Loading...
HomeMy WebLinkAboutA0.2m L a) a) ry ry Q 4 U 2 L Q ca m w 0 N 0 N 05 5100 - METAL STAIRS A. SECTION INCLUDES: STEEL STAIRS WITH CONCRETE, METAL OR GRATING TREADS, STRUCTURAL STEEL STAIR FRAMING AND SUPPORTS AND HANDRAILS AND GUARDRAILS. B. SUBMITTALS: SUBMIT SHOP DRAWINGS INDICATING PROFILES, SIZES, CONNECTION ATTACHMENTS, REINFORCING, ANCHORAGE, SIZE AND TYPE OF FASTENERS, AND ACCESSORIES. INDICATE WELDED CONNECTIONS USING STANDARD AWS A2.4 WELDING SYMBOLS. C. METAL STAIRS: PROVIDE STAIRS OF THE DESIGN SPECIFIED, COMPLETE WITH LANDING PLATFORMS, VERTICAL AND HORIZONTAL SUPPORTS, RAILINGS, AND GUARDS, FABRICATED ACCURATELY FOR ANCHORAGE TO EACH OTHER AND TO BUILDING STRUCTURE WHILE COMPLYING WITH THE MOST STRINGENT REQUIREMENTS OF LOCAL, STATE, AND FEDERAL REGULATIONS. 1. SHOP ASSEMBLE ALL COMPONENTS; DISASSEMBLE INTO LARGEST PRACTICAL SECTIONS SUITABLE FOR TRANSPORT AND ACCESS TO SITE. 2. NO SHARP OR ROUGH AREAS ON EXPOSED TRAVEL SURFACES AND SURFACES ACCESSIBLE TO TOUCH. 3. SEPARATE DISSIMILAR METALS USING PAINT OR PERMANENT TAPE. 4. METAL JOINTING AND FINISH QUALITY LEVELS: a. ARCHITECTURAL: ALL JOINTS AS INCONSPICUOUS AS POSSIBLE, WHETHER WELDED OR MECHANICAL. b. WELDED JOINTS ARE TO BE CONTINUOUSLY WELDED AND GROUND SMOOTH AND FLUSH. c. MECHANICAL JOINTS SHALL BE BUTTED TIGHT, FLUSH, AND HAIRLINE; CONCEALED FASTENINGS ONLY. d. EXPOSED EDGES AND CORNERS SHALL BE EASED TO SMALL UNIFORM RADIUS. e. METAL SURFACES ARE TO BE PAINTED, SANDED OR GROUND SMOOTH, SUITABLE FOR HIGHEST QUALITY GLOSS, SATIN OR MATTE FINISH, AS DESIGNATED ON THE DRAWINGS. D. METAL STAIRS WITH DIAMOND PLATE TREADS: 1. RISERS ARE TO BE PARTIALLY OPEN, MEETING CODE REQUIRED CLEARANCES AND SPACING. 2. TREADS: FORMED DIAMOND PLATE METAL TREADS AND PARTIAL RISERS 3. TREAD AND RISER THICKNESS: AS REQUIRED BY DESIGN; 14 GAGE, MINIMUM. 4. PAN ANCHORAGE TO STRINGERS: CONTINUOUSLY WELDED, FROM TOP OR BOTTOM. 5. RISER/NOSING PROFILE SHALL BE A SLOPED RISER WITH ROUNDED NOSING OF MINIMUM RADIUS. 6. NOSING TO BE NO MORE THAN 1-1/2 INCH OVERHANG, WITH TOP FLUSH WITH TREAD FINISH 7. STRINGERS TO BE ROLLED STEEL CHANNELS OF SUITABLE SIZE AND THICKNESS FOR APPLICATION NOTED ON DRAWINGS. 8. END CLOSURE: SHEET STEEL OF SAME THICKNESS AS RISERS WELDED ACROSS ENDS. 9. LANDINGS ARE TO BE SAME CONSTRUCTION AS TREADS SUPPORTED AND REINFORCED AS REQUIRED TO ACHIEVE DESIGN LOAD CAPACITY. 10. STEEL PIPE RAILINGS AND GUARDRAILS FINISHED WITH SHOP OR FACTORY -PRIME PAINTED. E. HANDRAILS AND GUARDRAILS: SEE SECTION 05 5213 - PIPE & TUBE RAILINGS. F. MATERIALS: 1. STEEL SECTIONS: ASTM A 36/A 36M. 2. STEEL TUBING: ASTM A 500 OR ASTM A 501 STRUCTURAL TUBING, ROUND AND SHAPES AS INDICATED. 3. PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH. 4. UNGALVANIZED STEEL SHEET: HOT- OR COLD -ROLLED, EXCEPT USE COLD -ROLLED WHERE FINISHED WORK WILL BE EXPOSED TO VIEW. 5. HOT -ROLLED STEEL SHEET: ASTM A 1011/A 1 01 1 M, DESIGNATION CS (COMMERCIAL STEEL). 6. COLD -ROLLED STEEL SHEET: ASTM A 1008/A 1008M, DESIGNATION CS (COMMERCIAL STEEL). 7. STEEL BOLTS, NUTS, AND WASHERS: ASTM A 325 (ASTM A 325M), TYPE 1, GALVANIZED TO ASTM A 153/A 153M WHERE CONNECTING GALVANIZED COMPONENTS. 8. WELDING MATERIALS: AWS D1.1; TYPE REQUIRED FOR MATERIALS BEING WELDED. 9. SHOP AND TOUCH-UP PRIMER: SSPC-PAINT 15, COMPLYING WITH VOC LIMITATIONS OF AUTHORITIES HAVING JURISDICTION. 10. TOUCH-UP PRIMER FOR GALVANIZED SURFACES: SSPC-PAINT 20, TYPE I - INORGANIC, COMPLYING WITH VOC LIMITATIONS OF AUTHORITIES HAVING JURISDICTION. G. SHOP FINISHING: CLEAN SURFACES OF RUST SCALE GREASE AND FOREIGN MATTER PRIOR TO FINISHING. DO NOT PRIME SURFACES IN DIRECT CONTACT WITH CONCRETE OR WHERE FIELD WELDING IS REQUIRED. PRIME PAINTING SHALL BE ONE COAT OF SPECIFIED SHOP AND TOUCH-UP PRIMER. 1. PREPARATION OF STEEL: IN ACCORDANCE WITH SSPC-SP 2, HAND TOOL CLEANING. 2. GALVANIZING: HOT -DIP GALVANIZE TO MINIMUM REQUIREMENTS OF ASTM A 123/A 123M. TOUCH UP ABRADED AREAS AFTER FABRICATION USING SPECIFIED TOUCH-UP PRIMER FOR GALVANIZED SURFACES. H. PREPARATION: WHEN FIELD WELDING IS REQUIRED, CLEAN AND STRIP PRIMED STEEL ITEMS TO BARE METAL. SUPPLY ITEMS REQUIRED TO BE CAST INTO CONCRETE AND EMBEDDED IN MASONRY WITH SETTING TEMPLATES. I. INSTALLATION: 1. INSTALL COMPONENTS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM DISTORTION OR DEFECTS. 2. PROVIDE ANCHORS, PLATES, ANGLES, HANGERS, AND STRUTS REQUIRED FOR CONNECTING STAIRS TO STRUCTURE. 3. ALLOW FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY BRACING TO MAINTAIN TRUE ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT ATTACHMENTS. 4. PROVIDE WELDED FIELD JOINTS WHERE SPECIFICALLY INDICATED ON DRAWINGS. PERFORM FIELD WELDING IN ACCORDANCE WITH AWS D1.1. 5. OTHER FIELD JOINTS MAY BE EITHER WELDED OR BOLTED PROVIDED THE RESULT COMPLIES WITH THE LIMITATIONS SPECIFIED FOR JOINTING QUALITY LEVELS. 6. OBTAIN APPROVAL PRIOR TO SITE CUTTING OR CREATING ADJUSTMENTS NOT SCHEDULED. 7. AFTER ERECTION, PRIME WELDS, ABRASIONS, AND SURFACES NOT SHOP PRIMED OR GALVANIZED, EXCEPT SURFACES TO BE IN CONTACT WITH CONCRETE. J. TOLERANCES: MAXIMUM VARIATION FROM PLUMB SHALL BE 1/4 INCH PER STORY, NON -CUMULATIVE WITH A MAXIMUM OFFSET FROM TRUE ALIGNMENT OF 1/4 INCH. 05 5213 - PIPE AND TUBE RAILINGS A. SECTION INCLUDES: WALL MOUNTED HANDRAILS, STAIR RAILINGS, GUARDRAILS, FREE-STANDING RAILINGS AT STEPS AND BALCONY RAILINGS AND GUARDRAILS. B. SUBMITTALS: SUBMIT SHOP DRAWINGS INDICATING PROFILES, SIZES, CONNECTION ATTACHMENTS, ANCHORAGE, SIZE AND TYPE OF FASTENERS, AND ACCESSORIES. C. RAILINGS - GENERAL: 1. RAILING ASSEMBLIES SHALL BE IN ACCORDANCE WITH THE MOST STRINGENT REQUIREMENTS AND APPLICABLE CODES. 2. ALL RAILING ASSEMBLIES, WALL RAILS, AND ATTACHMENTS SHALL RESIST A LATERAL FORCE OF 75 LBS AT ANY POINT WITHOUT DAMAGE OR PERMANENT SET. 3. SEE DRAWINGS FOR CONFIGURATIONS AND HEIGHTS. 4. PROVIDE ANCHORS AND OTHER COMPONENTS AS REQUIRED TO SECURELY ATTACH TO SUBSTRATE, MADE OF SAME MATERIALS AS RAILING COMPONENTS; WHERE EXPOSED FASTENERS ARE UNAVOIDABLE PROVIDE FLUSH COUNTERSUNK FASTENERS. 5. ALUMINUM PIPE: SCHEDULE 40; ASTM B 429/13 429M, ASTM B 241/13 241 M, OR ASTM B 483/B 483M. 6. ALUMINUM TUBE: MINIMUM WALL THICKNESS OF 0.127 INCH; ASTM B 429/13 429M, ASTM B 241/13 241 M, OR ASTM B 483/13 483M. 7. WELDING FITTINGS: NO EXPOSED FASTENERS; CAST ALUMINUM. 8. EXPOSED FASTENERS: NO EXPOSED BOLTS OR SCREWS. D. HANDRAILS AND GUARDRAILS: 1. TOP RAILS SHALL BE ROUND PIPE OR TUBE RAILS UNLESS OTHERWISE INDICATED. 2. OUTSIDE DIAMETER: 1-1/4 INCH, MINIMUM, TO 1-1/2 INCHES, MAXIMUM. 3. UNLESS NOTED OTHERWISE, PROVIDE PICKET RAILINGS WITH VERTICAL 3/4" STEEL SQUARE BARS WITH A MAXIMUM SPACING OF 4" ON CENTER WELDED TO UNDERSIDE OF TOP RAIL AND THE TOP SURFACE OF STRINGER. 4. JOINTING: WELDED AND GROUND SMOOTH AND FLUSH. 5. END AND INTERMEDIATE POSTS SHALL BE THE SAME MATERIAL AND SIZE AS TOP RAILS WELDED TO THE TOP SURFACE OF STRINGER. E. STEEL RAILING SYSTEM: 1. STEEL TUBE: ASTM A 500, GRADE B COLD -FORMED STRUCTURAL TUBING. 2. STEEL PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH. 3. EXPOSED FASTENERS: NO EXPOSED BOLTS OR SCREWS. 4. SHOP AND TOUCH-UP PRIMER: SSPC-PAINT 15, COMPLYING WITH VOC LIMITATIONS OF AUTHORITIES HAVING JURISDICTION. 5. CHROME PLATING: ASTM B 177, NICKEL -CHROMIUM ALLOY, SATIN FINISH. 05 5213 - PIPE AND TUBE RAILINGS (CONT.) E. STEEL RAILING SYSTEM: 1. STEEL TUBE: ASTM A 500, GRADE B COLD -FORMED STRUCTURAL TUBING. 2. STEEL PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH. 3. EXPOSED FASTENERS: NO EXPOSED BOLTS OR SCREWS. 4. SHOP AND TOUCH-UP PRIMER: SSPC-PAINT 15, COMPLYING WITH VOC LIMITATIONS OF AUTHORITIES HAVING JURISDICTION. 5. CHROME PLATING: ASTM B 177, NICKEL -CHROMIUM ALLOY, SATIN FINISH. E. FABRICATION: 1. ACCURATELY FORM COMPONENTS TO SUIT SPECIFIC PROJECT CONDITIONS AND FOR PROPER CONNECTION TO BUILDING STRUCTURE. 2. FIT AND SHOP ASSEMBLE COMPONENTS IN LARGEST PRACTICAL SIZES FOR DELIVERY TO SITE. FABRICATE COMPONENTS WITH JOINTS TIGHTLY FITTED AND SECURED. 3. PROVIDE SPIGOTS AND SLEEVES TO ACCOMMODATE SITE ASSEMBLY AND INSTALLATION. 4. WELDED JOINTS: a. EXTERIOR COMPONENTS: CONTINUOUSLY SEAL JOINED PIECES BY INTERMITTENT WELDS AND PLASTIC FILLER. DRILL CONDENSATE DRAINAGE HOLES AT BOTTOM OF MEMBERS AT LOCATIONS THAT WILL NOT ENCOURAGE WATER INTRUSION. b. INTERIOR COMPONENTS: CONTINUOUSLY SEAL JOINED PIECES BY INTERMITTENT WELDS AND PLASTIC FILLER. C. GRIND EXPOSED JOINTS FLUSH AND SMOOTH WITH ADJACENT FINISH SURFACE. MAKE EXPOSED JOINTS BUTT TIGHT, FLUSH, AND HAIRLINE. EASE EXPOSED EDGES TO SMALL UNIFORM RADIUS. F. PREPARATION: CLEAN AND STRIP PRIMED STEEL ITEMS TO BARE METAL WHERE SITE WELDING IS REQUIRED. APPLY ONE COAT OF BITUMINOUS PAINT TO CONCEALED ALUMINUM SURFACES THAT WILL BE IN CONTACT WITH CEMENTITIOUS OR DISSIMILAR MATERIALS. G. INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INSTALL COMPONENTS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM DISTORTION OR DEFECTS, WITH TIGHT JOINTS. ANCHOR RAILINGS SECURELY TO STRUCTURE. CONCEAL ANCHOR BOLTS AND SCREWS WHENEVER POSSIBLE. WHERE NOT CONCEALED, USE FLUSH COUNTERSUNK FASTENINGS. 06 1000 - ROUGH CARPENTRY A. SECTION INCLUDES: NON-STRUCTURAL DIMENSION LUMBER AND FIRE RETARDANT TREATED WOOD MATERIALS FOR WOOD BLOCKING, NAILERS, AND SUPPORTS. B. DIMENSION LUMBER FOR CONCEALED APPLICATIONS: 1. SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. 2. MOISTURE CONTENT: S-DRY OR MC19. 3. MISCELLANEOUS FRAMING, BLOCKING, NAILERS, GROUNDS, AND FURRING: a. LUMBER: S4S, NO.2 OR STANDARD GRADE. b. BOARDS: STANDARD OR NO. 3. C. ACCESSORIES: 1. FASTENERS AND ANCHORS: a. METAL AND FINISH: HOT -DIPPED GALVANIZED STEEL PER ASTM A 153/A 153M FOR HIGH HUMIDITY AND PRESERVATIVE -TREATED WOOD LOCATIONS, UNFINISHED STEEL ELSEWHERE. b. DRYWALL SCREWS: BUGLE HEAD, HARDENED STEEL, POWER DRIVEN TYPE, LENGTH THREE TIMES THICKNESS OF SHEATHING. 2. GLUE: WATERPROOF, POLYURETHANE BASE, AIR CURE TYPE, CARTRIDGE DISPENSED. D. FACTORY WOOD TREATMENT: 1. TREATED LUMBER AND PLYWOOD: COMPLY WITH REQUIREMENTS OF AWPA U1 - USE CATEGORY SYSTEM FOR WOOD TREATMENTS DETERMINED BY USE CATEGORIES, EXPECTED SERVICE CONDITIONS, AND SPECIFIC APPLICATIONS. 2. FIRE -RETARDANT TREATED WOOD: MARK EACH PIECE OF WOOD WITH PRODUCER'S STAMP INDICATING COMPLIANCE WITH SPECIFIED REQUIREMENTS. 3. PRESERVATIVE -TREATED WOOD: PROVIDE LUMBER AND PLYWOOD MARKED OR STAMPED BY AN ALSC-ACCREDITED TESTING AGENCY, CERTIFYING LEVEL AND TYPE OF TREATMENT IN ACCORDANCE WITH AWPA STANDARDS. E. INSTALLATION - GENERAL: SELECT MATERIAL SIZES TO MINIMIZE WASTE. REUSE SCRAP TO THE GREATEST EXTENT POSSIBLE; CLEARLY SEPARATE SCRAP FOR USE ON SITE AS ACCESSORY COMPONENTS, INCLUDING: SHIMS, BRACING, AND BLOCKING. WHERE TREATED WOOD IS USED ON INTERIOR, PROVIDE TEMPORARY VENTILATION DURING AND IMMEDIATELY AFTER INSTALLATION SUFFICIENT TO REMOVE INDOOR AIR CONTAMINANTS. H. BLOCKING, NAILERS, AND SUPPORTS: PROVIDE FRAMING AND BLOCKING MEMBERS AS INDICATED OR AS REQUIRED TO SUPPORT FINISHES, FIXTURES, SPECIALTY ITEMS, AND TRIM. 1. IN METAL STUD WALLS, PROVIDE CONTINUOUS BLOCKING AROUND DOOR AND WINDOW OPENINGS FOR ANCHORAGE OF FRAMES SECURELY ATTACHED TO STUD FRAMING. 2. IN WALLS, PROVIDE BLOCKING ATTACHED TO STUDS AS BACKING AND SUPPORT FOR WALL -MOUNTED ITEMS, UNLESS ITEM CAN BE SECURELY FASTENED TO TWO OR MORE STUDS OR OTHER METHOD OF SUPPORT IS EXPLICITLY INDICATED. 3. WHERE CEILING -MOUNTING IS INDICATED, PROVIDE BLOCKING AND SUPPLEMENTARY SUPPORTS ABOVE CEILING UNLESS OTHER METHOD OF SUPPORT IS EXPLICITLY INDICATED. 4. SPECIFICALLY, PROVIDE THE FOLLOWING NON-STRUCTURAL FRAMING AND BLOCKING: CABINETS AND SHELF SUPPORTS, WALL BRACKETS, HANDRAILS, GRAB BARS, TOWEL AND BATH ACCESSORIES, WALL -MOUNTED DOOR STOPS, CHALKBOARDS AND MARKER BOARDS, AND WALL PANELING AND TRIM. I. TOLERANCES: FRAMING MEMBERS: 1/4 INCH FROM TRUE POSITION, MAXIMUM. VARIATION FROM PLANE (OTHER THAN FLOORS): 1/4 INCH IN 10 FEET MAXIMUM, AND 1/4 INCH IN 30 FEET MAXIMUM. J. CLEANING: WASTE DISPOSAL SHALL COMPLY WITH APPLICABLE REGULATIONS. DO NOT BURN ANY SCRAP ON THE PROJECT SITE. DO NOT SEND MATERIALS TREATED WITH PENTACHLOROPHENOL, CCA, OR ACA TO CO -GENERATION FACILITIES OR "WASTE -TO -ENERGY" FACILITIES. PREVENT SAWDUST AND WOOD SHAVINGS FROM ENTERING THE STORM DRAINAGE SYSTEM. 07 2100 - THERMAL INSULATION A. SECTION INCLUDES: BOARD INSULATION, PERIMETER FOUNDATION WALL, AND UNDERSIDE OF FLOOR SLABS. BATT INSULATION AND VAPOR RETARDER IN EXTERIOR WALL, CEILING, AND ROOF CONSTRUCTION. B. SUBMITTALS: PRODUCT DATA: PROVIDE DATA ON PRODUCT CHARACTERISTICS, PERFORMANCE CRITERIA, AND PRODUCT LIMITATIONS. C. PRODUCT APPLICATIONS: 1. UNDER CONCRETE SLABS AND AT PERIMETER OF FOUNDATIONS: EXTRUDED POLYSTYRENE BOARD. 2. INSIDE MASONRY CAVITY WALLS: EXPANDED POLYSTYRENE BOARD. 3. METAL AND WOOD FRAMED WALLS AND FRAMED CEILING STRUCTURES: BATT INSULATION WITH SEPARATE VAPOR RETARDER. 4. ABOVE LAY -IN ACOUSTICAL CEILINGS: BATT INSULATION WITH NO VAPOR RETARDER. 5. REFER TO DRAWINGS FOR LOCATIONS AND RELATED R-VALUES - COORDINATE WITH THE INDIANA ENERGY AND CONSERVATION CODE REQUIREMENTS FOR PROPOSED APPLICATION AND USE. D. BOARD INSULATION MATERIALS: 1. EXTRUDED POLYSTYRENE BOARD INSULATION: ASTM C 578, TYPE X; EXTRUDED POLYSTYRENE BOARD WITH THE FOLLOWING CHARACTERISTICS: a. FLAME SPREAD INDEX: 75 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. b. SMOKE DEVELOPED INDEX: 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. c. BOARD SIZE: 48 X 96 INCH X 1-1/2 INCHES THICK WITH SQUARE EDGES. d. THERMAL CONDUCTIVITY (K FACTOR) AT 25 DEGREES F: 0.18. e. COMPRESSIVE RESISTANCE: 15 PSI. f. BOARD DENSITY: 1.3 LB/CU FT. g. WATER ABSORPTION, MAXIMUM: 0.3 PERCENT, VOLUME. h. MANUFACTURERS: DOW CHEMICAL "STYROFOAM SE", OWENS-CORNING "FOAMULAR 250" OR APPROVED EQUAL. 2. POLYISOCYANURATE BOARD INSULATION: ASTM C 1289; RIGID CELLULAR FOAM, TYPE I, ALUMINUM FOIL BOTH FACES; CLASS 1, NON -REINFORCED FOAM CORE WITH THE FOLLOWING CHARACTERISTICS: a. FLAME SPREAD INDEX: 75 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. b. SMOKE DEVELOPED INDEX: 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. C. COMPRESSIVE STRENGTH: 16 PSI. d. BOARD SIZE: 48 X 96 INCH X 1 INCH THICK WITH SQUARE EDGES. e. MANUFACTURERS: JOHNS MANVILLE "ENRGY 3", POLYISOCYAN U RATE, GAF MATERIALS CORPORATION: "ENERGYGUARD", DOW CHEMICAL CO: "VORATHERM" OR APPROVED EQUAL. 3. EXPANDED POLYSTYRENE BOARD INSULATION: ASTM C578, TYPE X; EXPANDED POLYSTYRENE BOARD WITH THE FOLLOWING CHARACTERISTICS: a. FLAME SPREAD INDEX: 25 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. b. SMOKE DEVELOPED: 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. C. BOARD SIZE: 48 X 96 INCH X 1-1/2 INCHES THICK WITH SQUARE EDGES. d. THERMAL CONDUCTIVITY (K FACTOR) AT 25 DEGREES F: 0.84. e. COMPRESSIVE RESISTANCE: 15 PSI. f. BOARD DENSITY: 1.5 LB/CU FT. g. WATER ABSORPTION, MAXIMUM: 0.3 PERCENT, VOLUME. h. MANUFACTURERS: ACH FOAM TECHNOLOGIES "FOAM CONTROL PLUS+ 150", OR APPROVED EQUAL. E. BATT INSULATION MATERIALS: 1. BATT INSULATION (UNFACED): ASTM C 665; PREFORMED BATT; FRICTION FIT, WITH THE FOLLOWING CHARACTERISTICS: a. MATERIAL: GLASS OR MINERAL FIBER. b. FLAME SPREAD INDEX: 25 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. c. SMOKE DEVELOPED INDEX: 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. d. COMBUSTIBILITY: NON-COMBUSTIBLE WHEN TESTED IN ACCORDANCE WITH ASTM E 136. e. FORMALDEHYDE CONTENT: ZERO. f. THERMAL RESISTANCE AND THICKNESS TO BE AS INDICATED ON DRAWINGS. g. MANUFACTURERS: CERTAINTEED CORPORATION, JOHNS MANVILLE CORPORATION, OWENS CORNING CORP. OR APPROVED EQUAL. F. ACCESSORIES: 1. SHEET VAPOR RETARDER: BLACK POLYETHYLENE FILM FOR ABOVE GRADE APPLICATION, 10 MIL THICK. 2. TAPE: BRIGHT ALUMINUM SELF -ADHERING TYPE, MESH REINFORCED, 2 INCH WIDE. 3. INSULATION FASTENERS: IMPALING CLIP OF UNFINISHED STEEL WITH WASHER RETAINER AND CLIPS TO BE ADHERED TO SURFACE TO RECEIVE INSULATION LENGTH TO SUIT INSULATION THICKNESS AND SUBSTRATE, CAPABLE OF SECURELY AND RIGIDLY FASTENING INSULATION IN PLACE. 4. NAILS OR STAPLES: STEEL WIRE; ELECTROPLATED, OR GALVANIZED; TYPE AND SIZE TO SUIT APPLICATION. 5. PROTECTION BOARD FOR BELOW GRADE INSULATION: CEMENTITIOUS 1/4 INCH THICK. 6. ADHESIVE: TYPE RECOMMENDED BY INSULATION MANUFACTURER FOR APPLICATION. G. BOARD INSTALLATION AT FOUNDATION PERIMETER: 1. ADHERE A 6 INCH WIDE STRIP OF POLYETHYLENE SHEET OVER CONSTRUCTION, CONTROL, AND EXPANSION JOINTS WITH DOUBLE BEADS OF ADHESIVE EACH SIDE OF JOINT. 2. TAPE SEAL JOINTS. 3. EXTEND SHEET FULL HEIGHT OF JOINT. 4. INSTALL BOARDS HORIZONTALLY ON FOUNDATION PERIMETER. 5. PLACE BOARDS TO MAXIMIZE ADHESIVE CONTACT. 6. INSTALL IN RUNNING BOND PATTERN. 7. BUTT EDGES AND ENDS TIGHTLY TO ADJACENT BOARDS AND TO PROTRUSIONS. 8. EXTEND BOARDS OVER EXPANSION JOINTS, UN -BONDED TO FOUNDATION ON ONE SIDE OF JOINT. 9. CUT AND FIT INSULATION TIGHTLY TO PROTRUSIONS OR INTERRUPTIONS TO THE INSULATION PLANE. 10. IMMEDIATELY FOLLOWING APPLICATION OF BOARD INSULATION, PLACE PROTECTIVE BOARDS OVER EXPOSED INSULATION SURFACES. 11. INSTALL BOARDS HORIZONTALLY FROM BASE OF FOUNDATION TO TOP OF INSULATION. 12. BUTT BOARDS TIGHTLY, WITH JOINTS STAGGERED FROM INSULATION JOINTS. H. BOARD INSTALLATION AT EXTERIOR WALLS: 1. ADHERE A 6 INCH WIDE STRIP OF POLYETHYLENE SHEET OVER EXPANSION JOINTS WITH DOUBLE BEADS OF ADHESIVE EACH SIDE OF JOINT. 2. TAPE SEAL JOINTS BETWEEN SHEETS. 3. EXTEND SHEET FULL HEIGHT OF JOINT. 4. INSTALL BOARDS HORIZONTALLY ON WALLS. 5. PLACE BOARDS TO MAXIMIZE ADHESIVE CONTACT. 6. INSTALL IN RUNNING BOND PATTERN. 7. BUTT EDGES AND ENDS TIGHTLY TO ADJACENT BOARDS AND TO PROTRUSIONS. 8. EXTEND BOARDS OVER EXPANSION JOINTS, UNBONDED TO WALL ON ONE SIDE OF JOINT. 9. CUT AND FIT INSULATION TIGHTLY TO PROTRUSIONS OR INTERRUPTIONS TO THE INSULATION PLANE. 10. PLACE 6 INCH WIDE POLYETHYLENE SHEET AT PERIMETER OF WALL OPENINGS, FROM ADHESIVE VAPOR RETARDER BED TO WINDOW AND DOOR FRAMES. TAPE SEAL IN PLACE TO ENSURE CONTINUITY OF VAPOR RETARDER AND AIR SEAL. 11. TAPE INSULATION BOARD JOINTS. I. BOARD INSTALLATION AT CAVITY WALLS: 1. SECURE IMPALE FASTENERS TO SUBSTRATE AT A FREQUENCY OF 6 PER INSULATION BOARD. 2. ADHERE A 6 INCH WIDE STRIP OF POLYETHYLENE SHEET OVER EXPANSION JOINTS WITH DOUBLE BEADS OF ADHESIVE EACH SIDE OF JOINT. 3. TAPE SEAL JOINTS BETWEEN SHEETS. 4. EXTEND SHEET FULL HEIGHT OF JOINT. 5. INSTALL BOARDS TO FIT SNUGLY BETWEEN WALL TIES. 6. PLACE MEMBRANE SURFACE AGAINST ADHESIVE. 7. PLACE MEMBRANE SURFACE FACING OUT, AND TAPE SEAL BOARD JOINTS. 8. INSTALL BOARDS HORIZONTALLY ON WALLS. 9. PLACE BOARDS TO MAXIMIZE ADHESIVE CONTACT. 10. INSTALL IN RUNNING BOND PATTERN. 11. BUTT EDGES AND ENDS TIGHTLY TO ADJACENT BOARDS AND TO PROTRUSIONS. 12. PLACE IMPALE FASTENER LOCKING DISCS. 13. CUT AND FIT INSULATION TIGHTLY TO PROTRUSIONS OR INTERRUPTIONS TO THE INSULATION PLANE. 14. PLACE 6 INCH WIDE POLYETHYLENE SHEET AT PERIMETER OF WALL OPENINGS, FROM ADHESIVE VAPOR RETARDER BED TO WINDOW AND DOOR FRAMES. TAPE SEAL IN PLACE TO ENSURE CONTINUITY OF VAPOR RETARDER AND AIR SEAL. 07 2100 - THERMAL INSULATION (CONT.) J. BOARD INSTALLATION UNDER CONCRETE SLABS: 1. PLACE INSULATION UNDER SLABS ON GRADE AFTER BASE FOR SLAB HAS BEEN COMPACTED. 2. CUT AND FIT INSULATION TIGHTLY TO PROTRUSIONS OR INTERRUPTIONS TO THE INSULATION PLANE. 3. PREVENT INSULATION FROM BEING DISPLACED OR DAMAGED WHILE PLACING VAPOR RETARDER AND PLACING SLAB. K. BATT INSTALLATION: 1. INSTALL INSULATION AND VAPOR RETARDER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. INSTALL IN EXTERIOR WALL AND ROOF SPACES WITHOUT GAPS OR VOIDS. DO NOT COMPRESS INSULATION. 3. TRIM INSULATION NEATLY TO FIT SPACES. INSULATE MISCELLANEOUS GAPS AND VOIDS. 4. FIT INSULATION TIGHTLY IN CAVITIES AND TIGHTLY TO EXTERIOR SIDE OF MECHANICAL AND ELECTRICAL SERVICES WITHIN THE PLANE OF THE INSULATION. 5. AT WOOD FRAMING, PLACE VAPOR RETARDER ON WARM SIDE OF INSULATION BY STAPLING AT 6 INCHES ON CENTER. LAP AND SEAL SHEET RETARDER JOINTS OVER MEMBER FACE. 6. AT METAL FRAMING, PLACE VAPOR RETARDER ON WARM SIDE OF INSULATION; LAP AND SEAL SHEET RETARDER JOINTS OVER MEMBER FACE. 7. TAPE SEAL TEARS OR CUTS IN VAPOR RETARDER. 8. EXTEND VAPOR RETARDER TIGHTLY TO FULL PERIMETER OF ADJACENT WINDOW AND DOOR FRAMES AND OTHER ITEMS INTERRUPTING THE PLANE OF THE MEMBRANE. TAPE SEAL IN PLACE. L. PROTECTION: DO NOT PERMIT INSTALLED INSULATION TO BE DAMAGED PRIOR TO ITS CONCEALMENT. 07 2500 - WEATHER BARRIERS A. SECTION INCLUDES: 1. WEATHER BARRIER: UNDER EXTERIOR WALL CLADDING, OVER SHEATHING OR OTHER SUBSTRATE; NOT AIR -TIGHT OR VAPOR RETARDANT. 2. VAPOR RETARDERS: MATERIALS TO MAKE EXTERIOR WALLS, JOINTS BETWEEN EXTERIOR WALLS AND ROOF, JOINTS AROUND FRAMES OF OPENINGS IN EXTERIOR WALLS WATER VAPOR -RESISTANT AND AIR -TIGHT. B. WEATHER BARRIER ASSEMBLIES: 1. EXTERIOR WALLS: ON EXTERIOR SURFACE OF METAL FRAMED EXTERIOR WALL ASSEMBLIES USE WEATHER BARRIER / COATING BEHIND EXTERIOR CLADDING SYSTEM AS SHOWN AND SPECIFIED. 2. INTERIOR VAPOR RETARDER: ON INSIDE FACE OF STUDS OF EXTERIOR WALLS, UNDER CLADDING AND ON THE BOTTOM FACE OF RAFTERS, USE MECHANICALLY FASTENED VAPOR RETARDER SHEET. C. WEATHER BARRIER MATERIALS: (WATER VAPOR PERMEABLE AND WATER -RESISTIVE): AIR BARRIER SHEET, MECHANICALLY FASTENED MEETING THE FOLLOWING CRITERIA: 1. AIR PERMEANCE OF 0.004 CUBIC FEET PER SQUARE FOOT, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E 2178. 2. WATER VAPOR PERMEANCE: 5 PERMS, MINIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E96/E 96M. 3. WATER PENETRATION RESISTANCE: WITHSTAND A WATER HEAD OF 21 INCHES, MINIMUM, FOR MINIMUM OF 5 HOURS, WHEN TESTED IN ACCORDANCE WITH AATCC 127. 4. ULTRAVIOLET AND WEATHERING RESISTANCE: APPROVED IN WRITING BY MANUFACTURER FOR MINIMUM OF 9 MONTHS WEATHER EXPOSURE. 5. SURFACE BURNING CHARACTERISTICS: FLAME SPREAD INDEX OF 25 OR LESS, SMOKE DEVELOPED INDEX OF 50 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. 6. PRODUCTS: DUPONT COMPANY; TYVEK "COMMERCIAL WRAP", FIBERWEB, INC; "TYPAR METROWRAP", VAPROSHIELD, LLC; "WRAPSHIELD" OR APPROVED EQUAL. 7. AIR BARRIER COATING: COLD -FLUID -APPLIED, VAPOR PERMEABLE, ELASTOMERIC WATERPROOFING MEMBRANE DRY FILM THICKNESS 10 MILS MINIMUM. E. VAPOR RETARDER MATERIALS: VAPOR RETARDER SHEET MULTI -LAYER FABRIC CORD -,GRID -,OR ALUMINUM -REINFORCED POLYETHYLENE OR EQUIVALENT, COMPLYING WITH ASTM E 1745, CLASS A; STATED BY MANUFACTURER AS SUITABLE FOR APPLICATION INDICATED. SINGLE PLY POLYETHYLENE IS PROHIBITED. MATERIALS SHALL COMPLY WITH THE FOLLOWING CRITERIA: 1. WATER VAPOR PERMEANCE: 0.3 PERM, MAXIMUM, WHEN TESTED IN ACCORDANCE WITH ASTM E 96/E 96M. 2. VAPOR RETARDER TAPE: BRIGHT ALUMINUM SELF ADHERING TYPE MESH REINFORCED 2 INCHES WIDE COMPATIBLE WITH SHEET MATERIAL. 3. VAPOR RETARDER COATING: ELASTOMERIC BITUMEN MASTIC, ROLLER APPLIED. 4. MAXIMUM VAPOR PERMEABILITY (PERM): 1 NG/S/M/PA. F. SEALANTS: PRIMERS CLEANERS AND OTHER SEALANT MATERIALS: AS RECOMMENDED BY SEALANT MANUFACTURER, APPROPRIATE TO APPLICATION, AND COMPATIBLE WITH ADJACENT MATERIALS. G. ADHESIVES: 1. MASTIC ADHESIVE TYPE COMPATIBLE WITH SHEET SEAL AND SUBSTRATE, THICK MASTIC OF UNIFORM KNIFE GRADE CONSISTENCY. 2. NON -CURING ADHESIVE TYPE COMPATIBLE WITH SHEET SEAL AND SUBSTRATE, PERMANENTLY NON -CURING. H. PREPARATION: REMOVE PROJECTIONS, PROTRUDING FASTENERS, AND LOOSE OR FOREIGN MATTER THAT MIGHT INTERFERE WITH PROPER INSTALLATION. CLEAN AND PRIME SUBSTRATE SURFACES TO RECEIVE ADHESIVES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. I. INSTALLATION: INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. WATER -RESISTIVE BARRIERS: INSTALL CONTINUOUS BARRIER OVER SURFACES INDICATED, WITH SHEETS LAPPED TO SHED WATER BUT WITH SEAMS NOT SEALED. 2. AIR BARRIERS: INSTALL CONTINUOUS AIR -TIGHT BARRIER OVER SURFACES INDICATED, WITH SEALED SEAMS AND WITH SEALED JOINTS TO ADJACENT SURFACES. 3. VAPOR RETARDERS: INSTALL CONTINUOUS AIR -TIGHT BARRIER OVER SURFACES INDICATED, WITH SEALED SEAMS AND WITH SEALED JOINTS TO ADJACENT SURFACES. 4. MECHANICALLY FASTENED SHEETS - ON EXTERIOR: INSTALL SHEETS SHINGLE -FASHION TO SHED WATER. OVERLAP SEAMS AS RECOMMENDED BY MANUFACTURER BUT AT LEAST 6 INCHES. OVERLAP AT OUTSIDE AND INSIDE CORNERS AT LEAST 12 INCHES. 5. FOR APPLICATIONS SPECIFIED TO BE AIR -TIGHT, SEAL SEAMS, LAPS, PENETRATIONS, TEARS, AND CUTS WITH SELF-ADHESIVE TAPE; USE ONLY LARGE -HEADED, GASKETED FASTENERS RECOMMENDED BY THE MANUFACTURER. 6. INSTALL WATER -RESISTIVE BARRIER OVER JAMB FLASHINGS. 7. INSTALL AIR BARRIER AND VAPOR RETARDER UNDER JAMB FLASHINGS. 8. INSTALL HEAD FLASHINGS UNDER WEATHER BARRIER. 9. AT OPENINGS TO BE FILLED WITH FRAMES HAVING NAILING FLANGES, WRAP EXCESS SHEET INTO OPENING; AT HEAD, SEAL SHEET OVER FLANGE AND FLASHING. 10. MECHANICALLY FASTENED SHEETS - VAPOR RETARDER ON INTERIOR: WHEN INSULATION IS TO BE INSTALLED IN ASSEMBLY, INSTALL VAPOR RETARDER OVER INSULATION. ANCHOR TO WOOD FRAMING USING LARGE -HEADED NAILS OR STAPLES AT 12 TO 18 INCHES ON CENTER ALONG EACH FRAMING MEMBER COVERED; COVER FASTENERS WITH SEAM TAPE. SEAL SEAMS, LAPS, PERIMETER EDGES, PENETRATIONS, TEARS, AND CUTS WITH SELF-ADHESIVE TAPE, MAKING AIR -TIGHT SEAL. SEAL ENTIRE PERIMETER TO STRUCTURE, WINDOW AND DOOR FRAMES, AND OTHER PENETRATIONS. 11. WHERE CONDUIT, PIPES, WIRES, DUCTS, OUTLET BOXES, AND OTHER ITEMS ARE INSTALLED IN INSULATION CAVITY, PASS VAPOR RETARDER SHEET BEHIND ITEM BUT OVER INSULATION AND MAINTAIN AIR -TIGHT SEAL. 12. COATINGS: PREPARE SUBSTRATE IN MANNER RECOMMENDED BY COATING MANUFACTURER; FILL AND TAPE JOINTS IN SUBSTRATE AND BETWEEN DISSIMILAR MATERIALS. WHERE EXTERIOR MASONRY VENEER IS TO BE INSTALLED, INSTALL MASONRY ANCHORS BEFORE INSTALLING WEATHER BARRIER OVER MASONRY; SEAL AROUND ANCHORS AIRTIGHT. 13. MASTIC COATING: INSTALL BY TROWEL OR ROLLER TO MINIMUM THICKNESS OF 1/4 INCH; USE SHEET SEAL TO JOIN TO ADJACENT CONSTRUCTION, SEAL AIRTIGHT WITH SEALANT. 14. SPRAYED COATING: INSTALL TO THICKNESS RECOMMENDED BY MANUFACTURER. USE SELF-ADHESIVE SHEET FLASHING TO SEAL TO ADJACENT CONSTRUCTION AND TO BRIDGE JOINTS. 15. OPENINGS AND PENETRATIONS IN EXTERIOR WEATHER BARRIERS: INSTALL SELF-ADHESIVE FLASHING OVER SILLS, COVERING ENTIRE SILL FRAME MEMBER, EXTENDING AT LEAST 5 INCHES ONTO WEATHER BARRIER AND AT LEAST 6 INCHES UP JAMBS; MECHANICALLY FASTEN STRETCHED EDGES. AT OPENINGS TO BE FILLED WITH FRAMES HAVING NAILING FLANGES, SEAL HEAD AND JAMB FLANGES USING A CONTINUOUS BEAD OF SEALANT COMPRESSED BY FLANGE AND COVER FLANGES WITH SELF-ADHESIVE FLASHING AT LEAST 4 INCHES WIDE; DO NOT SEAL SILL FLANGE. AT OPENINGS TO BE FILLED WITH NON -FLANGED FRAMES, SEAL WEATHER BARRIER TO ALL SIDES OF OPENING FRAMING, USING SELF-ADHESIVE FLASHING AT LEAST 9 INCHES WIDE, COVERING ENTIRE DEPTH OF FRAMING. AT HEAD OF OPENINGS, INSTALL HEAD FRAME FLANGES AND SELF-ADHESIVE FLASHING UNDER WEATHER BARRIER EXTENDING AT LEAST 2 INCHES BEYOND FACE OF JAMBS; SEAL WEATHER BARRIER TO FLASHING. 16. SERVICE AND OTHER PENETRATIONS: FORM SELF-ADHESIVE FLASHING AROUND PENETRATING ITEM AND SEAL TO WEATHER BARRIER SURFACE. 07 7100 - ROOF SPECIALTIES A. SECTION INCLUDES: MANUFACTURED ROOF SPECIALTIES, INCLUDING COPINGS, FASCIAS, GRAVEL STOPS, VENTS, SNOW GUARDS, ROOF EXPANSION JOINT COVERS AND ROOF MEMBRANE VENTS. B. SUBMITTALS: PROVIDE PRODUCT DATA ON SHAPE OF COMPONENTS, MATERIALS AND FINISHES AND LOCATIONS. SUBMIT SHOP DRAWINGS INDICATING CONFIGURATIONS AND DIMENSIONS OF COMPONENTS, REQUIRED CLEARANCES AND TOLERANCES, AND OTHER AFFECTED WORK. C. QUALITY ASSURANCE: PERFORM WORK IN ACCORDANCE WITH SMACNA ARCHITECTURAL SHEET METAL MANUAL DETAILS. D. COMPONENTS: 1. COPINGS AND GRAVEL STOPS: EXTRUDED ALUMINUM, SHAPED AS INDICATED, INCLUDING SUPPORTS. INCLUDE COVER PLATES WITH A MILL FINISH, IN A COLOR AS SELECTED BY THE ARCHITECT, TO CONCEAL AND WEATHER SEAL JOINTS AND ATTACHMENT FLANGES. AS MANUFACTURED BY: METAL -ERA INC. OR APPROVED EQUAL. E. FINISHES: 1. CLEAR ANODIZED FINISH: AAMA 611 AA-M12C22A41 CLASS I CLEAR ANODIC COATING NOT LESS THAN 0.7 MILS THICK. 2. COLOR ANODIZED FINISH: AAMA 611 AA-M12C22A42/44 CLASS I INTEGRALLY OR ELECTROLYTICALLY COLORED ANODIC COATING NOT LESS THAN 0.7 MILS THICK. 3. BAKED ENAMEL: PIGMENTED ORGANIC COATING SYSTEM, AAMA 2603; POLYESTER BAKED ENAMEL FINISH SYSTEM; COLOR AS SCHEDULED. 4. FLUOROPOLYMER COATING: HIGH PERFORMANCE ORGANIC FINISH, AAMA 2604; MULTIPLE COATS, THERMALLY CURED FLUOROPOLYMER FINISH SYSTEM; COLOR AS SCHEDULED. F. EXAMINATION: VERIFY THAT DECK CURBS ROOF MEMBRANE BASE FLASHING AND OTHER ITEMS AFFECTING WORK OF THIS SECTION ARE IN PLACE AND POSITIONED CORRECTLY. G. INSTALLATION: INSTALL COMPONENTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONFORM TO SMACNA ARCHITECTURAL SHEET METAL MANUAL DRAWING DETAILS AS NOTED: COORDINATE INSTALLATION OF COMPONENTS OF THIS SECTION WITH INSTALLATION OF ROOFING MEMBRANE AND BASE FLASHINGS. COORDINATE INSTALLATION OF SEALANTS AND ROOFING CEMENT WITH WORK OF THIS SECTION TO ENSURE WATER TIGHTNESS. COORDINATE INSTALLATION OF FLASHING FLANGES INTO REGLETS. 07 6200 - SHEET METAL FLASHING AND TRIM A. GENERAL: PROVIDE METAL FLASHING AND SHEET METAL, INCLUDING ACCESSORIES AND FABRICATED SHEET METAL ITEMS TO MAKE A COMPLETE INSTALLATION INCLUDING CLIPS, PRE -FORMED CORNERS, JOINT COVERS, FLASHINGS, COUNTER -FLASHING, STEP FLASHING, CAP AND BASE FLASHING, GUTTERS, DOWNSPOUTS, SHEET METAL ROOFING, REGLETS, ACCESSORIES, AND ALL OTHER WORKS SHOWN OR SPECIFIED. B. QUALITY ASSURANCE: ALL MATERIALS AND INSTALLATION PRACTICES SHALL CONFORM TO THE LATEST EDITIONS OF THE SMACNA ARCHITECTURAL SHEET METAL MANUAL, AND THE NATIONAL ROOFING CONTRACTORS ASSOCIATION MANUAL OF PRACTICE. C. DELIVERY, STORAGE, AND HANDLING: STACK MATERIAL TO PREVENT TWISTING, BENDING, AND ABRASION, AND TO PROVIDE VENTILATION. SLOPE METAL SHEETS TO ENSURE DRAINAGE. PREVENT CONTACT WITH MATERIALS THAT COULD CAUSE DISCOLORATION OR STAINING. D. MATERIALS: 1. GALVANIZED STEEL: ASTM A 653, WITH G90 ZINC COATING; MINIMUM 0.02 INCH THICK BASE METAL. 2. ALUMINUM: ASTM B 209; 0.032 INCH THICK; ANODIZED FINISH OF COLOR AS SELECTED. 3. CLEAR ANODIZED FINISH: AAMA 611 AA-M12C22A41 CLASS I CLEAR ANODIC COATING NOT LESS THAN 0.7 MILS THICK. 4. COLOR ANODIZED FINISH: AAMA 611 AA-M12C22A42/44 CLASS I INTEGRALLY OR ELECTROLYTICALLY COLORED ANODIC COATING NOT LESS THAN 0.7 MILS THICK. 5. PRE -FINISHED ALUMINUM: ASTM B 209; 0.032 INCH THICK; PLAIN FINISH SHOP PRE COATED WITH FLUOROPOLYMER COATING OF COLOR AS SELECTED. 6. FLUOROPOLYMER COATING: HIGH PERFORMANCE ORGANIC FINISH, AAMA 2604; MULTIPLE COATS, THERMALLY CURED FLUOROPOLYMER FINISH SYSTEM; COLOR AS SCHEDULED. 7. PRE -FINISHED METAL: ZINC -COATED GALVANIZED STEEL, 20% COPPER (ASTM A525) G90 HOT -DIPPED GALVANIZED, MILL PHOSPHATIZED. LOCK FORMING QUALITY AS REQUIRED, 24 GUAGE. KYNAR 500 SMOOTH FINISH IN COLOR AS SELECTED BY ARCHITECT. THE FINISH SHALL HAVE A 20 YEAR WARRANTY. 8. COPPER: (ASTM B370) COLD -ROLLED, EXCEPT WHERE SOFT TEMPERED IS REQUIRED FOR FORMING, 16 oz. PER SQUARE FOOT, NATURAL FINISH, H00 TEMPER. 9. SOLDER: FOR USE WITH STEEL OR COPPER ONLY. PROVIDE 50-50 TIN/LEAD SOLDER (ASTM B 32),WITH ROSIN FLUX. 10. FASTENERS: USE SAME METAL AS FLASHING / SHEET METAL OR OTHER NON -CORROSIVE METAL AS RECOMMENDED BY SHEET METAL MANUFACTURER. MATCH FINISH OF EXPOSED HEADS WITH MATERIAL BEING FASTENED. 11. REGLETS: METAL OR PLASTIC UNITS OF THE TYPE AND PROFILE INDICATED, COMPATIBLE WITH FLASHING INDICATED, NON -CORROSIVE. 12. METAL ACCESSORIES: PROVIDE SHEET METAL CLIPS, STRAPS, ANCHORING DEVICES AND SIMILAR ACCESSORY UNITS AS REQUIRED FOR INSTALLATION OF WORK, MATCHING THE MATERIAL BEING INSTALLED, NON -CORROSIVE, SIZE AND GUAGE REQUIRED FOR PERFORMANCE. E. ACCESSORIES: 1. FASTENERS: GALVANIZED STEEL, WITH SOFT NEOPRENE WASHERS. 2. PRIMER: ZINC CHROMATE TYPE. 3. PROTECTIVE BACKING PAINT: ZINC MOLYBDATE ALKYD. 4. PLASTIC CEMENT: ASTM D 4586, TYPE I. 5. SNOW GUARDS: PETERSEN PAC -CLAD S-5 COLOR GARD SNOW RETENTION SYSTEM, CONTINUOUS ALONG LENGTH OF METAL ROOFING. F. SNOW GUARDS: TO BE SNO GEM "1" SQUARE SNO BLOCKADE SNO RETENTION SYSTEM" (OR EQUAL) FENCE -TYPE CONTINUOUS SNOW GUARD; RAILING SET IN BRACKETS CONNECTED TO ROOF SEAMS. MOUNT SNOW GUARD SYSTEMS 8 INCHES FROM THE EAVES BY USE OF CLAMPS ATTACHED TO STANDING SEAMS OF ROOF PANELS. SPACE CLAMPS AS RECOMMENDED BY MFR. PROTECT ENTIRE LOW EAVE SIDE OF ROOF, CONTINUOUS. MATCH PRE -FINISHED ROOF COLOR. G. GUTTER AND DOWNSPOUT FABRICATION: 1. GUTTERS AND DOWNSPOUTS PROVIDED BY PRE-ENGINEERED METAL BUILDING SUPPLIER. H. PREPARATION: INSTALL STARTER AND EDGE STRIPS, AND CLEATS BEFORE STARTING INSTALLATION. BACK PAINT CONCEALED METAL SURFACES WITH PROTECTIVE BACKING PAINT TO A MINIMUM DRY FILM THICKNESS OF 15 MIL. I. INSTALLATION: 1. EXCEPT WHERE OTHERWISE INDICATED, ALL INSTALLATIONS SHALL COMPLY WITH MANUFACTURER'S RECOMMENDATIONS, AND WITH SMACNA "ARCHITECTURAL SHEET METAL MANUAL". 2. INSERT FLASHINGS INTO REGLETS TO FORM TIGHT FIT. SECURE IN PLACE WITH LEAD WEDGES. PACK REMAINING SPACES WITH LEAD WOOL. SEAL FLASHINGS INTO REGLETS WITH SEALANT. 3. SECURE FLASHINGS IN PLACE USING CONCEALED FASTENERS. USE EXPOSED FASTENERS ONLY WHERE PERMITTED. 4. APPLY PLASTIC CEMENT COMPOUND BETWEEN METAL FLASHINGS AND FELT FLASHINGS. 5. BED FLANGES OF WORK IN A THICK COAT OF BITUMINOUS ROOFING CEMENT WHERE REQUIRED FOR WATERPROOFING PERFORMANCE. 6. FIT FLASHINGS TIGHT IN PLACE. MAKE CORNERS SQUARE, SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES ACCURATE TO PROFILES. 7. SEAL METAL JOINTS WATERTIGHT. 8. CLEAN EXPOSED METAL SURFACES, REMOVING SUBSTANCES WHICH MIGHT CAUSE CORROSION OF METAL OR DETERIORATION OF FINISHES. CERTIFIED BY: i� "��roGE� `R N10 = 0 900019 0 = S 0 TATE F k4.� • No I AN . 1. '/. R \\\ i Lu W c N QQ co C)O (O O LL V Z W O z Q Z ii--0- Z = C)_ w J Q OZ � w o Z0 0 F___ U z O� J Z - Q zU) < Q 2-i O J =� U w W 3: LU Z 2i w z J �� J co O) U 2 DRAWING ARCHITECTURAL SPECIFICATIONS ISSUE 100% CONST. DOCUMENTS - 05/15/2020 90% CONST. DOCUMENTS - 04/01/2020 DESIGN DEVELOPMENT SET-01/16/2020 REVISIONS 1 - 2 - 3 - 4 - PROJECT NUMBER 1832 DATE MAY 15, 2020