Loading...
HomeMy WebLinkAboutT2-A121OC OC OC OC OC OC OC REFLECTED CEILING PLAN LEGEND A. ALL CEILINGS TO BE ACT-1 U.N.O. B. ALL A.C.T. CEILINGS TO BE 9'-0" A.F.F. USING 15/16" WHITE METAL TEE GRID. U.N.O. C. GYPSUM BOARD CONTROL JOINTS: a. PROVIDE AT INTERIOR CEILINGS (WITH PERIMETER RELIEF) OVER 50'-0" IN LENGTH IN ANY DIRECTION. TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 2500 SQFT. b. PROVIDE AT INTERIOR CEILINGS (WITHOUT PERIMETER RELIEF) OVER 30'-0" IN LENGTH IN ANY DIRECTION. TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 900 SQFT. c. PROVIDE AT EXTERIOR CEILINGS AND SOFFITS OVER 30'-0" IN LENGTH IN ANY DIRECTION. TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 900 SQFT. d. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEMENTS AND/OR AT THE DIRECTION OF THE ARCHITECT. D. REFERENCE INTERIOR ELEVATIONS AND DETAILS FOR GYPSUM BOARD SOFFITS ABOVE CABINETS (IF ANY) AND GYPSUM BOARD BULKHEADS. E. SEE INTERIOR ELEVATIONS AND/OR SECTIONS FOR MOUNTING HEIGHTS OF ANY WALL MOUNTED LIGHT FIXTURES. 2'x4' LAY-IN FIXTURE 2'x2' LAY-IN FIXTURE 1'x4' LAY-IN FIXTURE 1'x4' WALL-MOUNTED FLUORESCENT LIGHT FIXTURE COVE LIGHT FIXTURE ACT-1 8' - 0" CM E 4' SURFACE MOUNTED LIGHT FIXTURE RECESSED CAN LIGHT PENDANT LIGHT FIXTURE WALL-MOUNTED INTERIOR LIGHT FIXTURE WALL-MOUNTED EXTERIOR LIGHT FIXTURE EXIT LIGHT RECESSED SECURITY CAMERA SURFACE-MOUNTED STROBE EMERGENCY LIGHT FIXTURE SUPPLY DIFFUSER RETURN DIFFUSER LINEAR DIFFUSER EXHAUST FAN GRILL CARBON MONOXIDE DETECTOR SPRINKLER HEAD TV MOUNTING BRACKET 2'x2' SUSPENDED ACOUSTICAL CEILING GYPSUM BOARD CEILING CEILING IDENTIFICATION CEILING TYPE FINISH HEIGHT (AFF) CEILING TYPE LEGEND ACT-1 -- 2x2 ACOUSTICAL PANELS 7 8 98.8 A B C D F G H J E F.3 8.5 G.1 H.5 7.1 D.2 6.9 2 T2-A121 1 1 3 T2-A121 ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" ACT-1 9' - 0" GYP 8' - 11" GYP 8' - 11" GYP 8' - 11" GYP 8' - 0" GYP 8' - 11"1' - 0"7' - 4 1/4" 2' - 6" SECOND LEVEL 114' - 0" METAL STUD AND GYPSUM BOARD BULKHEAD; BOTTOM AT +8'-11" AFF. BRACE AS REQUIRED. EXISTING STRUCTURAL FRAMING EXISTING CURTAIN WALL FRAMING EXISTINGSPANDREL GLAZING UNIT CLIP ANGLE ATTACHED TO CURTAIN WALL FRAMING; PROVIDE ISOLATATION BETWEEN ANGLE AND CURTAIN WALL. 8' - 11" 1/4" SEALANT JOINT AT PERIMETER 2' - 1 1/8" STRUCTURAL FRAMING METAL STUD AND GYPSUM BOARD BULKHEAD; BRACE AS REQUIRED T2-A521 6 Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:7/16/2020 2:12:44 PMT2-A121 FIRST FLOOR REFLECTED CEILING PLAN 2019.01176 07/14/2020 CONSTRUCTION DOCUMENTS CARMEL MEDICAL ARTS PAVILION - FIRST FLOOR TENANT BUILD-OUTS 12174 N. Meridian Street Carmel, Indiana 46032 N 1/8" = 1'-0"T2-A121 1 REFLECTED CEILING PLAN 1 ALIGN FACE OF BULKHEAD WITH FACE OF PARTITION KEYED REF. CEILING PLAN NOTES (NOTED WITH )1 1" = 1'-0"T2-A121 2 BULKHEAD AT EXTERIOR WALL 1/4" = 1'-0"T2-A121 3 BULKHEAD REVISION SCHEDULE NO. DESCRIPTION DATE 09/17/20