Loading...
HomeMy WebLinkAboutG001EARTH NOTE: PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERWISE.GRANULAR FILL CONCRETE, CAST-IN-PLACE CONCRETE, PRECAST/CAST STONE CONCRETE MASONRY UNIT BRICK MASONRY STONE: LIMESTONE, GRANITE, MARBLE OR AS NOTED METAL: TYPE AS NOTED METAL: ROLLED SHAPES WOOD FRAMING / BLOCKING: CONTINOUS WOOD SHIM WOOD/FINISHED, SHOWN CUT AND ELEVATION PLYWOOD PARTICLEBOARD EIFS SPRAYED FIREPROOFING SHOWN ON ROLLED SHAPE BATT INSULATION: THERMAL OR ACOUSTICAL, UNO RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING SHEATHING: GYPSUM, OR AS NOTED GYPSUM WALL BOARD TILE: CERAMIC, QUARRY, UNO RESINOUS FLOORING: TERRAZO, TROWEL-ON, UNO ACOUSTICAL CEILING TILE GRATING (PLAN) INSULATED GLASS: (SMALL SCALE) GRATING (SECTION) MEMBRANE: WATERPROOF, ROOF, DAMPPROOFING AIR BARRIER SYSTEM INSULATED GLASS: (DETAIL) TERRA COTTA, STRUCTURAL CLAY TILE CARPET, CARPET TILE (DETAIL) SAND, GROUT AS NOTED GLASS FIBER REINFORCED CONCRETE SIDING OR TRIM WOOD/ENGINEERED: GLUE LAMINATED PLASTER ON METAL LATH WOOD FLOOR, WOOD SHINGLES, OR SIDING ENLARGED DRAWING REFERENCE ELEVATION DATUM REFERENCE NORTH ARROW DRAWING NUMBER SHEET NUMBER BUILDING SECTION CUT REFERENCE SF27 101 A101 1 SIM 1 1 EW26 N 1 KEYED NOTE REVISION REFERENCE WINDOW TAG DOOR TAG ROOM NAME AND NUMBER COLUMN GRID NEW A DRAWING NUMBER SHEET NUMBER WALL SECTION CUT REFERENCE DRAWING NUMBER SHEET NUMBER EXTERIOR ELEVATION REFERENCE WALL TYPE REFERENCE (REFERENCE INTERIOR PARTITION LEGEND) COLUMN GRID EXISTING 1 EQUIPMENT TAG X XX X XX 1 Ref XX Room 101 A. SEE THIS SHEET FOR GRAPHIC SYMBOL LEGEND. B. SEE SHEET G111 FOR GENERAL PARTITION NOTES. C. SEE A700 SHEETS FOR GENERAL FINISH NOTES FOR EACH TENANT. D. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION. E. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FINISHED FACE OF EXISTING WALL SURFACE, OR FACE OF CONCRETE / MASONRY UNITS UNLESS NOTED OTHERWISE. F. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR SHALL FURNISH ALL NECESSARY PERMITS. G. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS (DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THEIR WORK. ALL WORK SHALL BE COMPLETE IN EVERY DETAIL AND THE CONTRACTORS SHALL PROVIDE A ONE YEAR WARRANTY FOR THEIR WORK. H. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS WASTE LAWS, ETC. I. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT LOCATION. BRING ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION IN WRITING IMMEDIATELY. J. BUILDING FIRST FLOOR IS REFERENCE ELEVATION 100'-0". K. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND MANNER ACCEPTABLE TO THE ARCHITECT AND OWNER. L. CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS. M. CAULK TOILET FIXTURES AND COUNTERTOP SPLASHES TO FINISH SURFACE IN ACCORDANCE WITH SEALANT SCHEDULE IN SPECIFICATIONS. N. EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR BEGINNING OF WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IN WRITING IMMEDIATELY. O. COVER ALL RETURN AIR GRILLES AND EXHAUST GRILLES IN CONSTRUCTION AREA WITH MIN. MERV 13 FILTER MEDIA, CHANGED REGULARLY. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/16/2020 2:34:11 PMG001 SHEET INDEX 2019.01176 07/14/2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION - FIRST FLOOR TENANT BUILD-OUTS 12174 N. Meridian Street Carmel, Indiana 46032 ORIG ORIGINAL P PERM PERMANENT PH PHASE PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTIC PNL PANEL PREFAB PREFABRICATED PREFIN PREFINISHED PRELIM PRELIMINARY PREP PREPARATION PROJ PROJECT PT PRESERVATIVE TREATED PTD PAINTED PTN PARTITION Q QT QUARRY TILE R R RADIUS RD ROOF DRAIN REC RECESSED RECPT RECEPTACLE REF REFER(ENCE) REINF REINFORCE(D)(ING)(M ENT) REQD REQUIRED RESIL RESILIENT RM ROOM RO ROUGH OPENING RTU ROOF TOP UNOT S SAN SANITARY SCW SOLID CORE WOOD SF SQUARE FOOT SPKLR SPRINKLER SS STAINLESS STEEL STD STANDARD STL STEEL STOR or ST STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SYM SYMBOL SYS SYSTEM T T&G TONGUE AND GROOVE T/ TOP OF TEL TELEPHONE TEMP TEMPORARY THRES THRESHOLD TOT TOTAL TYP TYPICAL U UNIF UNIFORM UNO UNLESS NOTED OTHERWISE UR URINAL V VB VINYL BASE VCT VINYL COMPOSITION TILE VERT VERTICAL VIN VINYL VT VINYL TILE VWC VINYL WALL COVERING W W/W WALL TO WALL WC WATER CLOSET WD WOOD WDW WINDOW WH WALL HUNG WT WEIGHT G GALV GALVANIZED GLZ GLAZING GUT GUTTER GYP BD/GWB GYPSUM BOARD H HC HANDICAP(PED) HCW HOLLOW CORE WOOD HDWE/HDW HARDWARE HM HOLLOW METAL HMD HOLLOW METAL DOOR HORIZ HORIZONTAL HT HEIGHT HVAC HEATING, VENTILATION, AIR CONDITIONING I ICF INSULATED CONCRETE FORM ID INSIDE DIAMETER IF INSIDE FACE INCAND INCANDESCENT INDIC INDICATE INSTL INSTALL(ATION) INSUL INSULATION INT INTERIOR J JST JOIST JT JOINT L LAV LAVATORY LD BRG LOAD BEARING LF LINEAR FOOT LTG LIGHTING LTWT LIGHTWEIGHT LVR LOUVER M MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDICINE (MEDICAL) MET METAL MFG MANUFACTURER (ING) MIN MINIMUM MISC MISCELLANEOUS MLWK MILLWORK MO MASONRY OPENING MTD MOUNTED MTG MOUNTING MULL MULLION MULT MULTIPLE N N/A NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE O O/O OUT TO OUT OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFCI OWNER FURNISHED - CONTRACTOR INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPT OPTIONAL ORD OVERFLOW ROOF DRAIN A A/E ARCHITECT/ENGINEER ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE ADA AMERICAN'S WITH DISABILITIES ACT ADD ADDENDUM ADJ ADJACENT AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED ARCH ARCHITECT (URAL) B BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BOT BOTTOM BRG BEARING C C/C CENTER TO CENTER CAB CABINET CB CORNER BEAD CER CERAMIC CF CUBIC FOOT CFCI CONTRACTOR FURNISHED / CONTRACTOR INSTALLED CHAN CHANNEL CJ CONTROL JOINT CL CENTER LINE CLG CEILING CMU CONCRETE MASONRY UNIT CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS CP/CPT CARPET D DEMO DEMOLITION (ISH) DF DRINKING FOUNTAIN DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DO DOOR OPENING DS DOWNSPOUT DWG DRAWING E EJ EXPANSION JOINT ELEC ELECTRICAL (ELEVATOR) ELEV ELEVATION ENCL ENCLOSURE ENGR ENGINEER EQUIP EQUIPMENT EWC ELECTRICAL WATER COOLER EXST EXISTING F F/F FACE TO FACE FDN FOUNDATION FE FIRE EXTINGUISHER FHC FIRE HOSE CABINET FIN FINISH FIN FL FINISHED FLOOR FLR (FLRG) FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RATING FT FIRE TREATED FTG FOOTING FURN FURNITURE FURR FURRING ABBREVIATIONS SHEET INDEX SHEET NUMBER SHEET NAME GENERAL G000 COVER SHEET G001 SHEET INDEX G101 FIRST FLOOR LIFE SAFETY PLAN - TENANT 1 G102 FIRST FLOOR LIFE SAFETY PLAN - TENANT 2 G111 WALL TYPES ARCHITECTURAL T1-A101 DIMENSION PLAN T1-A102 ARCHITECTURAL FLOOR PLAN T1-A121 REFLECTED CEILING PLAN T1-A401 ENLARGED PLANS AND ELEVATIONS T1-A402 ENLARGED PLANS AND ELEVATIONS T1-A430 INTERIOR ELEVATIONS T1-A521 SECTION DETAILS T1-A601 DOOR SCHEDULES T1-A602 DOOR, STOREFRONT, & WINDOW DETAILS T1-A701 INTERIOR FINISH PLAN T1-A801 FIRST FLOOR EQUIPMENT PLAN T2-A101 FIRST FLOOR DIMENSION & ARCHITECTURAL PLANS T2-A121 FIRST FLOOR REFLECTED CEILING PLAN T2-A401 ENLARGED PLANS AND ELEVATIONS T2-A430 INTERIOR ELEVATIONS T2-A521 SECTION DETAILS T2-A601 DOOR SCHEDULES T2-A701 FIRST FLOOR FINISH PLAN T2-A801 FIRST FLOOR EQUIPMENT PLAN MECHANICAL M000 SYMBOLS AND ABBREVIATIONS M101 FIRST FLOOR MECHANICAL DUCTWORK PLAN M501 MECHANICAL DETAILS M602 MECHANICAL SCHEDULES PLUMBING P000 SYMBOLS AND ABBREVIATIONS P101 FIRST FLOOR PLUMBING PLAN P602 PLUMBING SCHEDULES & DETAILS ELECTRICAL E001 ELECTRICAL SYMBOLS E201.11 FIRST FLOOR LIGHTING PLAN - TENANT 1 E201.12 FIRST FLOOR LIGHTING PLAN - TENANT 2 E301.11 FIRST FLOOR POWER & SYSTEMS PLAN - TENANT 1 E301.12 FIRST FLOOR POWER & SYSTEMS PLAN - TENANT 2 E501 ELECTRICAL ONE LINE RISER DIAGRAM E601 ELECTRICAL SCHEDULES E602 ELECTRICAL SCHEDULES E603 ELECTRICAL SCHEDULES E604 ELECTRICAL SCHEDULES E701 ELECTRICAL SCHEMATICS E801 ELECTRICAL DETAILS MATERIALS LEGEND GRAPHIC LEGEND GENERAL NOTES REVISION SCHEDULE NO. DESCRIPTION DATE 09/17/20