Loading...
HomeMy WebLinkAboutS524- TYPICAL STEEL CONNECTIONS% SUPPOFTFACE 4 aP a a HSS BEAM PER PLAN r� x IO � � � � � � 5B 1p ii O 5181� TVP — SUPPORTFACE �a 50 K51 END PL (MATCH � SHEARPLTHICKNESS) � HSS BEAM PER PLAN 5/8�p 5B ip TYP � 7/1 60KSIENDPL(MATCH "�' � SHEARPLTHICKNES3) SECTIONA(TOPVIEW) � DOUBLE SHEAR PL PEF CONNECTION ENGINEER NOTES: 1. EACH SHEAR PL SHALL BE DESIGNED AS AN HSS BEAM TO SUPPORT �SIDE) EXTENDED SHEAR PL WITH FULL ECCENTRICITV 2 AT CONTRACTOR'S OPTION, END PL MAV BE ExTENDED ON ALL SIDES AND WELDED TO TO H55 BEAM ALL AROUND W ITH SB �p RLLET W ELD TYPICAL HSS BEAM SHEAR PLATE CONNECTION ,. _ „o.. a r BEAM PER y PLAN.TYP - o0 i ' OO OO _ a � � 'i OO OO 5/e t� K N p i O O Sl8tp i O O — O O J SHEAR PLATE PER CONNECTION ENGINEER MIN 1/2" SMOOTH RAD W 5, TYP BEAM TO W GIRDER (SIDE) EXTENDED SHEAR PLATE (FITTED) - BEAM TO GIRDER I� NEARSIDEFLANGECUT ✓I AWAVFORCLARITY C� 3"TVP a L L%L�e" � BEAM PER PLAN 'I O — � V V 0 0 0 0 0 0 0 0 _ � a a EXTENDED SHEAR PLATE PER CONNECTION ENGINEER STABILIZER PL (TOP AND BOT) ATFLANGE, TVP 3 SI�ES, 5l8 b � TVP 5l8 y EXTENDED SHEAR PLATE PER CONNECTION ENGINEER BEAM TO W COLUMN WEB (SIDEI EXTENDED SHEAR PLATE - BEAM TO COLUMN WEB MINIMUM NUMBER OF BOLTS REQUIRED FOR SHEAR CONNECTIONS BEAM DEPTH REQUIRED # OF ROWS wa-wiz z W14-W18 3 W21-W24 4 W2�-W30 5 W33-W40 6 W44 7 NOTES: 1. IN ALL CASES THE CONNECTION LENGTH PROVIDED MUST BE GREATER THAN OR EQUAL TO 1/2 x T MINIMUM # OF BOLTS REFERENCE TABLE STA&LIZER PL (TOP AND BOT) . SECTION A a � m � 5116 5� THETA LESS THAN 45 DEG � a = � ---- p 1/4 BTC-P4 51(E)45� MODIFlED Z Q � � x V N � NEARSIDE RANGE CUT AWAV FOR CLARITV ' �3" TYP a L/ L/i. Lm � gEAM PER PLAN FITTED EXTENDED SHEAR PLA PER CONNECTION ENGINEER MIN V2' SMOOTH RADWS, TYP STABILIZER PL (TOP AND BOT) � � a0 � a0 � a0 � BEAM TO W COLUMN WEB f51DE1 EXTENDED SHEAR PLATEI N.T.S. SKEWED PLATE WELDS PL5/16 AND PL3/8 THETA(DEG) Si NOTES c 1] DEG 3/8" - 1]�THETA<=30 12" - 30<THETA<45 51i6" BEVELPLATE = 45 =tp E =tp - 1/B" > 45 CJP THETAEQUALT045DEG NOTES: 1. CJP WELDS MAY BE PROVIOED IN LIEU OF FlLLET WELDS. 5/16" AND 3/8" SKEWED SHEAR PLATE AT RANGE, TVP 3 SIDES, `'� T�P 5/8 �p FITTED EXTENDED SHEAR PLATE PER CONNECTION ENGINEER SECTION A - BEAM TO COLUMN WEB STABILIZER PL (TOP AND BOT) oVIH f � a = � 5/i6 5, THETA LESS THAN 45 DEG � a � m D 5116 BTC-P4 51(E)45� MODIFlED THETA EQUAL TO 45 DEG SKEWED PLATE WELDS PL1/2 THETA(DEG) S� NOTES <=1�DEG il2" - 1�<THETA<=22 9/i6" - 22<THETA <45 1l2" BEVELPLATE = 45 =�p E =�p- 1/8" > 45 CJP NOTES: 1. CJP WELDS MAV BE PROVIDED IN LIEU OF RLLET WELDS. 1/2" SKEWED SHEAR PLATE CCORNERSTONE ■� � � �M�R CR\ ■ STRUCTUREPOINT nc ■ o CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 .�, .r m: No. q�11200647 9� STFTE Of / i a 0 TVP (TVP) TYPICAL STEEL BEAM MOMENT CONNECTION AT UNEQUAL DEPTH GIRDER �� � �. RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel '�v�:���\i 1�.rvalMa=� . DATE: O$�Z4�ZO SEE PLANS FOR REQD �ESIGN SHEAR � � Q � � � O TVP � BACKING BAR (TYP) TYPICAL STEEL BEAM MOMENT CONNECTION AT EQUAL DEPTH GIRDER ��.�.�. 3 SIDES; TVP AT BEAM PER PLAN �TVP PER PLAN `r FULL-0EPTH STIFFENER � � `BEAM PER PLAN NS ANO FS THICKNE55 AS RE�UIRED BV SHEAR TAB CONNECTION DESIGN NOTE'. STIFFENER PLATES SHALL BE COLUMN PER PLAN ASTM A5I2 GRADE 50. TYPICAL BEAM MOMENT CONNECTION TO COLUMN FLANGE �� � �. BOTH FLGS TVP 3 SIDES, TVP 3 SIDES, TYP � � 0 � � � TVP SEE PLAN FOR REQD DESIGN SHEAR NOTE: STIFFENER PLATES SHALL ��gACKING BAR, TVP BE ASTM A5]2 GRADE 50. FULL W IDTH OF COLUMN W EB, TYP. THICKNESS AS REQUIRED BY DESIGN TYPICAL BEAM MOMENT CONNECTION \ TO COLUMN WEB ��.�.�. �OSI�� CERTIFIED BY ISSUANCE INDEX DATE: 05.22.2020 PROJECT PHASE: CONSTRUCTION DOCUMENTS S 524 PLAN,TVP SECTION A Project Number 2019.00780 TYPICAL STEEL CONNECTIONS