Loading...
HomeMy WebLinkAboutE050A2-16 D-16 D-16 D-16 D-16 A-16 A-16 A-16 A-16 A-16 A-16 D-16 A-16 A-16 A-16 A-16 A-16 D-16 D-16 D-16 D-16 A-16 A-16 A-16 A-16 A2-16 A2-16 A3-16 A-16 A-16 HA:55,57 HA:55,57HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:55,57 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 HA:59,61 TUTILITY TRANSFORMER A:17 WP A:17 WP A:17 WP A:17 WP A:17 WP A:17 WP PYLON SIGN HA:46,48 WP DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR EDOOG.RDIVAD PROFES SIONA L E N G INEERD E NADIIN A GER RTSIE STATE OF No. 10200395 E050 1 SCALE: 1" = 30'-0" ELECTRICAL SITE PLAN CANT AROUND TOP 1" (8) #4 REBAR VERTICALY WITH #4 REBAR SPIRALED AT 6" O.C. AND (3) LAYERS OF #4 REBAR AT TOP AND BOTTOM OF BASE SPACED AT 2" O.C. MAINTAIN MINIMUM OF 3" FROM REBAR TO EDGE OF CONCRETE. ANCHOR BOLTS HAND HOLE 1. POLE SHALL BE CAPABLE OF WITH STANDING 130 MPH WIND GUSTS 2. CONCRETE SHALL BE MINIMUM 3000 PSI 3. MATCH ANCHOR BOLT PATTERN TO POLE MANUFACTURERS BASE PLATE #6 COPPER GROUND WIRE BONDED TO POLE. 5/8"X10' GROUND ROD WITH EXOTHERMIC CONNECTION TO #6 GROUNDING CONDUCTOR. NOTES 60" GRADE 3/4" PVC CONDUIT TO POLE GROUND. 24" 2 NOT TO SCALE LIGHT POLE DETAIL GENERAL NOTES: 1. REFERENCE SHEET E-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. REFERENCE ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION OF WALL MOUNTED LIGHT FIXTURES. 3. SITE LIGHTING CONDUITS TO BE A MINIMUM OF 1" IN SIZE. 4. PROVIDE WEATHERPROOF GFI RECEPTACLE WITH WHILE IN USE COVER AT LIGHT POLES WHERE INDICATED ON PLAN. 5. DIFFERENT VOLTAGE SYSTEMS BRANCH CIRCUITRY SHALL BE RUN IN SEPARATE CONDUIT(S). 6. ALL LIGHT FIXTURES SHOWN ON THIS DRAWINGS SHALL BE FED FROM PANEL HA UNLESS NOTED OTHERWISE. 7. ALL BRANCH CIRCUITRY ON THIS DRAWINGS SHALL BE SIZE #8 MINIMUM. 8. ALL BRANCH CIRCUITRY SHALL HAVE DEDICATED GROUND WIRE SIZED PER NEC. 9. ALL EXTERIOR LIGHT FIXTURES SHALL BE TIME CLOCK CONTROLLED WITH PHOTOCELL OVERRIDE. ROUTE ASSOCIATED BRANCH CIRCUITRY THROUGH MULTI-POLE LIGHTING CONTACTOR. REFER TO SHEET E101 FOR ADDITIONAL INFORMATION. KEY NOTES: PROVIDE 120 VOLT CONNECTION TO POLE MOUNTED GFI RECEPTACLE PROVIDED BY LIGHT FIXTURE POLE MANUFACTURER. TYPICAL. PROVIDE CONNECTION TO PYLON SIGN PER SIGNAGE SHOP DRAWINGS. FIELD CONFIRM VOLTAGE REQUIREMENTS AND ADJUST THE SERVING BRANCH CIRCUITRY FROM EITHER PANEL HA OR A AS APPROPRIATE. CIRCUITRY SHALL BE CONTROLLED BY LIGHT VENDOR PROVIDED LIGHTING RELAY PANEL. 1 2 1 1 1 1 1 1 2 TOP OF ALL POLE BASES TO BE SAME ELEVATION AS MUCH AS POSSIBLE WITH MINIMUM DIMENSION ABOVE GRADE OR PAVING TO BE 2'-0". ALL "FRONT ROW" POLE BASES TO BE SAME ELEVATION ALWAYS 09/21/20