HomeMy WebLinkAboutP003DATAREV.DATADWG.OF CARMELNAPLETON KIANapleton Automative GroupMEP Engineer874 Cheltenham WayAvon, IN 46123317.506.8151317.745.5761dave@gnaengineering.comGOODERUM & ASSOCIATES ENGINEERINGP: F: E: MUR EDOOG.RDIVAD PROFES SIONA L E N G INEER D E NADIIN A GER RTSIE STATE OF No. 10200395 STEEL PIPE FLOOR SLEEVE RISER CLAMP BOLT SLAB FIRE CAULKING OAKUM PACKING (OMIT IF RUBBER SEAL IS USED.) C PIPE SLEEVE FLOOR PENETRATION SINGLE PIPE HANGER DETAILA INSULATED PLUMBING PIPES. RIGID MOLDED FIBERGLASS INSULATION METAL PROTECTION SHIELDS HANGING RODS 12" MIN. NUTS & LOCK WASHERS SUPPORT CHAIR BOLTED TO CHANNEL STEEL CHANNEL ADEQUATE TO CARRY LOAD GENERAL NOTES: 1) PROTECTION SADDLES SHALL BE COPPER CLAD IF COPPER TUBE IS USED. 2) PROVIDE INTERMEDIATE HANGING ROD SUPPORT WHERE NUMBER OF PIPES EXCEED FIVE(5). TRAPEZE HANGER DETAILB ADD PIPE SLEEVE THAT HAS AN INSIDE DIAMETER, 14"± LARGER THAN OUTSIDE DIA. PIPE HANGER ROD CLIP CONNECTION 3/8" ROD ATTACHED TO TOP OF STRUCTURAL ROOF FRAMING MEMBER WITH BEAM CLAMP. "L" 6'-0"MAX. ADD FRAMING CHANNEL OR ANGLE WHEN "L" IS GREATER THAN MAX. LENGTH. CLEVIS PIPE HANGER SAME AS OPPOSITE SIDE M.J. X FL. ADAPTER 3/4" ALL THR. ROD WASHER TIE BOLT "J" BOLT OR HEX NUT & THRUST BLOCK (PER NFPA 24) 6" U.G. PIPING D.I.P. RISER TO RISER BY DESIGN AND BUILD FIRE LINE DETAILD FIRE SUPPRESION CONTRACTOR E BACKFLOW PREVENTOR DETAIL OVERFLOW DRAIN J.R. SMITH MODEL 1080Y ROOF OVERFLOW DRAIN NO-HUB WITH DUCO CAST IRON BODY / FLASHING CLAMP AND POLYETHYLENE DOME H ROOF DRAIN DETAIL ROOF DRAIN J.R. SMITH MODEL 1010Y ROOF DRAIN NO-HUB WITH DUCO CAST IRON BODY / FLASHING CLAMP AND POLYETHYLENE DOME APPX. 24" O.C. I WASH BAY PSI WASHER STATION 3/4" HW (FROM OVERHEAD HOT WATER) 3/4" CW (FROM OVERHEAD COLD WATER) 3/4" HOSE BIBB SPIGOT 3/4" BALL VALVE (H & C) MOUNT AT +36" AFF FIN. FLOOR TEMPERATURE GAGE 18" 2" TO DOMESTIC SYSTEM REDUCED PRESSURE ZONE BACKFLOW PREVENTER: WATTS MODEL 009M2QTS CAST BRONZE CONSTRUCTION WITH QUARTER TURN FULL-PORT BALLVALVES (VERIFY W/ LOCAL UTILITY CO.) WATER METER W/ REMOTE READ 30""RISING STEM GATE VALVES FROM CITY WATER MAIN 2" ROUND CHIMNEY TOP METALBESTOS FLUE RECOMMENDATIONS MANUFACTURER'S INSTALL PER NOTE FLASHING ROOF STORM COLLAR METAL ROOF AIR SPACE AROUND FLUE METALBESTOS FLUE, SEAL WITH FLUE DETAILK LISTED HIGH TEMPERATURE SEALANT. CONNECT TO APPLIANCE WITH B-VENT CONNECTOR PIPING SLOPE AT MINIMUM 1/4" PER FOOT GAS PIPING MIRO PIPE HANGER MODEL #1.5 J ROOF GAS PIPING SUPPORT ROOF DECK P003 F POINT OF USE WATER HEATER DETAIL FACTORY SUPPLIED HEAT TRAP PIPE NIPPLE CASH ACME TMV C INCOMING COLD WATER (CONCEALED IN WALL) INSTANTANEOUS WATER HEATER WALL MOUNTED SEE SCHEDULE Finished Floor WARNING: THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES; CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS. 3. SERVICE VALVES ARE SHOWN FOR SERVICING UNIT. HOWEVER, LOCAL 2. THE TEMPERATURE AND PRESSURE RELIEF VALVE SETTING SHALL NOT EXCEED PRESSURE RATING OF ANY COMPONENT IN THE SYSTEM. 1. PREFERRED PIPING DIAGRAM. NOTES: CODES SHALL GOVERN THE USAGE OF ANY COMPONENT IN THE SYSTEM. OUTGOING HOT WATER (CONCEALED IN WALL) 3 4" SHUT OFF TYPICAL DIGITAL LIGHT PWRD THERMOMETER SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE HW CW EWH VALVE TANK DRAIN 2" METAL DRAIN PAN TERMINATE RELIEF OVER DRAIN PAN 3/4" INSULATED HW SUPPLY G WATER HEATER DETAIL TMV THERMOSTATIC MIXING VALVE COLD WATER ASME T&P EXPANSION TANK FACTORY SUPPLIED HEAT TRAP NIPPLES OR 27" HEAT TRAP 110 DEG. WATER TEMPERATURE GAGE EXP-1 SIMILAR TO AO SMITH PMC-2 INSULPAD-310854 2" HEATER PAD FLOOR DRAIN SCALE: NONE 09/21/20