HomeMy WebLinkAboutG111A2
A3
A6
A1 A1S
WALL PARTITION TYPE 6"PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
A
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED - SEE SCHEDULE BELOW
METAL RUNNER
SEALANT; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL AND 5/8" TILE BACKER BOARD ON
PARTITIONS WITH WALL TILE.
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 - 7/8"
3 - 3/4"
4 - 7/8"
7 - 1/4"6"
3 - 5/8"
2 - 1/2"
1 - 5/8"
STC:
NO SOUND
WITH SOUND
A2S
A3S
A6S
A8
NON-
RATED NA 9 - 1/4"8"
A8S
LATERAL BRACING AT 4'-0" O.C. MAX.
49
49
49
49
B2
B3
B6
B1 B1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
B
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE
PROVIDE SOUND ATTENUATION INSULATION WHERE INDICATED - SEE SCHEDULE
BELOW
METAL RUNNER
SEALANT; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL AND 5/8" TILE BACKER BOARD ON
PARTITIONS WITH WALL TILE.
METAL RUNNER / DEFLECTION TRACK
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA 2 - 7/8"
3 - 3/4"
4 - 7/8"
7 - 1/4"6"
3 - 5/8"
2 - 1/2"
1 - 5/8"
STC:
NO SOUND
WITH SOUND
B2S
B3S
B6S
B8
9 - 1/4"8"
B8S
SEALANT; BOTH SIDES, CONT.
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA
NON-
RATED NA 49
49
49
49
C2
C3
C6
C1 C1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
ONE
HOUR
C
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE.
PROVIDE SOUND ATTENUATION INSULATION WHERE INDICATED - SEE SCHEDULE BELOW
METAL RUNNER
RATED SEALANT; BOTH SIDES, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL AND 5/8" TILE BACKER BOARD ON
PARTITIONS WITH TILE.
METAL RUNNER / DEFLECTION TRACK
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
UL Des
U419
or
U465
2 - 7/8"
3 - 3/4"
4 - 7/8"
7 - 1/4"6"
3 - 5/8"
2 - 1/2"
1 - 5/8"
STC:
NO SOUND
WITH SOUND
C2S
C3S
C6S
C8
9 - 1/4" 8"
C8S
ONE
HOUR
ONE
HOUR
ONE
HOUR
ONE
HOUR
RATED SEALANT; BOTH SIDES, CONT.
UL Des
U419
or
U465
UL Des
U419
or
U465
UL Des
U419
or
U465
UL Des
U419
or
U465
49
49
49
49
F2
F3
F6
F1 F1S
WALL PARTITION TYPE 6"PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
F
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE
PROVIDE SOUND ATTENUATION INSULATION WHERE INDICATED - SEE SCHEDULE
BELOW
METAL RUNNER
SEALANT; ONE SIDE, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL AND 5/8" TILE BACKER BOARD ON
PARTITIONS WITH WALL TILE.
METAL RUNNER
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 - 1/4"
3 - 1/8"
4 - 1/4"
6 - 5/8"6"
3 - 5/8"
2 - 1/2"
1 - 5/8"
STC:
NO SOUND
WITH SOUND
F2S
F3S
F6S
F8
NON-
RATED NA 8 - 5/8"8"
F8S
LATERAL BRACING AT 4'-0" O.C. MAX.
46
46
46
46
G2
G3
G6
G1 G1S
WALL PARTITION TYPE PLAN VIEW SECTION VIEWSECTION VIEW
REMARKS
NON-
RATED
NON-
RATED
NON-
RATED
REFER TO SCHEDULE BELOW FOR PARTITION WIDTH
NON-
RATED
G
METAL STUD FRAMING @ 16" O.C. MAX.
ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE
PROVIDE SOUND ATTENUATION INSULATION WHERE INDICATED - SEE SCHEDULE
BELOW
METAL RUNNER
SEALANT; ONE SIDE, CONT.
ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE
OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR
OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE
RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL
RESTROOMS AND JANITOR'S CLOSETS,TYPICAL AND 5/8" TILE BACKER BOARD ON
PARTITIONS WITH WALL TILE.
METAL RUNNER / DEFLECTION TRACK
LINE OF
STRUCTURE
UNDERSIDE OF
STRUCTURE
LINE OF
CEILING
STUD
WIDTH
PART.
WIDTH
FIRE
RATING
UL LISTING
WITH SOUND
ATTENUATION
DESIGNATION
NO SOUND
ATTENUATION
DESIGNATION
NA
NA
NA
NA
2 - 1/4"
3 - 1/8"
4 - 1/4"
6 - 5/8"6"
3 - 5/8"
2 - 1/2"
1 - 5/8"
STC:
NO SOUND
WITH SOUND
G2S
G3S
G6S
G8
NON-
RATED NA 8 - 5/8"8"
G8S
SEALANT; ONE SIDE, CONT.
46
46
46
46
RATING PRIORITY
3 HOUR ASSEMBLY 1
2 HOUR ASSEMBLY 2
1 HOUR ASSEMBLY 3
SMOKE RATED ASSEMBLY 4
NON RATED ASSEMBLY 5
(LOWER NUMBER, HIGHER PRIORITY)
HIGHER PRIORITY PARTITION
GYPSUM BOARD CONTINUES
THROUGH STUD CAVITY OF
LOWER WALL
LOWER PRIORITY PARTITION
HIGHER PRIORITY
CEILING/ROOF ASSEMBLY
LOWER PRIORITY PARTITIONGYPSUM BOARD CONTINUES
PAST TOP OF LOWER WALL
WALL TYPE SYMBOL
STRUCTURAL CORE SIZE
Y6S
WALL TYPE DESIGNATION
ACOUSTICAL ATTENUATION REQ'D
REFERENCE A001 FOR WALL TYPE DESCRIPTIONS
A. ALL WALLS ARE TO BE TYPE 'B3S' U.N.O.
B. PARTITION SYMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN PROVIDED FOR AREA.
C. REFER TO FINISH PLANS FOR WALL FINISH, BASE, AND CEILING INFORMATION.
D. PROVIDE WATER-RESISTANT GYPSUM BOARD ON WALLS WITH PLUMBING FIXTURES AND
WITHIN 4'-0 OF DRINKING FOUNTAINS / WATER COOLERS, U.N.O.
E. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND ABOVE CEILINGS BUT NOT
FULL HEIGHT TO STRUCTURE ABOVE.
F. PROVIDE FIRE RESISTIVE RATED GYPSUM WALL BOARD AT ALL RATED ASSEMBLIES TO
MEET ASSEMBLY REQUIREMENTS.
G. PROVIDE FIRE RESISTIVE JOINT SYSTEMS EQUAL TO WALL RATING AT ALL PENETRATIONS
AND AT HEAD/FLOOR INTERSECTIONS WITH RATED ASSEMBLIES.
H. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD, PENETRATIONS, AND ADDITIONAL
SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED WALLS.
I. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS SCHEDULED TO HAVE CERAMIC
TILE.
J. FRAME DOOR OPENINGS 4" FROM FACE OF PERPENDICULAR WALL ON HINGE SIDE AND 1'-
6" MIN. FROM FACE OF PERP. WALL ON LATCH SIDE, UNLESS NOTED OTHERWISE.
K. PROVIDE GYPSUM BOARD CONTROL JOINTS AT WALLS OVER 30'-0 IN LENGTH. LOCATE
ABOVE EDGE OF OPENING WHEN POSSIBLE.
L. AT FIRE RATED WALLS WHERE OPENINGS ARE GREATER THAN 16 SQUARE INCHES OR
WHERE TOTAL AREA OF OPENINGS EXCEEDS 100 SQUARE INCHES IN 100 SQUARE FEET,
WRAP 5/8 TYPE 'X' GYPSUM BOARD BEHIND OPENINGS PER U.L. DESIGN #U510.
M. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT
TRANSFER OF VERTICAL LOADS INTO PARTITION WHILE PROVIDING LATERAL SUPPORT
REQUIRED VIA USE OF DOUBLE TRACK TYPE (SECONDARY TRACK SET INSIDE DEEP-LEG
TRACK) OR SLOTTED TRACK TYPE, EACH ALLOWING VERTICAL MOVEMENT OF THE
STRUCTURE, PREVENTING ROTATION OF STUDS BUT MAINTAINING STRUCTURAL
PERFORMANCE OF PARTITION.
N. LINE OF STRUCTURE INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES
NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.
O. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE RESISTANT FILL MATERIAL
IN CONJUNCTION WITH AN APPROPRIATE RATED FIRESTOPPING SYTEM.
P. NON-RATED PARTITIONS SHALL USE ACOUSTICAL SEALANT.
Q. PROVIDE SHEET METAL OR FIRE RETARDANT WOOD BLOCKING IN WALL CAVITIES FOR
ITEMS THAT ARE REQUIRED TO BE SECURED TO THE WALLS. REFERENCE MECHANICAL,
PLUMBING, ELECTRICAL AND TECHNOLOGY DRAWINGS. COORDINATE WITH FURNITURE
SUPPLIER WHERE APPROPRIATE.
R. TAPE AND SPACKLE ALL PENETRATIONS IN GYPSUM BOARD PARTITIONS, INCLUDING, BUT
NOT LIMITED TO WATER LINES, DRAINS, CONDUIT, THERMOSTATS, ETC. INSTALL FIRE
RETARDANT SEALANT AT PENETRATIONS IN RATED PARTITIONS AS REQUIRED.
S. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION (S), EXTEND ATTENUATION
TO FULL HEIGHT OF PARTITION U.N.O. FLOOR TRACK TO BE SET IN A CONTINUOUS BED
OF SEALANT.
T. IN AREAS DESIGNATED TO HAVE A RATED CEILING, BUILD WALLS THAT ARE NOT
INDICATED TO GO TO DECK TO UNDERSIDE OF RATED CEILING.
U. ALTHOUGH WALL STUD SIZE / SPACING ARE LISTED, CONTRACTOR WILL VERIFY AND
PROVIDE APPROPRIATE SIZE / GAGE / SPACING OF STUDS REQUIRED FOR CONDITIONS
INDICATED AND NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO FABRICATION /
INSTALLATION.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/16/2020 2:27:30 PMG111
WALL TYPES
2019.01176
07/14/2020
CONSTRUCTION DOCUMENTS
CARMEL MEDICAL ARTS
PAVILION - FIRST FLOOR
TENANT BUILD-OUTS
12174 N. Meridian Street
Carmel, Indiana 46032
RATED WALL PRIORITY
INTERIOR PARTITION LEGEND
GENERAL PARTITION NOTES
REVISION SCHEDULE
NO. DESCRIPTION DATE
09/17/20