REFLECTED CEILING PLAN LEGEND
A. ALL CEILINGS TO BE ACT-1 U.N.O.
B. ALL A.C.T. CEILINGS TO BE 9'-0" A.F.F. USING 15/16" WHITE METAL TEE GRID. U.N.O.
C. GYPSUM BOARD CONTROL JOINTS:
a. PROVIDE AT INTERIOR CEILINGS (WITH PERIMETER RELIEF) OVER 50'-0" IN LENGTH IN ANY DIRECTION.
TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 2500 SQFT.
b. PROVIDE AT INTERIOR CEILINGS (WITHOUT PERIMETER RELIEF) OVER 30'-0" IN LENGTH IN ANY DIRECTION.
TOTAL AREA BETWEEN CONTROL JOINTS SHALL NOT EXCEED 900 SQFT.
c. PROVIDE AT EXTERIOR CEILINGS AND SOFFITS OVER 30'-0" IN LENGTH IN ANY DIRECTION. TOTAL AREA
BETWEEN CONTROL JOINTS SHALL NOT EXCEED 900 SQFT.
d. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEMENTS AND/OR AT THE DIRECTION OF THE
ARCHITECT.
D. REFERENCE INTERIOR ELEVATIONS AND DETAILS FOR GYPSUM BOARD SOFFITS ABOVE CABINETS (IF ANY)
AND GYPSUM BOARD BULKHEADS.
E. SEE INTERIOR ELEVATIONS AND/OR SECTIONS FOR MOUNTING HEIGHTS OF ANY WALL MOUNTED LIGHT
FIXTURES.
2'x4' LAY-IN FIXTURE
2'x2' LAY-IN FIXTURE
1'x4' LAY-IN FIXTURE
1'x4' WALL-MOUNTED
FLUORESCENT LIGHT FIXTURE
COVE LIGHT FIXTURE
ACT-1
8' - 0"
CM
E
4' SURFACE MOUNTED LIGHT
FIXTURE
RECESSED CAN LIGHT
PENDANT LIGHT FIXTURE
WALL-MOUNTED INTERIOR LIGHT
FIXTURE
WALL-MOUNTED EXTERIOR LIGHT
FIXTURE
EXIT LIGHT
RECESSED SECURITY CAMERA
SURFACE-MOUNTED STROBE
EMERGENCY LIGHT FIXTURE
SUPPLY DIFFUSER
RETURN DIFFUSER
LINEAR DIFFUSER
EXHAUST FAN GRILL
CARBON MONOXIDE DETECTOR
SPRINKLER HEAD
TV MOUNTING BRACKET
2'x2' SUSPENDED ACOUSTICAL
CEILING
GYPSUM BOARD CEILING
CEILING IDENTIFICATION
CEILING TYPE
FINISH HEIGHT (AFF)
CEILING TYPE LEGEND
ACT-1 -- 2x2 ACOUSTICAL PANELS
7 8 98.8
A
B
C
D
F
G
H
J
E
F.3
8.5
G.1
H.5
7.1
D.2
6.9
2
T2-A121
1
1
3
T2-A121
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
GYP
8' - 11"
GYP
8' - 11"
GYP
8' - 11"
GYP
8' - 0"
GYP
8' - 11"1' - 0"7' - 4 1/4" 2' - 6"
SECOND LEVEL
114' - 0"
METAL STUD AND GYPSUM BOARD
BULKHEAD; BOTTOM AT +8'-11" AFF.
BRACE AS REQUIRED.
EXISTING STRUCTURAL
FRAMING
EXISTING CURTAIN WALL
FRAMING
EXISTINGSPANDREL GLAZING UNIT
CLIP ANGLE ATTACHED TO CURTAIN
WALL FRAMING; PROVIDE
ISOLATATION BETWEEN ANGLE AND
CURTAIN WALL.
8' - 11"
1/4" SEALANT JOINT AT
PERIMETER
2' - 1 1/8"
STRUCTURAL FRAMING
METAL STUD AND GYPSUM BOARD
BULKHEAD; BRACE AS REQUIRED
T2-A521
6
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/16/2020 2:12:44 PMT2-A121
FIRST FLOOR
REFLECTED CEILING
PLAN
2019.01176
07/14/2020
CONSTRUCTION DOCUMENTS
CARMEL MEDICAL ARTS
PAVILION - FIRST FLOOR
TENANT BUILD-OUTS
12174 N. Meridian Street
Carmel, Indiana 46032
N
1/8" = 1'-0"T2-A121
1 REFLECTED CEILING PLAN
1 ALIGN FACE OF BULKHEAD WITH FACE OF PARTITION
KEYED REF. CEILING PLAN NOTES (NOTED WITH )1
1" = 1'-0"T2-A121
2 BULKHEAD AT EXTERIOR WALL
1/4" = 1'-0"T2-A121
3 BULKHEAD
REVISION SCHEDULE
NO. DESCRIPTION DATE
09/17/20