HomeMy WebLinkAboutIGA495 S100.1 First Floor Structual PlanLATERAL BRACING & SHEAR WALL SHEATHING SPECIFICATIONS THIS MODEL HAS BEEN DESIGNED TO RESIST LATERAL FORCES RESULTING FROM: 115 MPH WIND IN 2020 InRC MAP (115 MPH WIND SPEED IN ASCE 7-16 WIND MAP, PER IRC R301.2.1.1) EXP. B, RISK CAT. 2 & SEISMIC CAT. A/B. THE DESIGN WAS COMPLETED PER 2018 IBC (SECTION 1609) & ASCE 7-16, AS PERMITTED BY R301.1.3 OF THE 2020 InRC, OR THE SIMPLIFIED PRESCRIPTIVE PROCEDURE IN ACCORDANCE WITH THE 2020 InRC IF THE PARAMETERS OF SECTION R602.12 COMPLY. ACCORDINGLY, THIS MODEL, AS DOCUMENTED AND DETAILED HEREWITHIN, IS ADEQUATE TO RESIST THE CODE REQUIRED LATERAL FORCES. SEE CONNECTION SPECIFICATIONS CHART FOR STANDARD SHEAR TRANSFER DETAILING. IF ADDITIONAL CAPACITY IS REQUIRED BY DESIGN, IT WILL BE SPECIFICALLY NOTED ON PLAN. ALL STRUCTURAL PANELS ARE TO BE DIRECTLY APPLIED TO STUD FRAMING. NOTES M&K STND. - OCT. 2015 PRE-MANUFACTURED PANELIZED WALLS: FASTEN TOGETHER END STUDS OF WALL PANELS SHEATHED w/ OSB OR PLYWOOD w/ 10d NAILS @ 4" O.C. (THRU ONE SIDE ONLY) 3" O.C. EDGE NAILING 7/16" OSB OR 15/32" PLYWOOD: FASTEN SHEATHING w/ 2-3/8"x0.113 NAILS @ 6" O.C. AT EDGES & @ 12" O.C. IN THE PANEL FIELD. (TYP, U.N.O.) ALL SHEATHING PANELS SHALL BE ORIENTED VERTICALLY (LONG DIRECTION PARALLEL TO STUDS) AND INSTALLED FULL HEIGHT OF SHEAR WALL - OR - 2x HORIZONTAL BLOCKING SHALL BE PROVIDED TO SUPPORT ALL UNSUPPORTED PANEL EDGES & EDGE FASTENING. EXT. WALL SHEATHING SPECIFICATION ALL EXT. WALLS SHALL BE CONTINUOUSLY SHEATHED AND ARE CONSIDERED SHEAR WALLS. ALT. STAPLE CONNECTION SPEC: 1-3/4" 16 GA STAPLES (7/16" CROWN) @ 3" O.C. AT EDGES & @ 6" O.C IN FIELD. AT DESIGNATED AREAS - FASTEN PANEL EDGES OF WOOD STRUCTURAL WALL SHEATHING TO FRAMING w/ 2-3/8"x0.113" NAILS @ 3" o.c. AND 12" o.c. IN THE PANEL FIELD. NO STAPLE ALTERNATIVE AVAILABLE AT THIS SPEC. ALL SHEATHING PANELS SHALL BE ORIENTED VERTICALLY (LONG DIRECTION PARALLEL TO STUD) AND INSTALLED FULL HEIGHT OF SHEAR WALL - OR - 2x HORIZONTAL BLOCKING SHALL BE PROVIDED TO SUPPORT UNSUPPORTED PANEL EDGES AND 3" O.C. EDGE FASTENING. DESIGN ASSUMES 16" O.C MAX. STUD SPACING, U.N.O. INDICATES HOLDOWN INDICATES EXTENT OF INT. OSB SHEARWALL AND/OR 3" O.C. EDGE NAILING INDICATES POST ABOVE (P.A.) PROVIDE SOLID BLOCKING UNDER POST OR JAMB ABOVE. ã SOLE PLATE TO JOIST/BLK'G. DOUBLE STUD DOUBLE TOP PLATE DOUBLE TOP PLATE LAP SPLICE JOIST TO SOLE PLATE (3)10d TOENAILS GAB. END TRUSS TO DBL. TOP PL. 10d TOENAILS @ 8" o.c. 10d NAILS @ 6" o.c. STUD TO SOLE PLATE BLK'G. BTWN. JOISTS TO TOP PL. RIM TO TOP PLATE TOP OR SOLE PLATE TO STUD (3)10d TOENAILS (3)10d TOENAILS 10d TOENAILS @ 6" o.c. (3)10d NAILS RAFTER/TRUSS TO TOP PLATE (3)10d TOENAILS + (1) SIMPSON H2.5A R.T. w/ HEEL HT. 9 14" TO 12"2x10 BLK EVERY 3RD BAY FASTENED TO DBL. TOP PLATE w/ 10d TOENAILS @ 6" O.C. R.T. w/ HEEL HT. 12" TO 16" R.T. w/ HEEL HT. UP TO 24" R.T. w/ HEEL HT. 24" TO 48" 2x12 BLK EVERY 3RD BAY FASTENED TO DBL. TOP PLATE w/ 10d TOENAILS @ 6" O.C. LAP WALL SHTG. w/ DBL. TOP PL. & INSTALL ON TRUSS VERT. - FASTEN w/ 8d NAILS @ 6" O.C. LAP WALL SHTG. w/ DBL. TOP PL. & INSTALL ON TRUSS VERT. - FASTEN w/ 8d NAILS @ 6" O.C. PROVIDE 2x BLK @ EA. BAY AT 10d NAILS @ 24" o.c. 10d NAILS @ 24" o.c. (10)10d NAILS IN LAPPED AREA WALL TO FOUNDATION WALL SHTG. LAP w/ SILL PL. & FASTENED PER SHEAR WALL CONNECTION SPECIFICATIONS (TYP. U.N.O.) NOTE: 10d NAIL = 3" x 0.131" GUN NAIL FASTENING SPEC. TOP PLATE LAP @ CORNERS & INTERSECTING WALLS (2)10d NAILS TOP OF HEEL COLUMN TOP PLATE BOLTED TO BEAM WITH AT LEAST (4) 12" DIAMETER BOLTS BOTTOM FLANGE OF STEEL BEAM FASTENED TO SUPPORTING WOOD FRAMING w/ (2) 12" DIA. X 3 12" LONG LAG SCREWS. CLIP ANGLES EITHER WELDED TO THE BEAM ALONG EACH CLIP ANGLE'S ENTIRE LENGTH OR BOLTED TO THE BEAM USING A MINIMUM OF 12" DIAMETER BOLTS. CLIP ANGLE ATTACHED TO THE FOUNDATION WALL USING NO LESS THAN (1) 12" DIAMETER ANCHOR OR (2) 1 4" DIA. x 214" LONG TAPCON SCREWS. BEAM POCKET GROUTED SOLID AROUND STEEL BEAM STEEL BM SUPPORTED ON WOOD FRAME STEEL BEAM IN BEAM POCKET ANCHORED TO CONCRETE FOOTING PAD WITH (2) 12" DIAMETER CONC. ANCHORS THROUGH THE STEEL BASE PLATE TO THE CONCRETE FOUNDATION. ANCHORED TO CONCRETE FOOTING PAD WITH (4) 12" DIAMETER CONC. ANCHORS THROUGH THE STEEL BASE PLATE TO THE CONCRETE FOUNDATION. ENCASED IN CONCRETE SLAB STEEL CONNECTIONS CHART CONNECTION SPECIFICATION CAP COLUMN TOP PLATE EITHER WELDED ALONG THE TWO SIDES PERPENDICULAR TO THE BEAM'S LENGTH OR BOLTED WITH (2) 1#2" DIAMETER BOLTS PLACED DIAGONALLY THROUGH THE TOP PLATE CONNECTION TYPE TO STL. COLUMN (INTERIOR CONDITION) BASE OR TO STL. COLUMN (END CONDITION) CAP BASE ENCASED IN CONCRETE SLAB OR OR 09/17/20