HomeMy WebLinkAboutG102WD CODE LEGEND EXIT SEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER AND FIRE MARSHAL. FEC 1 HR FIRE RATED (FIRE BARRIER) NOTES: A. WHERE FIRE-RESISTANCE-RATED OR SMOKE-RESISTANCE-RATED WALLS EXTEND ABOVE A CEILING, SUCH WALLS SHALL BE PERMANENTLY AND APPROPRIATELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN THE BUILDING CODE - SECTION 703.3. PROJECT AREA AREA DENOTED AS REHAB EQUIPMENT AREA AND USING OCCUPANT LOAD 1:50 APPLICABLE BUILDING CODES 2014 Indiana Building Code; comprised of: -2012 International Building Code -675 IAC 13-2.6 2014 Indiana Fire Code; comprised of: -2012 International Fire Code -675 IAC 22-2.5 2012 Indiana Plumbing Code; comprised of: -2006 International Plumbing Code -675 IAC 16-1.4 2009 Indiana Electrical Code; comprised of: -2008 NFPA 70 -675 IAC 17-1.8 2014 Indiana Mechanical Code; comprised of: -2012 International Mechanical Code -675 IAC 18-1.6 ALLOWABLE HEIGHT AND AREA OCCUPANCY CLASSIFICATION B Occupancy CONSTRUCTION TYPE Type IIB SPRINKLER SYSTEM Equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1 LIFE SAFETY / BUILDING CODE SUMMARY TRAVEL DISTANCE RESTRICTIONS • Dead-end Corridor Limit: 50 ft • Common Path of Travel: 100 ft • Exit Travel Distance: 300 ft to exit access or exit 3 story; 55 ft 23,000 sf 3 story; 48'-6" ft 43,822 sf ACTUAL HEIGHT AND BUILDING AREA TABULAR VALUES: sprinkler: 1 story; 20 ftHEIGHT INCREASE: sprinkler: 200% of 23,000 = 46,000 sf frontage: 75% of 23,000 = 17,250 sf AREA INCREASE: height: 4 story; 75 ft area: 86,250 sf (per floor); 172,500 sf (building) TOTALS: BUILDING USE This facility will be used for professional offices. FIRE RESISTANCE RATING REQ'TS FOR BUILDING ELEMENTS Structural Frame 0 HR Bearing Walls Exterior 0 HR Interior 0 HR Non Bearing Walls Exterior 0 HR Interior 0 HR Floor Construction 0 HR Roof Construction 0 HR • Elevator shaft enclosure - 1 hour fire barrier (3002.1; 713.4) • Elevator Equipment Room - 1 hour fire barrier (including ceiling) (3006.4) • Stairs - 1 hour fire barrier (1009.3.1.2) • Ductwork chase: A shaft enclosure is required for penetrations by ducts protected in accordance with Section 713.4 (see also 717.6.3) • 714.4.2 Nonfire-resistance-rated assemblies. Penetrations of nonfire-resistance-rated floor or floor/ceiling assemblies or the ceiling membrane of a nonfire-resistance-rated roof/ceiling assembly shall meet the requirements of Section 713 or shall comply with Section 714.4.2.1 or 714.4.2.2 • 714.4.2.2 Penetrating items: Penetrating items that connect not more than two stories are permitted, provided that the annular space is filled with an approved material to resist the free passage of flame and the products of combustion. REQ'D SEPARATIONS PLUMBING FIXTURE CALCULATIONS 1st Floor - Team Rehab Tenant (Use Group B) 38 occupants (see above) WC/Urinal - 38 occ * 1/25 = 1.52 fixtures; 2 provided Lav - 38 occ * 1/40 = 0.95; 2 provided 2,898 sfACTUAL AREA OF PROJECT OCCUPANT LOAD B Occupancy = 1:100 REHAB EQUIPMENT AREA = 1:50 TOTAL OCCUPANTS B Occupancy Area: 1,998 sf / 100 = 20 Rehab Equipment Area: 900 / 50 = 18 OCCUPANTS Total Occupants = 38 CODE STRATEGY The following strategy is being used to approach the life safety code concerns for this building: The entire building will be designed as a B Occupancy building of Type IIB (noncombustible) construction. PATIENT RESTROOM 1209 VESTIBULE 1200 RECEPTION 1203WAITING 1201 REHAB 1206 LAUNDRY 1208 STAFF BREAK 1211 TREATMENT 1205 OFFICE 1212 TREATMENT 1204 STAFF RESTROOM 1210 PHYSICIAN WORK 1207 FEC 98 ft.DATA CLOS. 1213 STAIR ST2-1 JANITOR 109 ELEC 108 CORRIDOR 107 CORRIDOR 102 PUBLIC RESTROOM 104 PUBLIC RESTROOM 103 LOBBY 101 VESTIBULE 100 MECH/ SPRINKLER 105 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/16/2020 2:12:42 PMG102 FIRST FLOOR LIFE SAFETY PLAN 2019.01176 07/14/2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION - FIRST FLOOR TENANT BUILD-OUTS 12174 N. Meridian Street Carmel, Indiana 46032 N 1/8" = 1'-0"G102 1 FIRST FLOOR LIFE SAFETY PLAN - TEAM REHAB REVISION SCHEDULE NO. DESCRIPTION DATE 09/17/20