STEEL PIPE FLOOR
SLEEVE RISER CLAMP
BOLT
SLAB
FIRE CAULKING
OAKUM PACKING
(OMIT IF RUBBER
SEAL IS USED.)
C PIPE SLEEVE FLOOR PENETRATION SINGLE PIPE HANGER DETAILA
INSULATED PLUMBING PIPES.
RIGID MOLDED FIBERGLASS
INSULATION
METAL PROTECTION SHIELDS
HANGING RODS
12" MIN.
NUTS & LOCK
WASHERS
SUPPORT CHAIR
BOLTED TO
CHANNEL
STEEL CHANNEL
ADEQUATE TO
CARRY LOAD
GENERAL NOTES:
1) PROTECTION SADDLES SHALL BE COPPER CLAD IF COPPER TUBE IS USED.
2) PROVIDE INTERMEDIATE HANGING ROD SUPPORT WHERE NUMBER OF PIPES
EXCEED FIVE(5).
TRAPEZE HANGER DETAILB
ADD PIPE SLEEVE THAT HAS
AN INSIDE DIAMETER, 14"±
LARGER THAN OUTSIDE DIA.
PIPE HANGER ROD CLIP
CONNECTION
3/8" ROD ATTACHED TO TOP
OF STRUCTURAL ROOF
FRAMING MEMBER WITH BEAM
CLAMP.
"L" 6'-0"MAX.
ADD FRAMING CHANNEL
OR ANGLE WHEN "L" IS
GREATER THAN MAX.
LENGTH.
CLEVIS
PIPE HANGER
SAME AS
OPPOSITE
SIDE
M.J. X FL. ADAPTER
3/4" ALL THR. ROD
WASHER
TIE BOLT
"J" BOLT OR
HEX NUT &
THRUST BLOCK
(PER NFPA 24)
6" U.G. PIPING
D.I.P. RISER
TO RISER BY DESIGN AND BUILD
FIRE LINE DETAILD
FIRE SUPPRESION CONTRACTOR
E BACKFLOW PREVENTOR DETAIL
OVERFLOW DRAIN
J.R. SMITH MODEL 1080Y ROOF
OVERFLOW DRAIN NO-HUB
WITH DUCO CAST IRON BODY /
FLASHING CLAMP AND
POLYETHYLENE DOME
H ROOF DRAIN DETAIL
ROOF DRAIN
J.R. SMITH MODEL 1010Y
ROOF DRAIN NO-HUB WITH
DUCO CAST IRON BODY /
FLASHING CLAMP AND
POLYETHYLENE DOME
APPX. 24" O.C.
I WASH BAY PSI WASHER STATION
3/4" HW
(FROM OVERHEAD HOT WATER)
3/4" CW
(FROM OVERHEAD COLD WATER)
3/4" HOSE BIBB SPIGOT
3/4" BALL VALVE
(H & C)
MOUNT AT +36" AFF
FIN. FLOOR
TEMPERATURE
GAGE
18"
2"
TO DOMESTIC
SYSTEM
REDUCED PRESSURE ZONE BACKFLOW
PREVENTER: WATTS MODEL 009M2QTS
CAST BRONZE CONSTRUCTION WITH
QUARTER TURN FULL-PORT BALLVALVES
(VERIFY W/ LOCAL UTILITY CO.)
WATER METER
W/ REMOTE READ
30""RISING STEM
GATE VALVES
FROM CITY
WATER MAIN 2"
ROUND CHIMNEY TOP
METALBESTOS FLUE
RECOMMENDATIONS
MANUFACTURER'S
INSTALL PER
NOTE
FLASHING
ROOF
STORM COLLAR
METAL ROOF
AIR SPACE AROUND FLUE
METALBESTOS FLUE, SEAL WITH
FLUE DETAILK
LISTED
HIGH TEMPERATURE SEALANT.
CONNECT TO APPLIANCE WITH B-VENT CONNECTOR
PIPING SLOPE AT MINIMUM 1/4" PER FOOT
GAS PIPING
MIRO PIPE
HANGER MODEL
#1.5
J ROOF GAS PIPING SUPPORT
ROOF DECK
P003
F POINT OF USE WATER HEATER DETAIL
FACTORY SUPPLIED
HEAT TRAP PIPE NIPPLE
CASH ACME TMV
C
INCOMING COLD WATER
(CONCEALED IN WALL)
INSTANTANEOUS WATER
HEATER WALL MOUNTED
SEE SCHEDULE
Finished Floor
WARNING: THIS DRAWING SHOWS SUGGESTED
PIPING CONFIGURATION AND OTHER DEVICES;
CHECK WITH LOCAL CODES AND ORDINANCES
FOR ADDITIONAL REQUIREMENTS.
3. SERVICE VALVES ARE SHOWN FOR SERVICING UNIT. HOWEVER, LOCAL
2. THE TEMPERATURE AND PRESSURE RELIEF VALVE SETTING SHALL NOT
EXCEED PRESSURE RATING OF ANY COMPONENT IN THE SYSTEM.
1. PREFERRED PIPING DIAGRAM.
NOTES:
CODES SHALL GOVERN THE USAGE OF ANY COMPONENT IN THE SYSTEM.
OUTGOING HOT WATER
(CONCEALED IN WALL)
3
4" SHUT OFF
TYPICAL
DIGITAL LIGHT PWRD
THERMOMETER
SCALE: NONE
SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE
SCALE: NONE
SCALE: NONE SCALE: NONE SCALE: NONE
HW CW
EWH
VALVE
TANK DRAIN
2" METAL DRAIN PAN
TERMINATE RELIEF
OVER DRAIN PAN
3/4"
INSULATED HW
SUPPLY
G WATER HEATER DETAIL
TMV
THERMOSTATIC
MIXING VALVE
COLD WATER
ASME T&P
EXPANSION TANK
FACTORY SUPPLIED HEAT
TRAP NIPPLES OR 27" HEAT TRAP
110 DEG. WATER
TEMPERATURE GAGE
EXP-1
SIMILAR TO AO SMITH PMC-2
INSULPAD-310854
2" HEATER PAD
FLOOR DRAIN
SCALE: NONE
09/21/20