HomeMy WebLinkAboutE1027 4 11 12 14 28 KEY PLAN AB N C E H J M O S B A F T G L N K R P 37 37 39 39 41 41 TV J TV a b c d 9 6 D IR-2 ECH-1 EWH-1 T T T T J WP BUILDING SIGN J WP BUILDING SIGN WP GALLERY LIGHT BOX B:4 B:2 B:6, B:8 DC DC DCDC DCDC DC DC DCDC DC DC DC 37 39 41 38 38 38 38 38 3030 30 32 32 32 34 34 32 32 36 36 36 15 15 15 1515 15 15 13 16 16 16 31 31 23 21 19 24 26 35 35 3535 35 2222 22 22 22 20 20 1818 18 18 31 2927 33 33 3333 HA:50 20 20 XX 30 28 32 13 13 13 13 17 17 19 19 10 +42" HA:50 12 +42" 14 +42" J 16 18 18 20 20 22 19 25 33 +48" +48" 36 30 23 70 70 e DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR EDOOG.RDIVAD PROFES SIONA L E N G INEERD E NADIIN A GER RTSIE STATE OF No. 10200395 1 SCALE: 1/8" = 1'-0" FIRST FLOOR POWER PLAN - AREA 'A' E102 1. REFERENCE SHEET E-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. E.C. SHALL PROVIDE ALL RACEWAYS AND CONDUCTORS FOR HVAC INTERLOCKS AND THERMOSTATS. PRIOR TO ROUGH-IN COORDINATE EXACT REQUIREMENTS WITH M.C. 3. PRIOR TO ROUGH-IN VERIFY ALL LOCATIONS AND MOUNTING HEIGHTS OF DEVICES WITH OWNER AND ADJUST AS DIRECTED. 4. E.C. SHALL PROVIDE J-BOX ROUGH-IN @ +48" AT EACH TSTAT LOCATION. ROUTE 3/4" CONDUIT FROM J-BOX ROUGH-IN TO MECHANICAL UNIT LOCATION. REFER TO MECHANICAL PLANS FOR UNIT AND T-STAT LOCATIONS. 5. LINEWORK SHOWN DASHED INDICATES CONDUIT RUN UNDER SLAB. 6. ALL BRANCH CIRCUITRY SHOWN ON THIS SHEET SHALL BE FED FROM BRANCH PANEL B UNLESS NOTED OTHERWISE. REFERENCE SHEET E200 FOR PANEL B LOCATION. GENERAL NOTES: ROUGH-IN DEVICE CONCEALED BEHIND ELECTRICAL WATER COOLER. FIELD VERIFY EXACT ROUGH-IN LOCATION. GARAGE DOOR WITH SIDE MOUNTED MOTOR. GARAGE DOOR OPERATOR. COORDINATE FINAL LOCATION WITH OWNER/ARCHITECT PRIOR TO INSTALLATION. PROPOSED ROUTING FOR UNDERGROUND CONDUITS TO FEED FLOOR MOUNTED TELEPHONE/DATA/RECEPTACLE OUTLETS. ROUTE CONDUIT TO NEAREST FULL HEIGHT WALL. COORDINATE WITH ARCHITECT. 1-1/2"C MIN. SIZE FOR DATA/TELEPHONE, 3/4" CONDUIT FOR POWER. PROVIDE (4) OVERHEAD DOOR CONTROLLER STATIONS, 1 FOR EACH OVERHEAD DOOR IN SERVICE RECEPTION, MOUNTED ON WALL BEHIND SERVICE WRITERS DESK. CONTROLLERS SHALL OPERATE IN TANDEM WITH LOCAL CONTROLLERS AT OVERHEAD DOORS. INSTALL DEVICES CONCEALED BEHIND TV. INSURE THAT DEVICE LOCATIONS DO NOT INTERFERE WITH TV MOUNTING HARDWARE. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS. ROUTE VESTIBULE BRANCH CIRCUITRY FROM UNDER SLAB UP THROUGH COLUMN INTO VESTIBULE CEILING SPACE. COORDINATE ALL STRUCTURAL COLUMN PENETRATIONS WITH STRUCTURAL CONTRACTOR. PROVIDE DEDICATED 120 VOLT BRANCH CIRCUIT TO SIGN THROUGH LIGHTING CONTACTOR. INSTALL JUNCTION BOX ON STRUCTURE ABOVE ABOVE ACCESSIBLE CEILING. EXTEND BRANCH CIRCUITRY THRU WALL FRAMING TO SIGN. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS. COORDINATE WITH SIGN VENDOR. TAMPER RESISTANT RECEPTACLE. PROVIDE SURFACE-MOUNTED WEATHERPROOF J-BOX WITH (2) DEDICATED 20 AMP CIRCUITS AS SHOWN. J-BOX TO BE MOUNTED 2'-0" OFF THE DEALER ENTRANCE. REFER TO ARCHITECTURAL SHEET A-411 FOR ADDITIONAL INFORMATION. FIELD VERIFY FLOOR BOX LOCATIONS WITH OWNER. PROVIDE FLUSH MOUNTED PULL BOXES WITHIN ACCESSIBLE FURNITURE BASE FOR FEED-THRU TO DEVICES MOUNTED IN FURNITURE. EXTEND WIRING AND CONDUITS FROM PULL BOXES TO DEVICES MOUNTED IN FURNITURE. FIELD COORDINATE INSTALLATION WITH FURNITURE SHOP DRAWINGS. PROVIDE CONNECTION TO ELECTRIC HAND DRYER PER MANUFACTURER'S WRITTEN INSTRUCTION. FIELD VERIFY EXACT ROUGH-IN LOCATION. PROVIDE CONNECTION TO DOOR OPERATOR PER MANUFACTURER'S WRITTEN INSTRUCTIONS. KEY NOTES: 1 2 3 4 5 6 7 8 9 10 11 10 8 8 12 12 13 13 13 1 22 3 3 4 4 4 4 4 4 5 4 4 4 6 7 9 11 11 1111 11 11 11 14 14 6 09/21/20