55° SUSPENSIONDROP ROD
NOTE:
HOOKS ARE TO BE
CLOSED UP AFTER
ASSEMBLY
2/0 GA CHAIN
(TWISTED LINK,
PLATED)
EYE HOOK
PURLING FASTENERS
REFLECTOR
BRACKET
OPTIONAL
TURNBUCKLE
(±3" ADJUSTMENT)
3 8Ø ROD
CHAIN
('U' TYPE SHOWN)
2/0 GA CHAIN
(TWISTED LINK,
PLATED)
EYE HOOKS
* THESE ANGLES TO BE EQUAL
AND NOT MORE THAN 45°
**
**
ON U TUBE VARIANTS THE HEATER SHOULD SLOPE DOWNWARDS TOWARDS THE RETURN BEND AND
ON LINEAR VARIANTS SHOULD SLOPE DOWNWARDS TOWARDS BURNER BY APPROX. 1/2" FOR BOTH
HORIZONTAL AND WALL MOUNTED INSTALLATIONS.
WHERE CHAIN SUPPORTS
HAVE AN ANGLE OF
INCLINATION GREATER THAN
15° AN EQUAL AND OPPOSITE
SUPPORT IS RECOMMENDED
VERTICAL SUSPENSION CHAIN IDEAL. WHERE
SUPPORTS ARE INCLINED, MAXIMUM
RECOMMENDED ANGLE OF INCLINATION IS 15°
15°
MAX
LAY-IN DIFFUSER DETAIL
NO SCALEB
SECURE FLEXIBLE DUCT TO SUPPLY DIFFUSER
ELBOW FITTING WITH DRAWBAND.
SHEET METAL ELBOW
1-1/2" DUCT WRAP
SUPPLY DIFFUSER CEILING
MOUNT DIFFUSER IN
BOTTOM OF BRANCH
WITH SADDLE AS HIGH
AS POSSIBLE
SPIRAL BRANCH DUCT
TIGHT TO OR
THROUGH STRUCTURE
ADJUSTABLE GRIPPLE
STRANDED WIRE
HANGER TYPICAL.
SPIRAL CAP
FULLY FRAMED OPENING IN
DRYWALL CEILING.
CONCEALED FASTENER LINEAR
SLOT DIFFUSER PER SCHEDULE.
CUSTOM FABRICATED OR
MANUFACTURERS INTERNALLY
LINED PLENUM BOX WITH
RECTANGULAR, OVAL OR ROUND
TAKE OFF SIZE PER PLANS.
INFRARED HEATER INSTALLATION DETAILS
NO SCALEG
LAY-IN DIFFUSER DETAIL
NO SCALE A
INTAKE/RELIEF HOOD DETAIL
NO SCALED
30° MAX
O
AIR FLOW
45 DEG.
OCL CONNECTION
TAKE OFF. HAMMER
LOCKED OR FLANGED AND FULLY SEALED
RECTANGULAR
DUCT
BRANCH
CONCENTRIC TRANSITION
MAX, 45 DEG. DIVERGING
AND 60 DEG. CONVERGING
OFFSET. PROVIDE
MINIMUM 2" STRAIGHT
SECTION AT EACH END.
MAX 30 DEG.
ECCENTRIC TRANSITION MAX, 30 DEG.
30° MAX
AIR FLOWV.D.
HIGH EFFICIENCY
FLANGED TAKE OFF
COMPLETELY SEALED
ROUND SHEET METAL
DUCT TO WITH IN
5'-0" OF
DIFFUSER
NOTE:
AIRFOIL BLADES TO BE USED WHERE
NORMAL RADIUS ELBOW IS
IMPRACTICAL
& WHERE ELBOW IS WITHIN 5 FT OF A
BRANCH TAKE-OFF.
NOTE:
IN GENERAL, ELBOWS TO HAVE
FULL TURNING RADIUS (R=A).
WHERE "R" IS EQUAL TO OR
GREATER THAN "A" MINIMUM
RADIUS (R) = 4 INCHES.
R=A 118"
A
SHEET METAL GAUGES AND RIGIDITY SHALL BE IN
ACCORDANCE WITH SMACNA PRESSURE CLASS 1.0" UNLESS
OTHERWISE SPECIFIED.
DUCT CONSTRUCTIN DETAILS
NO SCALEH
3/4 PVC TRAPPED COND.
DRAIN. PROVIDE TRAP DEPTH
PER MANUFACTURE WITH
CLEAN OUT PLUG.
FRESH AIR INTAKE HOOD
MAINTAIN MINIMUM OF 10'-0"
FROM ALL EXHAUST AND
PLUMBING VENTS
3" MIN.
48" LONG SHEET METAL
DROPS FULL CURB OPENING
SIZED AND LINED WITH 1"
DUCT LINER AND WITH FLEX
CONNECTOR
CUT ROOF DECK ONLY AS
NEEDED FOR DUCT DROPS.
PROVIDE R-13 BATT OR
ROOFING INSULATION PLACED
ON REMAINING DECK.
ELECTRICAL DISCONNECT
PER NEC
MAINTAIN MINIMUM OF 10'-0"
FOR EDGE OF ROOF
AGA GAS SHUT OFF, 2
PSIG-7" W.C. REGULATOR
DIRT LEG AND UNION BY PC.
PROVIDE NEOPRENE CURB
TAPE AT DUCT CONNECTION
SEAL AIR TIGHT.
PLACE EXTRA ROOF
MEMBRANE BETWEEN
MIRO 1.5 POLYCARBONATE
PIPE SUPPORTS PIPE
SUPPORT AND ROOF
MEMBRANE. TYP.
STEEL ANGLE FRAME BY STEEL
ERECTION CONTRACTOR COORDINATE
SIZES WITH STEEL SHOP DRAWINGS.
ROUND CHIMNEY TOP
METALBESTOS FLUE
RECOMMENDATIONS
MANUFACTURER'S
INSTALL PER
NOTE
FLASHING
ROOF
STORM COLLAR
METAL ROOF
AIR SPACE AROUND FLUE
LISTED
CONNECT TO APPLIANCE WITH B-VENT CONNECTOR
PIPING SLOPE AT MINIMUM 1/4" PER FOOT
14" HIGH MINIMUM
PRE-FABRICATED ROOF
CURB ATTACHED TO
CONCRETE ROOF
STRUCTURE WITH
CONCRETE ANCHORS.
SECURE VENT TO
ROOF CURB AS
REQUIRED WITH
SHEET METAL
SCREWS.
DUCT TO BE SAME
SIZE AS THROAT
SIZE OF VENT.
RELIEF VENT
PROVIDE 1/2" X 1/2" WELDED
WIRE MESH SCREEN OVER END
OF DUCT.
ROOF CONSTRUCTION.
REFER TO ARCHITECTURAL
DRAWINGS FOR TYPE.
SEAL ALL JOINTS.
MOTORIZED CONTROL DAMPER BY
RELIEF HOOD VENDOR.
SPIRAL DUCT DIFFUSER DETAIL
NO SCALE C
SPIRAL DUCT DIFFUSER DETAIL
NO SCALE E RTU INSTALLATION DETAIL
NO SCALEF
CAULK WATER TIGHT
ATTACH TO
ROOF DECK
W/ #10 SHEET
METAL SCREWS
MINIMUM 36" ABOVE ROOF LINE
METALBESTOS CONNECTOR
ROUTED FULLY TO APPLIANCE
NO SINGLE WALL ALLOWED.
INTAKE VENT
REFERENCE ARCHITECTURAL
REFLECTED CEILING PLAN AND
ELECTRICAL LIGHTING PLAN AND
COORDINATE INSTALLATION WITH
ALL CEILING ELEMENTS.