HomeMy WebLinkAboutG001EARTH
NOTE: PATTERNS SHOWN REPRESENT CUT
MATERIALS IN PLAN OR SECTION, UNLESS NOTED
OTHERWISE.GRANULAR FILL
CONCRETE, CAST-IN-PLACE
CONCRETE, PRECAST/CAST
STONE
CONCRETE MASONRY UNIT
BRICK MASONRY
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES
WOOD FRAMING / BLOCKING:
CONTINOUS
WOOD SHIM
WOOD/FINISHED,
SHOWN CUT AND ELEVATION
PLYWOOD
PARTICLEBOARD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL OR
ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
SHEATHING: GYPSUM, OR AS
NOTED
GYPSUM WALL BOARD
TILE: CERAMIC, QUARRY, UNO
RESINOUS FLOORING: TERRAZO,
TROWEL-ON, UNO
ACOUSTICAL CEILING TILE
GRATING (PLAN)
INSULATED GLASS:
(SMALL SCALE)
GRATING (SECTION)
MEMBRANE: WATERPROOF,
ROOF, DAMPPROOFING
AIR BARRIER SYSTEM
INSULATED GLASS:
(DETAIL)
TERRA COTTA, STRUCTURAL CLAY
TILE
CARPET, CARPET TILE (DETAIL)
SAND, GROUT
AS NOTED
GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
WOOD/ENGINEERED: GLUE
LAMINATED
PLASTER ON METAL LATH
WOOD FLOOR, WOOD SHINGLES,
OR SIDING
ENLARGED DRAWING REFERENCE
ELEVATION DATUM REFERENCE
NORTH ARROW
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION CUT REFERENCE
SF27
101
A101
1
SIM
1
1
EW26
N
1
KEYED NOTE
REVISION REFERENCE
WINDOW TAG
DOOR TAG
ROOM NAME AND NUMBER
COLUMN GRID NEW
A
DRAWING NUMBER
SHEET NUMBER
WALL SECTION CUT REFERENCE
DRAWING NUMBER
SHEET NUMBER
EXTERIOR ELEVATION REFERENCE
WALL TYPE REFERENCE (REFERENCE
INTERIOR PARTITION LEGEND)
COLUMN GRID EXISTING
1 EQUIPMENT TAG
X
XX
X
XX
1 Ref
XX
Room
101
A. SEE THIS SHEET FOR GRAPHIC SYMBOL LEGEND.
B. SEE SHEET G111 FOR GENERAL PARTITION NOTES.
C. SEE A700 SHEETS FOR GENERAL FINISH NOTES FOR EACH TENANT.
D. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
E. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FINISHED FACE OF
EXISTING WALL SURFACE, OR FACE OF CONCRETE / MASONRY UNITS UNLESS NOTED
OTHERWISE.
F. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE
RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND
SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS,
SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR SHALL
FURNISH ALL NECESSARY PERMITS.
G. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF
THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS
(DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE
PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE
BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL,
MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT
INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED
FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE
CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS,
THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THEIR WORK. ALL WORK SHALL BE COMPLETE IN
EVERY DETAIL AND THE CONTRACTORS SHALL PROVIDE A ONE YEAR WARRANTY FOR
THEIR WORK.
H. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES,
LAWS, SAFETY REGULATIONS AND HAZARDOUS WASTE LAWS, ETC.
I. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT
LOCATION. BRING ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION IN WRITING
IMMEDIATELY.
J. BUILDING FIRST FLOOR IS REFERENCE ELEVATION 100'-0".
K. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND MANNER
ACCEPTABLE TO THE ARCHITECT AND OWNER.
L. CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS.
M. CAULK TOILET FIXTURES AND COUNTERTOP SPLASHES TO FINISH SURFACE IN
ACCORDANCE WITH SEALANT SCHEDULE IN SPECIFICATIONS.
N. EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR BEGINNING OF
WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION IN WRITING IMMEDIATELY.
O. COVER ALL RETURN AIR GRILLES AND EXHAUST GRILLES IN CONSTRUCTION AREA WITH
MIN. MERV 13 FILTER MEDIA, CHANGED REGULARLY.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/16/2020 2:34:11 PMG001
SHEET INDEX
2019.01176
07/14/2020
CONSTRUCTION DOCUMENTS
CARMEL MEDICAL ARTS
PAVILION - FIRST FLOOR
TENANT BUILD-OUTS
12174 N. Meridian Street
Carmel, Indiana 46032
ORIG ORIGINAL
P
PERM PERMANENT
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PNL PANEL
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARATION
PROJ PROJECT
PT PRESERVATIVE
TREATED
PTD PAINTED
PTN PARTITION
Q
QT QUARRY TILE
R
R RADIUS
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFER(ENCE)
REINF REINFORCE(D)(ING)(M
ENT)
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNOT
S
SAN SANITARY
SCW SOLID CORE WOOD
SF SQUARE FOOT
SPKLR SPRINKLER
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR or ST STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMBOL
SYS SYSTEM
T
T&G TONGUE AND
GROOVE
T/ TOP OF
TEL TELEPHONE
TEMP TEMPORARY
THRES THRESHOLD
TOT TOTAL
TYP TYPICAL
U
UNIF UNIFORM
UNO UNLESS NOTED
OTHERWISE
UR URINAL
V
VB VINYL BASE
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIN VINYL
VT VINYL TILE
VWC VINYL WALL
COVERING
W
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WT WEIGHT
G
GALV GALVANIZED
GLZ GLAZING
GUT GUTTER
GYP BD/GWB GYPSUM BOARD
H
HC HANDICAP(PED)
HCW HOLLOW CORE WOOD
HDWE/HDW HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING,
VENTILATION, AIR
CONDITIONING
I
ICF INSULATED
CONCRETE FORM
ID INSIDE DIAMETER
IF INSIDE FACE
INCAND INCANDESCENT
INDIC INDICATE
INSTL INSTALL(ATION)
INSUL INSULATION
INT INTERIOR
J
JST JOIST
JT JOINT
L
LAV LAVATORY
LD BRG LOAD BEARING
LF LINEAR FOOT
LTG LIGHTING
LTWT LIGHTWEIGHT
LVR LOUVER
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDICINE (MEDICAL)
MET METAL
MFG MANUFACTURER (ING)
MIN MINIMUM
MISC MISCELLANEOUS
MLWK MILLWORK
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MULT MULTIPLE
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
O/O OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED -
CONTRACTOR
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
ORD OVERFLOW ROOF
DRAIN
A
A/E ARCHITECT/ENGINEER
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING
TILE
ADA AMERICAN'S WITH
DISABILITIES ACT
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT (URAL)
B
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
C
C/C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CER CERAMIC
CF CUBIC FOOT
CFCI CONTRACTOR
FURNISHED /
CONTRACTOR
INSTALLED
CHAN CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY
UNIT
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CP/CPT CARPET
D
DEMO DEMOLITION (ISH)
DF DRINKING FOUNTAIN
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DO DOOR OPENING
DS DOWNSPOUT
DWG DRAWING
E
EJ EXPANSION JOINT
ELEC ELECTRICAL
(ELEVATOR)
ELEV ELEVATION
ENCL ENCLOSURE
ENGR ENGINEER
EQUIP EQUIPMENT
EWC ELECTRICAL WATER
COOLER
EXST EXISTING
F
F/F FACE TO FACE
FDN FOUNDATION
FE FIRE EXTINGUISHER
FHC FIRE HOSE CABINET
FIN FINISH
FIN FL FINISHED FLOOR
FLR (FLRG) FLOOR(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATING
FT FIRE TREATED
FTG FOOTING
FURN FURNITURE
FURR FURRING
ABBREVIATIONS SHEET INDEX
SHEET NUMBER SHEET NAME
GENERAL
G000 COVER SHEET
G001 SHEET INDEX
G101 FIRST FLOOR LIFE SAFETY PLAN - TENANT 1
G102 FIRST FLOOR LIFE SAFETY PLAN - TENANT 2
G111 WALL TYPES
ARCHITECTURAL
T1-A101 DIMENSION PLAN
T1-A102 ARCHITECTURAL FLOOR PLAN
T1-A121 REFLECTED CEILING PLAN
T1-A401 ENLARGED PLANS AND ELEVATIONS
T1-A402 ENLARGED PLANS AND ELEVATIONS
T1-A430 INTERIOR ELEVATIONS
T1-A521 SECTION DETAILS
T1-A601 DOOR SCHEDULES
T1-A602 DOOR, STOREFRONT, & WINDOW DETAILS
T1-A701 INTERIOR FINISH PLAN
T1-A801 FIRST FLOOR EQUIPMENT PLAN
T2-A101 FIRST FLOOR DIMENSION & ARCHITECTURAL PLANS
T2-A121 FIRST FLOOR REFLECTED CEILING PLAN
T2-A401 ENLARGED PLANS AND ELEVATIONS
T2-A430 INTERIOR ELEVATIONS
T2-A521 SECTION DETAILS
T2-A601 DOOR SCHEDULES
T2-A701 FIRST FLOOR FINISH PLAN
T2-A801 FIRST FLOOR EQUIPMENT PLAN
MECHANICAL
M000 SYMBOLS AND ABBREVIATIONS
M101 FIRST FLOOR MECHANICAL DUCTWORK PLAN
M501 MECHANICAL DETAILS
M602 MECHANICAL SCHEDULES
PLUMBING
P000 SYMBOLS AND ABBREVIATIONS
P101 FIRST FLOOR PLUMBING PLAN
P602 PLUMBING SCHEDULES & DETAILS
ELECTRICAL
E001 ELECTRICAL SYMBOLS
E201.11 FIRST FLOOR LIGHTING PLAN - TENANT 1
E201.12 FIRST FLOOR LIGHTING PLAN - TENANT 2
E301.11 FIRST FLOOR POWER & SYSTEMS PLAN - TENANT 1
E301.12 FIRST FLOOR POWER & SYSTEMS PLAN - TENANT 2
E501 ELECTRICAL ONE LINE RISER DIAGRAM
E601 ELECTRICAL SCHEDULES
E602 ELECTRICAL SCHEDULES
E603 ELECTRICAL SCHEDULES
E604 ELECTRICAL SCHEDULES
E701 ELECTRICAL SCHEMATICS
E801 ELECTRICAL DETAILS
MATERIALS LEGEND GRAPHIC LEGEND
GENERAL NOTES
REVISION SCHEDULE
NO. DESCRIPTION DATE
09/17/20