE LFA�ER �ETAILINDICATOR'. REFERENCE�ETAILLOCATIONFORA��RIONAL �RAWINGBLOCKTRLE REFERENCE�RAWINGMO�ULELOCATIONFOR MFORMATION. INDICATOR: ADDITIONAL WPoRMATION. LARGESCALEVIEWLOCATIONIN DETAILLOCATIONIN DRAWWGMODULELOCATION �RAWINGMO�ULE �RAWINGMO�ULE �IDENTIFYINGLOWERLEFTOFMULTIPLEMO�ULES) x i �i X ' � X DRAWING BLOCK TITL " X �V / X V /) SCALE-118"=1'-0" LARGESCALEVIEW DETAILLOCAiIONAT NOMERICSCALE/ NORTHARROW LOCATIONATSUBSETSHEET SUBSETSHEET M1WTCHLINEIN�ICATOR: REFERENCESHEETLOCATIONFORA��ITIONAL REVISIONINDICATOR'. REFERENCETITLEBLOCNLOCATIONFOR INFORMATION. ADDITIONAL INFORMATION. FLOORPLANOVERIAP BEVON�AREA EMENSION � REVISION IN�ICATOR x SEE P 102 REFERTOADDITIONAL p�qry snEET FOR coNnNunnoN � RevisioN aouo EOUIPMENTIN�ICATOR: REFERENCESCHE�ULELOCATIONFORA��RIONAL INFORMATION. TLL%L kk — NUMERIC CHARACTER RELATES TO REM \ALPHANUMERIC CHARACTER RELATES TO BUIL�ING LEVEL (OPTIONAL) ALPHANUMERIC CHARACTER RELATES TO ASSOCWTED AIR HANDLER (OPTIONAL) EQUIPMENTTYPE GENERALNOTES A. ALLWORKSHALLBEINACCOR�ANCEWITHTHEBESTOUALRVSTAN�AR�S OF THE TRADE AND SHALL CONFORM WITH ALL FE�ERAL STATE. AND LOCAL CODES ANO STANDARDS. THE SAME ARE MADE A PART OF THESE CONTRACT�OCUMENTSASIFREPEATE�HEREIN. B. CONTRACTDOCUMENTSCONSISTOFBOTHTHEPROJECTMANUALAND DRAWINGS, AND BOTH ARE IMENDED TO BE COMPLEMENTARV. ANYiHING APPEARING ON EITHER MUST BE EXECOTED iHE SAME AS IF SHOWN ON BOTH C. THECONTRACTORSHALLINCLU�EINBI�PROPOSALALLCOSTSREQUIRED TO WMPLETELV AND PROPERLV INSTALL ALL WORN REpUIRE� FOR THE PROJECT. AND SHALL EXAMINE THE SCOPE OF WORK OF OTHER TRADES PRIOR TO SUBMITTING A BID PROPOSAL. �. CONSTROCTION�OCOMENTSSHALLBEFOLLOWEDASCLOSELYAS POSSIBLE HOWEVER, SVSTEMS HAVE BEEN SHOWN �IAGRAA1ATICALLV AND IN SOME CASES ENLARGED FOR CLARIiV. ANY OFFSETS. AO�ITIONAL FlTTINGS, AN�iOR APPl1RTENANCES REOUIRE� TO PROVI�E A C0�4PLETE AN� COORDINATE� SVSTEM SHALL BE BORNE BV THE COMRACTOR. E THEENGWEERING�RAWINGSAREOFEDUALIMPORTANCEWITHTHE ARCHITECTURAL DRAN/1NGS IN DEFlNING THE WORN OF THE WNTRACT �OCUMENTS. IT SHALL 8E iHE RESPONSI&LITV OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALU+TION OF ENGWEERING WORN. SHOULD THERE BE A DISCREPANCV BETWEEN THE ARCHITECTURAL DRAWINGS AN� iHE ENGINEERWG DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION. THE �ISCREPANCV SHALL BE BROUGHT TO THE ARCHITECTS/ENGINEERS ATTENTION FOR CLARIFlCATION PRIOR TO INSTALLATION OF SAI� WORK. ANV WORK INSTALLED IN CONFIICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTE� 9Y THE CONTRACTOR AT HIS EXPENSE AND AT NO A��ITIONAL COST TO THE OWNER OR ARCHITECT,'ENGINEER. F DONOTSCALETHEORAWINGS.THEORAWINGSARENOTNECESSARILYTO SCALE THE W NTRACTOR SHALL VERIFV ALL CONDITIONS AND �IMENSIONS AT THE JOB SRE PRIOR TO THE START OF CONSTROCTION. IF �ISCREPANCIES ARE FOIIND, THE ARCHITECTIENGINEER SHALL BE NOTIFIE� FOR CLARIFlCATION BEFORE W MMENQNG THE WORK EXPLICIT �IMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. G. DETAILSNOTSHOWNARESIMILARINCHARACTERTOTHOSESHOWN. WHERE SPECIFlC DIMENSIONS, DETAILS OR �ESIGN IMENT CANNOT BE �ETERMINE�, CONSULT THE ARCHITECTIENGINEER BEFORE PROCEE�ING WITH THE WORK. H. ANVDETAILS,SVSTEMSANDIORMATERIALSWHICHAREPROPOSEDT09E CHANGED MUST FIRST BE REVIEWE� BY THE OWNER AN� ARCHITECTIENGINEER PRIOR TO THE PREPARATION OF SHOP �RAWINGS. I. ALLCONFLICTS,WHICHMAYPREVENTTHECOMPLETIONOFWORKAS INTENDE�, SHALL BE BROUGHT TO THE ARCHITECT'S ATfENTION. THE CONTRACTOR SHALL NOT PROCEE� WITH ANV RELATE� WORK UNTIL ALL CONFLICTS ARE RESOLVEO AND THE CLARIFYING MFORMATION IS ISSUE� TO THE CONTRACTOR BV THE ARCHITECT. J. PROVI�E�FPAAPPROVEDFIRESTOPPINGWHEREPIPESPENETRATEFlRE anTeo F�ooas nNo wnus. K FlEL�VERIFlCATI�N'. CONTRACTORSHALLINSPECTAN�VERIFYALL EXISTING FlELD CONDITI�NS, 0.FARANCES AND �IMENSIONS BEFORE STARTINGCONSTRUCTION. COMMENCEMENTOFWORKCONSTITUTES ACCEPTANCEOFEXISTMGC�N�ITIONS. SHOULD�IFFERENTCONORI�NS BE ENCOIINTERE�, COMACT ARCHITECTIENGMEER BEFORE PROCEE�ING W ITH ANV WORK. NOTATION DESIGNATORS GENERALNOTES: NOTESiHATAPPLVE�UALLVTOALLDISCIPLINES WIiHIN THE �RAWING SET. GENERAL NOTESTHATAPPLVE�UALLVTOALLSHEETSWITHIN PWMBINGNOTES: THE�ISCIPLINE. GENERALSHEET NOTESTHATAPPLVONLVTOTHESPECIFlCSHEET NOTES�. ON WHICH THEY APPEAR. SHEETKEYNOTES. NOTESTHATAPPLVONLYTOTHESPEQFICSHEET ON WHICH THEV APPEAR AND USE A KEYNOTE INDICATOR TO I�ENTIFY ITEMS. U W � O�/ LL � V/ 2` i O` i � J �^ �..L Q` / Q � V/ Z O i a / W �/�/� ��• ��• Q � N O/y� ��• G V/ V/ � O � Q Z V v/ � V/ W � O J J a i Z CORNERSTONE � �■ � A��.-� c�N �■ STRUCTUREPOINT N� � CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 �t.�iii u,ri�! ��`��U� .�OGfi', o � P. �tiG�sr�n�;. 0 ''c c�f .� S�. �' Q� O� Zi � ��J: �•.P �tD � - —+� No.11300632 ';-G = M �,=o: n;o N - • ��, $TATE dF �� � � N lC7 = -d ". : Q. : �k � � g �'� �bDIANP,•�.-�c�, ;. � Q ,, F'FS N��� ; � NALE ' � ♦ ��li� �f'V���� � CERTIFIED BY ISSUANCE INDEX DATE: �5.22.202� PROJECT PHASE: CONSTRUCTION DOCUMENTS SYMBOLS AND ABBREVIATIONS P-000 Project Number 2019.01176