HomeMy WebLinkAboutT2-A701WD
CPT CARPET
LVT LUXURY VINYL TILE
MT METAL TRANSITION STRIP
P PAINT
PL PLASTIC LAMINATE
RS ROLLER SHADES
SS SOLID SURFACE
TB TILE BASE
VB VINYL BASE
WT WALL TILE
FINISH LEGEND
WALLS
P-1 MANUFACTURER: SHERWIN WILLIAMS
NUMBER: SW7646
COLOR: FIRST STAR
P-2 MANUFACTURER: SHERWIN WILLIAMS
NUMBER: SW6942
COLOR: SPLASHY
P-3 MANUFACTURER: SHERWIN WILLIAMS
NUMBER: SW7073
COLOR: NETWORK GRAY
WT-1 MANUFACTURER: DALTILE
STYLE: UNIFORM CONCRETE
SIZE: 12" X 24"
COLOR: MEDIUM GREY UC14
INSTALLATION: STACKED
GROUT: MAPEI - SILVER #27
FINISH MATERIAL KEY
MILLWORK
PL-1 MANUFACTURER: WILSONART
NUMBER: 5024K-19
COLOR: BLACKBIRD
FINISH: LENO WEAVE
PL-2 MANUFACTURER: WILSONART
NUMBER: 5013K-19
COLOR: MUSHROOM
FINISH: LENO WEAVE
PL-3 MANUFACTURER: WILSONART
NUMBER: 5012K-19
COLOR: MAGNOLIA
FINISH: LENO WEAVE
*ALL PLASTIC LAMINATE SURFACES TO HAVE MATCHING
3MM PVC EDGING ON EXPOSED EDGES*
FLOORS
CPT-1 MANUFACTURER: J & J FLOORING
STYLE: WELL VERSED
NUMBER: 7072 - 2027
COLOR: BLAKE
SIZE: 24" X 24"
INSTALLATION: ASHLAR
CPT-2 MANUFACTURER: INTERFACE
STYLE: STEP REPEAT
NUMBER: SR899
COLOR: ONYX 10491
SIZE: 50 CM X 50 CM
INSTALLATION: MONOLITHIC
LVT-1 MANUFACTURER: MOHAWK
STYLE: GROWN UP
SIZE: 9" X 59"
NUMBER: 958
COLOR: COLE
BASE
TB-1 MANUFACTURER: DALTILE
STYLE: UNIFORM CONCRETE
SIZE: 6" X 12" COVE BASE
COLOR: MEDIUM GREY UC14
GROUT: MAPEI - SILVER #27
VB-1 MANUFACTURER: JOHNSONITE
STYLE: 4" COVE
COLOR: SHARK FIN CG
LOCATION: ALL WALLS
VB-2 MANUFACTURER: JOHNSONITE
STYLE: 4" COVE
COLOR: BLACK MAGIC B
LOCATION: ALL CASEWORK
OTHER
MT-1 MANUFACTURER: SCHLUTER
STYLE: JOLLY
FINISH: SATIN ANODIZED ALUMINUM
WINDOW SILLS
SS-1 MANUFACTURER: WILSONART
STYLE: EASED EDGE
COLOR: 9221 SP LUMINOUS WHITE
WINDOW TREATMENT
RS-1 ROLLER SHADES
STYLE: BUILDING STANDARD
WAITING
1201
LVT-1
P-1
VB-1
TREATMENT
1204
CPT-1
P-1
VB-1
TREATMENT
1205
CPT-1
P-1
VB-1
PHYSICIAN
WORK
1207
CPT-1
P-1
VB-1
LAUNDRY
1208
LVT-1
P-1
VB-1
STAFF
BREAK
1211
LVT-1
P-1
VB-1 OFFICE
1212
CPT-1
P-1
VB-1
PATIENT
RESTROOM
1209
LVT-1
WT-1 / P-1
TB-1
REHAB
1206
CPT-1
P-1
VB-1
STAFF
RESTROOM
1210
LVT-1
WT-1 / P-1
TB-1
RECEPTION
1203
LVT-1
P-1
VB-1VESTIBULE
1200
CPT-2
P-1
VB-1 LVT-1 CPT-1CPT-1 LVT-111' - 4 5/8"PL-1VB-2PL-1VB-2P-2P-2 P-2RS-1 RS-1
RS-1
RS-1
RS-1
RS-1
RS-1
RS-1
RS-1
RS-1RS-1
1
1
1
A. ALL GENERAL FINISHES ARE NOTED ON FINISH ROOM TAG U.N.O.
B. REFERENCE REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFO.
C. ALL NEW INTERIOR FINISHES, INCLUDING FLOOR, WALL, AND CEILING MATERIALS,
SHALL BE IN ACCORDANCE WITH FLAME SPREAD AND SMOKE DEVELOPMENT
REQUIREMENTS FOUND IN THE CURRENT EDITION OF THE INTERNATIONAL BUILDING
CODE.
D. CONTRACTOR TO SUBMIT A MINIMUM OF (3) THREE SAMPLES OF EACH FINISH TO
DESIGNER FOR APPROVAL PRIOR TO ORDERING. ALTERNATES WILL NOT BE
ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT.
E. CONTRACTOR TO IMMEDIATELY NOTIFY ARCHITECT IF A SPECIFIED FINISH ITEM
BECOMES UNAVAILABLE.
F. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL NEW INTERIOR WALL
AND CEILING FINISHES WILL BE CLASS B MINIMUM, WITH A FLAME SPREAD RATING OF
75 MAXIMUM AND A SMOKE DEVELOPED INDEX OF 450 MAXIMUM PER IBC SECTION 803
G. PREPARE ALL FLOOR AND WALL CONSTRUCTION, NEW AND/OR EXISTING, TO RECEIVE
NEW FINISHES IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDED
INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
H. PRIOR TO INSTALLATION OF NEW FINISHES, CONTRACTOR SHALL INSPECT ALL
SUBSTRATES. IF A SUBSTRATE IS DEEMED UNACCEPTABLE, THE CONTRACTOR SHALL
TAKE THE NECESSARY STEPS TO RECTIFY THE SITUATION OR CONTACT THE
ARCHITECT WITH THE CONCERN. PROCEEDING WITH THE INSTALLATION OF FINISHES
WILL BE INDICATION THAT THE INSTALLER / FINISHER ACCEPTS CONDITION OF
SUBSTRATE.
I. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR
ALL FINISHES.
J. ALL NECESSARY TILE FLOORING UNDERLAYMENT TO BE PROVIDED AND INSTALLED BY
FLOORING CONTRACTOR
K. FLOORING CONTRACTOR TO LEVEL SUBSTRATE AS REQUIRED TO ACCEPT NEW
FLOORING MATERIAL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.
L. CARPET SEAMS TO BE LOCATED AT CENTERLINE OF DOOR WHEN DOOR IS IN CLOSED
POSITION
M. ALL FLOORING TRANSITIONS SHALL COMPLY WITH ADA GUIDELINES. FLOORING
CONTRACTOR TO SUBMIT A DIAGRAM SHOWING FLOORING TRANSITION LOCATIONS
FOR DESIGNERS APPROVAL PRIOR TO INSTALLATION.
N. ALL TRANSITION/REDUCER STRIPS AND OTHER THRESHOLDS TO BE LOCATED AT
CENTERLINE OF DOOR WHEN IN CLOSED POSITION
O. ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS, U.N.O.
P. FLOOR FINISHES ARE TO EXTEND UNDER NEW BUILT-IN CABINETS.
Q. FINISH LEVEL OF GYP. BD. WALLS AND SOFFITS TO BE LEVEL 4, U.N.O.
R. ALL PAINTED WALLS TO BE PAINTED P-1, UNLESS NOTED OTHERWISE.
S. ALL GYP. BOARD CEILINGS TO BE PAINTED P-1, U.N.O.
T. ALL PAINTED SURFACES SHALL RECEIVE A MINIMUM OF (1) ONE BASE COAT AND (2)
TWO FINISH COATS
U. PAINTED SHEEN LEVEL TO BE SATIN/EGG-SHELL FOR ALL WALLS, U.N.O. SHEEN FOR
ALL WET AREA WALLS, METAL DOORS AND METAL FRAMES TO BE SEMI-GLOSS.
V. PAINT ALL EXPOSED METAL SURFACES, SUCH AS GRILLES, FIRE EXTINGUISHER
CABINETS, ETC. WITH PAINT TO MATCH ADJACENT SURFACE.
W. ALL NEW INTERIOR WINDOW SILLS TO BE SS-1, UNLESS NOTED OTHERWISE.
X. ALL METAL DOORS AND FRAMES TO BE PAINTED P-3.
Y. ALL DOORS TO BE PLAIN SLICED, WHITE BIRCH WITH ONYX STAIN. CONTRACTOR TO
PROVIDE STAIN SAMPLES TO ARCHITECT / DESIGNER FOR APPROVAL
ROOM NAME
ROOM #
FLOOR BASE
WALLS
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:7/16/2020 2:13:06 PMT2-A701
FIRST FLOOR FINISH
PLAN
2019.01176
07/14/2020
CONSTRUCTION DOCUMENTS
CARMEL MEDICAL ARTS
PAVILION - FIRST FLOOR
TENANT BUILD-OUTS
12174 N. Meridian Street
Carmel, Indiana 46032
N
1/8" = 1'-0" T2-A701
1 FIRST FLOOR FINISH PLAN
GENERAL FINISH NOTES
FINISH ROOM TAG KEY
REVISION SCHEDULE
NO. DESCRIPTION DATE
(KEY)_FINISH PLAN NOTES
MARK DESCRIPTION
1 ALIGN FLOORING TRANSITION WITH FINISH FACE OF WALL.
1
09/17/20