HomeMy WebLinkAboutM0.I MECHANICAL LEGEND & DETAILS1
T
RISE
POINT OF CONNECTION - NEW TO EXISTING
TURNING VANES
INCLINED RISE IN DUCT
IN-LINE 90 DEGREE RISE IN DUCT
RETURN OR EXHAUST AIR DUCT DOWN
DUCTWORK SIZE TRANSITION
RETURN OR EXHAUST AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
HVAC SYMBOLS
20/12
12"Ø
SUPPLY OR OUTSIDE AIR DUCT
90 DEGREE DUCTWORK ELBOW W/ TURNING VANES
ROUND OR RECTANGULAR
RECTANGULAR DUCTWORK BRANCH TAKE-OFF
HIGH EFFIECENY "BUCKLEY" TAP WITH DAMPER
RADIUS DUCTWORK ELBOW -
WITH 45 DEGREE BRANCH INLET
DIFFUSER/GRILLE LABEL:
B - NECK SIZE (INCHES)
A - TYPE/DESIGNATION
C - AIRFLOW (CFM)
RETURN, RELIEF OR EXHAUST AIR DUCT
PATTERN. NO PATTERN SHOWN EQUALS 4-WAY
FIRST NUMBER IS SIDE SHOWN
ROUND DUCTWORK. DIAMETER IN INCHES
RECTANGULAR DUCTWORK. SIZE IN INCHES,
SUPPLY AIR DIFFUSER - SHADING INDICATES
RETURN OR EXHAUST AIR GRILLE
OR AS NOTED
MANUAL VOLUME DAMPER
THERMOSTAT
SD
DRAWING NOTE REFERENCE
OVAL OR FLAT OVAL
ROUND
DUCT SMOKE DETECTOR
H HUMIDISTAT
S SENSOR
F
FIRE DAMPER
C CARBON DIOXIDE SENSOR
UNDERCUT DOOR 3/4" FOR AIRFLOWUC
INTERNALLY LINED DUCTXX/XXL
IN-LINE 90 DEGREE DROP IN DUCT
MOTORIZED DAMPER
MD
ABBREVIATIONS
ENTERING WET BULBEWB
TSTAT THERMOSTAT
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORIES, INC.
MAXIMUM OVER CURRENT PROTECTION
MAKE-UP AIR
MECHANICAL
MANHOLE, METAL HALIDE
MANUFACTURER
MINIMUM
MOUNTED
MOTORIZED DAMPER
MOTOR CONTROL CENTER
MTD
MUA
MECH
MFR
MOCP
MIN
MH
MCC
MD
LEAVING WATER TEMPERATURE
LOCKED ROTOR AMPS
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPACITY
MAXIMUM
LIGHTING
LEAVING WET BULB
LEAVING DRY BULB
LOW PRESSURE
LEAVING AIR TEMPERATURE
INTERNALLY LINED
POUNDS
LWB
LWT
MAX
MCA
MBH
LTG
LBS, #
L
LAT
LRA
LDB
LP
HEIGHTH
KILOVOLT-AMPS
KILOWATT-HOUR
KILOWATTS
KVA
KWH
KW
HEAD, HUB DRAIN
HAND-OFF-AUTOMATIC
HORSEPOWER, HEAT PUMP
HUMIDISTAT
HEATER
HEATING
HEATING, VENTILATING & A/C
HYDRANT
DOMESTIC HOT WATER
HERTZ
HVAC
HYD
HW
HZ
HSTAT
HTR
HTG
HOA
HD
HP
ELECTRICAL CONTRACTOR
GALLON
GALVANIZED
GENERAL CONTRACTOR
GROUND FAULT INTERRUPTER
GALLONS PER MINUTE
GALLONS PER HOUR
GALLONS PER DAY
GAUGE
GREASE WASTE
GFI, GFIC
GPD
GPM
GPH
GW
GAL
GALV
GC
GA
DEGREES FAHRENHEIT
FOOT, FEET
ENTERING WATER TEMPERATURE
EXISTING
FIRE ALARM
FIRE DAMPER
FLEXIBLE
FEET PER MINUTE
FULL LOAD AMPS
FLOOR CLEANOUT
FIRE ALARM CONTROL PANEL
EXHAUST
°F
FT
FACP
FLEX
FPM
FCO
FD
FLA
FA
EX
EWT
EXH
EC
VARIABLE AIR VOLUMEVAV
W/
W/O
WB
WC
W
VD
VTR
WITH
WET BULB
WATER COLUMN
WITHOUT
VENT THROUGH ROOF
VOLUME DAMPER
WATT, WIDTH
VAC
VA
UON
U/F
U/G
U/S
UL
TYP
VOLT-AMPERE, VALVE
VACUUM
VOLT, VENT
UNDERGROUND
UNDERSLAB
UNDERFLOOR
TYPICAL
SQUARE FEET, SQUARE FOOT
SMOKE DETECTOR, STORM DRAIN
REVOLUTIONS PER MINUTE
SHEET METAL & A/C CONT NAT'L ASSOC.
TOTAL STATIC PRESSURE
STORM WATER
POST INDICATOR VALVE
POUNDS PER SQUARE INCH
PRESSURE RELIEF VALVE
REFLECTED CEILING PLAN
REINFORCING, REINFORCED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MFR'S ASSOC.
NATIONAL FIRE PROTECTION ASSOC.
NOISE CRITERIA
OUTSIDE STEM AND YOKE
OCCUPATIONAL SAFETY &HEALTH ADMIN.
OPPOSED BLADE DAMPER
OUTSIDE AIR (VENTILATION AIR)
TENANT EXHAUST (TOILET)
AMERICAN WATER WORKS ASSOC.AWWA
RL REFRIGERANT LIQUID
EXTERNAL STATIC PRESSURE
ELECTRICAL
ELEVATION
EQUIPMENT
ENCLOSURE
ENTERING DRY BULB
ENTERING AIR TEMPERATURE
DIRECT EXPANSION
DRAWING
EACH
DIRECT DIGITAL CONTROL
ESP
ENCL
ELEC
EQUIP
EDB
ELEV
EA
EAT
DX
DWG
DDC
DOMESTIC COLD WATER
DOWNSPOUT
DECIBEL
DIAMETER
DEGREES
DRY BULB
DEGREES CELSIUS
DISCONNECT
DIMENSION
DOWN
DS
DIA (OR Ø)
DN
DISC
DIM
CW
°C
dB
DEG
DB
SPEC SPECIFICATION
TE
THRU
TP
TSP
TDH
STD
SUSP
SURF
ST
SQ
TOTAL DYNAMIC HEAD
THROUGH
TOTAL PRESSURE
SUSPEND
STANDARD
SURFACE
SQUARE
SMACNA
SM
SP
SECT
SHT
SF
SD
RS
SA
RPM
RLA
SHEET METAL
STATIC PRESSURE
SECTION
SHEET
REFRIGERANT SUCTION
SUPPLY AIR
RUNNING LOAD AMPS
CONCRETE
CIRCUIT
CENTERLINE
CIRCULATING
COLUMN
CLEANOUT
CEILING
CUBIC FEET PER MINUTE
CUBIC FEET PER HOUR
CKT
L
CLG
COL
CO
C
CC
CIRC
CFM
CFH
ASSEMBLYASSY
RECIRC
RD
REQ
REV
RHG
RH
REINF
RCP
RA
ROOF DRAIN
REFRIGERANT HOT GAS
REQUIRED
REVISION, REVISE
RELATIVE HUMIDITY
RECIRCULATE
RETURN AIR
PRV
PSI
PH, Ø
PIV
PLBG
PD
PLUMBING
PRESSURE DROP
PHASE
AMERICAN NAT'L STANDARDS INSTITUTE
AIR CONDITIONER, AIR CONDITIONING,
AMERICAN SOCIETY OF TESTING & MATLS
AMERICAN SOCIETY OF MECHANICAL ENGRS
REFRIGERATION & AC ENGINEERS
AIR CONDITIONING & REFRIG INSTITUTE
ABOVE FINISHED GRADE
AMP, AMPERE
AUXILIARY
AMERICAN SOCIETY OF HEATING,
ARCHITECT, ARCHITECTURAL
AMERICAN WELDING SOCIETY
AMERICAN WIRE GAUGE
AIR PRESSURE DROP
ADJUSTABLE
ABOVE FINISHED FLOOR
ABOVE FINISHED CEILING
ARI
ASME
ASTM
AUX
AWG
AWS
ASHRAE
AFG
ARCH
A
ANSI
APD
ADJ
AFF
AFC
AIR COOLED CONDENSING UNIT
AIR COOLED CHILLER
ABOVE
ACCU
ACC
ABV
A/C
OBD
OS&Y
OSHA
OD
OC
OA
NFPA
NTS
N.O.
NIC
OVERFLOW DRAINAGE, OUTSIDE DIAMETER
ON CENTER
NOT TO SCALE
NORMALLY OPEN
NOT IN CONTRACT
NEC
NEMA
N/A
NC
NOT APPLICABLE
EXISTING TO REMAINETR
REX REMOVE EXISTING
CLEANOUT PLUGCOP
OVERFLOW ROOF DRAINORD
RWC RAIN WATER CONDUCTOR
ABOVE CEILING
ACOUSTIC LININGAL
BOTTOM OF PIPE
BUILDING
BRITISH THERMAL UNIT
BOTTOM OF STRUCTURE
BOTTOM OF DUCT
BOILER FEED WATER
BACKDRAFT DAMPER
BUILDING AUTOMATION SYSTEM
BLDG
BOP
BOS
BTU
BOD
BAS
BFW
BDD
BELOW FLOOR
BUILDING MANAGEMENT SYSTEMBMS
DOMESTICDOM
FIRE PROTECTIONFP
FILTERED WATERFW
GROUNDGRD
MECHANICAL CONTRACTORMC
OVERHEADO/H
OPENINGOPNG
REL RELOCATED
SAN SANITARY
DEPTHD
GASG
CONDENSING WATER RETURN/SUPPLYCWR/CWS
CONNECT, CONNECTIONCONN
COMBUSTION AIRCA
TWR/TWS TOWER WATER RETURN/SUPPLY
CHILLED WATER RETURN/SUPPLYCHWR/CHWS
NORMALLY CLOSEDN.C.
PB PUSH BUTTON
HEATING HOT WATER RETURN/SUPPLYHHWR/HHWS
DOMESTIC RECIRCULATED HOT WATERHWR
B/F
CONNECT TO EXISTINGCTE
FINISHED FLOORFF
RR REMOVE AND RELOCATE
INSIDE DIAMETERID
INVERT ELEVATION
INCH, INCHES
INCHES OF WATER COLUMNIN WC
IN
IE
V
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
(ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
A B
C
MAX. 12" TO
BRANCH
CONNECTION
DETAIL NOTES
1. DO NOT LOCATE DAMPERS ABOVE DRYWALL/INACCESSIBLE CEILING LOCATIONS.
LAY-IN CEILING
INSULATED FLEXIBLE CONNECTION
IN VERTICAL ONLY (MAX. 5')
METAL OR VINYL ADJUSTABLE
STRAP CLAMP (TYP 2 PLACES)
GALVANIZED ELBOW
GALVANIZED SHEET
METAL DUCT
SUPPLY AIR DIFFUSER
VOLUME DAMPER IF
INDICATED ON PLAN
1-1/2" THICK FIBERGLASS
INSULATION W/ FOIL FACING
SCALE: NONE
1
M0.1
CEILING DIFFUSER MOUNTING DETAIL
RECTANGULAR TO ROUND
"BUCKLEY FITTING"
RECTANGULAR TO RECTANGULAR
RECTANGULAR
DUCTWORK
RECTANGULAR
DUCTWORK
VARIES
4"
ROUND
DUCTWORK
LOW-LOSS TEE FITTING OR SADDLE
MINIMUM TAKE OFF
AREA 1.25 TIMES
BRANCH DUCT AREA
BRANCH DUCT HEIGHT
DIMENSION 2" LESS THAN
MAIN DUCT HEIGHT DIMENSION
SCALE: NONE
2
M0.1
DUCT BRANCH TAKE-OFF DETAIL
END VIEW
18"MIN
18" MIN
SIDE VIEW
DETAIL NOTES
1. PROVIDE SEISMIC/HURRICANE RESTRAINTS WHEN REQUIRED BY CODE. SEISMIC/HURRICANE
RESTRAINTS SHALL BE FURNISHED BY ROOFTOP UNIT MANUFACTURER AND INSTALLED BY
CONTRACTOR. RESTRAINTS SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO EACH CORNER OF ROOF
CURB.
SA
RA
ROOF TOP UNIT
SEAL BETWEEN ALL DUCTS AND ROOF
DECK WITH ACOUSTICAL SEALANT
FLEX CONNECTION
VERTICAL SUPPLY AIR DUCT
SHALL BE FULL SIZE OF UNIT
OPENING, TRANSITION TO DUCT
SIZE INDICATED ON PLAN
DUCT TRANSITIONS SHALL BE
MADE WITH A MAXIMUM ANGLE
OF 15° AND A MINIMUM OF 18" IN
LENGTH
COORDINATE FINAL BOTTOM OF DUCT ELEVATION
WITH STRUCTURAL MEMBERS, CEILING, LIGHT FIXTURES,
OTHER TRADES, ETC. OR AS NOTED ON PLANS
1" ACOUSTICAL LINER
(IF SHOWN ON PLANS)
DUCT TRANSITIONS SHALL BE
MADE WITH A MAXIMUM ANGLE
OF 15° AND MINIMUM OF 18" IN
LENGTH
PROVIDE FLEX CONNECTION
BELOW ROOF DECK FOR
SUPPLY AND RETURN AIR DUCT
DROPS
ROOFTOP UNIT
SEAL BETWEEN ALL DUCTS
AND ROOF DECK WITH
ACOUSTICAL SEALANT
PROVIDE ELBOW WITH DOUBLE
THICKNESS TURNING VANES FOR ALL
RECTANGULAR CHANGES OF DIRECTION
DUCT MOUNTED SMOKE DETECTOR
PROVIDE RETURN AIR
OPENING ON TOP OF
RETURN AIR DUCT
SEISMIC/HURRICANE RESTRAINT
(TYPICAL AT 4 LOCATIONS, REFER
TO DETAIL NOTE 1)
1" INTERNALLY LINED
RETURN AIR DUCTWORK
SCALE: NONE
6
M0.1
RTU SECTION DETAIL
FULL RADIUS ELBOW RECTANGULAR ELBOW
DIVERGING FLOW CONTRACTING FLOW
W
W
WW
W
W
FULL RADIUS WHERE
POSSIBLE (R = W)
30° MITERED ELBOWS
45° MAXIMUM
LOW VELOCITY ELBOWS
RECTANGULAR TO RECTANGULAR TRANSITIONS
AIR FLOW
15° MAX
TRANSITION LENGTH
TO BE 18" MIN
R = W
W
R
R
AIR FLOW
TRANSITION LENGTH
TO BE 18" MIN
15° MAX
DOUBLE THICKNESS
TURNING VANES
SCALE: NONE
4
M0.1
LOW VELOCITY TRANSITIONS AND OFFSETS
NOTE
LOCATE VENT TERMINATION A
MIN. OF 18" ABOVE ROOF AND A
MIN. OF 10' FROM ANY VERTICAL
SURFACES OR OUTSIDE AIR
INTAKES
DETAIL NOTES
1. SEAL ALL JOINTS. SCREWS MAY NOT PENETRATE DUCTWORK.
CLAMP/SECURE TO DECK
PENETRATION THROUGH ROOF SHALL
BE NO LARGER THAN ID OF CONE
STORM COLLAR
SET IN SEALANT
TERMINATE OPENING MIN
18" MIN. ABOVE ROOF
ROOF
VENT SHALL BE GALVANIZED
STEEL OR ALUMINUM. SEE
PLANS FOR SIZE
SCALE: NONE
5
M0.1
DRYER VENT THRU ROOF DETAIL
MAX. 12" TO
BRANCH
CONNECTION
DETAIL NOTES
1. DO NOT LOCATE DAMPERS ABOVE DRYWALL/INACCESSIBLE CEILING LOCATIONS.
GALVANIZED ELBOW
GALVANIZED SHEET
METAL DUCT
SUPPLY AIR DIFFUSER
VOLUME DAMPER IF
INDICATED ON PLAN
1-1/2" THICK FIBERGLASS
INSULATION W/ FOIL FACING
SCALE: NONE
3
M0.1
DUCTWORK DIFFUSER MOUNTING DETAIL
SLOPE TO PREVENT
STANDING WATER
MAINTAIN DUCT SIZE
TO FULL SIZE OPENING
1
BACKDRAFT DAMPER
MECHANICAL LEGEND
AND DETAILS
DKK NDG
ISSUE DATE
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
COPYRIGHT 2020,CURRAN ARCHITECTURE
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
T E S
E N G I N E E R I N G
Cleveland, OH 44145
25760 First Street
P 440 871 2410
F 440 871 7954
tesengineering.com
DRAWN BY: ________ CHECKED BY: ________
PROJECT NUMBER: 200079
TIDE CLEANERS
2801 E. 116TH STREET
CARMEL, INDIANA 46033
DROP STORE
OWNER CHANGE 09/11/2020
M0.1
06/04/2020
09/24/20