HomeMy WebLinkAboutE1027 4 11 12 14 28
KEY PLAN
AB
N
C
E
H
J
M
O
S
B
A
F
T
G
L
N
K
R
P
37
37
39
39
41
41
TV
J
TV
a
b
c
d
9 6
D
IR-2
ECH-1
EWH-1
T
T
T
T
J WP
BUILDING
SIGN
J WP
BUILDING
SIGN
WP
GALLERY
LIGHT BOX
B:4
B:2
B:6, B:8
DC DC
DCDC DCDC DC DC DCDC DC DC DC
37 39 41
38
38 38
38
38
3030
30
32
32
32
34
34
32
32
36 36
36
15 15
15 1515 15 15
13
16
16
16 31
31
23
21
19
24 26
35
35
3535
35
2222
22
22
22
20
20
1818
18 18
31 2927
33
33
3333
HA:50
20
20
XX
30
28
32
13
13
13
13
17
17
19
19
10
+42"
HA:50
12
+42"
14
+42"
J
16
18 18
20
20
22
19
25
33
+48" +48"
36
30
23
70
70
e DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR
EDOOG.RDIVAD
PROFES
SIONA L E N G INEERD
E
NADIIN A
GER RTSIE
STATE OF
No.
10200395
1 SCALE: 1/8" = 1'-0"
FIRST FLOOR POWER PLAN - AREA 'A'
E102
1. REFERENCE SHEET E-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. E.C. SHALL PROVIDE ALL RACEWAYS AND
CONDUCTORS FOR HVAC INTERLOCKS AND
THERMOSTATS. PRIOR TO ROUGH-IN
COORDINATE EXACT REQUIREMENTS WITH
M.C.
3. PRIOR TO ROUGH-IN VERIFY ALL LOCATIONS
AND MOUNTING HEIGHTS OF DEVICES WITH
OWNER AND ADJUST AS DIRECTED.
4. E.C. SHALL PROVIDE J-BOX ROUGH-IN @ +48"
AT EACH TSTAT LOCATION. ROUTE 3/4"
CONDUIT FROM J-BOX ROUGH-IN TO
MECHANICAL UNIT LOCATION. REFER TO
MECHANICAL PLANS FOR UNIT AND T-STAT
LOCATIONS.
5. LINEWORK SHOWN DASHED INDICATES
CONDUIT RUN UNDER SLAB.
6. ALL BRANCH CIRCUITRY SHOWN ON THIS
SHEET SHALL BE FED FROM BRANCH PANEL B
UNLESS NOTED OTHERWISE. REFERENCE
SHEET E200 FOR PANEL B LOCATION.
GENERAL NOTES:
ROUGH-IN DEVICE CONCEALED BEHIND
ELECTRICAL WATER COOLER. FIELD VERIFY
EXACT ROUGH-IN LOCATION.
GARAGE DOOR WITH SIDE MOUNTED MOTOR.
GARAGE DOOR OPERATOR. COORDINATE FINAL
LOCATION WITH OWNER/ARCHITECT PRIOR TO
INSTALLATION.
PROPOSED ROUTING FOR UNDERGROUND
CONDUITS TO FEED FLOOR MOUNTED
TELEPHONE/DATA/RECEPTACLE OUTLETS. ROUTE
CONDUIT TO NEAREST FULL HEIGHT WALL.
COORDINATE WITH ARCHITECT. 1-1/2"C MIN. SIZE
FOR DATA/TELEPHONE, 3/4" CONDUIT FOR POWER.
PROVIDE (4) OVERHEAD DOOR CONTROLLER
STATIONS, 1 FOR EACH OVERHEAD DOOR IN
SERVICE RECEPTION, MOUNTED ON WALL BEHIND
SERVICE WRITERS DESK. CONTROLLERS SHALL
OPERATE IN TANDEM WITH LOCAL CONTROLLERS
AT OVERHEAD DOORS.
INSTALL DEVICES CONCEALED BEHIND TV. INSURE
THAT DEVICE LOCATIONS DO NOT INTERFERE WITH
TV MOUNTING HARDWARE. REFER TO
ARCHITECTURAL INTERIOR ELEVATIONS.
ROUTE VESTIBULE BRANCH CIRCUITRY FROM
UNDER SLAB UP THROUGH COLUMN INTO
VESTIBULE CEILING SPACE. COORDINATE ALL
STRUCTURAL COLUMN PENETRATIONS WITH
STRUCTURAL CONTRACTOR.
PROVIDE DEDICATED 120 VOLT BRANCH CIRCUIT
TO SIGN THROUGH LIGHTING CONTACTOR.
INSTALL JUNCTION BOX ON STRUCTURE ABOVE
ABOVE ACCESSIBLE CEILING. EXTEND BRANCH
CIRCUITRY THRU WALL FRAMING TO SIGN. REFER
TO ARCHITECTURAL SHEETS FOR ADDITIONAL
INFORMATION. ELECTRICAL CONTRACTOR SHALL
MAKE FINAL CONNECTIONS. COORDINATE WITH
SIGN VENDOR.
TAMPER RESISTANT RECEPTACLE.
PROVIDE SURFACE-MOUNTED WEATHERPROOF
J-BOX WITH (2) DEDICATED 20 AMP CIRCUITS AS
SHOWN. J-BOX TO BE MOUNTED 2'-0" OFF THE
DEALER ENTRANCE. REFER TO ARCHITECTURAL
SHEET A-411 FOR ADDITIONAL INFORMATION.
FIELD VERIFY FLOOR BOX LOCATIONS WITH
OWNER.
PROVIDE FLUSH MOUNTED PULL BOXES WITHIN
ACCESSIBLE FURNITURE BASE FOR FEED-THRU TO
DEVICES MOUNTED IN FURNITURE. EXTEND
WIRING AND CONDUITS FROM PULL BOXES TO
DEVICES MOUNTED IN FURNITURE. FIELD
COORDINATE INSTALLATION WITH FURNITURE
SHOP DRAWINGS.
PROVIDE CONNECTION TO ELECTRIC HAND DRYER
PER MANUFACTURER'S WRITTEN INSTRUCTION.
FIELD VERIFY EXACT ROUGH-IN LOCATION.
PROVIDE CONNECTION TO DOOR OPERATOR PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
KEY NOTES:
1
2
3
4
5
6
7
8
9
10
11
10
8
8
12
12 13 13 13
1
22
3
3
4
4
4
4
4
4
5
4
4
4
6
7
9
11
11
1111
11
11
11
14
14
6
09/21/20