Loading...
HomeMy WebLinkAboutE2.0 ELECTRICAL LIGHTING PLAN2 01 D C8'-8"+/-B 102 DRIVE THRU 101 POS MAIN 103 METAL PROGETTI 104 MANAGER AREA 105 BREAK ROOM 106 DELIVERY 107 EXIST. RESTROOM SCALE: 1/4" = 1'-0" 1 E2.0 ELECTRICAL LIGHTING PLAN GENERAL NOTES: (APPLY TO THIS SHEET ONLY) 1. SEE ARCHITECTURAL RCP FOR EXACT LIGHTING FIXTURE LOCATIONS AND FOR CEILING TYPE. FIXTURE 'B' SHALL BE COORDINATED WITH CEILING TO BE INSTALLED 2. SITE LIGHTING SHALL BE PROVIDED ON A CASE BY CASE BASIS. ALL NON-BUILDING MOUNTED SITE LIGHTING SHALL BE CONTROLLED VIA A BUILDING MOUNTED PHOTOCELL - WHICH SHALL BE LOCATED ON THE BUILDING FACING NORTH CLEAR OF OBSTRUCTIONS. EXTERIOR LIGHTING LOADS SHOWN ON PANEL SCHEDULES ARE PLACE HOLDERS AND SHOULD UPDATED FOR DESIGN. 3. ALL EMERGENCY FIXTURES SHALL HAVE A HOT CONNECT TO BATTERY BALLAST AHEAD OF SWITCH LEG. 4. ALL LIGHTING LOCATIONS ARE SUBJECT TO CHANGE AND NEED TO BE VERIFIED WITH EQUIPMENT INSTALLER BEFORE THEY ARE PERMANENTLY ATTACHED. LIGHTING NOTES: (APPLY THIS SHEET ONLY) FIXTURE SHALL BE UNSWITCHED. REFER TO 3/E2.0 FOR LIGHT SWITCH BANK DETAIL. PROVIDE AND INSTALL LABEL ON EACH SWITCH NOTING THE AREA AND LIGHTS THAT EACH SWITCH CONTROLS. ALL FIXTURES SHALL BE CONTROLLED VIA TIME CLOCK, SEE 2/E2.0. MOUNT BOTTOM OF FIXTURE AT 7'-6" AFF. INSTALL BOTTOM OF LIGHT FIXTURE AT 12'-0" AFF. LEAVE 1'-0" LOOP ON WIRE AND CHAINS FOR ADJUSTMENTS. EXISTING AREA FIXTURES CONTROLLED AND POWERED BY THE LANDLORD. EXISTING LANDLORD PROVIDED WALL PACKS TO BE SWITCHED SO THE WALL PACK WITH BATTERY BACKUP IS LOCATED ABOVE THE DOUBLE DOORS. FIXTURES SHALL BE DISCONNECTED, RELOCATED, AND RECONNECTED AS REQUIRED. COORDINATE ALL WORK WITH LANDLORD. L1 L2 L3 L4 L6 L7 L8 TC A-19 A-21 DUAL CHANNEL TIME CLOCK, TORK 'DWZ100B' OR EQUAL A-17 A-12 SALES/LOBBY AREA LTG BOH AREA LTG CONVEYOR LTG SPARE SPARE SPARE EXTERIOR SIGNAGE a b c 1. INSTALL SWITCH BANK IN COMMON COVER PLATE. DETAIL NOTES: (APPLY TO THIS DETAIL ONLY) SPARE SPARE a c b 6-POLE NEMA 1 LIGHTING CONTACTOR, 30A, 600V CONTACTS, 120V COIL, MOMENTARY CONTACT, MECHANICALLY HELD 4-POLE NEMA 1 LIGHTING CONTACTOR, 30A, 600V CONTACTS, 120V COIL, MOMENTARY CONTACT, MECHANICALLY HELD CE BE/NL C C C C C C B B B B B XLC X1 A-19 A-19 X1 A-21 XLC A-21 A-19 VIA SWITCH "c" A-21 VIA SWITCH "a" CE/NL CE/NL CE/NL CE/NL BE/NL L1 (TYP) L2 TCTC L3 X2 A-17 A-23 CE A-23 A A F L4 F L4 F L4 F F X2 A-17 X2 A-17 L4 L4 A-17 VIA SWITCH "b" A A A A A L6 L6 L6 L6 L6 L6 L6 L6 L6 SCALE: NONE 3 E2.0 LIGHT SWITCH BANK DETAIL SCALE: NONE 2 E2.0 LIGHTING CONTROL SCHEMATIC SPARE L7 L8 B ELECTRICAL LIGHTING PLAN XXX EJR KEY PLAN ISSUE DATE THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. PROJECT INFORMATION CERTIFICATION ISSUE DATES NORTH F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 N T E S E N G I N E E R I N G Cleveland, OH 44145 25760 First Street P 440 871 2410 F 440 871 7954 tesengineering.com DRAWN BY: ________ CHECKED BY: ________ PROJECT NUMBER: 200079 TIDE CLEANERS 2801 E. 116TH STREET CARMEL, INDIANA 46033 DROP STORE E2.0 AREA OF WORK 06/04/2020 09/24/20