HomeMy WebLinkAboutA001-LIFE-SAFETY-PLAN-Rev.2RELEA5E0 FOR CONSTRIlCTION
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
�
�un��\i lo•rvalM��'
I �
�
�
�
�
LINE OF �5' FIRE
EXTINGUISHER
RADIUS
EXISTING
EXIT
i�ll
LIFE SAFETY PLAN
S�ale: 3/32" = 1'-0"
.
�
�
;
CODE INFORMATION
APPLICABLE CODES:
ALL WORK UNDER THIS CONTRACT SHALL COMPLV WITH THE
PROVISIONS OF THE SPEQFlCATIONS 8 DRAW INGS AND SHALL
SATISFV ALL APPLICABLE CO�ES, OR�INANCES, A.D.A., AND
REGULATIONS OF ALL GOVERNING BODIES INVOLVED.
ALL PERMITS AND LICENSES NECESSARV FOR THE PROPER
EXEWTION OF THE WORK SHALL BE SEWRED AND PAID FOR BV
THECONTRACTORINVOLVED.
THE FOLLOWING CODES AN� REGULATIONS ARE CURRENTLV
ADOPTED BV THE STATE OF INDIANA AT THE TIME A BUILDING
PERMIT IS APPLIE� FOR:
BUILDING CODE: INDIANA BUILDING CODE 2014
QNTERNATIONAL BUILOING CODE 2012
WITH INDIANAAMENDMENTS)
MECHANICAL CODE'. INDIANA MECHANICAL CODE 2014
(INTERNATIONAL MECHANICAL CODE 2012
WITH INDIANA AMENDMENTS)
ELECTRICALCODE INDIANAELECTRICALCODE2009
(NATIONAL ELECTRICAL CODE 2�08
- NFPA ]0 W ITH IN�IANA AMENDMENTS)
PLUMBING CODE: INDIANA PLUMBMG CODE 2012
(UMFORM PLUMBING CODE 2008)
FIRE CODE: INDIANA FIRE CODE 2�14
(INTERNATIONAL FIRE CODE 2�12
WITH INDIANA AMENDMENTS)
ENERGY CODE�. INDIANA ENERGV CONSERVATION CODE
201� (ASHRAE 90.1- 2001 WITH INOIANA
AMENDMENT9)
FUEL GAS CODE'. INDIANA FUEL GAS CODE 2014
(INTERNATIONAL FUEL GAS CO�E 2012
WITH INDIANA AMENDMENTS)
ACCESSIBILITV CODE: INDIANA BUILDING CODE 2014, CHAPTER 11
QCC/AN51 A11 ].1-2008 ACCESSIBLE ANO
USABLE BUILDINGS AND FACILITIES)
CODESUMMARY
BUILDING GROSS SQUARE FOOTAGE:
EXISTWGBUILDING(UNCHANGED) ±9],368GSF
RENOVATION SQUAREFOOTAGE:
TOTAL RENOVATION SF ±13,ID5 USF
CONSTRUCTION TYPE:
E%ISTING: II-B, FULLV SPRINKLED (UNCHANGED)
OCCUPANCY:
OCCUPANCV CLASSIFlCATION:
GROUP B, EXISTING (BUSINESS)
OCCUPANT CALCULATION (FIXED TABLE 10�4.1 2):
RENOVATED SF = 13,105 SF / 100 SF PER PERSON 131 PERSONS
EGRESS:
1005.32 -.15" PER PERSON CAPACITV, SPRINKLERE�
REOUIREO PROVIDED
FIRSTLEVEL-1310CCUPANTSX.15" 19b5" 108"
RRST FLOOR MAXIMUM TRAVEL DISTANCE (TABLE 70162) = 3�0'
(B OCCUPANCV WITH SPRINKLER)
EXISTING CORRIDOR CONSTRUCTION (TABLE 1018.1)
(B OCCUPANCV W ITH SPRINKLER) = NON RATED
MA%IMUM DEAD END CORRIDOR (TABLE 1018 4) = 50'-0"
WALL LEGEND
NOTE:
ALL EXISTING RATED WALLS ARE TO REMAIN. PROTECT DURING
ALL PHASES OF CONSTRUCTION. PATCH AND REPAIR AS
REQUIRED TO MAINTAIN EXISTING RATED CONSTRUCTION.
GENERAL CONTRACTOR TO FIELD VERIFV ALL CONDITIONS.
ALLWALLSINDICATEDAS- � � � � � �-ARETO
BE EXISTING 1-HOUR RATED WALL CONSTRUCTION. FlELD VERIFV
ALLWALLSIN�ICATEDAS-�ii�ii� i�ii�i �-ARETO
BE EXISTING 2-HOUR RATED WALL CONSTRUCTION. FIELD VERIFV
LIFE SAFETY LEGEND
ELECTRICAL PANEL LOCATION
EXIT-BUILDWG STAIR LOCATION
FlRE EXTINGUISHER LOCATION
EXIT SIGNAGE LOCATION
EMERGENCV LIGHTING
------� I PATHOFEGRESS,MAXIMl1MTRAVELDISTANCE
KEY PLAN - FIRST LEVEL I NORTH �
� �
��
�
U �
7 �
o g
O c�, rc e"'�
C e p ¢
� a Y A m x� w
[-. w z �
� � o m
C w � � G
� � w
d o w LL w d.�i�
c
0
o^
rm
oa
n,�
o^
a^
00
No
vm
�Q
�m
a�
oM
� .�
�a
�
0
Z
�
Z
J
d
�
I.L
vi
w
� J
N
0
N
0
, \,�,Y K -"%.
�:: ..$ .....,. .
�� og� ��:
?."� _�< g;
�N �
�Q �... ... •.
H1 ...*.•'..�
�
�
�
w
�
W �
U �
�Z w
� Q �
J
�
Qm J N
O W � �
aU��
O� U Z
�
j0��
w
a �Q � U
Q� w
� a 'o » ,.'
o� � oo`
U
oRnwinc no. sneet oF
A001
TITLE
LIFE SAFETY PLAN
oarE: 06/11 /20
�
i �
�
i
� ��
i
/ ��
�' �� EXISTING
, � EXIT
/ �.