Loading...
HomeMy WebLinkAboutP2.0 PLUMBING NATURAL GAS PLANGGGD C8'-8"+/-F25F26 F29 EQ-1B F19 F18 F16 F24 F32 EQ-37 EQ-37 EQ-4c EQ-4c FUTURE F35 F34 F15 F21 EQ-3 EQ-3 FUTURE F12 F7 F3 F1 F1 F3 F7 F14F12 F12 F20 GR3 GR3 GR3GR4 102 DRIVE THRU 101 POS MAIN 103 METAL PROGETTI 104 MANAGER AREA 105 BREAK ROOM 106 DELIVERY107 EXIST. RESTROOM SCALE: 1/4" = 1'-0" 1 P2.0 PLUMBING NATURAL GAS PLAN SHEET KEYNOTES 1 2" GAS UP FROM EXISTING METER, THRU EXTERIOR WALL INTO O/H SPACE. PLUMBING CONTRACTOR TO CONFIRM LOCATION AND PRESSURE OF EXISTING METER PRIOR TO STARTING WORK. 2 1-1/4" GAS DOWN TO WATER HEATER. REFER TO DETAIL ON SHEET P0.1 3 1-1/4" GAS DOWN TO EACH DRYER STACK, PROVIDE WITH DIRT LEG, UNION, AND GAS COCK, 4 1" GAS UP THRU ROOF WITH CURB TO RTU-1. REFER TO DETAILS ON SHEET P0.1. 5 CONTRACTOR TO PROVIDE ROUGH IN CONNECTIONS WITH SHUT OFF VALVE AND CAP FOR FUTURE CONNECTION. 1" GAS O/H (80 MBH)1-1/4" GAS O/H (190 MBH) 1-1/2" GAS O/H (380 MBH) 2" GAS O/H (460 MBH) 2" GAS O/H (659 MBH) 1-1/4" GAS O/H (199 MBH) 1 2 3 4 OUTLINE OF RTU-1 ON ROOF GENERAL SHEET NOTES 1. EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS. 2. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. 3. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR "SMOKE TIGHT". SEAL AROUND ALL PENETRATIONS THROUGH RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 4. ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE. 5. PIPING IS NOT PERMITTED IN DEMISING WALLS. 6. ALL EXPOSED, EXTERIOR PIPING SHALL BE PAINTED WITH RUST INHIBITIVE PRIMER, COLOR CODED FINISH, AND IDENTIFICATION LABELS. 7. VERIFY NATURAL GAS AVAILABILITY AND CAPACITY. COORDINATE PRESSURE, SERVICE CONNECTION, AND METER INSTALLATION WITH THE LANDLORD AND LOCAL UTILITY COMPANY. 5 1 1 1 1 1 1 1 PLUMBING NATURAL GAS PLAN MMD DLJ KEY PLAN ISSUE DATE THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. COPYRIGHT 2020,CURRAN ARCHITECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES NORTH F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 N T E S E N G I N E E R I N G Cleveland, OH 44145 25760 First Street P 440 871 2410 F 440 871 7954 tesengineering.com DRAWN BY: ________ CHECKED BY: ________ PROJECT NUMBER: 200079 TIDE CLEANERS 2801 E. 116TH STREET CARMEL, INDIANA 46033 DROP STORE OWNER CHANGE 09/11/2020 P2.0 06/04/2020 09/24/20