HomeMy WebLinkAboutM10118
250
T
100
S-1
100
S-1
250
S-6
250
S-6 250
S-6 S-6
250
S-6
250
S-6
200
S-6 200
S-6
200
S-6
200
S-6
200
S-6
RTU-7
7.5 TON
IR-2 IR-2
IR-3 RTU-48"Ø 10"Ø
12"Ø 14"Ø 16"Ø
8"Ø 10"Ø 12"Ø 14"Ø 16"Ø 16"Ø 16"Ø100
S-1
100
S-1
120
8" W.C.10"Ø8"Ø 12"Ø6"Ø
6"Ø 6"Ø
12"Ø UP
BAF-1BAF-1 CF-1T
T
CF-1
IR-3
6"Ø FLUECOMS
UH-1
UH-1
16/16 UP
TO IH-2
8"Ø UP
TO EF-4
18"Ø UP
TO EF-3
R-2
R-2
S-4S-4 S-4
IR-3
IR-3
6"Ø FLUEIR-1
100
EF-11
100
EF-10
8"Ø 6"Ø16"Ø
12"Ø12"Ø 12"Ø
100
S-6
T
T
T
200
S-6
EWH-1
BBS
SC
MS
CO
NOx
BBS
SC
MS
CO
NOx
OAOA
KEY PLAN
AB
N DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR
EDOOG.RDIVAD
PROFES
SIONA L E N G INEER D
E
NADIIN A
GER RTSIE
STATE OF
No.
10200395
1 SCALE: 1/8" = 1'-0"
FIRST FLOOR HVAC PLAN - AREA 'B'
KEY NOTES:
GENERAL NOTES:
1 IR HEATERS SHALL BE SIMULTANEOUSLY
CONTROLLED IN GROUPS BY SMARTCOM
MULTIZONE IR TEMPERATURE CONTROL PANEL
WITH REMOTE BLACK BULB AND OA SENSOR.
RACEWAYS FOR TCC AND BURNER/BLOWER
INTERLOCKS ARE BY E.C. ALL CONTROLS AND
HEATER COMPONENTS BY M.C.
COORDINATE AND LOCATION OF ALL INFRARED
HEATERS WITH OWNER AND INSTALL PER
MANUFACTURES RECOMMENDED CLEARANCES
WITH REGARD TO CAR LIFTS AND GARAGE
EQUIPMENT. SEE DETAILS ON SHEET M002 FOR
MORE INFORMATION. TYPICAL. PIPE CA FOR
DETAIL BAY HEATER TO WALL CAP, ALL OTHER
HEATERS TO DRAW CA FROM INDOORS.
ROUTE DUCTING BELOW 2ND FLOOR FRAMING
TIGHT TO I BEAMS. COORDINATE WITH PLUMBING,
SPRINKLER AND ELECTRICAL CONTRACTORS.
MOUNT CEILING FAN TO ROOF JOIST PER
MANUFACTURERS INSTRUCTIONS, ELEVATION TO
BE COORDINATED WITH THE LIGHTING SYSTEMS
AND IR HEATERS. SEE DETAIL ON SHEET M002.
INSTALL SERVICE WRITE UP BAY 100 MBH, 40'
LONG STRAIGHT TUBE IR HEATERS SIMILAR TO
RH1 MOUNTED ABOVE ACOUSTIC CEILING WITH
MANUFACTURERS CEILING KITS. INSTALL
ALUMINUM GRILLES AND T-BAR SHIELDS PER
INSTRUCTIONS
BOTTOM OF RADIANT TUBE HEATER NEED TO BE
AT 12'-0 OFF OF FINISHED FLOOR
ROUTE ALL DUCT WORK IN SERVICE DEPARTMENT
IN TRUST SPACE.
ROUTE ALL DUCT WORK UP IN JOIST SPACE.
1. REFERENCE SHEET M-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
2. REFERENCE SHEETS M-002 THOUGH M-004 FOR
DETAILS, SCHEDULES AND NOTES.
3. PRIOR TO ROUGH IN, COORDINATE TEMPERATURE
CONTROL RACEWAYS WITH E.C. M.C. TO PROVIDE
ALL CONTROLS AND LOW VOLTAGE CABLES, E.C. TO
PROVIDE ALL MOTOR STARTERS, RACEWAYS AND
LINE VOLTAGE CONDUCTORS.
2
3
4
5
1
1
2
2
5
5
2 2
2
2
3
44
M101
3
6
6 6
7
7
7
8
09/21/20