03 3000 - CAST -IN -PLACE CONCRETE
A. SECTION INCLUDES
1. CONCRETE FORMWORK.
2. ELEVATED CONCRETE SLABS.
3. FLOORS AND SLABS ON GRADE.
4. CONCRETE FOUNDATION WALLS.
5. CONCRETE REINFORCEMENT.
6. JOINT DEVICES ASSOCIATED WITH CONCRETE WORK.
B. CONCRETE FOR STRUCTURAL USE: COORDINATE REQUIREMENTS OF CAST -IN -PLACE CONCRETE WITH
STRUCTURAL DRAWINGS AND USE MOST STRINGENT REQUIREMENTS WHERE CONFLICTS OCCUR.
C. REFERENCE STANDARDS: COMPLY WITH PROVISIONS OF FOLLOWING CODES, AND STANDARDS, EXCEPT
WHERE MORE STRINGENT REQUIREMENTS SPECIFIED:
1. ACI 301 - SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS; AMERICAN CONCRETE INSTITUTE
INTERNATIONAL; 2005.
2. ACI 318 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY; AMERICAN
CONCRETE INSTITUTE INTERNATIONAL; 2008.
3. INDIANA BUILDING CODE, 2014 EDITION.
D. PRODUCTS:
1. FORMWORK:
a. FORM MATERIALS: CHOOSE PRODUCTS WITH SUFFICIENT STRENGTH TO WITHSTAND HYDROSTATIC
HEAD WITHOUT DISTORTION IN EXCESS OF PERMITTED TOLERANCES.
b. FORM FACING FOR EXPOSED FINISH CONCRETE: CHOOSE MATERIALS THAT WILL PROVIDE SMOOTH,
STAIN -FREE FINAL APPEARANCE.
c. FORM TIES: CONE SNAP TYPE THAT WILL LEAVE NO METAL WITHIN 1-1/2 INCHES OF CONCRETE
SURFACE.
2. REINFORCEMENT:
a. REINFORCING STEEL: ASTM A 615/A 615M GRADE 60 (420).
b. TYPE: DEFORMED BILLET -STEEL BARS.
c. FINISH: UNFINISHED, UNLESS OTHERWISE INDICATED.
d. FINISH: GALVANIZED IN ACCORDANCE WITH ASTM A 767/A 767M, CLASS I, UNLESS OTHERWISE
INDICATED.
3. STEEL WELDED WIRE REINFORCEMENT: ASTM A 185/A 185M, PLAIN TYPE. MESH SIZE AND WIRE GAGE: AS
INDICATED ON DRAWINGS.
4. REINFORCEMENT ACCESSORIES:
a. TIE WIRE: ANNEALED, MINIMUM 16 GAGE.
b. CHAIRS, BOLSTERS, BAR SUPPORTS, SPACERS: SIZED AND SHAPED FOR ADEQUATE SUPPORT OF
REINFORCEMENT DURING CONCRETE PLACEMENT.
c. PROVIDE STAINLESS STEEL, GALVANIZED, PLASTIC, OR PLASTIC COATED STEEL COMPONENTS FOR
PLACEMENT WITHIN 1-1/2 INCHES (38 MM) OF WEATHERING SURFACES.
E. CONCRETE MATERIALS:
1. CEMENT: ASTM C 150, TYPE I - NORMAL PORTLAND TYPE.
2. FINE AND COARSE AGGREGATES: ASTM C 33.
3. LIGHTWEIGHT AGGREGATE: ASTM C 330.
4. FLY ASH: ASTM C 618, CLASS C OR F.
5. CALCINED POZZOLAN: ASTM C 618, CLASS N.
6. SILICA FUME: ASTM C 1240, PROPORTIONED IN ACCORDANCE WITH ACI 211.1.
7. COLOR ADDITIVES: PURE, CONCENTRATED MINERAL PIGMENTS SPECIFICALLY INTENDED FOR MIXING
INTO CONCRETE AND COMPLYING WITH ASTM C 979.
8. WATER: CLEAN AND NOT DETRIMENTAL TO CONCRETE.
9. FIBER REINFORCEMENT: SYNTHETIC FIBER SHOWN TO HAVE LONG-TERM RESISTANCE TO DETERIORATION
WHEN EXPOSED TO MOISTURE AND ALKALIS; 1/2 INCH LENGTH.
E. CHEMICAL ADMIXTURES:
1. DO NOT USE CHEMICALS THAT WILL RESULT IN SOLUBLE CHLORIDE IONS IN EXCESS OF 0.1 PERCENT BY
WEIGHT OF CEMENT.
2. AIR ENTRAINMENT ADMIXTURE: ASTM C 260.
3. HIGH RANGE WATER REDUCING AND RETARDING ADMIXTURE: ASTM C 494/C 494M TYPE G.
4. HIGH RANGE WATER REDUCING ADMIXTURE: ASTM C 494/C 494M TYPE F.
5. WATER REDUCING & ACCELERATING ADMIXTURE: ASTM C 494/C 494M TYPE E.
F. ACCESSORY MATERIALS:
1. UNDER -SLAB VAPOR BARRIER: MULTI -LAYER, FABRIC-, CORD-, GRID-, OR ALUMINUM -REINFORCED
POLYETHYLENE OR EQUIVALENT, COMPLYING WITH ASTM E 1745 CLASS A; STATED BY MANUFACTURER
AS SUITABLE FOR INSTALLATION IN CONTACT WITH SOIL OR GRANULAR FILL UNDER CONCRETE SLABS.
WATER VAPOR TRANSMISSION RATE OF 0.006 WVTR OR LOWER, ASTM E96. SINGLE PLY POLYETHYLENE IS
PROHIBITED.
a. ACCEPTABLE PRODUCTS: STEGO INDUSTRIES "STEGO WRAP", WR MEADOWS, ALUMISEAL
"ZERO -PERM" OR APPROVED EQUAL.
2. CHEMICAL HARDENER: FLUOSILICATE SOLUTION DESIGNED FOR DENSIFICATION OF CURED CONCRETE
SLABS.
3. NON -SHRINK GROUT: ASTM C 1107/C 1107M; PREMIXED COMPOUND CONSISTING OF NON-METALLIC
AGGREGATE, CEMENT, WATER REDUCING AND PLASTICIZING AGENTS.
a. MINIMUM COMPRESSIVE STRENGTH AT 48 HOURS: 2,400 PSI.
b. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: 7,000 PSI.
4. CURING MATERIALS:
a. LIQUID MEMBRANE -FORMING CURING COMPOUND: LIQUID -TYPE MEMBRANE -FORMING CLEAR OR
TRANSLUCENT CURING COMPOUND COMPLYING WITH ASTM C 309, TYPE 1, CLASS A. MOISTURE LOSS
NOT MORE THAN .55 .FT./GAL KG/SQ. M WHEN APPLIED AT 200 S Q
b. MOISTURE -RETAINING SHEET: ASTM C 171.
c. POLYETHYLENE FILM: ASTM D 2103,4 MIL (0.1 MM) THICK, CLEAR.
d. WHITE -BURLAP -POLYETHYLENE SHEET, WEIGHING NOT LESS THAN 10 OZ/PER LINEAR YD, 40 INCHES
WIDE (305 GRAMS PER SQ. METER)
G. BONDING AND JOINTING PRODUCTS:
1. LATEX BONDING AGENT: NON -DISPERSIBLE ACRYLIC LATEX, COMPLYING WITH ASTM C 1059 TYPE II.
2. EPDXY BONDING SYSTEM: COMPLYING WITH ASTM C 881/C 881M AND OF TYPE REQUIRED FOR SPECIFIC
APPLICATION.
3. WATERPROOFING ADMIXTURE SLURRY: SLURRY COAT OF PORTLAND CEMENT SAND AND CRYSTALLINE
WATERPROOFING ADDITIVE, MIXED WITH WATER IN PROPORTIONS RECOMMENDED BY MANUFACTURER
TO ACHIEVE WATERPROOFING AT COLD JOINTS IN CONCRETE.
4. JOINT FILLER: NON -EXTRUDING, RESILIENT ASPHALT IMPREGNATED FIBERBOARD OR FELT, COMPLYING
WITH ASTM D 1751, 1/4 INCH THICK AND 4 INCHES DEEP; TONGUE AND GROOVE PROFILE.
5. JOINT FILLER: COMPRESSIBLE ASPHALT MASTIC WITH FELT FACERS, COMPLYING WITH ASTM D 994, 1/4
INCH THICK AND 4 INCHES DEEP.
6. SLAB CONSTRUCTION JOINT DEVICES: COMBINATION KEYED JOINT FORM AND SCREED, GALVANIZED
STEEL, WITH MINIMUM 1 INCH DIAMETER HOLES FOR CONDUIT OR REBARS TO PASS THROUGH AT 6
INCHES ON CENTER; RIBBED STEEL STAKES FOR SETTING.
H. CONCRETE MIX DESIGN:
1. ADMIXTURES: ADD ACCEPTABLE ADMIXTURES AS RECOMMENDED IN ACI 211.1 AND AT RATES
RECOMMENDED BY MANUFACTURER.
2. FIBER REINFORCEMENT: ADD TO MIX AT RATE OF 1.5 POUNDS PER CUBIC YARD, OR AS RECOMMENDED
BY MANUFACTURER FOR SPECIFIC PROJECT CONDITIONS.
3. NORMAL WEIGHT CONCRETE:
a. COMPRESSIVE STRENGTH, WHEN TESTED IN ACCORDANCE WITH ASTM C 39/C 39M AT 28 DAYS: 3,000
PSI.
b. WATER -CEMENT RATIO: MAXIMUM 40 PERCENT BY WEIGHT.
c. TOTAL AIR CONTENT: 4% DETERMINED IN ACCORDANCE WITH ASTM C 173/C 173M.
d. MAXIMUM SLUMP: 3 INCHES.
4. STRUCTURAL LIGHTWEIGHT CONCRETE:
a. COMPRESSIVE STRENGTH, WHEN TESTED IN ACCORDANCE WITH ASTM C 39/C 39M AT 28 DAYS: 3,000
PSI.
b. WATER -CEMENT RATIO: MAXIMUM 40 PERCENT BY WEIGHT.
c. TOTAL AIR CONTENT: 3%, DETERMINED IN ACCORDANCE WITH ASTM C 173/C 173M.
d. MAXIMUM SLUMP: 3 INCHES.
e. MAXIMUM AGGREGATE SIZE: 5/8 INCH.
f. MAXIMUM DRY UNIT WEIGHT: 115 LB PER CUBIC FOOT.
I. PREPARATION:
1. FORMWORK: COMPLY WITH REQUIREMENTS OF ACI 301. DESIGN AND FABRICATE FORMS TO SUPPORT
ALL APPLIED LOADS UNTIL CONCRETE IS CURED, AND FOR EASY REMOVAL WITHOUT DAMAGE TO
CONCRETE.
2. COORDINATE PLACEMENT OF EMBEDDED ITEMS WITH ERECTION OF CONCRETE FORMWORK AND
PLACEMENT OF FORM ACCESSORIES.
3. WHERE NEW CONCRETE IS TO BE BONDED TO PREVIOUSLY PLACED CONCRETE, PREPARE EXISTING
SURFACE BY CLEANING WITH STEEL BRUSH AND APPLYING BONDING AGENT IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
4. USE EPDXY BONDING SYSTEM FOR BONDING TO DAMP SURFACES, FOR STRUCTURAL LOAD -BEARING
APPLICATIONS, AND WHERE CURING UNDER HUMID CONDITIONS IS REQUIRED.
5. USE LATEX BONDING AGENT ONLY FOR NON -LOAD -BEARING APPLICATIONS.
6. WHERE NEW CONCRETE WITH INTEGRAL WATERPROOFING IS TO BE BONDED TO PREVIOUSLY PLACED
CONCRETE, PREPARE SURFACES TO BE TREATED IN ACCORDANCE WITH WATERPROOFING
MANUFACTURER'S INSTRUCTIONS. SATURATE COLD JOINT SURFACE WITH CLEAN WATER, AND REMOVE
EXCESS WATER BEFORE APPLICATION OF COAT OF WATERPROOFING ADMIXTURE SLURRY. APPLY
SLURRY COAT UNIFORMLY WITH SEMI -STIFF BRISTLE BRUSH AT RATE RECOMMENDED BY
WATERPROOFING MANUFACTURER.
7. IN LOCATIONS WHERE NEW CONCRETE IS DOWELED TO EXISTING WORK, DRILL HOLES IN EXISTING
CONCRETE, INSERT STEEL DOWELS AND PACK SOLID WITH NON -SHRINK GROUT.
8. INSTALL VAPOR RETARDER UNDER INTERIOR SLABS ON GRADE. LAP ALL JOINTS A MINIMUM OF 6 INCHES
AND SEAL WATERTIGHT BY TAPING EDGES AND ENDS. COVER WITH SAND TO DEPTH SHOWN ON
DRAWINGS; REPAIR DAMAGED VAPOR RETARDER BEFORE COVERING.
03 3000 - CAST -IN -PLACE CONCRETE (CONT.1
J. INSTALLING REINFORCEMENT:
1. COMPLY WITH REQUIREMENTS OF ACI 301. CLEAN REINFORCEMENT OF LOOSE RUST AND MILL SCALE,
AND ACCURATELY POSITION, SUPPORT, AND SECURE IN PLACE TO ACHIEVE NOT LESS THAN MINIMUM
CONCRETE COVERAGE REQUIRED FOR PROTECTION.
2. INSTALL WELDED WIRE REINFORCEMENT IN MAXIMUM POSSIBLE LENGTHS, AND OFFSET END LAPS IN
BOTH DIRECTIONS. SPLICE LAPS WITH TIE WIRE.
K. CONCRETE MIXING:
1. READY -MIX CONCRETE: COMPLY WITH REQUIREMENTS OF ASTM C-94, AND AS HEREIN SPECIFIED.
2. DELETE REFERENCES FOR ALLOWING ADDITIONAL WATER TO BE ADDED TO BATCH FOR MATERIAL WITH
INSUFFICIENT SLUMP. ADDITION OF WATER TO THE BATCH WILL NOT BE PERMITTED.
3. DURING HOT WEATHER, OR UNDER CONDITIONS CONTRIBUTING TO RAPID SETTING OF CONCRETE, A
SHORTER MIXING TIME THAN SPECIFIED IN ASTM C-94 MAY BE REQUIRED.
4. WHEN AIR TEMPERATURE IS BETWEEN 850 F. (300 C.) AND 900 F. (320 C.) REDUCE MIXING AND DELIVERY
TIME FROM 1-1/2 HOURS TO 75 MINUTES, AND WHEN AIR TEMPERATURE IS ABOVE 900 F. (320 C.), REDUCE
MIXING AND DELIVERY TIME TO 60 MINUTES.
L. PLACING CONCRETE:
1. PLACE CONCRETE IN ACCORDANCE WITH ACI 318, SECTION 5.10.
2. PLACE CONCRETE FOR FLOOR SLABS IN ACCORDANCE WITH ACI 302.1 R AND InBC 1910.1.
3. ENSURE REINFORCEMENT, INSERTS, WATER -STOPS, EMBEDDED PARTS, AND FORMED CONSTRUCTION
JOINT DEVICES WILL NOT BE DISTURBED DURING CONCRETE PLACEMENT.
4. REPAIR UNDER -SLAB VAPOR BARRIER DAMAGED DURING PLACEMENT OF CONCRETE REINFORCING.
REPAIR WITH VAPOR BARRIER MATERIAL; LAP OVER DAMAGED AREAS MINIMUM 6 INCHES AND SEAL
WATERTIGHT.
5. SEPARATE SLABS ON GRADE FROM VERTICAL SURFACES WITH JOINT FILLER.
6. PLACE JOINT FILLER IN FLOOR SLAB PATTERN PLACEMENT SEQUENCE. SET TOP TO REQUIRED
ELEVATIONS. SECURE TO RESIST MOVEMENT BY WET CONCRETE.
7. EXTEND JOINT FILLER FROM BOTTOM OF SLAB TO WITHIN 1/2 INCH (13 MM) OF FINISHED SLAB SURFACE.
CONFORM TO SECTION 07 9005 FOR FINISH JOINT SEALER REQUIREMENTS.
8. INSTALL JOINT DEVICES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
9. INSTALL CONSTRUCTION JOINT DEVICES IN COORDINATION WITH FLOOR SLAB PATTERN PLACEMENT
SEQUENCE. SET TOP TO REQUIRED ELEVATIONS. SECURE TO RESIST MOVEMENT BY WET CONCRETE.
10. MAINTAIN RECORDS OF CONCRETE PLACEMENT. RECORD DATE, LOCATION, QUANTITY, AIR
TEMPERATURE, AND TEST SAMPLES TAKEN.
11. PLACE CONCRETE CONTINUOUSLY BETWEEN PREDETERMINED EXPANSION CONTROL AND
CONSTRUCTION JOINTS.
12. DO NOT INTERRUPT SUCCESSIVE PLACEMENT; DO NOT PERMIT COLD JOINTS TO OCCUR.
13. SAW CUT JOINTS WITHIN 24 HOURS AFTER PLACING. USE 3/16 INCH (5 MM) THICK BLADE, CUT INTO 1/4
DEPTH OF SLAB THICKNESS.
14. SCREED FLOORS LEVEL, MAINTAINING SURFACE FLATNESS OF MAXIMUM 1/4 INCH IN 10 FT.
M. CONCRETE FINISHING:
1. REPAIR SURFACE DEFECTS, INCLUDING TIE HOLES, IMMEDIATELY AFTER REMOVING FORMWORK.
2. EXPOSED FORM FINISH: RUB DOWN OR CHIP OFF AND SMOOTH FINS OR OTHER RAISED AREAS 1/4 INCH (6
MM) OR MORE IN HEIGHT.
N. FIELD QUALITY CONTROL:
1. AN INDEPENDENT TESTING AGENCY WILL PERFORM FIELD QUALITY CONTROL TESTS.
2. PROVIDE FREE ACCESS TO CONCRETE OPERATIONS AT PROJECT SITE AND COOPERATE WITH APPOINTED
FIRM.
3. COMPRESSIVE STRENGTH TESTS: ASTM C 39/C 39M. FOR EACH TEST, MOLD AND CURE THREE CONCRETE
TEST CYLINDERS. OBTAIN TEST SAMPLES FOR EVERY 100 CU YD OR LESS OF EACH CLASS OF CONCRETE
PLACED.
0. DEFECTIVE CONCRETE:
1. TEST RESULTS: THE TESTING AGENCY SHALL REPORT TEST RESULTS IN WRITING TO ARCHITECT AND
CONTRACTOR WITHIN 24 HOURS OF TEST.
2. DEFECTIVE CONCRETE: CONCRETE NOT CONFORMING TO REQUIRED LINES, DETAILS, DIMENSIONS,
TOLERANCES OR SPECIFIED REQUIREMENTS.
3. DO NOT PATCH, FILL, TOUCH-UP, REPAIR, OR REPLACE EXPOSED CONCRETE EXCEPT UPON EXPRESS
DIRECTION OF ARCHITECT FOR EACH INDIVIDUAL AREA.
04 2000: UNIT MASONRY
A. SECTION INCLUDES: CONCRETE BLOCK BRICK REINFORCEMENT AND ANCHORAGES FLASHINGS LINTELS
AND ACCESSORIES.
B. SUBMITTALS: PROVIDE SAMPLES AND PRODUCT DATA FOR MASONRY UNITS, FABRICATED WIRE
REINFORCEMENT, MORTAR, AND MASONRY ACCESSORIES.
C. MOCK-UP: CONSTRUCT A MASONRY WALL AS A MOCK-UP PANEL SIZED 8 FEET LONG BY 6 FEET HIGH. THE
MOCK-UP SHALL INCLUDE BRICK VENEER, SPECIAL BRICK PATTERNS, CUT LIMESTONE, CONCRETE
MASONRY UNITS FLASHING WEEP VENTS. JOINT TOOLING MORTAR COLORS ANCHORAGE
REINFORCEMENT SEALANTS AND BOND PATTERNS. A MAXIMUM OF THREE (3) PANELS WILL BE REQUIRED.
APPROVAL OF ACCEPTABLE SAMPLE PANELS MUST BE OBTAINED FROM THE ARCHITECT IN WRITING PRIOR
TO THE DELIVERY OF MASONRY UNITS TO THE JOBSITE FOR INSTALLATION. LOCATE THE SAMPLE PANEL
WHERE DIRECTED. THE MOCK-UP MAY REMAIN AS PART OF THE WORK.
D. DELIVERY, STORAGE, AND HANDLING: DELIVER, HANDLE, AND STORE MASONRY UNITS BY MEANS THAT
WILL PREVENT MECHANICAL DAMAGE AND CONTAMINATION BY OTHER MATERIALS. DO NOT REMOVE FROM
PROTECTIVE PACKAGING UNTIL READY FOR INSTALLATION.
E. PRODUCTS
1. CONCRETE MASONRY UNITS
a. SIZE: STANDARD UNITS WITH NOMINAL FACE DIMENSIONS OF 16 X 8 INCHES AND NOMINAL DEPTHS
AS INDICATED ON THE DRAWINGS FOR SPECIFIC LOCATIONS.
b. SPECIAL SHAPES: PROVIDE NON-STANDARD BLOCKS CONFIGURED FOR CORNERS.
c. LOADBEARING UNITS: ASTM C 90, NORMAL WEIGHT.
d. EXPOSED FACES: MANUFACTURER'S STANDARD COLOR AND TEXTURE WHERE INDICATED.
e. NON -LOAD BEARING UNITS: ASTM C 129.
2. BRICK UNITS
a. MANUFACTURER AS SELECTED BY ARCHITECT: BASIS OF DESIGN IS BELDEN BRICK COMPANY
MONARCH SIZE (3-5/8" THICK X 3-5/8" HIGH X 15-5/8" LONG), CANYON FULL RANGE VELOUR.
b. FACING BRICK: ASTM C 216, TYPE FBS, GRADE SW.
c. COLOR AND TEXTURE TO MATCH ARCHITECT'S SAMPLE.
d. NOMINAL SIZE: AS INDICATED ON DRAWINGS.
e. SPECIAL SHAPES: MOLDED UNITS AS REQUIRED BY CONDITIONS INDICATED, UNLESS STANDARD
UNITS CAN BE SAWN TO PRODUCE EQUIVALENT EFFECT.
f. BUILDING (COMMON) BRICK: ASTM C 62, GRADE SW; SOLID UNITS.
3. MORTAR AND GROUT MATERIALS
a. MASONRY CEMENT: ASTM C 91, TYPE N.
b. COLORED MORTAR: PREMIXED CEMENT AS REQUIRED TO MATCH ARCHITECT'S COLOR SAMPLE.
ACCEPTABLE MANUFACTURERS ARE MAPEI, LATICRETE OR APPROVED EQUAL.
c. PORTLAND CEMENT: ASTM C 150, TYPE I - NORMAL; COLOR AS REQUIRED TO PRODUCE APPROVED
COLOR SAMPLE.
d. PACKAGED DRY MORTAR: ASTM C 387/C 387M, TYPE N, USING GRAY COLOR CEMENT.
e. HYDRATED LIME: ASTM C 207, TYPE S.
f. QUICKLIME: ASTM C 5, NON -HYDRAULIC TYPE.
g. MORTAR AGGREGATE: ASTM C 144.
h. PIGMENTS FOR COLORED MORTAR: PURE, CONCENTRATED MINERAL PIGMENTS SPECIFICALLY
INTENDED FOR MIXING INTO MORTAR AND COMPLYING WITH ASTM C 979. IN COLOR AS SELECTED
BY ARCHITECT FROM MANUFACTURERS FULL RANGE.
i. WATER: CLEAN AND POTABLE.
j. ACCELERATING ADMIXTURE: NON -CHLORIDE TYPE FOR USE IN COLD WEATHER.
k. MOISTURE -RESISTANT ADMIXTURE: WATER REPELLENT COMPOUND DESIGNED TO REDUCE
CAPILLARITY.
4. MORTAR MIXES
a. READY MIXED MORTAR: ASTM C 1142, TYPE RM.
b. MORTAR FOR UNIT MASONRY: ASTM C 270, PROPERTY SPECIFICATION.
c. MASONRY BELOW GRADE AND IN CONTACT WITH EARTH: TYPE S.
d. INTERIOR AND EXTERIOR, LOAD BEARING MASONRY: TYPE N.
e. EXTERIOR, NON -LOAD BEARING MASONRY: TYPE N.
f. INTERIOR, NON -LOAD BEARING MASONRY: TYPE 0.
g. GLASS UNIT MASONRY: TYPES.
h. POINTING MORTAR: TYPE N WITH MAXIMUM 2 PERCENT AMMONIUM STEARATE OR CALCIUM
STEARATE PER CEMENT WEIGHT.
i. COLORED MORTAR: PROPORTION SELECTED PIGMENTS AND OTHER INGREDIENTS TO MATCH
ARCHITECT'S SAMPLE, WITHOUT EXCEEDING MANUFACTURER'S RECOMMENDED
PIGMENT -TO -CEMENT RATIO.
F. REINFORCEMENT AND ANCHORAGE
1. REINFORCING STEEL: ASTM A 615/A 615M GRADE 40 (280) DEFORMED BILLET BARS; GALVANIZED.
2. HORIZONTAL JOINT REINFORCEMENT: LADDER TYPE; ASTM A 82/A 82M STEEL WIRE; 9 GAUGE SIDE
RODS AND CROSS RODS; WIDTH AS REQUIRED TO PROVIDE NOT MORE THAN 1 INCH AND NOT LESS
THAN 1/2 INCH OF MORTAR COVERAGE ON EACH EXPOSURE.
3. INTERIOR WALLS: USE MIL GALVANIZED ASTM A 641/A 641M, CLASS 3.
4. EXTERIOR WALLS: USE HOT -DIPPED GALVANIZED ASTM A 153, CLASS B-2, 1.5 OUNCES OF ZINC PER
SQUARE FOOT.
5. INSTALL PRE -FABRICATED SECTIONS AT CORNERS AND INTERSECTIONS OF WALLS.
6. ACCEPTABLE MANUFACTURERS: DUR-O-WAL, HECKMANN BUILDING PRODUCTS, INC., HOHMANN &
BARNARD, INC, WIRE BOND OR APPROVED EQUAL.
7. WALL TIES: CORRUGATED FORMED SHEET METAL, 7/8 INCH WIDE BY 0.05 INCH THICK, HOT DIP
GALVANIZED TO ASTM A 153/A 153M, CLASS B, SIZED TO PROVIDE NOT MORE THAN 1 INCH AND NOT
LESS THAN 1 INCH OF MORTAR COVERAGE FROM MASONRY FACE.
04 2000: UNIT MASONRY (CONT.)
8. MASONRY VENEER ANCHORS AT COLD FORM FRAMING: 2-PIECE ANCHORS THAT PERMIT DIFFERENTIAL
MOVEMENT BETWEEN MASONRY VENEER AND STRUCTURAL BACKUP, HOT DIP GALVANIZED TO ASTM A
153/A 153M, CLASS B. HOHMAN & BARBARD: DW-10 BRICK VENEER ANCHOR, OR APPROVED EQUAL.
9. INSTALL ANCHORS AT 16" O.C. VERTICALLY AND HORIZONTALLY.
10. ANCHOR PLATES: DESIGNED FOR FASTENING TO STRUCTURAL BACKUP THROUGH SHEATHING BY TWO
FASTENERS: VERTICAL ADJUSTMENT: NOT LESS THAN 3-1/2 INCHES.
11. INSTALL SEALING TAPE BETWEEN THE ANCHOR AND SHEATHING AT INSULATED CAVITY WALL
LOCATIONS.
G. FLASHINGS
1. THRU-WALL FLASHING: COPPER/KRAFT PAPER FLASHINGS: 5 OZ/SQ FT SHEET COPPER BONDED TO
FIBER REINFORCED ASPHALT TREATED KRAFT PAPER.
a. ACCEPTABLE MANUFACTURERS: HOHMANN & BARNARD, INC: "C-KRAFT DUPLEX", YORK
MANUFACTURING, INC: COP-R-TEX DUPLEX OR APPROVED EQUAL.
2. EXPOSED -TO -VIEW FLASHING: COPPER: ASTM B 370,060 SOFT ANNEALED; 20 OZ/SQ FT (0.7 MM) THICK;
NATURAL FINISH.
3. LIMESTONE FLASHING: STAINLESS STEEL: ASTM A 666, TYPE 304, SOFT TEMPER; 26 GAGE (0.45 MM)
THICK; FINISH 2B TO 2D.
H. ACCESSORIES
1. PREFORMED CONTROL JOINTS: RUBBER MATERIAL. PROVIDE WITH CORNER AND TEE ACCESSORIES,
FUSED JOINTS. ACCEPTABLE MANUFACTURERS: DUR-O-WAL; DA PVC CONTROL JOINTS, HOHMANN &
BARNARD, INC; VS SERIES PVC CONTROL JOINT OR APPROVED EQUAL.
2. JOINT FILLER: CLOSED CELL POLYVINYL CHLORIDE; OVERSIZED 50 PERCENT TO JOINT WIDTH; SELF
EXPANDING INSTALL WITH MAXIMUM LENGTHS AVAILABLE. ACCEPTABLE MANUFACTURERS:
DUR-O-WAL, HOHMANN & BARNARD, INC OR APPROVED EQUAL.
3. MORTAR NET CAVITY DRAINAGE SYSTEM: INSTALL MORTAR NET MESH WALL DRAINAGE SYSTEM, SIZED
TO THICKNESS OF WALL CAVITY, AND DESIGNED TO PREVENT MORTAR DROPPINGS FROM CLOGGING
WEEPS AND CAVITY VENTS AND ALLOW PROPER CAVITY DRAINAGE. INSTALL CONTINUOUSLY AT THE
BASE OF CAVITY WALLS. ACCEPTABLE MANUFACTURERS: MORTAR NET USA, LTD, SANDELL
MANUFACTURING COMPANY, HOHMANN & BARNARD, INC OR APPROVED EQUAL.
4. WEEPS: PLASTIC MESH; UV -RESISTANT RECYCLED POLYESTER, 90% OPEN WEAVE, SIZED TO
COMPLETELY FILL MASONRY OPEN HEAD JOINT OF COLOR TO APPROXIMATE MORTAR COLOR.
ACCEPTABLE MANUFACTURERS: MORTAR NET USA, LTD; "WEEP VENT" OR APPROVED EQUAL.
5. CAVITY VENTS: POLYESTER MESH. ACCEPTABLE MANUFACTURERS: HOHMANN AND BARNARD
"MORTAR NET, SANDELL MANUFACTURING COMPANY "SANDELLS MORTAR WEB, MORTAR NET USA, LTD;
MORTAR NET OR APPROVED EQUAL.
6. CONCRETE MASONRY CORE INSULATION; RIGID EXPANDABLE POLYSTYRENE (EPS) CORE INSERTS.
ACCEPTABLE MANUFACTURERS: CBIS/KORFIL, INC; "KORFIL":
7. MASONRY CLEANER: PROSOCO WANA TROL".
I. PREPARATION:
1. DIRECT AND COORDINATE PLACEMENT OF METAL ANCHORS SUPPLIED FOR INSTALLATION UNDER
OTHER SECTIONS.
2. PROVIDE TEMPORARY BRACING DURING INSTALLATION OF MASONRY WORK. MAINTAIN IN PLACE UNTIL
BUILDING STRUCTURE PROVIDES PERMANENT BRACING.
3. DO NOT ERECT MASONRY WHEN THE TEMPERATURE IS BELOW 32°F OR BELOW 40T AND FALLING,
UNLESS WORK IS COMPLETELY ENCLOSED AND CONTINUOUSLY HEATED. DO NOT BUILD ON FROZEN
WORK.
4. PROTECT WORK FROM FREEZING FOR FORTY-EIGHT (48) HOURS. COVER THE TOP OF THE COMPLETED
WORK TO KEEP OUT INCLEMENT WEATHER. COVERS SHALL EXTEND DOWN 2'-0" ON EITHER SIDE OF
THE WALL AND SHALL BE SECURELY ANCHORED.
J. COURSING: ESTABLISH LINES, LEVELS, AND COURSING INDICATED. PROTECT FROM DISPLACEMENT.
MAINTAIN MASONRY COURSES TO UNIFORM DIMENSION. FORM VERTICAL AND HORIZONTAL JOINTS OF
UNIFORM THICKNESS.
1. CONCRETE MASONRY UNITS: RUNNING BOND, COURSING: ONE UNIT AND ONE MORTAR JOINT TO
EQUAL 8 INCHES WITH CONCAVE MORTAR JOINTS.
2. BRICK UNITS: RUNNING BOND, THREE UNITS AND THREE MORTAR JOINTS TO EQUAL 8 INCHES WITH
CONCAVE MORTAR JOINTS.
K. PLACING AND BONDING: CONCRETE MASONRY UNITS SHALL BE WETTED PRIOR TO LAYING. TOOL ALL
JOINTS WHEN THE MORTAR IS THUMBPRINT HARD. LAY SOLID MASONRY UNITS IN FULL BED OF MORTAR,
WITH FULL HEAD JOINTS UNIFORMLY JOINTED WITH OTHER WORK. BUTTER VERTICAL JOINTS PLACE UNITS
SO AS TO FILL JOINTS WITH MORTAR. ALL MASONRY WORK SHALL BE PLUMB, TRUE AND LEVEL WITH
EQUALLY SPACED JOINTS AND COURSES. REMOVE EXCESS MORTAR AND MORTAR SMEARS AS WORK
PROGRESSES.
1. MORTAR JOINTS: ALL JOINTS, BOTH HORIZONTAL AND VERTICAL, FOR BRICK VENEER AND CONCRETE
MASONRY UNITS SHALL BE 3/8" WIDE.
2. JOINT TOOLING:
a. BRICK VENEER: TOOLED CONCAVE
b. CMU: TOOLED CONCAVE
L. WEEPS/CAVITY VENTS: INSTALL WEEPS IN VENEER AND CAVITY WALLS AT 24 INCHES ON CENTER
HORIZONTALLY ABOVE THROUGH -WALL FLASHING, ABOVE SHELF ANGLES AND LINTELS, AND AT BOTTOM OF
WALLS. INSTALL CAVITY VENTS IN VENEER AND CAVITY WALLS AT 32 INCHES ON CENTER HORIZONTALLY
BELOW SHELF ANGLES AND LINTELS, AND NEAR TOP OF WALLS.
M. CAVITY MORTAR CONTROL: DO NOT PERMIT MORTAR TO DROP OR ACCUMULATE INTO CAVITY AIR SPACE
OR TO PLUG WEEP/CAVITY VENTS. FOR CAVITY WALLS, BUILD INNER WYTHE AHEAD OF OUTER WYTHE TO
ACCOMMODATE ACCESSORIES. INSTALL MORTAR NET CAVITY DRAINAGE SYSTEM CONTINUOUSLY IN THE
EXTERIOR MASONRY CAVITIES DURING CONSTRUCTION, COMPLYING WITH MANUFACTURER'S INSTALLATION
INSTRUCTIONS. VERIFY THAT AIRSPACE WIDTH IS NO MORE THAN 3/8 INCH (9 MM) GREATER THAN PANEL
THICKNESS. INSTALL HORIZONTALLY BETWEEN JOINT REINFORCEMENT. FIT TO PERIMETER CONSTRUCTION
AND PENETRATIONS WITHOUT VOIDS.
N. REINFORCEMENT AND ANCHORAGE - GENERAL: INSTALL HORIZONTAL JOINT REINFORCEMENT 16 INCHES
ON CENTER. PLACE CONTINUOUS JOINT REINFORCEMENT IN FIRST AND SECOND JOINT BELOW TOP OF
WALLS. LAP JOINT REINFORCEMENT ENDS MINIMUM 6 INCHES. FASTEN ANCHORS TO STRUCTURAL
FRAMING AND EMBED IN MASONRY JOINTS AS MASONRY IS LAID. SPACE ANCHORS AT MAXIMUM OF 36
INCHES HORIZONTALLY AND 24 INCHES VERTICALLY.
0. REINFORCEMENT AND ANCHORAGE (MASONRY VENEER): INSTALL HORIZONTAL JOINT REINFORCEMENT 16
INCHES ON CENTER. PLACE MASONRY JOINT REINFORCEMENT IN FIRST AND SECOND HORIZONTAL JOINTS
ABOVE AND BELOW OPENINGS. EXTEND MINIMUM 16 INCHES EACH SIDE OF OPENING. LAP JOINT
REINFORCEMENT ENDS MINIMUM 6 INCHES
1. MASONRY BACK-UP: EMBED ANCHORS TO BOND VENEER AT MAXIMUM 16 INCHES ON CENTER
VERTICALLY AND 36 INCHES ON CENTER HORIZONTALLY. PLACE ADDITIONAL ANCHORS AT PERIMETER
OF OPENINGS AND ENDS OF PANELS, SO MAXIMUM SPACING OF ANCHORS IS 8 INCHES ON CENTER.
2. STUD BACK-UP: SECURE VENEER ANCHORS TO STUD FRAMED BACK-UP AND EMBED INTO MASONRY
VENEER AT MAXIMUM 16 INCHES ON CENTER VERTICALLY AND 24 INCHES ON CENTER HORIZONTALLY.
PLACE ADDITIONAL ANCHORS AT PERIMETER OF OPENINGS AND ENDS OF PANELS, SO MAXIMUM
SPACING OF ANCHORS IS 8 INCHES ON CENTER.
P. REINFORCEMENT AND ANCHORAGES (CAVITY WALL MASONRY): INSTALL HORIZONTAL JOINT
REINFORCEMENT 16 INCHES ON CENTER. PLACE MASONRY JOINT REINFORCEMENT IN FIRST AND SECOND
HORIZONTAL JOINTS ABOVE AND BELOW OPENINGS. EXTEND MINIMUM 16 INCHES EACH SIDE OF OPENINGS.
LAP JOINT REINFORCEMENT ENDS MINIMUM 6 INCHES. FASTEN ANCHORS TO STRUCTURAL FRAMING AND
EMBED IN MASONRY JOINTS AS MASONRY IS LAID. SPACE ANCHORS AT MAXIMUM OF 24 INCHES
HORIZONTALLY AND 16 INCHES VERTICALLY.
Q. MASONRY FLASHINGS: WHETHER OR NOT SPECIFICALLY INDICATED, INSTALL MASONRY FLASHING TO
DIVERT WATER TO EXTERIOR AT ALL LOCATIONS WHERE DOWNWARD FLOW OF WATER WILL BE
INTERRUPTED. SEAL LAPPED ENDS AND PENETRATIONS OF FLASHING BEFORE COVERING WITH MORTAR.
EXTEND METAL FLASHINGS THROUGH EXTERIOR FACE OF MASONRY AND TURN DOWN TO FORM DRIP.
INSTALL JOINT SEALER BELOW DRIP EDGE TO PREVENT MOISTURE MIGRATION UNDER FLASHING. EXTEND
PLASTIC AND LAMINATED FLASHINGS TO WITHIN 1/4 INCH OF EXTERIOR FACE OF MASONRY. LAP END
JOINTS OF FLASHINGS AT LEAST 4 INCHES AND SEAL WATERTIGHT WITH MASTIC OR ELASTIC SEALANT.
R. LINTELS: INSTALL PRECAST CONCRETE LINTELS OVER OPENINGS. MAINTAIN MINIMUM 8 INCH BEARING ON
EACH SIDE OF OPENING.
S. CONTROL AND EXPANSION JOINTS: DO NOT CONTINUE HORIZONTAL JOINT REINFORCEMENT THROUGH
CONTROL AND EXPANSION JOINTS. INSTALL PREFORMED CONTROL JOINT DEVICE IN CONTINUOUS
LENGTHS. SEAL BUTT AND CORNER JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
FORM EXPANSION JOINT AS DETAILED.
T. BUILT-IN WORK: AS WORK PROGRESSES, INSTALL BUILT-IN METAL DOOR FRAMES AND OTHER ITEMS TO BE
BUILT INTO THE WORK AND FURNISHED UNDER OTHER SECTIONS. INSTALL BUILT-IN ITEMS PLUMB, LEVEL,
AND TRUE TO LINE. BED ANCHORS OF METAL DOOR AND GLAZED FRAMES IN ADJACENT MORTAR JOINTS.
FILL FRAME VOIDS SOLID WITH GROUT. FILL ADJACENT MASONRY CORES WITH GROUT MINIMUM 12 INCHES
FROM FRAMED OPENINGS.
U. CUTTING AND FITTING: CUT AND FIT FOR CHASES. COORDINATE WITH OTHER SECTIONS OF WORK TO
PROVIDE CORRECT SIZE, SHAPE AND LOCATION. OBTAIN APPROVAL PRIOR TO CUTTING OR FITTING
MASONRY WORK NOT INDICATED OR WHERE APPEARANCE OR STRENGTH OF MASONRY WORK MAY BE
IMPAIRED.
V. CLEANING: REMOVE EXCESS MORTAR AND MORTAR DROPPINGS. CLEAN SOILED SURFACES WITH
CLEANING SOLUTION. USE NON-METALLIC TOOLS IN CLEANING OPERATIONS.
04 4200 - EXTERIOR STONE CLADDING
A. SECTION INCLUDES: CUT LIMESTONE, MARBLE, TRAVERTINE, GRANITE, SLATE, AND SANDSTONE
VENEER AT EXTERIOR AND INTERIOR WALLS. METAL ANCHORS AND SUPPORTS. JOINT SEALING AND
JOINT POINTING.
B. SUBMITTALS: SHOP DRAWINGS INDICATING LAYOUT, PERTINENT DIMENSIONS, ANCHORAGES, HEAD,
JAMB, AND SILL OPENING DETAILS, AND JOINTING METHODS. SUBMIT TWO SAMPLES 12" X 12" IN SIZE,
ILLUSTRATING COLOR RANGE AND TEXTURE, MARKINGS, AND SURFACE FINISH.
C. QUALITY ASSURANCE:
1. DESIGN ANCHORS AND SUPPORTS UNDER DIRECT SUPERVISION OF A PROFESSIONAL
STRUCTURAL ENGINEER, REGISTERED IN INDIANA.
2. PERFORM WORK IN ACCORDANCE WITH ILI INDIANA LIMESTONE HANDBOOK.
3. OBTAIN CUT, AND ROCK -FACED, LIMESTONE FROM A SINGLE QUARRY WITH CONSISTENT COLOR
RANGE AND TEXTURE THROUGHOUT WORK.
D. MOCK-UP: SEE DIVISION 04 2000 - UNIT MASONRY, PART 1 - SECTION C. APPROVAL OF ACCEPTABLE
SAMPLE PANELS MUST BE OBTAINED FROM THE ARCHITECT BEFORE DELIVERY OF LIMESTONE
MASONRY UNITS TO THE JOBSITE. THE SAMPLE PANELS MUST PROVIDE A COMPLETE EXTERIOR WALL
ASSEMBLY INCLUDING STONE VENEER, PATTERNS, CUT LIMESTONE, FLASHINGS, WEEP HOLES, JOINT
TOOLING, CAVITY WALLS, MORTAR COLORS, ANCHORAGE, REINFORCEMENT, SEALANTS AND BOND
PATTERNS. LOCATE WHERE DIRECTED, THE MOCK-UP MAY REMAIN AS PART OF THE WORK.
E. FIELD CONDITIONS: DURING STORAGE ON SITE, AT THE END OF WORKING DAY, AND DURING RAINY
WEATHER, COVER STONE WITH NON -STAINING WATERPROOF COVERINGS, SECURELY ANCHORED.
F. PRODUCTS
1. LIMESTONE: INDIANA OOLITIC LIMESTONE; COMPLYING WITH ASTM C568 CLASSIFICATION II -
MEDIUM DENSITY. GRADED ILI STANDARD, IN A BUFF COLOR. THE GRAIN DIRECTION IS TO BE
VERTICAL WITH A SMOOTH PLANAR FINISH.
a. PRODUCERS: INDIANA LIMESTONE COMPANY OR APPROVED EQUAL.
b. UTILIZE DENSE LIMESTONE AT BUILDING BASE FIRST COURSE ABOVE GRADE. THE TEXTURE
AND COLOR TO MATCH ADJACENT LIMESTONE AS CLOSE AS POSSIBLE.
2. MORTAR: ASTM C270, TYPE N, PROPORTION SPECIFICATION, USING PORTLAND CEMENT OF
WHITE COLOR. THE INTENT IS TO OBTAIN A WHITE MORTAR THAT IN TIME WILL APPROXIMATE
THE COLOR OF THE LIMESTONE. BOTH THE CEMENT AND THE SAND CAN HAVE A STRONG
EFFECT ON COLOR THUS IT SHALL BE AT THE ARCHITECT'S COMPLETE DISCRETION TO VARY
PROPORTIONS OF SAND AND PORTLAND CEMENT.
a. SETTING MORTAR: NON -STAINING TYPE, COMPOSED OF ONE (1) PART NON -STAINING TYPE I
PORTLAND CEMENT, ONE (1) PART LIME PUTTY AND SIX (6) PARTS WHITE SAND. ALL
QUANTITIES SHALL BE ACCURATELY MEASURED BY VOLUME.
b. POINTING MORTAR: ONE (1) PART NON -STAINING TYPE I PORTLAND CEMENT, TWO (2) PARTS
CLEAN WHITE SAND AND SUFFICIENT LIME OR LIME PUTTY TO MAKE AS STIFF A MIXTURE AS
CAN BE WORKED.
3. ANCHORS AND ACCESSORIES: ANCHORS AND OTHER COMPONENTS IN CONTACT WITH STONE
SHALL BE STAINLESS STEEL, ASTM A 666, TYPE 304 IN SIZES AND CONFIGURATIONS: AS
REQUIRED FOR VERTICAL AND HORIZONTAL SUPPORT OF STONE AND APPLICABLE LOADS. WIRE
TIES ARE NOT PERMITTED.
a. PIN ANCHORS: 6" LONG,'/z' DIAMETER, SCREW -TYPE WHERE NECESSARY.
b. STRAP ANCHORS, DOVETAIL ANCHORS, ETC. AS REQUIRED FOR A COMPLETE ASSEMBLY.
c. VENEER ANCHORS: HOHMAN & BARNARD, INC, 16" ON CENTER VERTICALLY AND
HORIZONTALLY.
d. SUPPORT COMPONENTS NOT IN CONTACT WITH STONE: STAINLESS STEEL, ASTM A167,
TYPE 304.
e. ANCHOR BOLTS, NUTS AND WASHERS: AISI TYPE 302/304 STAINLESS STEEL.
f. FLASHINGS: MINIMUM 16 OZ. PER SQUARE FOOT TYPE 302/304 STAINLESS STEEL.
g. WATERPROOFING: THORO SYSTEM PRODUCTS "THOROSEAL" OR EQUAL.
h. SEALANT: TYPE 1 IN COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURER'S
STANDARD SELECTIONS.
G. STONE FABRICATION: FABRICATE AS SHOWN AND DETAILED ON FINAL SHOP DRAWINGS AND IN
COMPLIANCE WITH RECOMMENDATIONS OF INDIANA LIMESTONE INSTITUTE. PROVIDE HOLES AND
SINKAGES CUT OR DRILLED FOR ANCHORS FASTENERS SUPPORTS AND LIFTING DEVICES AS SHOWN
AND AS NECESSARY TO SECURE STONEWORK IN PLACE. CUT AND BACK -CHECK AS REQUIRED FOR
PROPER FIT AND CLEARANCE. SHAPE BEDS TO FIT SUPPORTS.
1. CONTIGUOUS WORK: PROVIDE CHASES REVEALS REGLETS OPENINGS AND SIMILAR SPACES
AND FEATURES AS REQUIRED FOR CONTIGUOUS WORK. COORDINATE WITH DRAWINGS AND
FINAL SHOP DRAWINGS SHOWING CONTIGUOUS WORK.
2. CUT ACCURATELY TO SHAPE AND DIMENSIONS SHOWN ON FINAL SHOP DRAWINGS, MAINTAINING
FABRICATION TOLERANCES OF APPLICABLE STONE ASSOCIATIONS.
3. DRESS JOINTS BED AND VERTICAL STRAIGHT AND AT 90 DEGREE ANGLE TO FACE UNLESS
OTHERWISE INDICATED.
4. PROVIDE QUIRK -MITERED CORNERS, UNLESS OTHERWISE SHOWN.
5. PROVIDE FOR CRAMP ANCHORAGE IN TOP AND BOTTOM BED JOINTS OF CORNER UNITS, UNLESS
OTHERWISE SHOWN.
6. JOINT WIDTH: CUT TO PROVIDE JOINT WIDTHS AS INDICATED OR, IF NOT INDICATED, CUT TO
ALLOW FOR UNIFORM 3/8" WIDE JOINTS.
7. THICKNESS: AS INDICATED ON DRAWINGS.
8. PANEL SIZE: AS INDICATED ON DRAWINGS.
9. FABRICATE UNITS FOR UNIFORM COLORATION BETWEEN ADJACENT UNITS AND OVER THE FULL
AREA OF THE INSTALLATION.
10. WHERE CORNER DETAIL IS NOT INDICATED, FORM EXTERNAL CORNERS TO QUIRK JOINT PROFILE.
11. SLOPE EXPOSED TOP SURFACES OF STONE AND HORIZONTAL SILL SURFACES FOR NATURAL
WASH.
12. CUT DRIP SLOT IN BOTTOM SURFACE OF WORK PROJECTING MORE THAN 1/2 INCH OVER WALL
OPENINGS. SIZE SLOT NOT LESS THAN 3/8 INCH WIDE AND 1/4 INCH DEEP; FULL WIDTH OF
PROJECTION.
13. LETTERING: PROVIDE 1" DEEP "V" GROOVE LETTERING WITH BLACK LITHOCHROME FOR DATE
STONES AND CORNERSTONES.
H. PROJECT CONDITIONS: DO NOT USE FROZEN MATERIALS OR MATERIALS MIXED OR COATED WITH ICE
OR FROST. DO NOT USE SALT TO THAW ICE IN ANCHOR HOLES OR SLOTS. DO NOT USE ADMIXTURES
OR ANTI -FREEZE AGENTS, AND DO NOT USE CALCIUM CHLORIDE IN MORTAR OR GROUT. DO NOT
BUILD ON FROZEN WORK; REMOVE AND REPLACE STONEWORK DAMAGED BY FROST OR FREEZING.
REMOVE ICE OR SNOW FORMED ON BEDS BY CAREFULLY APPLYING HEAT UNTIL TOP SURFACE IS DRY
TO TOUCH.
I. PREPARATION:
1. EXAMINE SURFACES, AND CONDITIONS UNDER WHICH STONEWORK WILL BE INSTALLED FOR
COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES AND OTHER CONDITIONS
AFFECTING PERFORMANCE.
2. ADVISE OTHER CONTRACTORS ABOUT SPECIFIC REQUIREMENTS RELATING TO PLACEMENT OF
INSERTS, FLASHING REGLETS, AND SIMILAR ITEMS TO BE USED FOR ANCHORING, SUPPORTING,
AND FLASHING OF STONEWORK.
3. PROTECT STONEWORK DURING ERECTION AS FOLLOWS:
a. PREVENT STAINING OF STONE FROM MORTAR, GROUT, SEALANTS AND OTHER SOURCES.
IMMEDIATELY REMOVE SUCH MATERIALS FROM STONE WITHOUT DAMAGE TO LATTER.
b. PROTECT BASE OF WALLS FROM RAIN -SPLASHED MUD AND MORTAR SPLATTER BY MEANS
OF COVERINGS SPREAD ON GROUND AND OVER WALL SURFACE.
c. CLEAN STONE SURFACES THAT HAVE BECOME DIRTY OR STAINED PRIOR TO SETTING TO
REMOVE SOIL, STAINS, AND FOREIGN MATERIALS. CLEAN STONES BY THOROUGHLY
SCRUBBING STONES WITH FIBER BRUSHES FOLLOWED BY A THOROUGH DRENCHING WITH
CLEAR WATER. USE ONLY MILD CLEANING COMPOUNDS THAT CONTAIN NO CAUSTIC OR
HARSH FILLER OR ABRASIVES.
d. FERROUS METAL: WHERE STONEWORK WILL CONTACT FERROUS METAL SURFACES WHICH
WILL BE CONCEALED IN BACK-UP CONSTRUCTION (ANCHORS, SUPPORTS, STRUCTURAL
FRAMING AND SIMILAR SURFACES), APPLY A HEAVY COAT OF BITUMINOUS PAINT ON METAL
SURFACES, PRIOR TO SETTING OF STONE. DO NOT EXTEND COATING ONTO PORTIONS OF
FERROUS METAL WHICH WILL BE EXPOSED IN FINISHED WORK. DO NOT APPLY COATING TO
STAINLESS OR NOW FERROUS METALS.
J. SETTING STONE, GENERAL
1. EXECUTE STONEWORK BY SKILLED MECHANICS, AND STONE FITTERS FOR NECESSARY FIELD
CUTTING AS STONES ARE SET.
2. CUT STONE EDGES ARE TO BE STRAIGHT AND TRUE.
3. INSTALL ANCHORS, SUPPORTS, FASTENERS, AND OTHER ATTACHMENTS INDICATED OR
NECESSARY TO SECURE STONEWORK IN PLACE.
4. SHIM AND ADJUST ANCHORS, SUPPORTS, AND ACCESSORIES TO SET STONES ACCURATELY WITH
UNIFORM JOINTS OF WIDTHS AND WITH EDGES AND FACES ALIGNED.
5. INSTALL FLASHINGS OF LONGEST PRACTICAL LENGTH AND SEAL WATERTIGHT TO BACK-UP. LAP
END JOINT MINIMUM 6 INCHES AND SEAL WATERTIGHT.
6. UTILIZE DENSE LIMESTONE AT BUILDING BASE FIRST COURSE ABOVE GRADE. TEXTURE AND
COLOR ARE TO MATCH ADJACENT LIMESTONE AS CLOSE AS POSSIBLE.
7. WATERPROOFING: BACK PAINT BASE COURSING OF CUT STONE WITH APPROPRIATE
CEMENTITIOUS WATERPROOFING (THOROSEAL, TAMOSEAL, OR EQUAL), COLOR TO MATCH
ADJACENT STONE.FACES WITH CLEANING SOLUTION: PROSOCO, INC.; "VANATROL"
04 4200 - EXTERIOR STONE CLADDING (CONT.
8. INSTALL WEEP/CAVITY VENTS IN VERTICAL STONE JOINTS AT 48 INCHES ON CENTER
HORIZONTALLY, IMMEDIATELY ABOVE HORIZONTAL FLASHINGS, SHELF ANGLES AND SUPPORTS,
AND AT THE BOTTOM OF WALLS.
9. FILL JOINTS WITH POINTING MORTAR. PACK AND WORK INTO VOIDS. NEATLY TOOL SURFACES
TO CONCAVE JOINT.
10. SEAL JOINTS INDICATED WITH SEALANT.
K. SETTING STONEWORK WITH MORTAR
1. SET STONES IN FULL BED OF MORTAR WITH VERTICAL JOINTS SLUSHED FULL.
2. PLACE SETTING BUTTONS TO MAINTAIN UNIFORM JOINT WIDTHS. HOLD BUTTONS AT LEAST ONE
JOINT WIDTH BACK FROM FACE OF STONES.
3. DO NOT SET HEAVY STONES OR PROJECTING COURSES UNTIL MORTAR IN COURSES BELOW
HAVE HARDENED SUFFICIENTLY TO SUPPORT THE LOAD.
4. FILL ANCHOR HOLES WITH MORTAR.
5. SUPPORT PROJECTING STONES BY PROPS OR ANCHORS UNTIL WALL ABOVE IS SET.
6. EMBED ENDS OF LUGGED SILLS IN MORTAR; LEAVE BALANCE OF JOINT OPEN UNTIL FINAL
POINTING.
7. SET THE FOLLOWING STONEWORK WITH VERTICAL JOINTS RAKED W, FOR INSTALLATION OF
JOINT SEALANTS: CORNICES, COPINGS, SILLS, BELT AND OTHER PROJECTING COURSES. ALL
JOINTS SHALL BE'/<", TOOLED CONCAVE.
8. WHERE OPEN SPACE BETWEEN BACK OF STONE AND BACK-UP OR FRAMING IS SHOWN, KEEP
CAVITY OPEN; DO NOT FILL WITH MORTAR OR GROUT.
9. SHORE AND BRACE LIMESTONE LINTELS AND COLUMNS UNTIL MORTAR HAS CURED.
L. ADJUST AND CLEAN
1. REMOVE AND REPLACE STONE UNITS THAT ARE BROKEN, CHIPPED, STAINED OR OTHERWISE
DAMAGED.
2. WHERE DIRECTED, REMOVE AND REPLACE UNITS THAT DO NOT MATCH ADJOINING STONEWORK.
PROVIDE NEW MATCHING UNITS, INSTALL AS SPECIFIED AND POINT- UP JOINTS TO ELIMINATE
EVIDENCE OF REPLACEMENT.
3. RE -POINT DEFECTIVE AND UNSATISFACTORY JOINTS AS REQUIRED TO PROVIDE A NEAT,
UNIFORM APPEARANCE.
4. CLEAN STONEWORK NOT LESS THAN SIX DAYS AFTER COMPLETION OF WORK, USING CLEAN
WATER AND STIFF -BRISTLE BRUSHES. DO NOT USE WIRE BRUSHES OR OTHER CLEANING
COMPOUNDS WITH CAUSTIC OR HARSH FILLERS. USE PRE -WASH TO AVOID "ACID BURN" TO
LIMESTONE.
5. REMOVE EXCESS MORTAR AND SEALANT UPON COMPLETION OF WORK.
6. CLEAN SOILED SURFACES WITH CLEANING SOLUTION: PROSOCO, INC.; "VANATROL"
05 5000 - METAL FABRICATIONS
A. SECTION INCLUDES: SHOP FABRICATED STEEL AND ALUMINUM LADDERS, RAILINGS, BOLLARDS,
SHELF ANGLES, LINTELS AND STEEL FRAMES FOR OVERHEAD DOOR OPENINGS.
B. SUBMITTALS: SUBMIT SHOP DRAWINGS INDICATING PROFILES, SIZES, CONNECTION ATTACHMENTS,
REINFORCING, ANCHORAGE, SIZE AND TYPE OF FASTENERS, AND ACCESSORIES. INCLUDE ERECTION
DRAWINGS, ELEVATIONS, AND DETAILS WHERE APPLICABLE. THE DRAWINGS SHALL INDICATE
WELDED CONNECTIONS USING STANDARD AWS A2.4 WELDING SYMBOLS.
C. MATERIALS:
1. STEEL SECTIONS: ASTM A 36/A 36M.
2. STEEL TUBING: ASTM A 500, GRADE B COLD -FORMED STRUCTURAL TUBING.
3. PLATES: ASTM A 283.
4. PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH.
5. SHOP AND TOUCH-UP PRIMER: SSPC-PAINT 15, COMPLYING WITH VOC LIMITATIONS OF
AUTHORITIES HAVING JURISDICTION.
6. TOUCH-UP PRIMER FOR GALVANIZED SURFACES: SSPC-PAINT 20, TYPE I - INORGANIC,
COMPLYING WITH VOC LIMITATIONS OF AUTHORITIES HAVING JURISDICTION.
7. EXTRUDED ALUMINUM: ASTM B 221 (ASTM B 221 M), 6063 ALLOY, T6 TEMPER.
S. SHEET ALUMINUM: ASTM B 209 (ASTM B 209M), 5052 ALLOY, H32 OR H22 TEMPER.
9. ALUMINUM -ALLOY DRAWN SEAMLESS TUBES: ASTM B 210 (ASTM B 210M), 6063 ALLOY, T6
TEMPER.
D. FABRICATION: FIT AND SHOP ASSEMBLE ITEMS IN LARGEST PRACTICAL SECTIONS FOR DELIVERY TO
SITE. FABRICATE ITEMS WITH JOINTS TIGHTLY FITTED AND SECURED. GRIND EXPOSED JOINTS
FLUSH AND SMOOTH WITH ADJACENT FINISH SURFACE. MAKE EXPOSED JOINTS BUTT TIGHT, FLUSH,
AND HAIRLINE. EASE EXPOSED EDGES TO SMALL UNIFORM RADIUS. SUPPLY COMPONENTS
REQUIRED FOR ANCHORAGE OF FABRICATIONS. FABRICATE ANCHORS AND RELATED COMPONENTS
OF SAME MATERIAL AND FINISH AS FABRICATION.
E. FABRICATED ITEMS:
1. LEDGE ANGLES, SHELF ANGLES, CHANNELS, AND PLATES NOT ATTACHED TO STRUCTURAL
FRAMING: FOR SUPPORT OF METAL DECKING; PRIME PAINT FINISH.
2. LINTELS: AS DETAILED; PRIME PAINT FINISH.
3. DOOR FRAMES FOR OVERHEAD DOOR OPENINGS, WALL OPENINGS: CHANNEL SECTIONS;
PRIME PAINT FINISH.
F. BOLLARDS:
1. MATERIAL: STEEL PIPE, CONCRETE FILLED, WITH COVER AS NOTED BELOW, AS DETAILED;
SHOP PRIMER FINISH
2. BOLLARD COVERS: POST GUARD HDPE BOLLARD COVERS, SAFETY YELLOW WITH RED
REFLECTTIVE STRIPES
G. FINISHES:
1. PRIME PAINT ALL STEEL ITEMS EXCEPT GALVANIZED ITEMS TO BE EMBEDDED IN CONCRETE OR
MASONRY AND OTHER ITEMS SPECIFIED.
2. PREPARE SURFACES TO BE PRIMED IN ACCORDANCE WITH SSPC-SP2.
3. CLEAN SURFACES OF RUST, SCALE, GREASE, AND FOREIGN MATTER PRIOR TO FINISHING.
4. PRIME PAINTING OF STEEL: ONE COAT.
5. GALVANIZE NON-STRUCTURAL STEEL ITEMS AFTER FABRICATION IN ACCORDANCE WITH ASTM
A 123/A 123M REQUIREMENTS.
6. EXTERIOR ALUMINUM SURFACES: CLASS I NATURAL ANODIZED.
7. INTERIOR ALUMINUM SURFACES: CLASS I NATURAL ANODIZED.
8. CLASS I NATURAL ANODIZED FINISH: AAMA 611 AA-M12C22A41 CLEAR ANODIC COATING NOT
LESS THAN 0.7 MILS THICK.
H. PREPARATION: CLEAN AND STRIP PRIMED STEEL ITEMS TO BARE METAL WHERE SITE WELDING IS
REQUIRED. SUPPLY SETTING TEMPLATES TO THE APPROPRIATE ENTITIES FOR STEEL ITEMS
REQUIRED TO BE CAST INTO CONCRETE OR EMBEDDED IN MASONRY.
I. INSTALLATION: INSTALL ITEMS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM DISTORTION OR
DEFECTS.
CERTIFIED BY:
```````�11 1111/i //// i
,�. `G ... �� S ��i
� e`� �o%-• 10
No.
= 0 900019 0 =
STATE OF
iN \A
.DIA
lEli
.,1 R ``�
1
Lu
W
Q
N
<Q
co
0�
O
V
C)O
�
L
Z
O
O
W
Q
}
F---
C)J
iIIIIIII..
-
Z
Q
H q_
z=
L-) co
D
=)
Lu
_
c
OZ
- �:
O
�/1
�/
Q
v
7
%
`
0
J }
z
O
L
..
J
a
2 J
="
U
I..
W
3:
LLI
z
2E
W
Z
J
L�
�
J
_
CO
0)U
2
DRAWING
ARCHITECTURAL
SPECIFICATIONS
ISSUE
100% CONST. DOCUMENTS - 05/15/2020
90% CONST. DOCUMENTS - 04/01/2020
DESIGN DEVELOPMENT SET-01/16/2020
REVISIONS
1 -
2 -
3 -
4 -
PROJECT NUMBER 1832
DATE MAY 15, 2020