Loading...
HomeMy WebLinkAboutM003DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR EDOOG.RDIVAD PROFES SIONA L E N G INEER D E NADIIN A GER RTSIE STATE OF No. 10200395 12" MIN. METAL ROOF DECK MECH. DUCT INSULATION THICKNESS. AS REQUIRED TO MATCH TREATED WOOD BLOCKING EXHAUST FAN PROVIDE (2) LAG SCREWS PER SIDE WITH NEOPRENE WASHSERS SEAL FAN TO CURB WITH NEOPRENE GASKET AIR TIGHT GRAVITY BDD 3X3 ANGLE REF. STRUCTURAL PLANS. (2) 3 X 3 X 5/16 ANGLES FACE TO FACE BOLTED TO ROOF JOIST BY M.C. FAN MOUNTING BRACKETS, BOLTS, WASHERS AND SAFETY CABLE BY FAN MANUFACTURER. BOLT TO C CHANNEL OR TO BOTTOM OF GIRDER. SCALE : NONE BIG ASS FAN MOUNTING DETAILA SECTION AA A A DUCT LESS SPLIT TRAP SUCTION LINE EVERY 10' UP RISER NOT TO SCALE MINI SPLIT INSTALLATION DETAILD PATE PORTAL ROOF CURB TYPICAL ALL LINE SETS. INSULATE AND SEAL WATER TIGHT. INVERTED SUCTION LINE TRAP. SLOPE LINE BACK TO COMPRESSOR. DISCONNECT BY E.C. AIR COOLED CONDENSING UNIT WALL WALL BIRD SCREEN CAULK INTERIOR AND EXTERIOR PERIMETER WEATHER TIGHT WITH SILICON CAULKING. LOUVER WITH KYNAR FINISH TO MATCH BLDG. COLOR EXTERIOR 1"X1"X1/8" STEEL ANGLE. SCREW TO LOUVER SLEEVE 6" O.C. # 10 SCREWS AND ANCHORED TO MASONRY WALL 12" O.C. WITH 1/4" MASONRY ANCHORS. TYPICAL TOP, BOTTOM AND SIDES. SCALE : NONE EXHAUST FAN DETAIL B SCALE : NONE WALL LOUVER DETAILC GALVANIZED EQUIPMENT RAIL BY MC 1/2" HOSE TO OPEN SITE INVERTED TEE IN PVC DRAIN LINE BY MC ROUTE 3/4 SCH 40 PVC LINE TO HUB/FLOOR DRAIN PROVIDED BY P.C. AT MINIMUM 1/4" PER FT SUPPORT MIN. 5' OC. MINI-WHITE TANK MINI SPLIT CONDENSATE PUMP WITH HIGH LEVEL CUT OUT. WIRE TO IDU PER MANUFACTURES INSTRUCTIONS MINIMUM 48" PRIOR TO ROUGH-IN COORDINATE CLEARANCES OF BLADES WITH ALL TRADES AND EQUIPMENT SUPPLIERS. M003 OPTIONAL SUSPENDED CEILING INSTALLATION OF SUNTUBE HEATER STANDARD REFLECTOR 12" MINIMUM SHIELD NOTCH AS REQUIRED AROUND THE REFLECTOR SUPPORT BRACKET H EXTENSION REFLECTOR 4'-0" LONG X 8", 12", OR 16" WIDE SUSPENDED CEILING FRAME 2 FT. ALUMINUM LOUVER SCALE : NONE INFRARED HEATER SUSPENDED CEILING INSTALLATIONE PARTICULAR CONSIDERATION MUST BE GIVEN TO CLEARANCES TO COMBUSTIBLES IN THIS TYPE OF INSTALLATION. SINCE THE STANDARD REFLECTOR IS USED, THE CLEARANCE TO COMBUSTIBLES WILL BE THE SAME AS INDICATED IN THE "SUMMARY OF SPECIFICATIONS" IN THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTION MANUAL. VERIFY THAT THE CEILING PANELS ADJACENT TO EACH SIDE OF THE HEATER ARE ARE NOT COMBUSTIBLE OR THAT THEY ARE MADE OF CLASS A MATERIALS. VERIFY THE INSTALLATION IS ACCEPTABLE TO LOCAL AUTHORITIES. IN ADDITION, TO PROVIDE ADEQUATE COMFORT LEVELS, REFER TO "HEATER LOCATION" IN THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTION MANUAL TO IDENTIFY MINIMUM MOUNTING HEIGHT. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS IN THIS EQUIPMENT, OR COVER EVERY POSSIBLE SITUATION TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD PROBLEMS ARISE THAT ARE NOT COVERED SUFFICIENTLY IN THESE INSTRUCTIONS, THE PURCHASER IS ADVISED TO CONTACT THE ENGINEERING DEPARTMENT AT SOLARONICS, INC. FOR FURTHER INFORMATION. THE SUNTUBE LOW-INTENSITY GAS INFRARED HEATER CAN BE INSTALLED OVER SUSPENDED CEILINGS WITH AN ALUMINUM LOUVER DIRECTLY BELOW THE HEATER. THE ALUMINUM LOUVER IS A 2 FOOT WIDE X 4 FOOT LONG BY 1/2" THICK, NON-FLAMMABLE , 1/2" X 1/2" OPEN-GRID CELL PATTERN CONSTRUCTED OF 0.015" ALUMINUM WITH A MILL FINISH. NEVER USE REGULAR CEILING TILES DIRECTLY BELOW THE HEATER SINCE IT WOULD CREATE AN UNSAFE CONDITION. THE HEATER IS INSTALLED IN A NORMAL FASHION (AS DESCRIBED IN THE INSTRUCTION MANUAL) WITH THE TUBE SUSPENDED OVER THE LOUVERS FROM A MINIMUM HEIGHT OF 4.000" TO A MAXIMUM HEIGHT OF 14.375" (DISTANCE H). CALCULATE DISTANCE "H" BETWEEN THE BOTTOM OF THE HEAT EXCHANGER TUBE TO THE TOP OF THE LOUVER TO DETERMINE THE SIZE OF THE EXTENSION REFLECTORS REQUIRED FROM THE FOLLOWING TABLE: THE EXTENSION REFLECTORS ARE AVAILABLE IN STANDARD 4 FOOT SECTIONS AND ARE LAID ALONGSIDE THE STANDARD REFLECTORS. IT MAY BE NECESSARY TO CUT NOTCHES FOR CLEARANCE AROUND THE REFLECTOR SUPPORT BRACKETS. A SHIELD,IS PLACED OVER THE SUSPENDED CEILING FRAME MEMBER WHICH PASS DIRECTLY UNDERNEATH THE HEATER. FOR YOUR SAFETY, GLOVES ARE TO BE WORN WHEN HANDLING THE ALUMINUM LOUVERS TO PROTECT THE HANDS FROM SHARP EDGES. ALLOW A 12 INCH MINIMUM CLEARANCE FROM THE TOP AND SIDES OF THE BURNER. 09/21/20