HomeMy WebLinkAboutP0.I PLUMBING LEGEND & DETAILSABBREVIATIONS
TMV THERMOSTATIC MIXING VALVE
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORIES, INC.
MAKE-UP AIR
MECHANICAL
MANHOLE
MANUFACTURER
MINIMUM
MOUNTEDMTD
MUA
MECH
MFR
MIN
MH
1000 BTU PER HOUR
MAXIMUM
LOW PRESSURE
POUNDS
MAX
MBH
LBS, #
LP
HEIGHTH
KITCHEN EQUIPMENT CONTRACTORKEC
HEAD, HUB DRAIN
HORSEPOWER
HEATING, VENTILATING & A/C
HYDRANT
DOMESTIC HOT WATER
HERTZ
HVAC
HYD
HW
HZ
HD
HP
ELECTRICAL CONTRACTOR
GALLON
GALVANIZED
GENERAL CONTRACTOR
GREASE INTERCEPTOR
GALLONS PER MINUTE
GALLONS PER HOUR
GALLONS PER DAY
GAUGE
GREASE WASTE
GI
GPD
GPM
GPH
GW
GAL
GALV
GC
GA
DEGREES FAHRENHEIT
FOOT, FEET
EXISTING
FLOOR DRAIN
FLEXIBLE
FEET PER MINUTE
FLOOR SINK
FLOOR CLEANOUT
EXHAUST
°F
FT
FLEX
FPM
FCO
FD
FS
EX
EXH
EC
W/
W/O
WC
VTR
WITH
WATER COLUMN
WITHOUT
VENT THROUGH ROOF
VAC
UON
U/F
U/G
U/S
UL
TYP
VACUUM
VENT
UNDERGROUND
UNDERSLAB
UNDERFLOOR
TYPICAL
SQUARE FEET, SQUARE FOOT
REVOLUTIONS PER MINUTE
TOTAL STATIC PRESSURE
STORM WATER
POST INDICATOR VALVE
POUNDS PER SQUARE INCH
PRESSURE RELIEF VALVE
REFLECTED CEILING PLAN
REINFORCING, REINFORCED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MFR'S ASSOC.
NATIONAL FIRE PROTECTION ASSOC.
OUTSIDE STEM AND YOKE
OCCUPATIONAL SAFETY & HEALTH ADMIN.
AMERICAN WATER WORKS ASSOC.AWWA
EXTERNAL STATIC PRESSURE
ELECTRICAL
ELEVATION
EQUIPMENT
ENCLOSURE
DRAWING
EACH
ESP
ENCL
ELEC
EQUIP
ELEV
EA
DWG
DOMESTIC COLD WATER
DOWNSPOUT
DIAMETER
DEGREES
DIMENSION
DOWN
DS
DIA (OR Ø)
DN
DIM
CW
DEG
SPEC SPECIFICATION
THRU
TP
TSP
TDH
STD
SUSP
SURF
ST
SQ
TOTAL DYNAMIC HEAD
THROUGH
TOTAL PRESSURE
SUSPEND
STANDARD
SURFACE
SQUARE
SECT
SHT
SF
RPM
SECTION
SHEET
CONCRETE
CENTERLINE
COLUMN
CLEANOUT
CEILING
CUBIC FEET PER MINUTE
CUBIC FEET PER HOUR
L
CLG
COL
CO
C
CC
CFM
CFH
ASSEMBLYASSY
RD
REQ
REV
REINF
RCP
ROOF DRAIN
REQUIRED
REVISION, REVISE
PRV
PSI
PH, Ø
PIV
PLBG
PD
PLUMBING
PRESSURE DROP
PHASE
AMERICAN NAT'L STANDARDS INSTITUTE
AMERICAN SOCIETY OF TESTING & MATLS
AMERICAN SOCIETY OF MECHANICAL ENGRS
ABOVE FINISHED GRADE
AUXILIARY
ARCHITECT, ARCHITECTURAL
AMERICAN WELDING SOCIETY
ADJUSTABLE
ABOVE FINISHED FLOOR
ABOVE FINISHED CEILING
ASME
ASTM
AUX
AWS
AFG
ARCH
ANSI
ADJ
AFF
AFC
ABOVEABV
OS&Y
OSHA
OD
OC
NFPA
NTS
N.O.
NIC
OVERFLOW DRAINAGE
ON CENTER
NOT TO SCALE
NORMALLY OPEN
NOT IN CONTRACT
NEC
NEMA
N/A NOT APPLICABLE
EXISTING TO REMAINETR
REX REMOVE EXISTING
CLEANOUT PLUGCOP
OVERFLOW ROOF DRAINORD
RWC RAIN WATER CONDUCTOR
BOTTOM OF PIPE
BUILDING
BRITISH THERMAL UNIT
BOTTOM OF STRUCTURE
BUILDING AUTOMATION SYSTEM
BLDG
BOP
BOS
BTU
BAS
BELOW FLOOR
BUILDING MANAGEMENT SYSTEMBMS
DOMESTICDOM
FIRE PROTECTIONFP
FILTERED WATERFW
GROUNDGRD
MECHANICAL CONTRACTORMC
OVERHEADO/H
OPENINGOPNG
REL RELOCATED
SAN SANITARY
DEPTHD
GASG
CONNECT, CONNECTIONCONN
STUB UP FOR FUTURE
DCV
PLUMBING SYMBOLS
GAS MANIFOLD LOCATION
DOMESTIC WATER RISER
PLUMBING FIXTURES
DOUBLE CHECK BACKFLOW PREVENTER
SPRINKLER HEAD (SEMI-RECESSED)
SPRINKLER HEAD (FULLY-RECESSED)
SPRINKLER HEAD (UPRIGHT)
TENANT CONNECTION
NORMALLY CLOSEDN.C.
PB PUSH BUTTON
DOMESTIC HOT WATER RETURNHWR
B/F
CONNECT TO EXISTINGCTE
FINISHED FLOORFF
RR REMOVE AND RELOCATE
INSIDE DIAMETERID
INVERT ELEVATION
INCH, INCHES
INCHES OF WATER COLUMN (GAS)IN w.c
IN
IE
V
OS&Y VALVE
BALL VALVE
ELBOW DOWN
ELBOW UP
UNION
TEE OUTLET UP
TEE OUTLET DOWN
DIRECTION OF FLOW
VALVE IN DROP
EXPANSION JOINT
GATE VALVE
CALIBRATED BALANCING VALVE
PIPE GUIDE
3-WAY SELF OPERATING VALVE
BUTTERFLY VALVE
PRESSURE REDUCING VALVE
CHECK VALVE
MOTOR OPERATED VALVE
2-WAY SELF OPERATING VALVE
M
HOSE BIB
SANITARY PIPING
SANITARY VENT PIPING
SAN
V
GREASE WASTEGW
EXISTING PIPING TO REMAIN
COMPRESSED AIR PIPING
NEW PIPING / EQUIPMENT
NATURAL GAS PIPINGG
FS
T&P RELIEF VALVE
PRESSURE SWITCH
CAP ON END LINE
FLOW SWITCH
PRESSURE GAUGE WITH GAUGE COCK
THERMOMETER
FLEXIBLE CONNECTION
PIPE FLANGE
THERMOMETER WELL
GAS VALVE
WALL CLEANOUT OR CLEAOUT PLUG
FLOOR CLEANOUT
WATER METERM
GAS REGULATORR
FLOOR SINK (FS)
FLOOR DRAIN WITH P-TRAP
DRAWING NOTE REFERENCE
NEW TO EXISTING
POINT OF CONNECTION -
1
PS
(ALL ABBREVIATIONS SHOWN ARE NOT
NECESSARILY USED ON DRAWINGS)
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
PIPING ABOVE FLOOR
PIPING BELOW FLOOR
CA
3/8" POLISHED CHROME
SUPPLY LINE FOR
TEMPERED WATER LINE
UNDER-THE-COUNTER
THERMOSTATIC
TEMPERING VALVE
(TMV-1)
3/8" SUPPLY LINE FOR
CW TO FACUET
3/8"
1/4 TURN POLISHED
CHROME DUAL 3/8"
OUTLET STOP
1/4 TURN POLISHED
CHROME 3/8" OUTLET
STOP
3/8"
SINK
HOT WATER
SUPPLY
(HW) TO
FIXTURES
COLD
WATER
SUPPLY
(CW)
THERMOMETER
T&P RELIEF VALVE, PIPE
TO MOP SINK
INTAKE OUTLET
LOCATION (TYPICAL)
CHECK VALVE
(TYPICAL)
EXPANSION TANK,
REFER TO SCHEDULE
EXHAUST OUTLET
LOCATION (TYPICAL)
DRAIN OUTLET
LOCATION (TYPICAL)
GAS COCK
(TYPICAL)
UNION
(TYPICAL)
HOUSE KEEPING PAD,
BY OTHERS (TYPICAL)
6" DIRT LEG
(TYPICAL)G140° HW
GAS SUPPLY
SCALE: NONE
2
P0.1
PIPING DOMESTIC WATER HEATER GAS
6" DIRT LEG
REDUCE AS REQUIRED TO
CONNECT TO UNIT
VERIFY GAS LINE PRESSURE
PROVIDE GAS PRESSURE
REGULATOR IF REQUIRED
GAS COCK
GAS SERVICE ON ROOF
REFER TO PLANS FOR
CONTINUATION AND SIZES
GAS FIRED
EQUIPMENT
ON ROOF
UNION
ROOF
SCALE: NONE
4
P0.1
RTU GAS CONNECTION DETAIL 15" MIN. GAS LINE HEIGHT2'-0" MAX. DISTANCE 1ST SUPPORT
3" MIN.
ABOVE
ROOF
GAS PIPE MIN. 1-1/4"
ANCHOR PIPE TO ANGLE
WITH STD. U-BOLT
EXISTING
INSULATION
PROVIDE PATE PIPE
CURB AT ROOF
PENETRATION
"NOT SHOWN"
GROUND JOINT UNION
GAS VALVE
4" DIRT LEGGAS LINE ON ROOF
GAS LINE ON SUPPORT
SEE DETAIL
ROOF
STEEL WASHER
CLEVIS HANGERS- PIPES 1-1/4" & SMALLER 8'-0" MAX,
O.C. PIPES 1-1/2" & LARGER 10'-0" MAX. O.C.
GAS LINE
DIRT LEG MIN. 6"
AT EACH CHANGE
OF ELEVATION
DOUBLE
NUTTED
3"x3"x1/4" ANGLE
PROVIDE CAULKING
SCALE: NONE
5
P0.1
GAS PIPE THROUGH ROOF DETAIL
2" 2"12"
ASJ/SSL
BUTT STRIP
(TYPICAL)
RIB (TYPICAL)
180° RIBBED 18GA.
SHIELD SIMILAR
TO ANVIL #168
FIBERGLASS
INSULATION
PER SPECS
PIPE
HEAVY DUTY CLEVIS
HANGER. MATERIAL TO
MATCH PIPE
SUPPORT NUT
LOCKING NUT
HANGER ROD
SCALE: NONE
?
?
UP TO 1-1/4" PIPE SUPPORT DETAIL
SCALE: NONE
1
P0.1
THERMOSTATIC MIXING VALVE DETAIL
PLUMBING LEGEND AND
DETAILS
MMD DLJ
ISSUE DATE
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
COPYRIGHT 2020, CURRAN ARCHITECTURE
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
T E S
E N G I N E E R I N G
Cleveland, OH 44145
25760 First Street
P 440 871 2410
F 440 871 7954
tesengineering.com
DRAWN BY: ________ CHECKED BY: ________
PROJECT NUMBER: 200079
TIDE CLEANERS
2801 E. 116TH STREET
CARMEL, INDIANA 46033
DROP STORE
P0.1
Lint Filter
Detail
Top View
Removable Lint Filter
(location - typical)
location - typical
Drain to sewer
(size varies)
standpipe
Drain washer
into the top
(pump drain)
- OR -
Side View
Optional Bottom Drain
End View
Use Rubber Flex Coupling
to Connect Drain
Rubber Flex Coupling
ENGINEERING DATA
Commercial Grade
Body Material: 1/4" Polypropylene
Lid Material: 3/8" Polypropylene
Lint Filter Material: 1/4" pvc
Lint Filter Holes: 3/8"
Chemical Resistant
Maximum Water Temperature: 190 Degrees
lid attached with stainless steel screws
Optional Second Filter Can Be Installed
Can Manufacture Any Size Needed
Drain washer
- OR -
(gravity drain)
into the top
gaskets
Drain washer
into the side
(gravity drain)
pvc adapters
Removable Lid
SCALE: NONE
6
P0.1
TRENCH DRAIN DETAIL
06/04/2020
09/24/20