Loading...
HomeMy WebLinkAboutP-602PLUMBING FIXTURE SCHEDULE (BID PACKAGE 2) WC-1 WATER CLOSET - ADA, TANK 17" TO SEAT- 1/2" INTEGRAL 3" 2" TAG FIXTURE DESCRIPTION HW CW TRAP W V MOUNTING HEIGHT AMERICAN STANDARD COLONY 221AA.104 MANUFACTURER / MODEL ACCESSORIES SEAT: CHURCH 295; QUARTER TURN STOP L-1 LAVATORY - ADA, WALL HUNG 34" TO RIM 1/2" 1/2" 1-1/2" 2" 2" AMERICAN STANDARD LUCERNE 0355.012 FAUCET: SLOAN SF-2350-BAT-BDT-CP-0.5GPM-MLM-IR-FCT OFFSET P-TRAP; QUARTER TURN STOPS; TRAP AND SUPPLY INSULATION MB-1 MOP BASIN - 24" X 24", WALL MOUNTED FAUCET 36" TO FAUCET3/4" 3/4" 3" 3" 2" FIAT MSB-2424 FAUCET: T&S B-0665-CR-BSTR; INTEGRAL VACUUM BREAKER; SK-2 SINK - UNDERMOUNT REFER TO ARCHITECTURAL DRAWINGS1/2" 1/2" 1-1/2" 2' 2" JUST US-ADA-1821-A SK-1 SINK - UNDERMOUNT REFER TO ARCHITECTURAL DRAWINGS1/2" 1/2" 1-1/2" 2" 2" JUST US-ADA-1818-A FAUCET: SLOAN EAF-700-BAT-ISM-CP-1.5GPM-LAM-IR-IQ-FCT P-TRAP; QUARTER TURN STOPS P-TRAP; QUARTER TURN STOPS INTEGRAL CHECK VALVES WB-1 WASHER BOX - WHITE POWDER COATED RECESSED BOX 42" TO BOTTOM 1/2" 1/2" 2" 2" 2" GUY GRAY T200QT QUARTER TURN VALVES; 2" SLIPNUT DRAIN WSB-1 WATER SUPPLY BOX - WHITE POWDER COATED RECESSED BOX 24" TO BOTTOM- 1/2" - - - GUY GRAY BIM875 QUARTER TURN VALVE SK-4 SINK - UNDERMOUNT REFER TO ARCHITECTURAL DRAWINGS1/2" 1/2" 1-1/2" 2' 2" JUST US-ADA-1821-A SK-3 SINK - UNDERMOUNT, DISPOSER REFER TO ARCHITECTURAL DRAWINGS1/2" 1/2" 1-1/2" 2" 2" FAUCET: T&S B-2866-05-LF15 DISPOSER: INSINKERATOR BADGER 5; P-TRAP; QUARTER TURN STOPS FAUCET: T&S B-2866-05-LF15 P-TRAP; QUARTER TURN STOPS JUST US-ADA-1821-A FAUCET: SLOAN EAF-700-BAT-ISM-CP-1.5GPM-LAM-IR-IQ-FCT (BID PACKAGE 2) PLUMBING EQUIPMENT SCHEDULE MBH IN MBH OUTHP V-PH NOTES GAS DATAELECTRICAL DATA TAG MANUFACTURER MODEL # WEIGHT UNIT KW SPECIFICATION NAME CAPACITY WH-1 WATER HEATER A.O. SMITH DRE-52-9 - 50 GALLONS STORAGE CAPACITY 37 GPH RECOVERY AT 100°F TEMPERATURE RISE 277-1 - 9 - - 1 TET-1 THERMAL EXPANSION TANK A.O. SMITH TW-12 - 4.8 GALLONS TANK VOLUME - - - - - 3 TMV-1 THERMOSTATIC MIXING VALVE LAWLER 801 - 10 PSI PRESSURE DROP AT 20 GPM FLOW - - - - - 2 CP-1 CIRCULATOR PUMP ARMSTRONG E7-B - 4 GPM FLOW AT 22 FT TOTAL DYNAMIC HEAD 115-1 1/6 - - - 4, 5, 6 NOTES: 1. SET TANK TEMPERATURE AT 140°F. 2. SET OUTLET TEMPERATURE AT 120°F. #86208 3. SET TANK PRESSURE EQUAL TO INCOMING WATER PRESSURE. 4. ALL BRONZE CONSTRUCTION. 5. CONTROLLED BY AQUASTAT. 6. CONTROLLED BY 24 HR - 7 DAY PROGRAMMABLE TIME CLOCK. MODEL NUMBER MANUFACTURER/ DESCRIPTION FIXTURE NO. MARK (BID PACKAGE 2) DRAINAGE FITTING SCHEDULE WADE 8304WALL CLEANOUT: STAINLESS STEEL SHALLOW COVER WITH CENTER VANDAL PROOF SCREW.WCO PDAQUASTAT WIRING BY E.C. 3/4" 1-1/4"CW 1"CW 1-1/4"HW 1-1/4"HW 3/4"HWR 3/4"HWR 3/4"HWR 1-1/4"HW 1-1/4"CW OVER FLOOR DRAIN TERMINATE RELIEF VALVE TANK DRAIN WATER HEATER (WH-1) THERMOMETER MIXING VALVE THERMOSTATIC (TYPICAL) FLOOR THERMAL EXPANSION TANK (TET-1) ELEMENT ACCESS PANEL (TYP)TEMPERATURE RELIEF VALVE AND PRESSURE 3 /4" PRESSURE GAUGE 140 CIRCULATOR PUMP (CP-1) BALANCE VALVE BALL VALVE (TYP) CHECK VALVE (TYP) DIELECTRIC UNION (TYP) FLOOR STAINLESS STEEL COVER LONG FLAT HEAD MACHINE SCREW FINISHED WALL SURFACE 24" THREADED CLEANOUT PLUG TEST TEE STORM / WASTE RISER Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/14/2020 3:02:16 PMP-602 PLUMBING SCHEDULES AND DETAILS - BID PACKAGE 2 2019.01176 07/14/2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION -FIRST FLOOR TENANT BUILD-OUTS 12174 N. Meridian Street Carmel, Indiana 46032 NOT TO SCALE ELECTRIC WATER HEATER DETAIL2NOT TO SCALE WALL CLEANOUT DETAIL1 REVISION SCHEDULE NO. DESCRIPTION DATE 09/17/20