Loading...
HomeMy WebLinkAboutSYSTEMS PLAN - TENANT 11VHT T T T T T T T T T T T T T J J J J J J J J J J J J J J J J +54" PC PCPC+54" +54"+54"+54" +54"+54"+54"+54" +54" +54"+54"+54" +54"+54" +54"+54"+54"+54"+54"PCPCPCPCPC PC PC PC PC PC PC PC PC PCPCPC PCUSB USBE WL USB USB USB USB USB USB USB USB USB USBUSB USBUSB USBUSB USBE E E WLWL WL J CR+44"USBUSB USB H HH H H H H HV V V V V VV V V V V V V V V V V VVV V V V V VH H VV V V J J J V USBUSBUSB USBUSBUSB USB USBJ TVCR CR J CR CR CR 2 3 4 5 6 7 A B C D E F F.3 F.5 G G.8 H J I 1H1-9,11,13 VAV-108 VAV-107 VAV-106 VAV-101 VAV-109 VAV-114 VAV-115 VAV-113 VAV-105 VAV-102 VAV-103 VAV-104 VAV-110 VAV-111 VAV-112 1H1-12,14,16 1H1-12,14,16 1H1-12,14,16 1H1-12,14,16 1H1-18,20,22 1H1-15,17,19 1H1-21,23,25 1H1-27,29,31 1H1-15,17,19 1H1-27,29,31 1H1-24,26,28 1H1-30,32,34 1H1-33,35,37 1H1-9,11,13 WAITING 1100 EXAM 1121 EXAM 1122 SCALE 1103 RECEPTION 1101 EXAM 1107 EXAM 1108 EXAM 1109 EXAM 1110 EXAM 1123 EXAM 1124 EXAM 1133 EXAM 1131 EXAM 1134 EXAM 1132 DOCTOR DICT. 1112 STAFF WORK POD A1111STAFF WORK 1114 STAFF WORK POD D1142STAFF BREAK/ CONFERENCE 1156 PATIENT RESTROOM 1115 PATIENT RESTROOM 1102 EXAM 1106 PATIENT RESTROOM 1139 SCALE 1140 PORTABLE X-RAY 1153 DOCTOR DICT. 1143 EXAM 1125 EXAM 1135 X-RAY 1113 STAFF WORK POD B1119STAFF WORK POD C1137CLEAN SUPPLY 1136 PATIENT RESTROOM 1128 DOCTOR DICT. 1138 DOCTOR DICT. 1120 DME 1127 MEDS 1144 STAFF RESTROOM 1154 STAFF RESTROOM1116IT/DATA 1117 CORRIDOR 1118 EXAM 1149 EXAM 1148 EXAM 1147 EXAM 1146 SOILED HOLDING 1155 SHARED PHYSICAN OFFICE 1145 SHARED MANAGER OFFICE 1158 DIRECTOR OFFICE 1151 EXAM 1150 CORRIDOR 1104 CORRIDOR 1126 CORRIDOR 1130 CORRIDOR 1141 CORRIDOR 1157 LAB 1129 STAFF WORK 1152 BIO-HAZ 1159 ELECTRICAL 1160 1H1 1L1 +44" USB +44" USB +44" USB +44" USB +44" USB +44" USB 2 2 1 TYP. 3 4 5 12 7 6 1H1-45,47,49,F80 8 1L1-20,229 10 11 13 14 1L2 1L1-38 1L1-40 1L1-14 1L1-14 1L1-14 1L1-16 1L1-16 1L1-16 1L1-16 1L1-16 1L1-16 1L1-18 1L1-18 1L1-18 1L1-18 1L1-18 1L1-18 1L1-24 1L1-24 1L1-24 1L1-24 1L1-261L1-42 1L1-421L1-40 1L1-40 1L1-40 1L1-38 1L1-38 1L1-38 1L1-38 1L1-36 1L1-36 1L1-36 1L1-36 1L1-36 1L1-34 1L1-34 1L1-34 1L1-34 1L1-34 1L1-32 1L1-32 1L1-32 1L1-32 1L1-32 1L1-30 1L1-30 1L1-30 1L1-30 1L1-30 1L1-28 1L1-28 1L1-28 1L1-28 1L1-28 1L1-14 1L1-14 1L1-21L1-2 1L1-21L1-21L1-4 1L1-6 1L1-6 1L1-42 1L1-12 1L1-10 1L1-8 1L1-8 1L1-2 1L1-2 1L1-2 1L1-4 1L1-42 1L1-44 1L1-44 1L1-44 1L1-44 1L1-46 1L1-46 1L1-48 1L1-44 1L1-46 1L1-46 1L1-521L1-50 1L1-50 1L1-50 1L1-44 1L1-50 1L1-46 1L1-52 1L1-46 1L1-52 1L1-48 1L1-48 1L1-481L1-52 1L1-48 1L1-48 1L1-52 1L1-52 1L1-50 1L1-50 TYP. TYP. 1L1-56 1L1-56 1L1-54 1L1-58 1L1-58 1L1-58 1L1-58 1L1-58 1L1-42 1L1-60 1L1-60 1L1-62 1L1-621L1-60 1L1-76 1L1-76 1L1-801L1-781L1-801L1-64 1L1-64 1L1-64 1L1-64 1L1-64 1L1-66 1L1-66 1L1-66 1L1-66 1L1-66 1L1-68 1L1-68 1L1-681L1-70 1L1-68 1L1-68 1L1-70 1L1-70 1L1-70 1L1-70 1L1-72 1L1-72 1L1-72 1L1-72 1L1-72 1L1-74 1L1-74 1L1-74 1L1-74 1L1-74 1L1-42 1L1-10 1L1-10 1L2-13 1L2-11 1L2-111L2-191L2-171L2-151L2-151L2-151L2-151L2-21 1L2-21 1L2-21 1L2-11 1L2-9 1L2-9 1L2-9 1L2-91L2-91L2-11 1L2-7 1L2-7 1L2-7 1L2-7 1L1-76 1L2-5 1L2-5 1L2-5 1L2-3 1L2-3 1L2-3 1L2-3 1L2-3 1L2-3 1L2-1 1L2-11L2-1 1L2-1 1L2-1 1L2-1 1L1-76 1L1-82 1L1-82 1L1-82 1L1-841L1-76 1L1-84 1L1-84 3 3 3 3 3 3 3 3 3 3 3 3 15 16 17 TYP. TYP. 1L1-42 18 19 TYP. 19 3 3 20 21 TYP. 22 1L1-40 1L1-82 2 1L1-410 1L2-9 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/15/2020 3:06:39 PME301.11 FIRST LEVEL POWER/SYSTEMS PLAN -TENANT 11 2019.00780 7.14.2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION 12174 N. Meridian Street Carmel, Indiana 46032 1/8" = 1'-0"1 FIRST LEVEL POWER/SYSTEMS PLAN -TENANT 11 GENERAL NOTES A. REFER TO DRAWING E001 FOR ELECTRICAL SYMBOLS AND ADDITIONAL GENERAL NOTES. B. COORDINATE ALL WORK WITH THE OWNER AND THE OTHER TRADES ON THE PROJECT. C. REFER TO M AND P SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. D. PROTECT ALL FINISHES, EQUIPMENT, AND DEVICES DURING THE WORK. E. REFER TO ARCHITECTURAL SCHEDULES, DETAILS, AND ELEVATIONS FOR ADDITIONAL INFORMATION ON DEVICE LOCATIONS PRIOR TO ROUGH-IN. F. COORDINATE ALL WORK WITH THE OWNER'S SYSTEMS VENDORS FOR DEVICES AND WIRING FOR DATA, I.T. SERVICES, AND SECURITY SYSTEMS. G. ELECTRICAL SERVICES SHALL NOT ROUTE THROUGH ANY IDF OR MDF ROOM UNLESS DIRECTLY SERVING THAT \ROOM. H. CONTRACTOR SHALL VERIFY CORD AND PLUG CONNECTED EQUIPMENT CORD CONFIGURATION AND PROVIDE MATCHING RECEPTACLE AS REQUIRED. I. ALL RECEPTACLES WITHIN SIX FEET OF A SINK SHALL BE GFCI TYPE. DEVICES MAY NOT BE IDENTIFIED AS GFCI ON PLANS, BUT SHALL BE PROVIDED ACCORDING TO THE REQUIREMENT. J. ALL SPECIAL TYPE RECEPTACLES SHALL BE NEMA 6-20R UNLESS NOTED OTHERWISE AND SHALL BE CIRCUITED WITH (2) #10 + (1) #10 NEUTRAL + (1) #10 GROUND. COORDINATE REQUIREMENTS WITH OWNER SUPPLIED EQUIPMENT PRIOR TO INSTALLATION. K. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN, ARCHITECTURAL ELEVATIONS, HVAC EQUIPMENT, DIFFUSERS, DUCTWORK, PIPING, SUPPORTS, AND STRUCTURE PRIOR TO ROUGH-IN. L. ALL EXIT SIGNS, EMERGENCY BATTERY LIGHTING UNITS, AND LIGHT FIXTURES SHOWN WITH EMERGENCY BATTERY BACKUP OR INDICATED AS A NIGHT LIGHT ("NL") SHALL BE PROVIDED WITH AN UNSWITCHED "HOT" CIRCUIT CONDUCTOR. M. AT LOCATIONS WITH TWO OR MORE WALL SWITCHES, ALL SWITCHES SHALL BE INSTALLED GANGED IN A COMMON SWITCH BOX. N. AT LOCATIONS WHERE LIGHT SWITCHES AND ABOVE-COUNTER RECEPTACLES ARE TO BE MOUNTED ADJACENT TO EACH OTHER, THE DEVICES SHALL BE INSTALLED AT THE SAME HEIGHT. O. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED. SENSOR MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITIES AS REQUIRED. CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL-TECHNOLOGY TYPE. SENSORS SHALL INCLUDED ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN ROOM/AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE - MANUAL ON/AUTO OFF. P. PROVIDE PULL STRING IN ALL EMPTY CONDUITS. Q. CONTRACTOR TO PROVIDE ROUGH-INS ONLY FOR DATA, I.T. SERVICES, AND SECURITY SYSTEMS. DATA, I.T. SERVICES, AND SECURITY SYSTEMS DEVICES AND WIRING TO BE PROVIDED BY THE OWNERS SYSTEMS VENDORS. PROVIDE ROUGH-INS WITH "RING AND STRING". PLAN NOTES 1 EXISTING TO REMAIN. 2 CONNECT AUTO OPERATORS COMPLETE. PROVIDE ALL ASSOCIATED ROUGH-INS AND CONTROL WIRING IN CONDUIT AS REQUIRED. PROVIDE TOGGLE DISCONNECT SWITCH. 3 PROVIDE 3P-30A, 480V, FUSIBLE DISCONNECT SWITCH FUSED PER UNIT MANUFACTURERS RECOMMENDATIONS. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. 4 DEVICES FOR WALL MOUNTED PC AND MONITOR. VERIFY EXACT HEIGHT AND LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 5 DEVICE FOR WALL MOUNTED EQUIPMENT. VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 6 REFER TO EQUIPMENT SITE SPECIFIC DRAWINGS FOR ROOM LAYOUT, SPECIFICATIONS, DETAILS AND ADDITIONAL ELECTRICAL SCOPE FOR THIS ROOM. ALL DRAWINGS, ROUGH-INS, AND SPECIFICATIONS ARE NOT REPEATED ON THIS DRAWING. ALL ELECTRICAL WORK SHOWN ON THE EQUIPMENT DRAWINGS INDICATED AS BY CONTRACTOR OR CUSTOMER SHALL BE INCLUDED IN ELECTRICAL SCOPE. 7 PROVIDE 3P-80A, 480V MAIN CIRCUIT BREAKER IN APPROVED FLUSH MOUNTED NEMA ENCLOSURE WITH NEUTRAL AND GROUND ACCESSORIES. 8 120/208V SINGLE PHASE, SN LOAD CENTER WITH SINGLE MAIN BREAKER. 9 REMOTE SWITCH FOR OPERATION OF SHUNT TRIP FEATURE ON 480V MAIN BREAKER. PROVIDE MUSHROOM TYPE "EMERGENCY OFF" RED BUTTON. 10 6" X 6" x 4"D JUNCTION BOX. SPLIT REMOVABLE COVER SHALL CONTAIN A 2" GROMMETED OPENING. LOCATE COVER +6" BELOW COUNTER TOP. PROVIDE GROMMETED OPENING IN COUNTER TOP FOR CABLE ACCESS TO EQUIPMENT.. 11 6" X 6" x 4"D JUNCTION BOX. SPLIT REMOVABLE COVER SHALL CONTAIN A 2" GROMMETED OPENING. LOCATE COVER FLUSH IN FINISHED FLOOR. 12 6" X 6" x 4"D JUNCTION BOX. SPLIT REMOVABLE COVER SHALL CONTAIN A 2" GROMMETED OPENING. LOCATE COVER +43" AFF. 13 12" TROUGH COVER WITH SPLIT REMOVABLE COVER PLATE. COVER SHALL CONTAIN AN 8" X 3" GROMMETED OPENING. LOCATE COVER FLUSH IN FINISHED FLOOR. 14 12" TROUGH COVER WITH SPLIT REMOVABLE COVER PLATE. COVER SHALL CONTAIN AN 8" X 3" GROMMETED OPENING. LOCATE COVER PLATE +12" AFF. PROVIDE 4' SEALTITE WITH 90 DEGREE CONNECTORS AT EACH END. 15 DEVICES FOR WALL MOUNTED TELEVISION. VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 16 EMERGENCY BATH PULL STATION. VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 17 EMERGENCY BATH STATION WALL MOUNTED LIGHT. VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 18 PROVIDE (2) 4" CONDUIT TO TENANT SPACE FOR TELECOM UTILITY SERVICE. 19 ALL RECEPTACLES IN THIS ROOM SHALL BE TAMPER PROOF HOSPITAL GRADE AND SHALL BE WIRED WITH HEALTHCARE RATED MC CABLE COMPLETE ALL THE WAY BACK TO THE PANEL. 20 DEVICE FOR PORTABLE X-RAY. VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH EQUIPMENT SUPLLIER. 21 PROVIDE ROUGH-INS FOR CARD READER AS REQUIRED. REFER TO ELECTRICAL DETAILS FOR ADDITIONAL INFORMATION. 22 PROVIDE 4' X 8' X 3/4" THICK A-C GRADE, VOID-FREE PLYWOOD MAT FROM FLOOR TO 8'-0" HIGH FOR TELECOM BACKBOARD. PAINT ALL FACES AND EDGES OF PLYWOOD SECTIONS WITH A MINIMUM OF TWO COATS OF FIRE-RETARDANT PAINT PRIOR TO INSTALLATION. REVISION SCHEDULE NO. DESCRIPTION DATE 09/17/20