Loading...
HomeMy WebLinkAboutLS2.1F.E.C.F.E.C.F.E.C.WELDING / WORK BENCH 3' X 6' TOOL BOX TOOL BOX TOOL BOX TOOLBOXWORKBENCHTOOLBOXWORKBENCHTOOLBOXWORKBENCHTOOLBOXWORKBENCHTOOL BOX WELDING /WORK BENCH3' X 6'WELDING / BEATING TABLE 5' X 5'55g 55g 55g 275g 275g WELDER BATTERY BATTERY A/C REPAIR AIR COMPRESSOR BRAKE LATHE A/C REPAIR A/C REPAIR A/C REPAIR BATTERY BATTERY TOOL BOX WORK BENCH WELDING / WORK BENCH 3' X 6' TOOL BOX WORK BENCH TOOL BOX WORK BENCH TOOL BOX WORK BENCH TOOLBOXWORKBENCHTOOLBOXWORKBENCHTOOLBOXWORKBENCHTOOLBOXWORKBENCHSHELF (4' X 2') SHELF (4' X 2') SHELF (4' X 2') SHELF (4' X 2')SHELF(4' X 2')TOOL BOX WORK BENCHWELDING /WORK BENCH3' X 6'GENERAL LSP NOTES & CODE SUMMARY 1. INFORMATION IS PROVIDED FOR USE BY CODE REVIEW PERSONNEL AND COORDINATION WITH ALL CONTRACTORS. ALL CONSULTANTS AND CONTRACTORS ARE RESPONSIBLE FOR COMPLYING WITH APPLICABLE CODE PROVISIONS INCLUDING, BUT NOT LIMITED TO, THOSE LISTED BELOW. NOT ALL DETAILS / CONDITIONS MAY BE SHOWN. NOTIFY ARCHITECT OF ANY DISCREPANCIES AS SOON AS POSSIBLE. 2. THIS PROJECT CONSISTS OF THE NEW CONSTRUCTION OF A MOTOR VEHICLE REPAIR FACILITY. 3. FIRE EXTINGUISHER LOCATIONS ARE INDICATED ON THE LIFE SAFETY PLANS. CONFIRM FINAL INSTALLATION LOCATIONS WITH THE FIRE MARSHAL. 4. OCCUPANCY CLASSIFICATION:B (BUSINESS) / S-1 (VEHICLE REPAIR) A. MEZZANINE: THE MEZZANINE SHALL NOT CONTRIBUTE TO THE BUILDING AREA OR NUMBER OF STORIES BECAUSE IT IS LESS THAN 1/3 OF THE FLOOR AREA OF THE ROOM IT IS LOCATED IN (AUTO- REPAIR) PER InBC 505.2. 5. BUILDING TYPE CLASSIFICATION: II-B 6. HEIGHT AND AREA: ALLOWABLE BLDG. HEIGHT (S-1):2 STORIES (55 FEET) ALLOWABLE BLDG. HEIGHT (B):3 STORIES (55 FEET) --------------------------------------------------------------------------------------------------- PROPOSED BLDG. HEIGHT:1 STORY + MEZZ. (25'-4") TABULAR ALLOWABLE AREA (S-1):17,500 SF PER FLOOR TABULAR ALLOWABLE AREA (B):23,000 SF PER FLOOR OPEN PERIMETER INCREASE:75% (PER InBC 506) --------------------------------------------------------------------------------------------------- TOTAL ALLOWABLE AREA (S-1):30,625 SF PER FLOOR TOTAL ALLOWABLE AREA (B):40,250 SF PER FLOOR PROPOSED MAX. AREA PER FLOOR:9,150 SF MEZZANINE AREA:980 SF 7. OCCUPANCY SEPARATIONS: THE BUILDING CONSISTS OF MIXED OCCUPANCIES, B & S-1. NO OCCUPANCY SEPARATION IS REQUIRED PURSUANT TO TABLE 508.4. 8. FIRE-RESISTANCE RATED CONSTRUCTION: ALL CONSTRUCTION ELEMENTS ARE TO BE NON-COMBUSTIBLE UNLESS ALLOWED BY SPECIFIC EXCEPTIONS AND AS NOTED IN THE DRAWINGS. NO FIRE- RESISTANCE RATED CONSTRUCTION IS REQUIRED PURSUANT TO InBC CHAPTER 6. 9. SPRINKLERS: SPRINKLERS ARE NOT REQUIRED FOR EITHER OCCUPANCY PURSUANT TO InBC CHAPTER 9. THE FIRE AREA IS LESS THAN 12,000 SF. 10. FIRE ALARM SYSTEMS: A FIRE ALARM SYSTEM IS NOT REQUIRED BY InBC SECTION 907.2.9 FOR EITHER OCCUPANCY. 11. COMMON PATH OF EGRESS (CPE) TRAVEL: NO AREA BEING EVALUATED REQUIRES MORE THAN ONE EXIT. 12. EXIT ACCESS TRAVEL DISTANCE: PERMITTED TO BE 200' (B) AND 300' (S-2) PER InBC TABLE 1016.2. THE LONGEST CALCULATED TRAVEL DISTANCE IS 108' +/-. 13. CORRIDOR FIRE RESTANCE RATINGS: NO CORRIDORS ARE PRESENT. 14. GENERAL MEANS OF EGRESS: NUMBER AND WIDTH OF EXITS IS IN EXCESS OF THE MINIMUM REQUIRED BY InBC CHAPTER 10. 15. EMERGENCY / EGRESS LIGHTING: REFER TO THE ELECTRICAL PLANS FOR LOCATIONS AND CONFIGURATION OF EMERGENCY EGRESS LIGHTING AND EXIT SIGNAGE. 16. THE 2010 INDIANA ENERGY AND CONSERVATION CODE (InECC) APPLIES TO THIS PROJECT. COMCHECK DOCUMENTATION SHALL BE SUBMITTED AS A PART OF THE CONSTRUCTION DOCUMENTS. 17. SIGNAGE SHALL BE INSTALLED TO MEET MINIMUM CODE STANDARDS AS FOLLOWS: INSTALL GRAPHIC & RAISED CHARACTER AND BRAILLE SIGNS AT EACH EXIT DOOR AND AT NEW TOILET FACILITIES. INSTALL SIGNS ON THE LATCH SIDE OF SINGLE LEAF DOORS (48" AFF TO THE BRAILLE) AND AT EITHER SIDE OF DOUBLE LEAF DOORS. LIFE SAFETY LEGEND REQUIRED BUILDING EXIT BUSINESS (100 GROSS) MANUFACTURING (200 NET) UTILITY / MECH / STORAGE (300 GROSS) DESCRIPTIONSYMBOL LINE TYPE RECESSED FIRE EXTINGUISHER LOCATION E.T.PATH OF EGRESS TRAVEL D.D.DIAGONAL DISTANCE OF SPACE M.R.P.MOST REMOTE POINT ES RAISED CHARACTER AND BRAILLE EXIT SIGN EXIT COMMON PATH OF EGRESS TRAVEL (InBC 1014.3) ALLOWABLE / REQURED PROVIDED CODE SUMMARY CHART EXIT ACCESS TRAVEL DISTANCE (InBC 1016.2) FIRE-RESISTANT CORRIDORS (InBC 1018.1) CORRIDOR WIDTH (InBC 1018.2) EGRESS WIDTH PER OCC. STAIRS OTHER 100' MAX (<30 OCC.) 200' (B) 300' (S-2) N/A N/A N/A 108' +/- N/A N/A PLUMBING FIXTURE COUNT (B OCC.) WATER CLOSETS LAVS DRINKING FOUNTAINS SERVICE SINK 60 OCC 1 PER 25 (4 REQ.) 1 PER 40 (2 REQ.) 1 PER 100 (1 REQ.) 1 (MIN.) 6 WC PROV. 4 LAVS PROV. 1 DF 1 3" (36" MIN.) 10" (MIN.) 40" 36" NOTE: 1) ADDITIONAL NON-ACCESSIBLE TOILET FACILITIES FOR EMPLOYEE USE ONLY ARE PROPOSED -THE QUANTITY OF THESE FIXTURES IS IN EXCESS OF THE MINIMUM REQUIRED BY CODE, THEREFORE THESE FIXTURES ARE NOT REQUIRED TO COMPLY WITH ADA. 2) ANTICIPATED OCCUPANT LOAD FOR MINIMUM REQ'D FIXTURE COUNT IS 30 (20 EMPLOYEES MAX. + 10 CUSTOMERS). OCCUPANT LOAD SUMMARY TOTAL USEABLE BUILDING AREA: 10,130 SF / 60 OCC FIRST FLOOR AREA: 9,150 SF / 52 OCC BUSINESS (100 GROSS) ---------------------1,248 SF / 13 OCC STORAGE (300 GROSS) --------------------722 SF / 3 OCC MANUFACTURING (200 GROSS) ---------7,180 SF / 36 OCC COMMON AREA -----------------------------------SF / ---OCC MEZZANINE FLOOR AREA: 980 SF / 8 OCC BUSINESS (100 GROSS) ---------------------569 SF / 6 OCC STORAGE (300 GROSS) --------------------229 SF / 1 OCC MECH / UTIL (300 GROSS) -----------------182 SF / 1 OCC COMMON AREA -----------------------------------SF / ---OCC NOTE: "COMMON AREA" REFERS TO SPACE WITHIN THE FLOOR PLAN WHICH IS NOT CONSIDERED OCCUPIED SUCH AS EGRESS PATHWAY. MANAGER WORKSTATION 111 WAITING 100 TOILET 102 TOILET 103 STAFF TOILET 110 WORKROOM 104 SERVICE DESK 101 EQUIPMENT STORAGE 112 ALIGNMENT BAY 113 REPAIR BAY 114 REPAIR BAY 115 REPAIR BAY 116 REPAIR BAY 117 REPAIR BAY 118 REPAIR BAY 119 REPAIR BAY 120 REPAIR BAY 121 REPAIR BAY 122 REPAIR BAY 123 REPAIR BAY 124 STAIR S1-1 OFFICE 105 DRESSING ROOM 106 OFFICE 107 CLO. 108 EXITEXITEXITEXITEXIT EXIT INSTALL FIRE EXTINGUISHERS A MAXIMUM OF 75' APART OR AS OTHERWISE DIRECTED BY THE LOCAL FIRE MARHSAL (TYPICAL) DENOTES MAXIMUM EXIT ACCESS TRAVEL (EAT) DISTANCE (108') B OCCUPANCY (BUSINESS) S-1 OCCUPANCY (AUTO REPAIR) STAIR S2-1 OPEN TO BELOW ATTIC 200 PARTS STORAGE 201 MECHANICAL 204 BREAK ROOM 202 TOILET 203 EXIT STATE OF 900019 No.MICHAE L W .HALS T E ADIND I A N AREGISTER E DARCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2020 Halstead Architects All Rights ReservedSTATE RFI - 06/01/2020 - - - - DESIGN DEVELOPMENT SET - 01/16/2020 90% CONST. DOCUMENTS - 04/01/2020NEW CONSTRUCTION FORMILLER AUTO CARE985 N. RANGELINE ROADCARMEL, INDIANA 46032HAMILTON COUNTYCLAY TOWNSHIP100% CONST. DOCUMENTS - 05/15/2020 1 2 3 4 LS2.1 1832 MAY 15, 2020 LIFE SAFETY PLANS SCALE: 1/8" = 1'-0"1 LIFE SAFETY PLANFIRST FLOOR SCALE: 1/8" = 1'-0"2 LIFE SAFETY PLANMEZZANINE 1