HomeMy WebLinkAboutE0.1-STANDARD-SYMBOL-LEGEND-Rev.00 SYMBOL LEGEND OUTLETS � SINGLE RECEPTACLE W STANDARD DUPLEX RECEPTACLE W� WEATHERPROOF RECEPTACLE W� GROUND FAULT RECEPTACLE W�� ISOLATED GROUND RECEPTACLE WE� ELEC7RIC WATER COOLER Q}� RECEPTACLE ON DEOICATED QRCUIT Qp� RECEPTACLE WITH INIEGRAL USB PORT � DOUBLE DUPLEX RECEPTACLE (QUAD) Q CLOCK RECEPTA0.E 460A SPECIAL EQUIPMENT RECEPTACLE OR CONNECTION Q TWIST LOCK TYPE RECEPTACLE ♦ WALL MOUNTED TELEPHONE O 60" A.F.F. (ROUGH-IN ONLY) � DATA OUTLET (ROUGH-IN ONLY) V DUPLE% COMMUNICATION OUTLET (VOICE & DATA) (ROUGH-IN ONLY) �� POWER POLE (POWER, TELEPHONE, DATA) 0 JUNCTION BOX Oj WALL MOUNTED (POWER) FURNITURE CONNECTION TO PARTI710NS WALL MOUNTE� OATA FURNITURE � CONNECTION TO (PARTI710N5 �PLOOR BOX `MTH DUPLEX RECEPTACLE AN� VOICE��ATA OUTLET �ROOR BO% W1TH DUPLEX RECEPTACLE, VOICE/DATA OUTLET AND A/V OUTLET Q POKE THROUGH DEVICE SWITCHES S SINGLE-POLE SWITCH S� OOUBLE-POLE SWITCH S3 hIREE-WAY SWITCH � - FOUR WAY SWTCH SW COMB. SWITCH/DUPLEX RECEPTACLE � THERMAL OVERLOAD SWITCH SM MANUAL MOTOR SWITCH SK KEY SWITCH S�w WEATHERPROOF 5`MTCH �� MOMENTARY CONTACT SWITCH $o DIMMER SWITCH (WATTAGE SHOWN) � TOGGLE DISCONNECT SWITCH � RAISE/LOWER LTG. ZONE CONIROLLER $�� LOW VOLTAGE PUSHBUTTON SWITCH $os WALL MOUNTED OCCUPANCV SENSOR OS CEILING MOUNTED OCCUPANCY SENSOR PF MOTION SENSOR POWER PACK NOTE DESIGNATIONS m REVISION NOTE � FEEDER NOTE O KEY NOTE LIGHT FIXTURES � 2'x2' LAY-IN FIXNRE � 2'x4' LAY-IN FIXTURE i--�� STRIP FIXNRE -r�- WALL MOUN7ED FIXTURE O PENDANT MOUNTED FIXTURES � NL� NIGHT LIGHT (ON CONIINUOUS) � RECESSED, EMERGENCY FIXTURE Qi RECESSED DOWNLIGHT � RECESSED WALLWASH O SURFACE MOUNTED DOWNLIGHT � EXIT flXNRE (arrows indicates direction of egress) � EXIT FlXNRE, WALL MOUNTED � EXIT Fl%NRE W1TH TW1N HEAD EMERGENCY LIGHTS �7 EMERGENCY EGRE55 LIGHT 7 EMERGENCY REMOTE HEAD ¢ WALL MOUNIED FIXTURE � LIGHT TRACK W/ LIGHT TRACK FI%NRE � DOCK LIGHT o-O POLE FIXTURE .Q GROUND MOUNTED FLOODLIGHT Ti BOLLARO CIRCUITRY and RACEWAYS ---- CONDUIT INSTALLED (UNDER SLAB OR UNDERGROUND) CONDUIT INSTALLED (CONCEALED IN WALL, ABOVE CEILING OR E%POSED) ---- LOW VOLTAGE WIRING CONDUIT UP � CONDUIT DOWN HOME RUN (`M1H PANEL DESIGNATIONS LPt-1,3,5� AND CIRCUIT NUMBERS) � CONDUCTORS (GROUND = LONG LME W/ DOT, NETURAL = LONG LINE, PHASE = SHORT LINE) y12AWG CONDUCTOR SIZE (UNO) 7 END OF RUN, CAP AND STAKE � "RUN CONTINUES" IN�ICATION ��` FLEXIBLE PIGTAILS/CONNECTIONS m PLUGMOLD � BUS WAY TM �" CABLE TRAY FIRE ALARM F❑ PULL STATION F❑� COMBINATION HORN AND STROBE -0s p DUCT DETECTOR SQ SMOKE DETECTOR Q HEAT DETECTOR F.Ao.C.v. FIRE ALARM CONTROL PANEL ��e'''P' FIRE ALARM ANNUNCIATOR PANEL ��E.O.L END OF LINE OEVICE CS]I STROBE ONLY FIRE ALARM DEVICE DH DOOR HOLDER FC FIREFIGHTER COMMUNICATION JACK rs FLOW SWITCH Q TAMPER S`MTCH rry POST INDICATING VALVE QB EXTERIOR BELL BD BEAM DETECTOR BD BEAM DETECTOR REFLECTOR � I) i� � II Ay T x ��[ KVA `-F' � � S � � � ONELWE DIAGRAM SCHEMATIC SYMBOLS CIRCUIT BREAKER 225 FRAME SIZE (AMPERES) 100 = TRIP SETTING (AMPERES) KNIFE SWITCH OR DISCONNECT 5`MTCH FUSE (AMPERAGE SHOWN) FUSED KNIFE SWITCH 3 PHASE MOTOR STAR7ER - NUMBER INDICAlES NEMA SIZE 2 � LETTERS INDICATES STARTER TYPE - FVNR=NLL VOLTAGE NON-REVERSING WNTROL TRANSFORMER POWER TRANSFORMER (KVA SHOWN) AUTOMATIC TRANSFEft SWITCH POTENTIAL VOLTAGE TRANSFORMER CURRENT 7RANSFORMER TNERMAL OVERLOAD (O.L.) LIGHTNING ARRESTER AMMETER VOLTMETER GROUND CONNECTION SERVICE and E UIPMENT Q 0 TRANSFORMER, PAD MOUNTED ❑* TRANSFORMER, DRY TYPE (KVA SHOWNJ � PANELBOARD = LIGHTING CONTROL PANEL O� DISCONNECT SWITCH � COMBINATION STARTER � MAGNE7IC STARTER 8 UTILITY MEIER � CURRENT TRANSFORMER CABINET � GENERATOR ^� TELEPHONE TERMINAL BOARD � AUTOMATC TRANSFER 5`MTCH SOUND and SIGNAL Qs RECESSED CEILING SPEAKER OO VOLUME CONTROL � P.A. HORN 6 BUZZER 8 DOOR BELL � DOOR CHIME O TELEV1510N ANTENNA OUTLET Q MICROPHONE OUTLET �� INTERCOM OUTLET 4 NURSE CALL PULL STATION � NURSE CALL DOME LIGHT � DOOR CONTACT OO KEY PAD cx CARD REAOER � CAMERA MECHANICAL � MOTOR AND CONNECTION, HP SHOWN � CEILING TYPE FAN � PADDLE TYPE FAN � WALL TYPE FAN wwwv PIPE HEAT TRACING �-� UNIT HEATER � ELECTRIC BASEBOARD HEATER O ELECTRIC CEILING HEATER O ELECTRIC WATER HEATER CONTROL QQ THERMOSTAT (LINE VOLTAGE UNO.) QQ HUMIDISTAT (LINE VOLTAGE UNO.) � PHOTOCELL T� TIME CLOCK 0 PUSHBUTTON STATION 0 LIGHPNG CONTACTOR SCHEDULE OF STANDARD MOUNTING HEIGHTS FOR ROUGH-IN OF ELECTRICAL DEVICES � � �1 A. GENERALLY MOUNTING HEIGHTS OF DEVICES ARE TO BE AS FOLLONS: (HEIGHTS GIVEN ARE TO CENTER OF DEVICE BOX) (A.F.F. = ABOVE FINISHED FLOOR) (B.F.C. = BELOW FlNISHED CEILING) 1. RECEPTACLES GENERAL: +1'-6" A.F.F. 2. WALL S'MTCHES, GENERAL: +46" A.F.F. 3. RECEPTACLES OVER WORKBENCHES, TABLES, ETC.: +4'-2" A.F.F. 4. TELEPHONE OUTLETS OVER WORKBENCHES, TABLES, ETC.: +A'-2" A.F.F. 5. TELECOM OUTLETS: +1'-6" A.F.F. (DESK TYPE) 6. WALL TELEPHONE OURETS: +5'-0" A.F.F. 7. WALL PUSHBUTTONS: +4'-0" A.F.F. 8. MOTOR CONTROLLERS: +4'-0" A.F.F. 9. DISCONNECT SWITCHES: +6'-0" A.F.F. 10. FIRE ALARM PULL STATIONS: +4'-0" A.F.F. 11. FIRE ALARM HORNS, BELLS, GONGS: +80" A.F.F. OR 12" B.F.C. 12.THERMOSTATS: +4'-fi" 13.RECEPTACLES/DE�10E5 MOUN7ED ABOVE COUNTERTOP BACKSPLASH: +2' (MIN.) 14.RECEPTACLES/DE�10E5 MOUN7ED ABOVE RADIANT HEAlERS: +6" (MIN.) 15. WALL MOUNTED SPEAKERS: +8'-0" A.F.F. OR 12' B.F.C. 16. CARD READER: +3'-6' A.F.F. 17. EMERGENCV LIGHTING UNITS: (OFFICE) +7'-0' A.F.F. OR 12" B.F.C. (WAREHOUSE) +12'-0' A.F.F. i8. WALL MOUNTED, STAIRWELL LANDING, LIGHT FIX7URE5: +7'-0" A.F.F. 19. PANELBOARDS: 6'-0" A.F.F. RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �{�n„� i,.va�� oarE: 06/11 /20 B. EXCEPPONS TO REQUIREMENTS OF SCHEDULE: 1. AT JUNCTION OF DIFFERENT MATERIALS IN WALL FINISHES. 2. WHERE OUTLETS WOULD OCCUft IN MOLDINGS, BREAK IN WALL SURFACE OR UNSWTABLE LOCATION IN PLE WOOD OR SIMILAR FINISH. 3. WHERE OUTLETS WOULD CONFLICT W17H LOCA710N5 OF WALL MOUNTED EQUIPMENT, SUCH AS RADIATORS, CONVECTORS, UNIT HEAIERS, ETC. 4. AS NOTED OR INDICATED OTHERWISE ON DRAWINGS OR IN SPEQFlCAlI0N5. G SCHEDULE NOTES: 1. MOUNTING HEIGHTS ARE ABOVE FINISHED FLOOR TO CENTER OF OURET (DEVICE) BOX, UNLESS OTHERWISE NOTED OR INDICATED ON THE DRA`MNGS OR SPEQFlCATIONS BY SPEQFlC NOTES OR DETAILS. 2. REFER TO ELECTRICAL SPECIFICAPONS FOR ADDI110NAL INFORMATION ON DEVICE/OUTLET BOX INSTALLA710N REQUIREA�ENTS. 3. GENERAL REqUIREMENTS FOR OURET/DEVICE BO% INSTALLATION IN CONCRElE BLOCK OR TILE WALLS: A. IT IS INTENDED THAT OURET/DEVICE B0J(ES SHALL BE SET ON TOP OF A BLOCK (TILE) COURSE BELOW, WIIH THE OUTLET SPACE WT INTO THE BOTTOM OF THE BLOCK (TLE) COURSE ABOVE. B. OUTLETS SHALL BE INSTALLED IN NEAREST BLOCK (TILE) COURSE TO THE SCHEDULED MOUNTNG HEIGHT. 4. SPECIAL PURPOSE DEVICES (THOSE SERVING COMMERCIAL KITCHEN EQUIPMENT, ELECTRIC WATER COOLERS, APPLIANCES, ETC.) SHALL BE IN AGREEMENT WITH APPROVED SHOP DRAINNGS. 5. TOGGLE TVPE SWITCHES, uGHT SWITCHES, AND MANUAL MOTOR STARTERS, MOUNTED ABOVE BACKSPLASH OF COUNTERTOPS SHALL BE MOUNTED AT SAME HEIGHT AS RECEPTACLES. 6. COORDINATE DEVICE MOUNTING HEIGHTS WITH ARCHITECTURAL CASEWORK SHOP DRAWINGS. D. AMERICANS W1TH DISABILITIES ACT (ADAJ NOTES: (FAqLITIES COMPLIANCE WORKBOOK) CHAPTER 11 OF 7HE 2014 INDIANA BUILDING CODE - INDIANA ACCESSIBILIN CHAPTER 1. OPERATING CONTROLS: INCWDING BUT NOT LIMITED TO RECEPTACLES, SWITCHES, WALL MOUNTED IELEPHONES, ETC. A. MOUNl1NG HEIGHTS ARE TO HIGHEST OPEftABLE PART OF THE CONTROL AND SHALL BE PLACED YAhiIN AT LEAST ONE OF THE REACH RANGES SPEqFIED IN ARTICLE 4.2.5 AND 4.2.6 OF CHAPTER 17 IN THE INDIANA BUILDING CODE - INDIANA ACCESSIBILITY CHAPTER. (1) MOUNIING HEIGHTS OF THE ABOVE MENTIONED CON7ROL5 ARE TO BE CONSIDERED FROM TWO (2) VANTAGE POINTS AS FOLLOWS: a. FORWARD REACH - IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TO AN OBJECT, BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL BE +48' AEF. AND THE MINIMUM LOW FORWARD REACH ALLOWED SHALL BE +15" A.F.F. IF THE FORWARD REACH IS OVER AN OBJECT THEN THE MAXIMUM HIGH SIDE REACH SHALL BE ADJUSIED ACCORDING TO AR7ICLE 4.2.5 RG. 5 b OF CHAPTER 11 IN THE �) INDIANA BUILDING CODE - INDIANA ACCESSIBILIN CHAPTER. b. SIDE REACH - IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED SHALL BE +54" A.F.F. AND 7HE MINIMUM LOW REACH SHALL BE NO LESS THAN +15" A.EF. IF THE SIDE REACH IS O�ER AN OBJECT, THEN THE MA%IMUM HIGH SIDE REACH SHALL BE ADJUSTED ACCORDMG TO ARTICLE 42.6 FIG 6(c) OF CHAP7ER 11 IN lHE INDIANA BUILDING CODE - INDIANA ACCESSIBILITY CHAPTER. 2. IF CONTROLS, DISPENSERS, RECEPTACLES, OR OTHER EQUIPMENT ARE PROVIDED (IN BAhiR00MS, BAhiING FACILITIES, AND SHOWER ROOMS), THEN AT LEAST ONE OF EACH' SHALL BE ON AN ACCESSIBLE ROUiE, AND SHALL COMPLV `MTH ARTICLE 4.27 OF THE FEDERAL REGISTER/VOL 58, N0. 144/FRIDAY, JULY 26, 1991/RULES AND REGULATIONS. 3. ALARMS: ARIICLE 425 A. MOUNTNG HEIGHTS OF V15UAL ALARMS SHALL BE PLACED AT 80" ABOVE THE HIGHEST FLOOR LEVEL YnhilN THE SPACE, OR 6' BELOW 1HE CEILING, WHICHEVER IS LOWER. ARTICLE 425.3 SUB ARTICLE (f). 4. PROTRUDING OBJECTS: ARTCLE 4.{ (WALL SCONCES, HANO DRVERS, ETC.) A. GENERAL OBJECTS PROJECTING FROM WALLS Wlhi THEIR LEADMG EDGES BETWEEN +27" A.F.F. AN� +80" A.F.F. SHALL PROiF2UDE NO MORE THAN FOUR (4) WCHES INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES. PROTRUDING OBJECTS SHALL NOT REDUCE 7HE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. GENERALNOTES APPLY TO ALL ELECTRICAL SHEETS 1. THE ELECTRICAL CONTRACTOR SHALL PRONDE ALL REOUIRED LABOR, MATERIAL, E�UIPMENT, AND SERVICES NECESSARY TO COMPLETE TNE INSTALLATON OF ALL SYSTEMS INDICATED. lHE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL, INCLUDING ANY AND ALL ITEMS REQUIRED FOR A FULLY FUNCTIONING SYSIEM. 2. ALL MATERIALS AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, U7ILITY COMPANY REGULAPONS, AND NATIONALLY RECOGNIZED CODES AND STANDARDS. 3. NATIONAL ELECTRICAL CODE (NEC) AND INDUSTRY INSTALLATION STANDARDS SHALL BE CONSIDERED MINIMUM STANDARDS. 4. ALL ELECIRICAL E�UIPMENT SHALL BE UL LISTED AND LABELED. 5. VERIFY ALL DIMENSIONS FROM ARCHITECNRAL PLANS. 6. DIMENSIONS SHOWN ON OURET BOXES SHALL BE FROM THE FINISHED FLOOR TO THE CENTER OF THE BOX. 7. ALL CONDUITS AND BOXES SHALL BE PROPERLY SUPPORTED. 8. ALL NECESSARV HANGERS AN�/OR MOUNTING ACCESSORIES FOR LIGHPNG FIXTURES SHALL BE SUPPLIED BY EC. 9. ALL GRS OR IMC CONDUITS EN7ERING BOXES OR ENCLOSURES W17HOUT HUBS SHALL BE EQUIPPED `MTH BUSHINGS, AND SHALL HAVE LOCKNUTS INSIDE AND OUT OF ENCLOSURE. 10. VERIFY ELEC7RICAL CHARACTERISTICS AND ROUGH-IN REQUIREMENTS FOR ALL ELECTRICAL EOUIPMENT FURNISHED BY OTHERS AND CONNECTED BY E.C. 11. COOftDINATE LOCATION OF LIGHTS IN ROOMS CONTAINING EXPOSED DUCTWORK AND PIPING BY O1HER TRADES. 19. ALL DISCONNECT S`MTCHES LOCATE� OUTDOORS SHALL BE NEMA 3R (U.N.O.) 20. ALL DISCONNECT 5`MTCHES LOCATED INDOORS SHALL BE NEMA 1 U.N.O.) 21. ALL DISCONNECT SWITCHES LOCATED IN CORROSIVE ATMOSPHERES SHALL BE NEMA 4X (U.N.O.) 22.00 NOT LOCATE BOXES BACK TO BACK IN WALL PARTITIONS. STAGGER AS REOUIRED TO MINIMIZE SOUND TRANSMISSION. 23. COORDINATE THE SERVICE INSTALLATION W1lH THE UPLITY COMPANV. INSTALL METER CABWET PRO�IDED BY 1HE UT1uN COMPANV IN ACCORDANCE `MTH THE UTILITY COMPANYS STANDARDS. 24. Pft0�1DE ALL GROUNDING AS REQUIRED TO MEET THE UTILITY AND NEC SECTION 250 REQUIREMENTS. 25.MATERIALS SHALL BE RECEIVED AND STORED IN A MANNER TO BEST PROTECT THE MAIERIALS PRIOR TO INSTALLATION. PROTECIIVE COVERS SHALL REMAIN IN PLACE AS MUCH AS POSSIBLE. 26. ALL E�UIPMENT AND DEVICES SHALL BE INSTALLEO IN A PROFESSIONAL AND WORKMANSHIP MANNER, AND IN COMPLIANCE `MTH NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION (NECA) RECOMMENDED STANDARDS. 27.HANGERS AND SUPPORTS SHALL BE USED AS REQUIRED TO PROPERLY AND FULLY SUPPORT ALL ELECTRICAL MAIERIALS AND EQUIPMENT IN A PERMANENT MANNER. 28. ALL MATERIALS AND EQUIPMENT SHALL BE OF THE TWE DESIGNED, AND SUITABLE FOR THE MANNER IN WHICH THEY ARE W STAI I F�. 12. COORDINATE LOCATION OF MOTOR STARTERS, DISCONNECTS, p9, EQUIPMENT SHALL BE INSTALLED LEVEL, PLUMB, AND TRUE WITH PANELBOARDS. ETC. IN ROOMS CONTAINING EXPOSED DUCPNORK THE STRUCTURE AND OTHER EQUIPMENT, AND INSTALLED IN A AND PIPING BY OTHER TRADES. HORIZONTAL OR VERTICAL POSITION AS INTENDED. 13. VERIFY HEIGHT AND LOCATION OF OUTLETS BEHIND WATER 30.ROUTE RACEWAYS PARALLEL OR PERPENDICULAR TO BUILDING COOLERS `MTH OTHER TRADES, 50 OUTLETS ARE CONCEALED. SURFACES OR EXPOSED STRUCTURAL MEMBERS, AND FOLLOW SURFACE CONTOURS IN ORDER TO PRESENT A NEAT 14. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND NOTES APpEARANCE. CONCERNING ITEMS INVOLVMG ELECTRICAL WORK. 31. GROUP RACEWAYS WHERE POSSIBLE AND COMPLY WI7H 15. REFER TO ARCHITECTURAL RERECTED CEILING PLAN FOR CEILING RECOMMENDED SPACING STANDARDS. TVPES AND FlXTURE LOCATIONS. ANY CONFLICTS BETN'EEN ELECTRICAL PLANS AND REFLECTED CEILING PLANS SHALL BE 32.ALL WiRE AND CABLE SHALL BE SUITABLE FOR 1HE REPORTED AND RESOLVED PRIOR TO ROUGH-IN. TEMPERATIRE, CONDITIONS, AND LOCATIONS WHERE 7HEY i6. REFER TO ARCHITECTURAL PLANS FOR FINAL DOOR SVANG AND ARE INSTALLED. LIGHT SWITCH LOCATIONS. ANY CONFLICT BETWEEN ELECTRICAL 33. TAKE ALL NECESSARY PRECAUTIONS KHEN PULLING WIRE AND AND ARCHITECNRAL PLANS SHALL BE REPORTED AND RESOLVED CABLES TO PRE�ENT DAMAGE TO 7HE INSULATION. PRIOR TO ROUGH-IN. 17. REFER TO ARCHITECTURAL PLANS FOR ELEVATIONS OF CASEWORK 34'ALL CONDUCTORS TO BE PULLED IN A RACEWAY SHALL BE AND/OR BUILT-W SHELNNG UNITS TO COORDINATE OUTLET PULLED TOGETHER. ELEVATIONS. ANY CONFLICT BETNEEN ELECTRICAL AND 35. KEEP CONDUCTOR SPLICES TO A MINIMUM. ARCHITECTURAL PLANS SHALL BE REPORTE� AND RESOLVED PRIOR TO ROUGH-IN. 18. ALL FEEDERS AND BRANCH QRWITS RAN UNDERGROUND IN PVC CONDUIT SHALL INCWDE A GROUND CONDUCTOR. ELECTRICAL ABBREVIATIONS A AMPERE(5) GALV GALVANRED NEMA NATIONAL ELEC421CAL TI GF GROUND FAULT MANUFACTURERS ASSOCIAPON AC ALTERNA NG CURRENT AFF ABOVE FINISHED FLOOR GFI GROUND FAULT IN7ERRUPTER NEC NAPONAL ELECTRICAL CODE AL ALUMINUM GFP GROUND FAULT PROTECTION NF NON-FUSED AMP AMPERE(5) GND GROUND NTS NOT TO SCALE ATS AUTOMATIC TRANSFER SWITCH HH HANDHOLE OL OVERLOAD BLDG BUILDING HID HIGH INTENSITY DISCHARGE 2P TWO POLE BKR BREAKER HOA HAND-OFF-AUTOMATIC PB PUSHBUTTON C CONDUIT HOR HAND-0FF-REMOTE PVC POLYNNYL CHLORIDE 2/C PNO WNDUCTOR (TYP) HOAR HAND-0FF-AUTO-REMOTE RGS RIGID GALVANRED STEEL CB CIRCUIT BREAKER HP HORSEPOWER SP SINGLE POLE CKT CIRCUIT HPS HIGH PRESSURE SODIUM SPDT SINGLE POLE DOUBLE IHROW CPT CONTROL POWER IRANSFORMER IMC INTERMEDIATE METAL CONDUIT SPEC SPEQFlCA710N CPU COMPUTER JB JUNCTION BO% SPST SINGLE POLE SINGLE 7HROW CR CONTROL RELAY KV KILO VOLTS SlR STARTER CT CONTROL TRANSFORMER KVA KILO VOLTS-AMPS SW SWITCH CU COPPER KVAR KILOVAR T7g TELEPHONE TERMINAL BOARD DISC. DISCONNECT LA LIGHTNING ARRESTOR Typ TWICAL DT DUST TIGHT LTG LIGHTING UNO UNLE55 NOTED OTHER`MSE LOR LOCAL-0FF-REMOiE DWG DRAWING UL UNDERWRITERS LABORATORIES EF EXHAUST FAN MS MAGNE�C MOTOR STARTER COIL V VOLTS ELEV ELEVATION MAX MA%IMUM VFD VARIABLE FREQUENCY DRIVE EM EMERGENCY MCC MOTOR CONTROL CENTER VS VOLTMETER SWITCH EQUIP EOUIPMENT MD MOTORIZED DAMPER y� W�RE OR WATT EWC ELECTRIC WATER COOLER MFR MANUFAC7URER y�� W�TH MH MANHOLE EP EXPLOSION PROOF W/0 WITHOUT FMC FLEXIBLE METALLIC CONDUIT MIN MINIMUM y/p y/EqTryERPR00F FMIR FULL-VOLTAGE NON-RE�ERSING N NEUTRAL XFMR 1i2ANSFORMER FVR FULL-VOLTAGE REVERSING N/A NOT APPLICABLE XFR TRANSFER GROUND 0 PHASE d � C . b � � � � � Qa � � � � 0 � o g � o o � � w � a � p . v x�� F J z E Q V Q n V Z � � o w < � � � �O o � O �v_ F O N 7a� V �ZX '¢ LL w LL J � i � J O W ,L�o /W, �n w � N J � N m �ON � Z • r � m �a N M L K J H �wwmnnmm�uuiy: _ 1 s+" N • aa�N �vi4� � ���_���iy ' ° z°oa si `�?;� z�o .., � � ���h�� _ ���/' � pR�F�,,�aS - MpMuuiniinumxM^' G � z /�.��..� V w J J O mc G � � Q � z Q � � W U C� �Z � 00 � J 0 � w W O aU � v O� U Z U�H� Qi�w w � �O � � a �Q � U F E � �w D QU a r� O 6lll �� z Q z0 U O O °� O - - � 0 C � i � � a� i B ]RAWING N0. SHEET OF E0.1 °T`E: STANDARD SYMBOLLEGEND �