Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A4.1
GENERAL NOTES 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES. 2. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED OTHERWISE. 3. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR OMISSIONS THAT MAY OCCUR TO THE ARCHITECT. A5.1 2 A5.1 3 A5.1 4 A5.1 1 A A A.6 B.1 B.7 C B.2 C.8 C.9 D E E 1 1 2 2 3 3 4 4 4.4 4.4 5 5 A.1 D.9 A6.1 1 A6.1 2 4.3 6 6 1 TYP. 1 TYP. 2 TYP. 2 TYP. 3 TYP. 4 TYP. 4 TYP. 4 TYP. 4 TYP. 5 TYP. 5 TYP. 5 TYP. 6 TYP. 6 5'-0"23'-6"47'-9"5'-0" TYP. 7 1'-3" 21'-5 1/8"27'-2"31'-4"30'-0"2'-0" D.S.D.S.D.S.D.S. TYP. 4 8"(WEST FACADE) 1'-1 1/8" (TYPICAL) 11 7/8" FACE BRICK VENEER WITH MASONRY ACHORS @ 16" O.C. (VERT.) 5/8" GYPSUM SHEATHING PREFIN. METAL PARAPET COPING WEATHER BARRIER PREFIN. PEMB METAL PANEL SYSTEM (BY SUPPLIER) (SEE ELEVATIONS) 16 GA. 6" METAL STUD @ 16" O.C. WITH BATT INSULATION (R-19 MIN.) (COORD. WITH STRUCT. DWGS.) 5/8" GYPSUM SHEATHING 2X TREATED WOOD BLOCKING (EAST FACADE BUMP OUT) 8 1/2" STATE OF 900019 No.MICHAE L W .HALS T E ADIND I A N AREGISTER E DARCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2020 Halstead Architects All Rights ReservedSTATE RFI - 06/01/2020 - - - - DESIGN DEVELOPMENT SET - 01/16/2020 90% CONST. DOCUMENTS - 04/01/2020NEW CONSTRUCTION FORMILLER AUTO CARE985 N. RANGELINE ROADCARMEL, INDIANA 46032HAMILTON COUNTYCLAY TOWNSHIP100% CONST. DOCUMENTS - 05/15/2020 1 2 3 4 A4.1 1832 MAY 15, 2020 ROOF PLAN KEYNOTES 1 STANDARD PEMB METAL ROOFING SYSTEM OVER SUPPLIED STRUCTURE AND INSULATION (R30 MIN. THICKNESS) - TYP. 2 10"x10" CONTINUOUS PREFIN. ALUMINUM GUTTER WITH 6"x6" ALUMINUM DOWNSPOUTS - TYP. 3 6"x6" CONTINUOUS PREFIN. ALUMINUM GUTTER WITH 4"x4" ALUMINUM DOWNSPOUT - TYP. 4 PREFINISHED METAL PARAPET COPING (SEE DETAIL 2/A4.1 TYP. - COLOR TO MATCH ACCENT METAL PANEL) - TYP. 5 PREFINISHED PEMB FASCIA (COLOR TO MATCH ACCENT METAL PANEL) - TYP. 6 PREFABRICATED ALUMINUM CANOPY. 7 BUILDING SIGNAGE BY OWNER (SEE SHEET A5.1) SCALE: 1/8" = 1'-0"1 ROOF PLAN SCALE: 1" = 1'-0"2 PARAPET DETAIL