HomeMy WebLinkAboutBuilding 12 - Lot 62_63_64_65 - Truss DetailsDE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. Job: 2005540-12T 20 truss design(s) 76789-W1 09/03/2020 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Indiana Residential Building Code 2020 based on IRC 2018 with Indiana specific amendments. 675 IAC 14-4.4-81 Section R802.10.1; truss design drawings, R802.10.1; truss design drawings shall be provided to the building official as required by the General Administrative Rules (675 IAC 12) for Class 1 structures or by local ordinance for Class 2 structures. Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 1.5x4 =4x4 3x4 3x4 7 6 1 2 3 54 T1 T2 W2 B1 W1 HW1 Scale = 1:27.1 Plate Offsets(X,Y):[2:0-3-6,0-0-11],[6:Edge,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.24 Vert(LL)0.11 7>540360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 LumberDOL 1.15 BC 0.56 Vert(CT)-0.10 7>550240 TCDL 10.0 RepStress Incr NO WB 0.05 Horz(CT)-0.02 2n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:16 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud SLIDER Left2x4SPFStud--1-6-0 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor4-11-0ocpurlins, exceptend verticals,and2-0-0ocpurlins:4-5. BOT CHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS (lb/size)2=236/0-4-0,(min.0-1-8),6=245/0-1-8,(min.0-1-8) Max Horiz2=34(LC8) Max Uplift2=-171(LC8),6=-164(LC9) Max Grav2=296(LC34),6=251(LC33) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. TOP CHORD 2-3=-284/215 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zone; cantilever left exposed ; end verticalleftexposed;porch leftandrightexposed;Lumber DOL=1.60plategrip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns. Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 6)Provideadequatedrainage topreventwaterponding. 7)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 8)Bearingat joint(s)6considersparalleltograin valueusingANSI/TPI1angle tograin formula.Buildingdesigner should verifycapacityofbearing surface. 9)Providemechanical connection(byothers)of truss tobearingplateat joint(s)6. 10)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding171 lbupliftatjoint2and164 lbupliftat joint6. 11)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. 12)Graphicalpurlinrepresentationdoesnotdepictthe sizeor theorientationof thepurlinalong the topand/orbottom chord. 13)Hanger(s)orotherconnectiondevice(s) shallbeprovided sufficient to support concentrated load(s)48 lbdownand118 lbupat2-6-8,and49 lbdownand37 lbupat4-9-4 on top chord,and54lbdownand78 lbupat2-6-8,and20 lbdownand25 lbupat4-9-4onbottomchord.Thedesign/selectionof such connectiondevice(s) isthe responsibilityofothers. LOADCASE(S)Standard 1)Dead + Snow(balanced):LumberIncrease=1.15,Plate Increase=1.15 UniformLoads(lb/ft) Vert:1-4=-51,4-5=-61,6-8=-20 ConcentratedLoads(lb) Vert:4=-10,5=-30,7=-16,6=-20 Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 G01 2 12005540-12T Jack-Closed Girder Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:19 Page: 1 ID:7tbsC3t37vCoe4ToE5YZQ2yhiJA-EbvTp_4SI?bn3AslQSAqoIH79ZcVOjDos5jngWyhd Ww DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 5 1 2 3 T1 B1 HW1 Scale = 1:20.3 Plate Offsets(X,Y):[2:0-3-0,0-8-15] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.14 Vert(LL)0.015-8>999360 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.07 Vert(CT)0.015-8>999240 TCDL 10.0 RepStress Incr NO WB 0.00 Horz(CT)0.00 4n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:11 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 SLIDER Left2x4SPFStud--1-6-0 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor3-5-10ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. REACTIONS (lb/size)2=100/0-5-4,(min.0-1-8),4=34/Mechanical,(min.0-1-8), 5=17/Mechanical,(min.0-1-8) Max Horiz2=37(LC10) Max Uplift2=-122(LC10),4=-45(LC10),5=-26(LC10) Max Grav2=153(LC19),4=54(LC19),5=43(LC7) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. NOTES 1)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zone; cantilever left exposed ; end verticalleftexposed;porch leftandrightexposed;Lumber DOL=1.60plategrip DOL=1.60 2)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10;Min. flatroof snow loadgoverns. 3)Unbalanced snow loadshavebeen considered for thisdesign. 4)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 5)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 6)Refer togirder(s) for truss to truss connections. 7)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding45 lbupliftat joint4,122 lbupliftat joint2and26 lbupliftat joint5. 8)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. 9)In theLOADCASE(S) section,loadsapplied to the faceof thetrussarenotedas front(F)orback(B). LOADCASE(S)Standard 1)Dead + Snow(balanced):LumberIncrease=1.15,Plate Increase=1.15 UniformLoads(lb/ft) Vert:1-2=-51 TrapezoidalLoads(lb/ft) Vert:2=9(F=30,B=30)-to-7=-8(F=22,B=22),7=-8(F=22,B=22)-to-3=-10(F=20,B=20),3=-10(F=20,B=20)-to-4=-43(F=4,B=4),6=0(F=10,B=10)-to-8=-6 (F=7,B=7),8=-6(F=7,B=7)-to-5=-17(F=1,B=1) Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 G02 2 12005540-12T DiagonalHip Girder Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:20 Page: 1 ID:3jflU6U_f4ALo91eMNz37IyhiJg-ioTr1J443JjehKQy_9i3KVqJRz3O7AFx4lTLCyyhdWv DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 57 32 1 31230 3 29 284527 6 26 7 25 8 24 9 23 10 22 11 21 121314151617181920 W1 T2 T1 T3 T2 T1 W1 B1 B1B3B2 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9ST9ST9ST9ST9ST9ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 Scale = 1:80.8 Plate Offsets(X,Y):[12:0-3-0,0-2-0], [20:0-3-0,0-2-0], [40:0-3-0,0-3-0], [49:0-3-0,0-3-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate Grip DOL 1.15 TC 0.32 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.16 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.16 Horz(CT)0.0132n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:328 lbFT = 20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud OTHERS 2x4SPF No.2*Except*ST1,ST2,ST3,ST4:2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins, exceptend verticals,and2-0-0ocpurlins(6-0-0max.):12-20. BOT CHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. WEBS 1 Rowatmidpt 9-51,10-50,11-49,13-48,14-46, 15-45,16-44,17-43,18-42,19-41, 21-40,22-39,23-38 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordancewithStabilizer Installationguide. REACTIONS Allbearings48-0-0. (lb)-Max Horiz57=219(LC15) Max UpliftAlluplift100(lb)orlessat joint(s)34,35,36,37,38,39,40, 42,43,44,45,46,49,50,51,52,53,54,55except32=-169 (LC13),33=-196(LC17),56=-201(LC16),57=-181(LC12) Max GravAllreactions250(lb)orlessat joint(s)32,33,34,35,36,37, 38,39,40,41,42,43,44,45,46,48,49,50,51,52,53,54,55, 57except56=258(LC30) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhen shown. TOP CHORD 7-58=-94/282,8-58=-85/287,8-9=-113/339,9-10=-131/391,10-11=-150/446,11-12=-167/490,12-13=-149/461, 13-14=-149/461,14-15=-149/461,15-59=-149/461,16-59=-149/461,16-60=-149/461,17-60=-149/461,17-18=-149/461, 18-19=-149/461,19-20=-149/461,20-21=-166/490,21-22=-151/446,22-23=-130/391,23-24=-113/339,24-61=-85/287, 25-61=-94/282 NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneand C-C Corner(3E)-0-10-12 to4-0-0,Exterior(2N)4-0-0 to17-10-0, Corner(3R)17-10-0 to22-7-10,Exterior(2N)22-7-10 to30-2-0, Corner(3R)30-2-0 to34-11-10,Exterior(2N) 34-11-10 to48-10-12 zone; cantilever leftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategripDOL=1.60 3)Trussdesigned for windloads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard Industry GableEndDetailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:Lum DOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(LumDOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0;Cs=1.00;Ct=1.10,Lu=50-0-0;Min. flatroofsnow loadgoverns. Rain surchargeapplied toallexposed surfaceswith slopesless than0.500/12inaccordance with IBC 1608.3.4. 5)Unbalanced snow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Provideadequatedrainage toprevent waterponding. 8)Allplatesare2x4MT20unlessotherwiseindicated. 9)Gablerequires continuousbottom chordbearing. 10)Truss tobe fullysheathed fromone faceor securelybracedagainst lateralmovement(i.e.diagonalweb). 11)Gable studs spacedat2-0-0oc. 12)This trusshasbeendesigned fora10.0psfbottom chordlive loadnonconcurrent withanyother liveloads. Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE01 2 12005540-12T PiggybackBaseSupported Gable Job Reference(optional) Run:8.42S8.40Apr72020 Print:8.400SApr72020MiTek Industries,Inc.WedSep0216:36:20 Page: 1 ID:FY5BU?gX1h_f0zMRSujVyTyhiGr-ioTr1J443JjehKQy_9i3KVqHez2?78mx4lTLCyyhdWv Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 13)Providemechanical connection(byothers)of trusstobearingplate capableof withstanding100 lbupliftat joint(s)55,54,53,52,51,50,49,46,45,44,43,42,40,39,38,37, 36,35,34except(jt=lb)57=181,32=168,56=201,33=196. 14)This truss isdesigned inaccordance withthe2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 15)Graphicalpurlinrepresentationdoesnotdepictthesizeor theorientationof thepurlinalongthetopand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE01 2 12005540-12T PiggybackBaseSupportedGable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:20 Page: 2 ID:FY5BU?gX1h_f0zMRSujVyTyhiGr-ioTr1J443JjehKQy_9i3KVqHez2?78mx4lTLCyyhdWv DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 31 262524 2322 21 2019 18 17 16 15141213 3 12 4 11 5 6 7 89 10 T2 T1 T3 T4 T5 T6 W1 W15 B1 B3B1B2 W7W8 W9 W8W9 W8W7 W10 W2 W14 W11 W12 W13W3W4 W5W6 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9 ST10 ST11 ST12 Scale=1:92.4 Plate Offsets(X,Y):[6:0-4-0,0-2-8], [10:0-4-0,0-2-8], [17:0-3-8,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate GripDOL 1.15 TC 0.99 Vert(LL)-0.1421-23>999360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.62 Vert(CT)-0.3020-21>999240 TCDL 10.0 RepStress Incr YES WB 0.81 Horz(CT)0.0916n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:389 lbFT=20% LUMBER TOP CHORD2x4SPFNo.2 BOT CHORD2x4SPFNo.2 WEBS 2x4SPFNo.2*Except*W1,W15:2x6SPF No.2,W2,W14,W13,W3:2x4 SPFStud OTHERS 2x4SPFStud*Except*ST9,ST12:2x4SPF No.2 BRACING TOPCHORD Structuralwood sheathingdirectlyappliedor3-4-2ocpurlins, exceptend verticals,and2-0-0ocpurlins(2-2-0max.):6-10. BOTCHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing,Except: 6-0-0ocbracing:27-28,26-27. WEBS 1 Rowatmidpt 6-24,6-23,7-23,9-23,9-21,10-21, 11-20,11-18,4-28,5-26 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS Allbearings6-10-0.except16=0-6-0,27=0-3-8 (lb)-MaxHoriz31=-250(LC14) MaxUpliftAlluplift100(lb)or lessatjoint(s)except16=-364(LC17), 28=-556(LC13),31=-385(LC57) MaxGravAllreactions250(lb)or lessatjoint(s)29,30,31except 16=1922(LC2),27=410(LC7),28=2399(LC2) FORCES (lb)-Max.Comp./Max.Ten.-All forces250(lb)or lessexcept whenshown. TOP CHORD 2-3=-114/521,3-51=-100/527,51-52=-97/536,52-53=-90/557,4-53=-87/573,4-54=-981/285,5-54=-916/309, 5-6=-1354/431,6-7=-1906/531,7-55=-1906/531,8-55=-1906/531,8-56=-1906/531,9-56=-1906/531,9-10=-2131/574, 10-11=-2133/580,11-57=-2161/556,57-58=-2226/543,12-58=-2302/533,12-59=-1974/456,13-59=-2027/445, 13-14=-2117/443,2-31=-97/399,14-16=-1863/457 BOT CHORD 27-28=-466/243,26-27=-466/243,25-26=-173/819,24-25=-173/819,23-24=-216/1206,22-23=-328/2131, 21-22=-328/2131,20-21=-234/1872,19-20=-312/1991,18-19=-312/1991,17-18=-324/1821 WEBS 6-24=-878/226,6-23=-298/1344,7-23=-643/239,9-23=-491/120,9-21=-283/270,10-21=-188/498,10-20=-141/542, 11-20=-502/249,2-28=-553/243,14-17=-302/1884,12-18=-74/341,12-17=-587/179,4-28=-2309/547,4-26=-314/1870, 5-26=-1296/271,5-24=-185/1061 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to4-6-7, Interior(1)4-6-7 to15-10-0,Exterior(2R)15-10-0 to23-6-3, Interior(1)23-6-3 to36-6-0,Exterior(2R)36-6-0 to44-2-3, Interior(1)44-2-3 to 55-2-12zone; cantileverleftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRSforreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)Trussdesigned for wind loads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandardIndustry GableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns.Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 5)Unbalanced snow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminroof liveloadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Provideadequatedrainage toprevent waterponding. 8)Allplatesare2x4MT20unlessotherwise indicated. 9)Gable studs spacedat2-0-0oc. Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE02 2 12005540-12T PiggybackBaseStructural Gable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTekIndustries,Inc.WedSep0216:36:21 Page: 1 ID:Nv_?pw3m5YmqpE3bsbzDw1yhglW-A_1DEf5ipdrVJU?8YsDItjMHvNH1sRr4JPCukPyhdWu Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyotherliveloads. 11)Providemechanical connection(byothers)of trusstobearingplate capableof withstanding385 lbupliftat joint31,556 lbupliftat joint28and364 lbupliftat joint16. 12)This truss isdesigned inaccordance withthe2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 13)Graphicalpurlinrepresentationdoesnotdepictthesizeor theorientationof thepurlinalongthetopand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE02 2 12005540-12T PiggybackBaseStructuralGable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:21 Page: 2 ID:Nv_?pw3m5YmqpE3bsbzDw1yhglW-A_1DEf5ipdrVJU?8YsDItjMHvNH1sRr4JPCukPyhdWu DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 65 36 35341332323431 5 30 6 29 7 28 8 27 9 26 10 25 1112131415161718192021222324 W1 T2 T1 T3 T4 T5 T6 W2 B1 B1B1B2 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8ST8ST8ST8ST8ST8ST8ST8ST8ST8ST8 ST9 ST10 ST11 ST12 ST13 ST14 ST15 ST16 Scale=1:92.4 Plate Offsets(X,Y):[11:0-4-8,0-2-12], [20:0-2-12,0-1-8], [24:0-3-0,0-2-0], [57:0-3-0,0-3-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate GripDOL 1.15 TC 0.23 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.21 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.17 Horz(CT)0.0136n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:395 lbFT=20% LUMBER TOP CHORD2x4SPFNo.2 BOT CHORD2x4SPFNo.2 WEBS 2x6SPFNo.2 OTHERS 2x4SPFNo.2*Except*ST1,ST2,ST3,ST13,ST14,ST15,ST16:2x4SPF Stud BRACING TOPCHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins, exceptend verticals,and2-0-0ocpurlins(6-0-0max.):11-24. BOTCHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. WEBS 1 Rowatmidpt 8-60,9-59,10-58,12-57,13-56, 14-55,15-54,16-52,17-51,18-50, 19-49,21-48,22-47,23-46,25-45, 26-43,27-42 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS Allbearings54-4-0. (lb)-MaxHoriz65=-250(LC14) MaxUpliftAlluplift100(lb)or lessatjoint(s)38,39,40,41,42,43,45, 47,48,49,50,51,52,54,55,56,58,59,60,61,62,63except 36=-200(LC13),37=-261(LC12),64=-180(LC13),65=-170 (LC12) MaxGravAllreactions250(lb)or lessatjoint(s)38,39,40,41,42,43, 45,46,47,48,49,50,51,52,54,55,56,57,58,59,60,61,62, 63,65except36=277(LC30),37=282(LC31),64=263(LC 30) FORCES (lb)-Max.Comp./Max.Ten.-All forces250(lb)or lessexcept whenshown. TOP CHORD 6-7=-102/265,7-8=-121/317,8-9=-139/369,9-10=-158/425,10-11=-172/461,11-12=-155/437,12-13=-155/435, 13-14=-155/435,14-15=-155/435,15-16=-155/435,16-17=-155/435,17-18=-155/435,18-19=-155/435,19-20=-155/435, 20-21=-155/435,21-22=-155/435,22-23=-155/435,23-24=-155/435,24-25=-171/459,25-26=-159/425,26-27=-139/368, 27-28=-121/317,28-29=-103/264 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneandC-C Corner(3E)-0-10-12 to4-6-7,Exterior(2N)4-6-7 to15-10-0, Corner(3R)15-10-0 to21-3-3,Exterior(2N)21-3-3 to36-6-0,Corner(3R)36-6-0 to42-1-12,Exterior(2N)42-1-12to 55-2-12zone; cantileverleftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRSforreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)Trussdesigned for wind loads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandardIndustry GableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns.Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 5)Unbalanced snow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminroof liveloadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Provideadequatedrainage toprevent waterponding. 8)Allplatesare2x4MT20unlessotherwise indicated. 9)Gablerequires continuousbottom chordbearing. 10)Truss tobe fully sheathed fromone faceor securelybracedagainstlateralmovement(i.e.diagonal web). Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE03 2 12005540-12T PiggybackBaseSupported Gable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTekIndustries,Inc.WedSep0216:36:22 Page: 1 ID:q4dO5mbwKGYPr6NjzwCilcyhggy-fAabR?6LawzMweaK5akXQwveXnjhb15EY3yRGryhdWt Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 11)Gablestuds spacedat2-0-0oc. 12)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyotherliveloads. 13)Providemechanical connection(byothers)of trusstobearingplate capableof withstanding100 lbupliftat joint(s)63,62,61,60,59,58,56,55,54,52,51,50,49,48,47,45, 43,42,41,40,39,38except(jt=lb)65=169,36=199,64=179,37=260. 14)This truss isdesigned inaccordance withthe2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 15)Graphicalpurlinrepresentationdoesnotdepictthesizeor theorientationof thepurlinalongthetopand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE03 2 12005540-12T PiggybackBaseSupportedGable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:22 Page: 2 ID:q4dO5mbwKGYPr6NjzwCilcyhggy-fAabR?6LawzMweaK5akXQwveXnjhb15EY3yRGryhdWt DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 55 36 67 35341332323314305 296 287 278 269 2510 1112131415161718192021222324 W1 T2 T1 T3 T4 T5 T6 W1B1B2 B3 B4 B5B1 W2 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8ST8 ST9ST9ST9ST9ST9ST9ST9ST9 ST10 ST7 ST6 ST5 ST4 ST3 ST2 ST1 Scale=1:92.2 Plate Offsets(X,Y):[11:0-3-0,0-2-0], [24:0-3-0,0-2-0], [56:0-2-8,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate GripDOL 1.15 TC 0.19 Vert(LL)0.0014>999360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.18 Vert(CT)0.0014-56>999240 TCDL 10.0 RepStress Incr YES WB 0.17 Horz(CT)0.0136n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:392 lbFT=20% LUMBER TOP CHORD2x4SPFNo.2 BOT CHORD2x4SPFNo.2 WEBS 2x6SPFNo.2*Except*W2:2x4SPFNo.2 OTHERS 2x4SPFNo.2*Except*ST1,ST2,ST3,ST4:2x4SPFStud BRACING TOPCHORD Structural wood sheathingdirectlyappliedor6-0-0ocpurlins, exceptend verticals,and2-0-0ocpurlins(10-0-0max.):11-24. BOTCHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing.Except: 1Rowatmidpt14-56 WEBS 1 Rowatmidpt 9-60,10-59,12-58,13-57,15-54, 16-53,17-52,18-51,19-50,21-49, 22-48,23-46,25-44,26-43,27-42 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS Allbearings33-6-0.except67=18-9-14,66=18-9-14,64=18-9-14, 63=18-9-14,62=18-9-14,61=18-9-14,60=18-9-14,59=18-9-14, 58=18-9-14,57=18-9-14 (lb)-MaxHoriz67=-235(LC12) MaxUpliftAlluplift100(lb)or lessatjoint(s)38,39,40,41,42,43,44, 48,49,50,51,52,53,54,55,57,59,60,61,62,63,64except 36=-226(LC13),37=-324(LC12),66=-311(LC13),67=-359 (LC12) MaxGravAllreactions250(lb)or lessatjoint(s)38,39,40,41,42,43, 44,46,48,49,50,51,52,53,54,55,57,58,59,60,61,62,63, 64except36=302(LC14),37=300(LC15),66=386(LC14), 67=335(LC15) FORCES (lb)-Max.Comp./Max.Ten.-All forces250(lb)or lessexcept whenshown. TOP CHORD 7-8=-94/286,8-9=-112/337,9-10=-131/394,10-11=-145/430,11-12=-130/408,12-13=-130/408,13-14=-130/408, 14-15=-137/414,15-16=-137/414,16-17=-137/414,17-18=-137/414,18-19=-137/414,19-20=-137/414,20-21=-137/414, 21-22=-137/414,22-23=-137/414,23-24=-137/414,24-25=-152/436,25-26=-139/400,26-27=-119/344,27-28=-101/292 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneandC-C Corner(3E)-0-10-12 to4-4-1,Exterior(2N)4-4-1 to14-10-0, Corner(3R)14-10-0 to20-0-13,Exterior(2N)20-0-13 to35-6-0,Corner(3R)35-6-0 to40-8-13,Exterior(2N)40-8-13 to53-2-12zone; cantileverleftandrightexposed ; endvertical leftandrightexposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plate grip DOL=1.60 3)Trussdesigned for wind loads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard Industry GableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns.Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 5)Unbalanced snow loadshavebeen consideredfor thisdesign. 6)This trusshasbeendesigned forgreaterofminroof liveloadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Provideadequatedrainage toprevent waterponding. 8)Allplatesare2x4MT20unlessotherwise indicated. 9)Truss tobe fully sheathed fromone faceor securelybracedagainstlateralmovement(i.e.diagonal web). 10)Gable studs spacedat2-0-0oc. Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE04 4 12005540-12T PiggybackBaseSupported Gable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTekIndustries,Inc.WedSep0216:36:23 Page: 1 ID:9?RtYn2ak2O9RzXkno?qKXyhgpP-7N8zfL7zLE6DYo9XfHFmy8SqwA4NKULNnjh?pHyhdWs Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 11)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyotherliveloads. 12)Providemechanical connection(byothers)of trusstobearingplate capableof withstanding100 lbupliftat joint(s)55,64,63,62,61,60,59,57,54,53,52,51,50,49,48,44, 43,42,41,40,39,38except(jt=lb)67=358,36=225,66=311,37=324. 13)This truss isdesigned inaccordance withthe2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 14)Graphicalpurlinrepresentationdoesnotdepictthesizeor theorientationof thepurlinalongthetopand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE04 4 12005540-12T PiggybackBaseSupportedGable Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:23 Page: 2 ID:9?RtYn2ak2O9RzXkno?qKXyhgpP-7N8zfL7zLE6DYo9XfHFmy8SqwA4NKULNnjh?pHyhdWs DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. MT18HS3x10 5x6 4x4 5 4 1 2 3 W1 T1 W2 B1 Scale = 1:32.5 Plate Offsets(X,Y):[4:Edge,0-3-8], [5:0-3-8,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.77 Vert(LL)n/a -n/a999 MT18HS 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.34 Vert(CT)n/a -n/a999 MT20 197/144 TCDL 10.0 RepStress Incr YES WB 0.00 Horz(CT)n/a -n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:13 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor1-6-0ocpurlins, exceptend verticals. BOT CHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)4=20/1-6-0,(min.0-1-8),5=119/1-6-0,(min.0-1-8) Max Horiz5=101(LC13) Max Uplift4=-177(LC13),5=-83(LC14) Max Grav4=145(LC14),5=162(LC31) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. TOP CHORD 3-4=-123/308 NOTES 1)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Corner(3E)zone; cantilever leftexposed ; end vertical leftexposed;C-Cformembersand forces&MWFRS forreactionsshown;Lumber DOL=1.60plategrip DOL=1.60 2)Trussdesigned forwind loads in theplaneof the trussonly.Forstudsexposed towind(normal tothe face), seeStandard Industry GableEndDetailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 6)AllplatesareMT20platesunlessotherwise indicated. 7)Gablerequires continuousbottom chordbearing. 8)Truss tobefully sheathed fromone faceorsecurelybracedagainst lateralmovement(i.e.diagonal web). 9)Gable studs spacedat2-0-0oc. 10)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 11)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding83 lbupliftat joint5and177 lbupliftat joint4. 12)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE05 2 12005540-12T MonopitchSupported Gable Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:25 Page: 1 ID:kX3lx3a2TZ1ToDCIdApDNoyhgrJ-3lGk418DtrMxn5JvniHE1YX0M_jLnQUgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 4x4 4x4 3x4 3x4 5 4 1 2 3 W1 T1 W2 B1 Scale = 1:27.3 Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.46 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.21 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.00 Horz(CT)n/a -n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:10 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor1-6-0ocpurlins, exceptend verticals. BOT CHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)4=20/1-6-0,(min.0-1-8),5=119/1-6-0,(min.0-1-8) Max Horiz5=79(LC13) Max Uplift4=-102(LC13),5=-19(LC12) Max Grav4=79(LC14),5=159(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. NOTES 1)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Corner(3E)zone; cantilever leftexposed ; end vertical leftexposed;C-Cformembersand forces&MWFRS forreactionsshown;Lumber DOL=1.60plategrip DOL=1.60 2)Trussdesigned forwind loads in theplaneof the trussonly.Forstudsexposed towind(normal tothe face), seeStandard Industry GableEndDetailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 6)Gablerequires continuousbottom chordbearing. 7)Truss tobefully sheathed fromone faceorsecurelybracedagainst lateralmovement(i.e.diagonal web). 8)Gable studs spacedat2-0-0oc. 9)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 10)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding19 lbupliftat joint5and102 lbupliftat joint4. 11)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 GE06 2 12005540-12T MonopitchSupported Gable Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:25 Page: 1 ID:1cSzreSmpUmuchRN24dtzhyhgrT-3lGk418DtrMxn5JvniHE1YX5B_lOnQUgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3 12 3x4 3x4 3x4 5 1 2 3 4 T1 W1 B1 HW1 Scale = 1:25.1 Plate Offsets(X,Y):[2:0-2-14,0-0-11], [5:Edge,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.38 Vert(LL)0.105-8>567360 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.38 Vert(CT)0.095-8>658240 TCDL 10.0 RepStress Incr YES WB 0.00 Horz(CT)-0.02 2n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:16 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud SLIDER Left2x4SPFStud--1-6-0 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor4-11-0ocpurlins, exceptend verticals. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS (lb/size)2=219/0-4-0,(min.0-1-8),5=165/0-1-8,(min.0-1-8) Max Horiz2=63(LC12) Max Uplift2=-136(LC12),5=-109(LC12) Max Grav2=287(LC23),5=212(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. TOP CHORD 2-3=-184/401 NOTES 1)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to2-1-4, Interior(1)2-1-4 to4-9-4 zone; cantileverleftexposed ; end vertical leftexposed;porch leftandrightexposed;C-C formembersand forces& MWFRS forreactionsshown;Lumber DOL=1.60plategrip DOL=1.60 2)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10;Min. flatroof snow loadgoverns. 3)Unbalanced snow loadshavebeen considered for thisdesign. 4)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 5)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 6)Bearingat joint(s)5considersparalleltograin valueusingANSI/TPI1angle tograin formula.Buildingdesigner should verifycapacityofbearing surface. 7)Providemechanical connection(byothers)of truss tobearingplateat joint(s)5. 8)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding136 lbupliftatjoint2and109 lbupliftat joint5. 9)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 J01 2 12005540-12T Jack-Closed Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:25 Page: 1 ID:KMJ8HNWl2?eTk63JJeYq0wyhiMD-3lGk418DtrMxn5JvniHE1YX7S_jknQUgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3 12 1.5x4 =5x6 7 6 1 2 3 54 T1 T2 W2 B1 W1 HW1 Scale = 1:28.5 Plate Offsets(X,Y):[2:0-4-10,Edge], [6:Edge,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.41 Vert(LL)0.127-10>498360 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.45 Vert(CT)0.107-10>584240 TCDL 10.0 RepStress Incr YES WB 0.07 Horz(CT)-0.03 2n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:17 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud SLIDER Left2x4SPFStud--1-6-0 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor4-11-0ocpurlins, exceptend verticals,and2-0-0ocpurlins:4-5. BOT CHORD Rigid ceilingdirectlyappliedor6-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS (lb/size)2=219/0-4-0,(min.0-1-8),6=165/0-1-8,(min.0-1-8) Max Horiz2=56(LC12) Max Uplift2=-138(LC12),6=-106(LC12) Max Grav2=306(LC38),6=224(LC38) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. TOP CHORD 2-3=-196/478 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to2-1-4, Interior(1)2-1-4 to4-6-8,Exterior(2E)4-6-8 to4-9-4 zone; cantilever leftexposed ; end vertical leftexposed;porchleftandrightexposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns. Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 6)Provideadequatedrainage topreventwaterponding. 7)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 8)Bearingat joint(s)6considersparalleltograin valueusingANSI/TPI1angle tograin formula.Buildingdesigner should verifycapacityofbearing surface. 9)Providemechanical connection(byothers)of truss tobearingplateat joint(s)6. 10)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding138 lbupliftatjoint2and106 lbupliftat joint6. 11)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. 12)Graphicalpurlinrepresentationdoesnotdepictthe sizeor theorientationof thepurlinalong the topand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 J02 2 12005540-12T Jack-Closed Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:25 Page: 1 ID:_xZ5MIsxDvILjZnuVEZdh2yhiLm-3lGk418DtrMxn5JvniHE1YX6__henPOgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 3x4 5 1 2 3 T1 B1 HW1 Scale = 1:20.6 Plate Offsets(X,Y):[2:0-1-12,0-0-11] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.12 Vert(LL)0.015-8>999360 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.08 Vert(CT)0.005-8>999240 TCDL 10.0 RepStress Incr YES WB 0.00 Horz(CT)0.00 4n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:9 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 SLIDER Left2x4SPFStud--1-6-0 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor2-6-8ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. REACTIONS (lb/size)2=141/0-4-0,(min.0-1-8),4=51/Mechanical,(min.0-1-8), 5=29/Mechanical,(min.0-1-8) Max Horiz2=39(LC12) Max Uplift2=-93(LC12),4=-36(LC12),5=-18(LC12) Max Grav2=180(LC23),4=66(LC23),5=40(LC7) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. NOTES 1)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to2-1-4, Interior(1)2-1-4 to2-5-12zone; cantilever leftexposed ; end vertical leftexposed;porchleftandrightexposed;C-Cformembersand forces& MWFRS forreactionsshown;Lumber DOL=1.60plategrip DOL=1.60 2)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10;Min. flatroof snow loadgoverns. 3)Unbalanced snow loadshavebeen considered for thisdesign. 4)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 5)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 6)Refer togirder(s) for truss to truss connections. 7)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding36 lbupliftat joint4,93 lbupliftatjoint2and18 lbupliftat joint5. 8)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 J03 4 12005540-12T Jack-Open Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:25 Page: 1 ID:pSZVTPz0nslR8YFNLriztEyhiKL-3lGk418DtrMxn5JvniHE1YXBW_nQnQUgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. =3x4 1.5x4 1.5x4 =4x4 1.5x4 1.5x4 1.5x4 =3x4 1 7 10 9 8 62 53 4 T1 T1 B1 ST2 ST1 ST1 Scale =1:27.3 Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.11 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.09 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.06 Horz(CT)0.006n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:33 lbFT = 20% LUMBER TOPCHORD2x4SPF No.2 BOTCHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS Allbearings10-4-14. (lb)-MaxHoriz2=53(LC20),11=53(LC20) MaxUpliftAlluplift100(lb)or lessatjoint(s)2,6,11,15except8=-112 (LC17),10=-113(LC16) Max GravAllreactions250(lb)or lessat joint(s)2,6,9,11,15except 8=332(LC24),10=332(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhenshown. NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneand C-C Exterior(2E)0-4-3 to3-4-3, Interior(1)3-4-3 to6-2-0,Exterior(2R)6-2-0 to9-2-0, Interior(1)9-2-0 to11-11-13 zone; cantilever leftandrightexposed ; end vertical leftandright exposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategripDOL=1.60 3)Trussdesigned for windloads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard IndustryGableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough Cat C; PartiallyExp.; Ce=1.0; Cs=1.00;Ct=1.10 5)Unbalancedsnow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminrooflive loadof12.0psfor2.00 times flatroof loadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Gablerequires continuousbottom chordbearing. 8)Gable studsspacedat2-0-0oc. 9)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 10)Providemechanical connection(byothers)of truss tobearingplate capableof withstanding100 lbupliftatjoint(s)2,6,2,6except(jt=lb)10=112,8=112. 11)This truss isdesigned inaccordance with the2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 12)SeeStandard IndustryPiggybackTruss Connection Detail for Connection tobase trussasapplicable,or consultqualifiedbuildingdesigner. LOAD CASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 P01 2 12005540-12T Piggyback Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400 SApr72020MiTek Industries,Inc.Wed Sep0216:36:25 Page: 1 ID:Zy36YSSYUZzmbt6_qs2p4nyhiSl-3lGk418DtrMxn5JvniHE1YXBg_nFnQZgE0A5tAyhdWq DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 6 12 =3x5 =4x4 1.5x4 =3x5 1 5 6 42 3 T1 T1 B1 ST1 Scale =1:27.3 Plate Offsets(X,Y):[2:0-2-8,Edge], [4:0-2-8,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.40 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.39 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.04 Horz(CT)0.002n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:30 lbFT = 20% LUMBER TOPCHORD2x4SPF No.2 BOTCHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS Allbearings10-4-14. (lb)-MaxHoriz2=53(LC20),7=53(LC20) MaxUpliftAlluplift100(lb)or lessatjoint(s)2,4,6,7,11 Max GravAllreactions250(lb)or lessat joint(s)except2=298(LC23), 4=298(LC24),6=369(LC2),7=298(LC23),11=298(LC24) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhenshown. NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneand C-C Exterior(2E)0-4-3 to3-4-3, Interior(1)3-4-3 to6-2-0,Exterior(2R)6-2-0 to9-2-0, Interior(1)9-2-0 to11-11-13 zone; cantilever leftandrightexposed ; end vertical leftandright exposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategripDOL=1.60 3)Trussdesigned for windloads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard IndustryGableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough Cat C; PartiallyExp.; Ce=1.0; Cs=1.00;Ct=1.10 5)Unbalancedsnow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminrooflive loadof12.0psfor2.00 times flatroof loadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Gablerequires continuousbottom chordbearing. 8)Gable studsspacedat4-0-0oc. 9)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 10)Providemechanical connection(byothers)of truss tobearingplate capableof withstanding100 lbupliftatjoint(s)2,4,6,2,4. 11)This truss isdesigned inaccordance with the2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 12)SeeStandard IndustryPiggybackTruss Connection Detail for Connection tobase trussasapplicable,or consultqualifiedbuildingdesigner. LOAD CASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 P02 6 12005540-12T Piggyback Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400 SApr72020MiTek Industries,Inc.Wed Sep0216:36:26 Page: 1 ID:Htfuetaq7eEMoPtvPyD9UuyhiSb-Xyq6HN9re9UoPFu6KQoTam3HtO1pWt7qTgwfQcyhdWp DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 =3x8 =3x8 1 7 14 13 12 11 10 9 8 62 53 4 T1 T1 B1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 Scale =1:39.8 Plate Offsets(X,Y):[2:0-4-12,0-1-8], [6:0-4-12,0-1-8], [11:0-3-0,0-3-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.44 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.47 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.15 Horz(CT)0.006n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:70 lbFT = 20% LUMBER TOPCHORD2x4SPF No.2 BOTCHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS Allbearings18-8-14. (lb)-MaxHoriz2=91(LC20),19=91(LC20) MaxUpliftAlluplift100(lb)or lessatjoint(s)2,6,8,9,13,14,19,23 except10=-270(LC17),11=-121(LC2),12=-271(LC16) Max GravAllreactions250(lb)or lessat joint(s)2,6,8,9,11,13,14,19, 23except10=516(LC24),12=516(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhenshown. WEBS 3-12=-454/298,5-10=-454/298 NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneand C-C Exterior(2E)0-4-3 to3-4-3, Interior(1)3-4-3 to10-4-0,Exterior(2R)10-4-0 to13-4-0, Interior(1)13-4-0 to20-3-13zone; cantilever leftandrightexposed ; end verticalleftand rightexposed;C-Cformembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)Trussdesigned for windloads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard IndustryGableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough Cat C; PartiallyExp.; Ce=1.0; Cs=1.00;Ct=1.10 5)Unbalancedsnow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminrooflive loadof12.0psfor2.00 times flatroof loadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Allplatesare1.5x4MT20unlessotherwise indicated. 8)Gablerequires continuousbottom chordbearing. 9)Gable studsspacedat2-0-0oc. 10)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 11)Providemechanical connection(byothers)of truss tobearingplate capableof withstanding100 lbupliftatjoint(s)2,6,13,14,9,8,2,6except(jt=lb)11=121,12=270, 10=269. 12)This truss isdesigned inaccordance with the2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 13)SeeStandard IndustryPiggybackTruss Connection Detail for Connection tobase trussasapplicable,or consultqualifiedbuildingdesigner. LOAD CASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 P03 8 12005540-12T Piggyback Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400 SApr72020MiTek Industries,Inc.Wed Sep0216:36:26 Page: 1 ID:_?jG2CAFT?Ol60DIzAuAWxyhinn-Xyq6HN9re9UoPFu6KQoTam3HGO0ZWrOqTgwfQcyhdWp DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. =3x4 =3x4 1 7 11 10 9 8 62 53 4 T1 T1 B1 B2 ST2 ST1 ST1 Scale =1:39.8 Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.27 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.21 Vert(CT)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.09 Horz(CT)0.006n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:58 lbFT = 20% LUMBER TOPCHORD2x4SPF No.2 BOTCHORD2x4SPF No.2 OTHERS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor6-0-0ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide.REACTIONS Allbearings18-8-14. (lb)-MaxHoriz2=91(LC20),12=91(LC20) MaxUpliftAlluplift100(lb)or lessatjoint(s)2,6,12,15except8=-195 (LC17),11=-196(LC16) Max GravAllreactions250(lb)or lessat joint(s)2,6,9,12,15except 8=493(LC24),11=493(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhenshown. WEBS 3-11=-362/228,5-8=-362/228 NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneand C-C Exterior(2E)0-4-3 to3-4-3, Interior(1)3-4-3 to10-4-0,Exterior(2R)10-4-0 to13-4-0, Interior(1)13-4-0 to20-3-13zone; cantilever leftandrightexposed ; end verticalleftand rightexposed;C-Cformembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)Trussdesigned for windloads in theplaneof the trussonly.For studsexposed to wind(normal tothe face), seeStandard IndustryGableEnd Detailsasapplicable,or consult qualifiedbuildingdesignerasperANSI/TPI1. 4)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough Cat C; PartiallyExp.; Ce=1.0; Cs=1.00;Ct=1.10 5)Unbalancedsnow loadshavebeen considered for thisdesign. 6)This trusshasbeendesigned forgreaterofminrooflive loadof12.0psfor2.00 times flatroof loadof15.4psfonoverhangsnon-concurrent withother live loads. 7)Gablerequires continuousbottom chordbearing. 8)Gable studsspacedat4-0-0oc. 9)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 10)Providemechanical connection(byothers)of truss tobearingplate capableof withstanding100 lbupliftatjoint(s)2,6,2,6except(jt=lb)11=195,8=195. 11)This truss isdesigned inaccordance with the2018International Residential Code sectionsR502.11.1and R802.10.2andreferenced standardANSI/TPI1. 12)SeeStandard IndustryPiggybackTruss Connection Detail for Connection tobase trussasapplicable,or consultqualifiedbuildingdesigner. LOAD CASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 P04 32 12005540-12T Piggyback Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400 SApr72020MiTek Industries,Inc.Wed Sep0216:36:27 Page: 1 ID:ZDaY7GfDUn6M8UvFJwroGMyhiSU-?8OUVjATPTcf1PTIu7Ki7zcUeoQsFJazhKfCy3yhdWo DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 22 21 2019 18 1716 15 14 1 13212 113 4 10 5 9 6 7 8 T2 T1 T3 T2 T1 W1 W1 B1 B1B1 W3 W4 W5 W6W7 W8 W7W6 W5 W4 W3W2 W2 Scale = 1:80.8 Plate Offsets(X,Y):[6:0-3-0,0-2-0], [8:0-3-0,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate Grip DOL 1.15 TC 0.74 Vert(LL)-0.1521-22>999360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.80 Vert(CT)-0.3319-21>999240 TCDL 10.0 RepStress Incr YES WB 0.78 Horz(CT)0.1514n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:260 lbFT = 20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPF No.2*Except*W3,W2:2x4SPFStud,W1:2x6SPFNo.2 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor2-5-10ocpurlins, exceptend verticals,and2-0-0ocpurlins(3-4-5max.):6-8. BOT CHORD Rigid ceilingdirectlyappliedor9-2-11ocbracing. WEBS 1 Rowatmidpt 5-21,5-19,7-18,9-17,9-15,4-22, 10-14 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordancewithStabilizer Installationguide. REACTIONS (lb/size)14=1802/0-6-0,(min.0-3-3),22=1802/0-6-0,(min.0-3-3) Max Horiz22=220(LC15) Max Uplift14=-368(LC17),22=-368(LC16) Max Grav14=2039(LC41),22=2039(LC41) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)or lessexceptwhen shown. TOP CHORD 4-24=-2489/518,24-25=-2377/530,25-26=-2349/533,5-26=-2259/547,5-6=-2292/604,6-27=-2038/607,7-27=-2038/607, 7-28=-2038/607,8-28=-2038/607,8-9=-2292/604,9-29=-2259/547,29-30=-2349/534,30-31=-2377/530, 10-31=-2489/519 BOT CHORD 21-22=-396/1819,20-21=-382/2184,19-20=-382/2184,18-19=-277/1919,17-18=-264/1919,16-17=-349/2184, 15-16=-349/2184,14-15=-345/1819 WEBS 4-21=-17/476,5-19=-455/268,6-19=-146/526,6-18=-172/456,7-18=-628/232,8-18=-172/456,8-17=-146/526, 9-17=-455/268,10-15=-17/476,4-22=-2520/474,10-14=-2520/474 NOTES 1)Unbalancedroof liveloadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneand C-C Exterior(2E)-0-10-12 to3-10-14, Interior(1)3-10-14 to17-10-0,Exterior(2R)17-10-0 to24-7-7,Interior(1)24-7-7 to30-2-0,Exterior(2R)30-2-0 to36-11-7, Interior(1)36-11-7 to48-10-12 zone; cantilever leftandrightexposed ; endvertical leftandrightexposed;C-C formembersand forces&MWFRS forreactionsshown;LumberDOL=1.60plate grip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:Lum DOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(LumDOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0;Cs=1.00;Ct=1.10,Lu=50-0-0;Min. flatroofsnow loadgoverns. Rain surchargeapplied toallexposed surfaceswith slopesless than0.500/12inaccordance with IBC 1608.3.4. 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 6)Provideadequatedrainage toprevent waterponding. 7)This trusshasbeendesigned fora10.0psfbottom chordlive loadnonconcurrent withanyother liveloads. 8)Providemechanical connection(byothers)of truss tobearingplate capableof withstanding368lbupliftat joint22and368lbupliftatjoint14. 9)This truss is designed inaccordance with the2018 International Residential Code sections R502.11.1andR802.10.2andreferenced standardANSI/TPI1. 10)Graphicalpurlinrepresentationdoesnotdepict the sizeor theorientationof thepurlinalong the topand/orbottom chord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T01 6 12005540-12T PiggybackBase Job Reference(optional) Run:8.42S8.40Apr72020 Print:8.400SApr72020MiTek Industries,Inc.WedSep0216:36:27 Page: 1 ID:bmWWA1TsJsPF34obI7qv8TyhiBy-?8OUVjATPTcf1PTIu7Ki7zcNIoHdF8pzhKfCy3yhdWo DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 100.00 lb/ft70.00 lb/ft to0.00 lb/ft 27 26 25 2423 2221 20 1918 17 16 15141213 3 12 4 11 5 6 7 89 10 T2 T1 T3 T4 T5 T6 W1 W15 B1 B3B1B2 W7 W8 W9 W8 W9 W8W10 W11 W14 W2 W6 W3W4 W5 W12 W13 Scale=1:92.4 Plate Offsets(X,Y):[2:0-2-12,0-2-0], [6:0-6-0,0-2-8], [10:0-4-0,0-2-8], [12:0-3-8,0-1-8], [14:0-3-1,0-2-0], [26:0-3-8,0-3-0] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate GripDOL 1.15 TC 0.93 Vert(LL)-0.2220-22>999360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.99 Vert(CT)-0.4720-22>999240 TCDL 10.0 RepStress Incr NO WB 0.91 Horz(CT)0.2316n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:320 lbFT=20% LUMBER TOP CHORD2x6SPFNo.2*Except*T3:2x4SPF1650F1.5E,T5,T6:2x4SPF No.2, T4:2x4SPF2100F1.8E BOT CHORD2x4SPFNo.2 WEBS 2x4SPFNo.2*Except*W1,W15:2x6SPF No.2,W3,W4,W13:2x4SPF Stud BRACING TOPCHORD Structuralwood sheathingdirectlyapplied,exceptend verticals, and2-0-0ocpurlins(2-11-15max.):6-10. BOTCHORD Rigid ceilingdirectlyappliedor6-10-9ocbracing. WEBS 1 Rowatmidpt 7-22,9-20,10-20,11-19,12-16, 4-23,3-26,11-17 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)16=2297/0-6-0,(min.0-3-14),27=3323/0-6-0,(min.0-5-7) MaxHoriz27=-247(LC14) MaxUplift16=-455(LC17),27=-715(LC16) MaxGrav16=2453(LC2),27=3462(LC2) FORCES (lb)-Max.Comp./Max.Ten.-All forces250(lb)or lessexcept whenshown. TOP CHORD 2-3=-2570/621,3-28=-3885/919,28-29=-3831/914,29-30=-3696/893,30-31=-3677/862,4-31=-3427/858,4-5=-3626/894, 5-32=-3349/861,6-32=-3216/851,6-7=-3334/858,7-33=-3334/858,8-33=-3334/858,8-34=-3334/858,9-34=-3334/858, 9-10=-3245/836,10-11=-3062/783,11-35=-2878/712,35-36=-2945/698,12-36=-3021/688,2-27=-3425/824, 14-16=-305/200 BOT CHORD 25-26=-576/2267,24-25=-740/3288,23-24=-740/3288,22-23=-613/2960,21-22=-581/3245,20-21=-581/3245, 19-20=-428/2676,18-19=-493/2736,17-18=-493/2736,16-17=-471/2376 WEBS 6-23=-205/806,6-22=-204/719,7-22=-618/232,9-22=-137/314,9-20=-797/348,10-20=-328/1092,10-19=-118/442, 11-19=-345/243,12-16=-3070/586,2-26=-657/3098,4-23=-883/363,3-26=-2064/503,3-25=-259/1402,4-25=-840/240, 11-17=-389/163,12-17=-66/627 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to4-6-7, Interior(1)4-6-7 to15-10-0,Exterior(2R)15-10-0 to23-6-3, Interior(1)23-6-3 to36-6-0,Exterior(2R)36-6-0 to44-2-3, Interior(1)44-2-3 to 55-2-12zone; cantileverleftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRSforreactions shown;Lumber DOL=1.60plategrip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns.Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof liveloadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 6)Provideadequatedrainage toprevent waterponding. 7)This trusshasbeendesigned fora10.0psfbottom chordlive loadnonconcurrentwithanyother liveloads. 8)Providemechanical connection(byothers)of truss tobearingplate capableofwithstanding715 lbupliftat joint27and455lbupliftat joint16. 9)This truss isdesigned inaccordance with the2018 International ResidentialCode sections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. 10)Graphicalpurlinrepresentationdoesnotdepict the sizeor theorientationof thepurlinalong the topand/orbottomchord. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T02 12 12005540-12T PiggybackBase Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTekIndustries,Inc.WedSep0216:36:28 Page: 1 ID:vmb7e?Oj36xJ8kNTAB4VBbyhi1j-TKysi3B5AmkVeZ2USqrxfB9V4Bau_Z06w_PmUVyhdWn Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 1)Dead +Snow(balanced):LumberIncrease=1.15,PlateIncrease=1.15 UniformLoads(lb/ft) Vert:1-2=-51,2-3=-51,6-32=-51,6-10=-61,10-14=-51,14-15=-51,16-27=-20 TrapezoidalLoads(lb/ft) Vert:3=-221-to-28=-218,28=-218-to-29=-215,29=-215-to-30=-209,30=-209-to-31=-192,31=-192-to-4=-187,4=-187-to-5=-171,5=-171-to-32=-151 Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T02 12 12005540-12T PiggybackBase Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:28 Page: 2 ID:vmb7e?Oj36xJ8kNTAB4VBbyhi1j-TKysi3B5AmkVeZ2USqrxfB9V4Bau_Z06w_PmUVyhdWn DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 612 70.00 lb/ft to0.00 lb/ft100.00 lb/ft 24 23 22 212019 18 17 30 2928 27 26 25 161512 14313 4 125 6 7 8 910 11 T2 T1 T3 T4 T5 T6 W1 W19B1B2 B3 B4 B4B5 W7 W8 W10 W9 W11 W14 W15 W18 W11W12 W13 W2 W3 W6W5 W4 W16 W17 Scale=1:92.2 Plate Offsets(X,Y):[2:0-2-12,0-2-4], [5:0-2-11,Edge], [6:0-6-0,0-2-8], [11:0-4-0,0-2-8], [13:0-3-8,0-1-8], [25:0-3-4,0-3-4], [27:0-3-8,0-1-8], [28:0-3-8,0-3-0], [29:0-1-12,0-1-8], [30:0-2-0,0-0-4] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 Plate GripDOL 1.15 TC 0.74 Vert(LL)-0.227>999360 MT20 197/144 Snow(Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.94 Vert(CT)-0.4322-23>999240 TCDL 10.0 RepStress Incr NO WB 0.84 Horz(CT)0.2117n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight:336 lbFT=20% LUMBER TOP CHORD2x4SPFNo.2*Except*T2,T1:2x6SPFNo.2,T4:2x4SPF1650F1.5E BOT CHORD2x4SPFNo.2 WEBS 2x4SPFNo.2*Except*W1,W19:2x6SPF No.2,W3,W5,W4,W17:2x4 SPFStud BRACING TOPCHORD Structural wood sheathingdirectlyappliedor2-10-1ocpurlins, exceptend verticals,and2-0-0ocpurlins(2-8-5max.):6-11. BOTCHORD Rigid ceilingdirectlyappliedor6-8-14ocbracing.Except: 1Rowatmidpt7-25 WEBS 1 Rowatmidpt 8-23,11-20,12-20,13-17,10-22, 11-22,4-26,12-18 MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)17=2241/0-6-0,(min.0-3-12),30=3260/0-6-0,(min.0-5-5) MaxHoriz30=-232(LC12) MaxUplift17=-443(LC17),30=-700(LC16) MaxGrav17=2388(LC2),30=3389(LC2) FORCES (lb)-Max.Comp./Max.Ten.-All forces250(lb)or lessexcept whenshown. TOP CHORD 2-31=-2799/660,3-31=-2716/663,3-32=-4051/949,32-33=-3945/934,33-34=-3806/916,4-34=-3573/885,4-5=-3703/916, 5-6=-3678/915,6-7=-3362/860,7-35=-3357/859,35-36=-3357/859,8-36=-3357/859,8-9=-3181/823,9-37=-3181/823, 10-37=-3181/823,10-11=-3054/792,11-12=-2843/747,12-38=-2555/657,38-39=-2618/644,13-39=-2690/635, 2-30=-3354/807,15-17=-278/187 BOT CHORD 27-28=-626/2486,26-27=-775/3405,25-26=-657/3080,7-25=-307/117,22-23=-561/3054,21-22=-410/2506, 20-21=-410/2506,19-20=-457/2478,18-19=-457/2478,17-18=-417/2058 WEBS 6-26=-236/851,6-25=-195/752,23-25=-615/3161,8-25=-184/711,8-23=-905/326,11-20=-115/359,12-20=-252/310, 13-17=-2841/547,10-22=-845/346,10-23=-135/367,11-22=-325/1115,2-28=-671/3168,3-28=-1912/476,4-26=-921/357, 4-27=-660/205,3-27=-233/1224,12-18=-511/174,13-18=-83/733 NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; ExpC;Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E)-0-10-12 to4-4-1, Interior(1)4-4-1 to14-10-0,Exterior(2R)14-10-0 to22-2-13, Interior(1)22-2-13 to35-6-0,Exterior(2R)35-6-0 to42-10-13, Interior(1)42-10-13 to53-2-12zone; cantileverleftandrightexposed ; endvertical leftandrightexposed;C-C formembersand forces&MWFRS forreactions shown;Lumber DOL=1.60plate grip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15PlateDOL=1.15);Pg=20.0psf;Pf=20.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10,Lu=50-0-0;Min. flatroof snow loadgoverns.Rain surchargeapplied toallexposed surfaceswith slopes less than0.500/12inaccordancewith IBC 1608.3.4. 4)Unbalanced snow loadshavebeen consideredfor thisdesign. 5)This trusshasbeendesigned forgreaterofminroof liveloadof12.0psfor2.00 times flatroofloadof15.4psfonoverhangsnon-concurrent withother live loads. 6)Provideadequatedrainage toprevent waterponding. 7)This trusshasbeendesigned fora10.0psfbottomchordlive loadnonconcurrentwithanyother liveloads. 8)Providemechanical connection(byothers)of truss tobearingplate capableofwithstanding700 lbupliftat joint30and443lbupliftat joint17. 9)This trussisdesigned inaccordance with the2018 International ResidentialCode sections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T03 20 12005540-12T PiggybackBase Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTekIndustries,Inc.WedSep0216:36:28 Page: 1 ID:bUrs9rcFhV5RpeqSOl53Tyyhh62-TKysi3B5AmkVeZ2USqrxfB9Y2Bbh_a76w_PmUVyhdWn Continuedonpage 2 DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10)Graphicalpurlinrepresentationdoesnotdepictthesizeor theorientationof thepurlinalongthetopand/orbottom chord. LOADCASE(S)Standard 1)Dead +Snow(balanced):LumberIncrease=1.15,PlateIncrease=1.15 UniformLoads(lb/ft) Vert:1-2=-51,2-3=-51,6-11=-61,11-15=-51,15-16=-51,25-30=-20,17-24=-20 TrapezoidalLoads(lb/ft) Vert:3=-221-to-32=-217,32=-217-to-33=-214,33=-214-to-34=-197,34=-197-to-4=-186,4=-186-to-5=-183,5=-183-to-6=-151 Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T03 20 12005540-12T PiggybackBase Job Reference(optional) Run:8.42S8.40Apr72020Print:8.400SApr72020MiTek Industries, Inc.WedSep0216:36:28 Page: 2 ID:bUrs9rcFhV5RpeqSOl53Tyyhh62-TKysi3B5AmkVeZ2USqrxfB9Y2Bbh_a76w_PmUVyhdWn DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 12 3x4 =3x4 =4x4 1.5x4 =3x4 3x4 1 58 7 6 2 4 3 T1 T1 W1 W1B1 W2 Scale = 1:32.5 Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.08 Vert(LL)0.00 7>999360 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.03 Vert(CT)0.00 7>999240 TCDL 10.0 RepStress Incr YES WB 0.02 Horz(CT)n/a -n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight:13 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 WEBS 2x4SPFStud BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor3-4-0ocpurlins, exceptend verticals. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)6=144/0-4-0,(min.0-1-8),8=144/0-4-0,(min.0-1-8) Max Horiz8=70(LC15) Max Uplift6=-39(LC17),8=-39(LC16) Max Grav6=185(LC24),8=185(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E) zone; cantilever leftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRSforreactions shown;Lumber DOL=1.60plate grip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)This trusshasbeendesigned forgreaterofminroof live loadof12.0psfor2.00times flatroofloadof15.4psfonoverhangsnon-concurrentwithother live loads. 6)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 7)Bearingat joint(s)8,6 considersparallel tograin valueusingANSI/TPI1angle tograin formula.Buildingdesigner shouldverify capacityofbearing surface. 8)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding39 lbupliftat joint8and39 lbupliftat joint6. 9)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 T04 24 12005540-12T Common Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:29 Page: 1 ID:jHrIvqi9xpN_s_GM0hTaNvyhiWI-xWWFvOBkx4sMGjdg0YMACOht7b98jEBG9e8J0xyhdWm DE Job# 76789-W1 Dansco Engineering, LLC Date: 09/03/2020 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 10 12 =3x4 1 3 2 T1 T1 B1 Scale = 1:20.3 Plate Offsets(X,Y):[2:0-2-0,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in(loc)l/deflL/d PLATES GRIP TCLL(roof)20.0 PlateGripDOL 1.15 TC 0.09 Vert(LL)n/a -n/a999 MT20 197/144 Snow(Pf/Pg)15.4/20.0 LumberDOL 1.15 BC 0.08 Vert(TL)n/a -n/a999 TCDL 10.0 RepStress Incr YES WB 0.00 Horiz(TL)0.00 3n/an/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight:9 lbFT=20% LUMBER TOP CHORD2x4SPF No.2 BOT CHORD2x4SPF No.2 BRACING TOP CHORD Structuralwood sheathingdirectlyappliedor3-10-10ocpurlins. BOT CHORD Rigid ceilingdirectlyappliedor10-0-0ocbracing. MiTekrecommends thatStabilizersandrequired crossbracingbe installedduring trusserection, inaccordance withStabilizer Installationguide. REACTIONS (lb/size)1=136/3-10-0,(min.0-1-8),3=136/3-10-0,(min.0-1-8) Max Horiz1=39(LC13) Max Uplift1=-29(LC16),3=-29(LC17) Max Grav1=158(LC22),3=158(LC23) FORCES (lb)-Max. Comp./Max.Ten.-All forces250(lb)orlessexcept when shown. NOTES 1)Unbalancedrooflive loadshavebeen considered for thisdesign. 2)Wind:ASCE7-16;Vult=115mph(3-secondgust)Vasd=91mph;TCDL=5.0psf;BCDL=5.0psf;h=30ft; Cat. II; Exp C; Enclosed;MWFRS(envelope)exterior zoneandC-C Exterior(2E) zone; cantilever leftandrightexposed ; end vertical leftandrightexposed;C-C formembersand forces&MWFRSforreactions shown;Lumber DOL=1.60plate grip DOL=1.60 3)TCLL:ASCE7-16;Pr=20.0psf(roofLL:LumDOL=1.15Plate DOL=1.15);Pg=20.0psf;Pf=15.4psf(Lum DOL=1.15Plate DOL=1.15); Is=1.0; Rough CatC;PartiallyExp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loadshavebeen considered for thisdesign. 5)Gablerequires continuousbottom chordbearing. 6)This trusshasbeendesigned fora10.0psfbottom chord live loadnonconcurrent withanyother liveloads. 7)Providemechanical connection(byothers)of truss tobearingplatecapableofwithstanding29 lbupliftat joint1and29 lbupliftat joint3. 8)This truss is designed inaccordance with the2018 International ResidentialCodesections R502.11.1and R802.10.2andreferenced standardANSI/TPI1. LOADCASE(S)Standard Job Truss TrussType Qty Ply DWH-GramercyTHLots62-63-64-65 V01 4 12005540-12T Valley Job Reference(optional) Run:8.42 S 8.40Apr72020Print:8.400 SApr72020MiTek Industries, Inc.WedSep0216:36:29 Page: 1 ID:5yvSegqxkaQ9Mt8_nx6czpyhiTZ-xWWFvOBkx4sMGjdg0YMACOhtyb8MjEUG9e8J0xyhdWm