08 8100 - GLAZING
A. SUMMARY: PROVIDE GLASS, GLAZING AND ACCESSORIES AS SHOWN, SPECIFIED AND REQUIRED.
B. QUALITY ASSURANCE: PROVIDE GLASS AND GLAZING THAT HAS BEEN PRODUCED, FABRICATED AND
INSTALLED TO WITHSTAND NORMAL THERMAL MOVEMENT, WIND LOADING AND IMPACT LOADING
(WHERE APPLICABLE), WITHOUT FAILURE INCLUDING LOSS OR BREAKAGE OF GLASS, FAILURE OF
SEALANTS OR GASKETS TO REMAIN WATERTIGHT AND AIRTIGHT, DETERIORATION OF GLASS AND
GLAZING MATERIALS AND OTHER DEFECTS IN THE WORK.
C. SUBMITTALS: SUBMIT MANUFACTURER'S SPECIFICATIONS AND TECHNICAL DATA FOR EACH GLAZING
MATERIAL AND FABRICATED GLASS PRODUCT REQUIRED, INCLUDING INSTALLATION AND
MAINTENANCE INSTRUCTIONS.
D. PRODUCT DELIVERY, STORAGE AND HANDLING: PROTECT GLASS AND GLAZING MATERIALS DURING
DELIVERY, STORAGE AND HANDLING TO COMPLY WITH MANUFACTURER'S DIRECTIONS AND AS
REQUIRED TO PREVENT ANY DAMAGE TO GLASS AND GLAZING UNITS.
E. WARRANTY: THE WINDOW MANUFACTURER SHALL PROVIDE A MINIMUM TEN (10) YEAR WARRANTY
FOR THE COMPLETE AND TOTAL INSULATED GLAZING UNIT ASSEMBLY FROM SEAL FAILURE.
DEFECTIVE MATERIAL SHALL BE REPLACED IN FULL.
F. MATERIALS:
1. CLEAR GLASS: FLOAT, TRANSPARENT GLASS -FLAT, CLEAR, GLAZING SELECT, 1/4" THICKNESS.
2. INSULATING GLASS: ASTM E774, CLASS A, PRE -ASSEMBLED UNITS CONSISTING OF SEALED
PANES OF GLASS ENCLOSING A HERMETICALLY SEALED DEHYDRATED AIR SPACE, WITH
SEALING SYSTEM, SPACER MATERIAL, DESICCANT AND CORNER CONSTRUCTION PER
MANUFACTURER'S STANDARDS. SEE WINDOW SCHEDULE AND ELEVATIONS FOR TYPE OF
GLAZING. ALL EXTERIOR GLASS TO BE BRONZE TINTED.
3. FROSTED GLASS: PROVIDE FROSTED, ETCHED GLASS ON INTERIOR SIDE OF INSULATED UNITS
TO OBSCURE VISIONS WHERE INDICATED ON WINDOW ELEVATIONS.
4. GLAZING TAPE: POLYISOBUTYLENE-BUTYL.
5. SINGLE GLAZING: TREMCO 440 TAPE, COLOR AS REQUIRED.
6. SEALANTS: ASTM C920, CHEMICALLY CURING, ELASTOMERIC SILICONE OR URETHANE AS
APPROPRIATE; THE FOLLOWING ARE APPROVED MANUFACTURERS: DOW "999", G.E. "SCS 1200",
PECORA "863", SONNEBORN "OMNIGLAZE", TREMCO "PROGLAZE" OR APPROVED EQUAL.
G. MISCELLANEOUS GLAZING MATERIALS: PROVIDE MATERIALS WITH PROVEN RECORD OF
COMPATIBILITY WITH SURFACES CONTACTED IN INSTALLATION.
1. CLEANERS, PRIMERS AND SEALERS: TYPE RECOMMENDED BY SEALANT OR GASKET
MANUFACTURER.
2. SETTING BLOCKS: NEOPRENE, EPDM OR SILICONE BLOCKS AS REQUIRED FOR COMPATIBILITY
WITH GLAZING SEALANTS, 80 TO 90 SHORE A DUROMETER HARDNESS.
3. SPACERS: NEOPRENE, EPDM OR SILICONE BLOCKS, OR CONTINUOUS EXTRUSIONS, AS
REQUIRED FOR COMPATIBILITY WITH GLAZING SEALANT, AND AS RECOMMENDED BY GLASS
MANUFACTURER FOR APPLICATION INDICATED.
4. EDGE BLOCKS: NEOPRENE, EPDM OR SILICONE BLOCKS AS REQUIRED FOR COMPATIBILITY
WITH GLAZING SEALANT, OF SIZE AND HARDNESS REQUIRED TO LIMIT LATERAL MOVEMENT.
H. PREPARATION: CLEAN GLAZING CHANNELS AND OTHER FRAMING MEMBERS TO RECEIVE GLASS,
IMMEDIATELY BEFORE GLAZING. REMOVE COATINGS THAT ARE NOT FIRMLY BONDED TO
SUBSTRATES.
I. INSTALLATION:
1. INSTALLATION SHALL BE ACCORDING TO MANUFACTURER'S SPECIFICATIONS, AND
RECOMMENDATIONS FOR WORK BEING INSTALLED. PROVIDE GLAZING CLIPS, SETTING BLOCKS,
SHIMS, ACCESSORIES, ETC.
2. MAINTAIN 40 DEGREES F MINIMUM TEMPERATURE DURING APPLICATION OF SEALANTS.
3. GLAZE WORK IN ACCORD WITH TYPE OF SYSTEM INDICATED ABOVE. IF SASH DETAIL VARIES
FROM THAT INDICATED DO NOT PROCEED UNTIL PROPER PROCEDURE IS DETERMINED.
4. GLAZING TAPE: CUT TAPE TO PROPER LENGTH BEFORE APPLICATION, APPLY AGAINST
PERMANENT STOPS. SET HEAD AND SILL FIRST, USING FULL LENGTH PIECES, WELD CORNERS
TOGETHER BY TIGHTLY BUTTING TAPE. CRIMP BUTT JOINTS 3 TIMES TO INSURE WELD. SET
GLASS ON SETTING BLOCKS, ALIGN EDGES AND SHOVE HOME, PRESSING SECURELY INTO TAPE
TO INSURE CONTACT AND ADHESION AT ALL POINTS.
5. HEEL SEALING: APPLY HEEL BEAD OF SEALANT AROUND PERIMETER OF GLASS, MAINTAINING
3/16" MINIMUM BITE ON GLASS AND POSITIVE BOND TO SASH. COMPLETELY SEAL VOID AROUND
GLASS MAKE BEAD LARGE ENOUGH SO THAT IT PARTIALLY FILLS CHANNEL BETWEEN GLASS
AND REMOVABLE STOPS WHEN THEY ARE SET. INSTALL SNAP OR SCREW -ON STOPS AS
APPROPRIATE.
6. FACE SEALING: PLACE SPACER SHIMS OF PROPER THICKNESS SO THAT PRESSURE FROM STOP
TO GLASS IS MAINTAINED THRU SHIM AND SO THAT GLASS IS IN COMPRESSION AGAINST TAPE
SHIMS NOT LESS THAN 1/4" BELOW SITE LINE. SET REMOVABLE STOP AND FILL CHANNEL WITH
SEALANT TO SITE LINE.
7. REMOVE GLASS LABELS WHEN DIRECTED, AFTER INSPECTION BY ARCHITECT.
8. REPLACE CRACKED, BROKEN OR DEFECTIVE GLASS.
9. WASH GLASS BOTH INSIDE AND OUT, REMOVING PAINT SPOTS, PUTTY MARKS, ETC., LEAVING
08 910(fN0E IbIt ftT CONDITION.
A. SECTION INCLUDES: LOUVERS, FRAMES, AND ACCESSORIES.
B. SUBMITTALS: PROVIDE DATA DESCRIBING DESIGN CHARACTERISTICS, MAXIMUM RECOMMENDED AIR
VELOCITY, DESIGN FREE AREA, MATERIALS AND FINISHES. SUBMIT SHOP DRAWINGS THAT INDICATE
LOUVER LAYOUT PLAN AND ELEVATIONS, OPENING AND CLEARANCE DIMENSIONS, HEAD, JAMB AND
SILL DETAILS; BLADE CONFIGURATION, SCREENS, BLANKOUT AREAS REQUIRED, AND FRAMES.
C. WARRANTY: PROVIDE TEN YEAR MANUFACTURER WARRANTY AGAINST DISTORTION, METAL
DEGRADATION, AND FAILURE OF CONNECTIONS. INCLUDE COVERAGE AGAINST DEGRADATION OF
EXTERIOR FINISH.
D. MANUFACTURERS: THE FOLLOWING ARE APPROVED MANUFACTURERS: INDUSTRIAL LOUVERS, INC.,
GREENHECK, RELIABLE PRODUCTS INC., AIROLITE COMPANY, LLC, CONSTRUCTION SPECIALTIES, INC.
OR APPROVED EQUAL.
E. LOUVERS: FACTORY FABRICATED AND ASSEMBLED, COMPLETE WITH FRAME, MULLIONS, AND
ACCESSORIES; AMCA CERTIFIED UNDER AMCA 511.
1. INTAKE LOUVERS: DESIGN TO ALLOW MAXIMUM OF 0.01 OZ/SQ FT WATER PENETRATION AT
CALCULATED INTAKE DESIGN VELOCITY BASED ON DESIGN AIR FLOW AND ACTUAL FREE AREA,
WHEN TESTED IN ACCORDANCE WITH AMCA 500-L.
2. DRAINABLE BLADES: CONTINUOUS RAIN STOP AT FRONT OR REAR OF BLADE ALIGNED WITH
VERTICAL GUTTER RECESSED INTO BOTH JAMBS OF FRAME.
3. SCREENS: PROVIDE INSECT SCREENS AT INTAKE LOUVERS AND BIRD SCREENS AT EXHAUST
LOUVERS.
F. STATIONARY LOUVERS: HORIZONTAL BLADE, EXTRUDED ALUMINUM CONSTRUCTION, WITH
INTERMEDIATE MULLIONS MATCHING FRAME.
1. FREE AREA: 50 PERCENT, MINIMUM.
2. BLADES: STRAIGHT.
3. FRAME: 4 INCHES DEEP, CHANNEL PROFILE; CORNER JOINTS MITERED AND MECHANICALLY
FASTENED, WITH CONTINUOUS RECESSED CAULKING CHANNEL EACH SIDE.
4. METAL THICKNESS: FRAME 0.081 INCH; BLADES 0.081 INCH.
5. COLOR: AS SELECTED FROM MANUFACTURER'S STANDARDS.
G. MATERIALS:
1. EXTRUDED ALUMINUM: ASTM B 221.
2. COLOR ANODIZING: AAMA 611 CLASS I.
3. STEEL SHEET: HOT -DIPPED GALVANIZED STEEL SHEET, ASTM A 653, WITH G90 COATING.
4. BIRD SCREEN: INTERWOVEN WIRE MESH OF STEEL, 0.063" DIAMETER WIRE, 1/2 INCH OPEN
WEAVE, DIAGONAL DESIGN.
5. INSECT SCREEN: 18 X 16 SIZE ALUMINUM MESH.
6. POLYVINYLIDENE FLUORIDE COATING: MINIMUM 70 PERCENT KYNAR 500/HYLAR 500 RESIN, TWO
COAT FINISH, COMPLYING WITH AAMA 2604.
7. PRIMER: ZINC CHROMATE, ALKYD TYPE.
I. ACCESSORIES:
1. BLANK -OFF PANELS: SAME MATERIAL AS LOUVER, PAINTED BLACK ON EXTERIOR SIDE; PROVIDE
WHERE DUCT CONNECTED TO LOUVER IS SMALLER THAN LOUVER FRAME, SEALING OFF
LOUVER AREA OUTSIDE DUCT.
2. SCREENS: FRAME OF SAME MATERIAL AS LOUVER, WITH REINFORCED CORNERS; REMOVABLE,
SCREW ATTACHED; INSTALLED ON INSIDE FACE OF LOUVER FRAME.
3. FASTENERS AND ANCHORS: GALVANIZED STEEL.
4. FLASHINGS: OF SAME MATERIAL AS LOUVER FRAME, FORMED TO REQUIRED SHAPE, SINGLE
LENGTH IN ONE PIECE PER LOCATION.
08 9100 - LOUVERS (CONT.)
J. INSTALLATION:
1. INSTALL LOUVER ASSEMBLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
2. INSTALL LOUVERS LEVEL AND PLUMB.
3. INSTALL FLASHINGS AND ALIGN LOUVER ASSEMBLY TO ENSURE MOISTURE SHED FROM
FLASHINGS AND DIVERSION OF MOISTURE TO EXTERIOR.
4. SECURE LOUVER FRAMES IN OPENINGS WITH CONCEALED FASTENERS.
5. INSTALL PERIMETER SEALANT AND BACKING RODS.
6. COORDINATE WITH INSTALLATION OF MECHANICAL DUCTWORK AND LOUVER ACTUATORS.
K. ADJUSTING: ADJUST OPERABLE LOUVERS FOR FREEDOM OF MOVEMENT OF CONTROL MECHANISM.
LUBRICATE OPERATING JOINTS.
L. CLEANING: STRIP PROTECTIVE FINISH COVERINGS. CLEAN SURFACES AND COMPONENTS.
09 2116 - GYPSUM BOARD ASSEMBLIES
A. SECTION INCLUDES: PERFORMANCE CRITERIA FOR GYPSUM BOARD ASSEMBLIES INCLUDING; METAL
STUD WALL FRAMING, METAL CHANNEL CEILING FRAMING, SHAFT WALL SYSTEMS, GYPSUM
SHEATHING, CEMENTITIOUS BACKING BOARD, GYPSUM WALLBOARD, AND JOINT TREATMENTS AND
ACCESSORIES.
B. SUBMITTALS: PROVIDE DATA ON METAL FRAMING, GYPSUM BOARD, ACCESSORIES, AND JOINT
FINISHING SYSTEM.
C. GYPSUM BOARD ASSEMBLIES: PROVIDE COMPLETED ASSEMBLIES COMPLYING WITH ASTM C 840
AND GA-216:
1. NON-LOADBEARING FRAMING SYSTEM COMPONENTS: ASTM C 645; GALVANIZED SHEET STEEL,
OF SIZE AND PROPERTIES NECESSARY TO COMPLY WITH ASTM C 754 FOR THE SPACING
INDICATED, WITH MAXIMUM DEFLECTION OF WALL FRAMING OF L/240 AT 5 PSF (OR 40 KSI STEEL
EQUIVALENT). AS MANUFACTURED BY DIETRICH METAL FRAMING; "ULTRASTEEL", CLARK
WESTERN BUILDING SYSTEMS; "ULTRASTEEL" OR APPROVED EQUAL.
a. STUDS: "C" SHAPED WITH FLAT OR FORMED WEBS WITH KNURLED FACES.
b. RUNNERS: U SHAPED, SIZED TO MATCH STUDS.
C. CEILING CHANNELS: C SHAPED.
d. FURRING: HAT -SHAPED SECTIONS, MINIMUM DEPTH OF 7/8 INCH.
2. SHAFT WALL STUDS AND ACCESSORIES: ASTM C 645; GALVANIZED SHEET STEEL, OF SIZE AND
PROPERTIES NECESSARY TO COMPLY WITH ASTM C 754 AND SPECIFIED PERFORMANCE
REQUIREMENTS. MANUFACTURERS SHALL BE THE SAME AS OTHER FRAMING MATERIALS
PROVIDERS.
3. PARTITION HEAD TO STRUCTURE CONNECTIONS: PROVIDE MECHANICAL ANCHORAGE DEVICES
THAT ACCOMMODATE DEFLECTION USING SLOTTED HOLES, SCREWS AND ANTI -FRICTION
BUSHINGS, PREVENTING ROTATION OF STUDS WHILE MAINTAINING STRUCTURAL
PERFORMANCE OF PARTITION.
4. STRUCTURAL PERFORMANCE: MAINTAIN LATERAL LOAD RESISTANCE AND VERTICAL
MOVEMENT CAPACITY REQUIRED BY APPLICABLE CODE, WHEN EVALUATED IN ACCORDANCE
WITH AISI NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL
STRUCTURAL MEMBERS.
5. PROVIDE COMPONENTS UL-LISTED FOR USE IN FIRE -RATED PARTITION SYSTEMS AS INDICATED.
6. DEFLECTION AND FIRESTOP TRACK: PROVIDE MECHANICAL ANCHORAGE DEVICES THAT
ACCOMMODATE DEFLECTION WHILE MAINTAINING THE FIRE -RATING OF THE WALL ASSEMBLY.
ACCEPTABLE PRODUCTS INCLUDE; "POSI CLIP" BY FIRE TRAK CORPORATION, "THE SYSTEM" BY
METAL-LITE, INC, OR APPROVED EQUAL. PROVIDE TOP TRACK PREASSEMBLED WITH
CONNECTION DEVICES SPACED TO FIT STUD SPACING INDICATED ON DRAWINGS; MINIMUM
TRACK LENGTH OF 12 FEET.
D. BOARD MATERIALS: ALL BOARD MATERIALS SHALL HAVE A MOLD RESISTANCE SCORE OF 10, WHEN
TESTED IN ACCORDANCE WITH ASTM D 3273. ACCEPTABLE MANUFACTURERS SHALL BE: AMERICAN
GYPSUM, CERTAINTEED CORPORATION, GEORGIA-PACIFIC GYPSUM, NATIONAL GYPSUM COMPANY,
USG CORPORATION OR APPROVED EQUAL.
1. WALLBOARD: PAPER -FACED GYPSUM WALLBOARD AS DEFINED IN ASTM C 1396/C 1396M; SIZES
TO MINIMIZE JOINTS IN PLACE; ENDS SQUARE CUT. FOR USE AT VERTICAL SURFACES AND
CEILINGS.
a. GLASS -MAT -FACED GYPSUM PANELS AS DEFINED IN ASTM C 1658/C 1658M, SUITABLE FOR
PAINT FINISH, OF THE SAME CORE TYPE AND THICKNESS MAY BE SUBSTITUTED FOR
PAPER -FACED BOARD.
b. FIRE -RATED ASSEMBLIES: TYPE X BOARD, UL LISTED TO MEET REQUIRED ASSEMBLY
RATING.
c. THICKNESS AND THE NUMBER OF LAYERS USED SHALL BE AS INDICATED ON THE
DRAWINGS.
2. IMPACT -RATED WALLBOARD: TESTED TO LEVEL 3 SOFT -BODY AND HARD -BODY IMPACT IN
ACCORDANCE WITH ASTM C 1629. FOR USE AT HIGH -TRAFFIC AREAS INDICATED.
a. PAPER -FACED TYPE: GYPSUM WALLBOARD AS DEFINED IN ASTM C 1396.
b. TYPE: FIRE -RESISTANCE RATED TYPE X, UL LISTED.
c. BOARD PROPERTIES: 5/8 INCH THICK, WITH TAPERED EDGES.
d. PRODUCTS: NATIONAL GYPSUM COMPANY; "GOLD BOND HI -IMPACT BRAND XP
WALLBOARD", USG CORPORATION; "FIBEROCK BRAND PANELS--VHI ABUSE -RESISTANT" OR
APPROVED EQUAL.
3. BACKING BOARD FOR WET AREAS: TO BE USED ON SURFACES BEHIND TILE IN WET AREAS
INCLUDING TUB AND SHOWER SURROUNDS SHOWER CEILINGS AND TOILET ROOM WET WALLS.
a. CEMENT -BASED BOARD: NON -GYPSUM -BASED; AGGREGATED PORTLAND CEMENT PANELS
WITH GLASS FIBER MESH EMBEDDED IN FRONT AND BACK SURFACES COMPLYING WITH
ANSI A118.9 OR ASTM C 1325. BOARD THICKNESS TO BE 1/2". ACCEPTABLE PRODUCTS:
CUSTOM BUILDING PRODUCTS; "WONDERBOARD", NATIONAL GYPSUM COMPANY;
"PERMABASE" OR "PERMABASE FLEX", USG CORPORATION; "DUROCK" , OR APPROVED
EQUAL.
b. CEMENT -BASED BOARD: NON -GYPSUM -BASED, CEMENTITIOUS BOARD COMPLYING WITH
ASTM C 1288. BOARD TO BE 1/2" THICK. ACCEPTABLE PRODUCTS: JAMES HARDIE
BUILDING PRODUCTS, INC; "HARDIBACKER" OR APPROVED EQUAL.
C. GLASS -MAT -FACED BOARD: COATED GLASS MAT WATER-RESISTANT GYPSUM BACKING
PANEL AS DEFINED IN ASTM C 1178. BOARD TO BE 1/2" THICK.
d. FIRE-RESISTANT TYPE: TYPE X CORE, THICKNESS 5/8 INCH. ACCEPTABLE PRODUCTS:
GEORGIA-PACIFIC GYPSUM LLC; "DENSSHIELD" OR APPROVED EQAUL.
4. BACKING BOARD FOR NON -WET AREAS: WATER-RESISTANT GYPSUM BACKING BOARD AS
DEFINED IN ASTM C 1396; MINIMIZE JOINTS IN PLACE; ENDS SQUARE CUT WITH TAPERED EDGES.
a. APPLICATION: ALL VERTICAL SURFACES BEHIND THINSET TILE, EXCEPT IN WET AREAS.
b. BOARD THICKNESSES: TYPE X TO BE 5/8" THICK, AND REGULAR BOARD TO BE 1/2" THICK.
5. CEILING BOARD: SPECIAL SAG -RESISTANT GYPSUM CEILING BOARD AS DEFINED IN ASTM C 1396;
1/2" THICK, SIZED TO MINIMIZE JOINTS IN PLACE; ENDS SQUARE CUT, AND TAPERED
EDGES.EXTERIOR
6. GLASS -MAT -FACED SHEATHING: GLASS MAT FACED GYPSUM SUBSTRATE AS DEFINED IN ASTM
C 1177. SQUARE EDGES FOR VERTICAL APPLICATIONS
a. BOARD THICKNESSES: TYPE X TO BE 5/8", AND REGULAR BOARD TO BE 1/2".
b. PRODUCTS: CERTAINTEED CORPORATION; "GLASROC", GEORGIA-PACIFIC GYPSUM;
"DENSGLASS GOLD", NATIONAL GYPSUM COMPANY; "GOLD BOND BRAND E2XP EXTENDED
EXPOSURE SHEATHING" OR APPROVED EQUAL.
D. ACCESSORY FINISH MATERIALS: WHERE SHOWN ON THE DRAWINGS, PROVIDE FIBER REINFORCED
POLYMER (FRP) SHEET MATERIAL FINISH SYSTEM, INCLUDING ALL ACCESSORIES.
a. COLOR: WHITE
b. FINISH: TEXTURED
E. ACCESSORIES:
7. ACOUSTIC INSULATION: ASTM C 665; PREFORMED GLASS FIBER, FRICTION FIT TYPE, UNFACED.
8. ACOUSTIC SEALANT: NON -HARDENING, NON -SKINNING, FOR USE IN CONJUNCTION WITH
GYPSUM BOARD.
9. WATER -RESISTIVE BARRIER: NO. 15 ASPHALT FELT.
10. FINISHING ACCESSORIES: ASTM C 1047, GALVANIZED STEEL OR ROLLED ZINC. TYPES AS
DETAILED OR REQUIRED FOR FINISHED APPEARANCE. PROVIDE SPECIAL SHAPES IN ADDITION
TO CONVENTIONAL CORNERBEAD AND CONTROL JOINTS, PROVIDE U-BEAD AT EXPOSED PANEL
EDGES.
11. JOINT MATERIALS: ASTM C 475 AND AS RECOMMENDED BY GYPSUM BOARD MANUFACTURER
FOR PROJECT CONDITIONS.
12. TAPE: 2 INCH WIDE, COATED GLASS FIBER, AND CREASED PAPER, TAPE FOR JOINTS AND
CORNERS.
13. READY -MIXED AND/OR POWDER -TYPE VINYL -BASED JOINT COMPOUNDS.
14. CHEMICAL HARDENING TYPE COMPOUND.
15. TEXTURED FINISH MATERIALS: LATEX -BASED COMPOUND; PLAIN.
16. HIGH BUILD DRYWALL SURFACER: VINYL ACRYLIC LATEX -BASED COATING FOR SPRAY
APPLICATION, DESIGNED TO TAKE THE PLACE OF SKIM COATING AND SEPARATE PAINT PRIMER
IN ACHIEVING LEVEL 5 FINISH.
17. TEXTURED FINISH MATERIALS: LATEX -BASED COMPOUND; PLAIN.
18. SCREWS FOR ATTACHMENT TO STEEL MEMBERS LESS THAN 0.03" IN THICKNESS, TO WOOD
MEMBERS, AND TO GYPSUM BOARD: ASTM C 1002; SELF -PIERCING TAPPING TYPE;
CADMIUM -PLATED FOR EXTERIOR LOCATIONS.
19. ANCHORAGE TO SUBSTRATE: TIE WIRE, NAILS, SCREWS, AND OTHER METAL SUPPORTS, OF
TYPE AND SIZE TO SUIT APPLICATION; TO RIGIDLY SECURE MATERIALS IN PLACE.
09 2200 - SUPPORTS FOR GYPSUM BOARD
A. SECTION INCLUDES: NON-STRUCTURAL METAL SUPPORTING SYSTEMS FOR DRYWALL, AND
ACCESSORIES AS SHOWN AND SPECIFIED.
B. SUBMITTALS: SUBMIT MANUFACTURER'S TECHNICAL LITERATURE, SPECIFICATIONS AND
INSTALLATION INSTRUCTIONS.
C. STANDARD METAL STUDS AND RUNNERS: 25 GAUGE, 22 GAUGE OR 20 GAUGE CHANNEL TYPE,
GALVANIZED STEEL, NON -LOAD BEARING, DESIGNED FOR SCREW ATTACHMENT OF GYPSUM
WALLBOARD. ASTM C645-88 AND FS QQ-S-698.
1. WIDTHS AND SPACING SHALL BE AS INDICATED ON THE DRAWINGS.
2. PROVIDE THE FOLLOWING GAUGE STUDS FOR THE SCHEDULED HEIGHT LIMITATIONS AS
FOLLOWS:
a. 25 GAUGE- UP T012' HIGH.
b. 22 GAUGE- UP T014' HIGH.
c. 20 GAUGE- UP T015'6" HIGH
d. OVER 15'6" HIGH - REFER TO STRUCTURAL DRAWINGS.
3. CARRYING CHANNELS: 1 1/2" COLD -ROLLED STEEL CHANNELS FOR SCREW ATTACHMENT OF
GYPSUM WALLBOARD, 16 GAUGE, PAINTED, ASTM C1063, GALVANIZED AT EXTERIOR LOCATIONS.
PROVIDE HORIZONTAL CHANNEL BRACING FOR PARTITIONS AT 4' O.C. VERTICALLY.
4. DEFLECTION TRACKS: PROVIDE METAL STUD RUNNERS AT THE TOP OF ALL METAL STUD WALLS
TO ISOLATE THE PARTITION WALL TO ALLOW FOR EXPANSION AND MOVEMENT.
5. FURRING CHANNELS: 20 GAUGE, ROLL FORMED, GALVANIZED STEEL HAT SHAPED OR Z
FURRING CHANNELS FOR SCREW ATTACHMENT OF GYPSUM WALLBOARD, ASTM C645-88.
6. HANGER WIRE: MINIMUM 9 GAUGE GALVANIZED STEEL WIRE, FS QQ-W-461 AND ASTM C1063-86.
7. ROD HANGERS: ZINC OR CADMIUM COATED.
D. GENERAL INSTALLATION:
1. ALL METAL FRAMING FOR WALLS, PARTITIONS, BULKHEADS, SUSPENDED CEILINGS AND METAL
FURRING ON MASONRY WALLS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S
PRINTED INSTRUCTIONS, AS SHOWN ON THE DRAWINGS, AND IN ACCORDANCE WITH ASTM
C754-88.
2. ALL METAL FRAMING SHALL BE FULL HEIGHT FROM FLOOR TO FLOOR, OR FLOOR TO ROOF
CONSTRUCTION.
3. FABRICATE AND BEND CROSS FURRING IN SHOP TO REQUIRED RADIUS AND CURVES FOR
ARCHED OR COVED CEILINGS.
4. DO NOT CONTINUE METAL FRAMING, CHANNELS OR FURRING ACROSS CONTROL OR EXPANSION
JOINTS.
5. ATTACH HANGERS TO UNDERSIDE OF CONCRETE DECKING BY MEANS OF POWER ACTUATED
FASTENERS.
6. ATTACH HANGERS TO STEEL MEMBERS BY USE OF MANUFACTURER'S RECOMMENDED CLIPS
OR BY WRAPPING AROUND OR THROUGH THE STEEL MEMBER AND BOLTING, TYING, OR TACK
WELDING HANGER TO ITSELF.
09 3000 - TILING
A. SECTION INCLUDES: TILE FOR FLOOR AND WALL APPLICATIONS, COUNTERS, AND SHOWER
RECEPTORS. CEMENTITIOUS AND COATED GLASS MAT BACKER BOARD AS TILE SUBSTRATE.
CERAMIC ACCESSORIES AND TRIM, AND NON -CERAMIC TRIM.
B. SUBMITTALS: PROVIDE MANUFACTURERS' DATA SHEETS ON TILE, MORTAR, GROUT, AND
ACCESSORIES. INCLUDE INSTRUCTIONS FOR USING GROUTS AND ADHESIVES. SUBMIT SAMPLES OF
ALL TILES IN FULL SIZE TO ILLUSTRATE THE PATTERNS AND COLOR VARIATIONS.
C. DELIVERY, STORAGE, AND HANDLING: PROTECT ADHESIVES FROM FREEZING OR OVERHEATING IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
D. FIELD CONDITIONS: DO NOT INSTALL ADHESIVES IN AN UNVENTILATED ENVIRONMENT. MAINTAIN
AMBIENT AND SUBSTRATE TEMPERATURE OF 50 DEGREES F DURING INSTALLATION OF MORTAR
MATERIALS.
E. TILE: ALL PRODUCTS TO BE BY THE SAME MANUFACTURER. ACCEPTABLE MANUFACTURERS ARE AS
FOLLOWS: AMERICAN OLEAN, DAL -TILE CORPORATION, SUMMITVILLE TILES, INC. OR APPROVED
EQUAL.
1. CERAMIC OR GLASS MOSAIC TILE: 1" X 1" WITH SQUARE EDGES AND AN UNGLAZED SURFACE
FINISH IN COLORS AS SCHEDULED. ANSI A137.1, AND WITH A MOISTURE ABSORPTION RATE OF 0
TO 0.5 PERCENT.
2. GLAZED WALL TILE: 3" X 6" SUBWAY TILE WITH CUSHIONED EDGES AND A HIGH GLOSS
SURFACE FINISH, IN COLORS AS SCHEDULED. ANSI A137.1, WITH A MOISTURE ABSORPTION
RATE OF 3.0 TO 7.0 PERCENT. INSTALL IN THE PATTERN AS INDICATED IN CONSTRUCTION
DOCUMENTS.
F. TRIM AND ACCESSORIES:
1. CERAMIC ACCESSORIES: GLAZED FINISH, SAME COLOR AND FINISH AS ADJACENT FIELD TILE;
SAME MANUFACTURER AS TILE.
2. CERAMIC TRIM: MATCHING BULLNOSE, DOUBLE BULLNOSE, COVE BASE, AND COVE CERAMIC
SHAPES IN SIZES COORDINATED WITH FIELD TILE. TO BE USED IN THE FOLLOWING LOCATIONS:
a. OPEN EDGES: BULLNOSE.
b. INSIDE CORNERS: JOINTED.
C. FLOOR TO WALL JOINTS: COVE BASE.
3. NON -CERAMIC TRIM: SATIN BRASS ANODIZED EXTRUDED ALUMINUM, STYLE AND DIMENSIONS
TO SUIT APPLICATION, FOR SETTING USING TILE MORTAR OR ADHESIVE. AS MANUFACTURED
BY SCHLUTER-SYSTEMS OR APPROVED EQUAL.
G. ADHESIVE MATERIALS: AS MANUFACTURED BY BONSAL AMERICAN, INC., BOSTIK INC., MAPEI
CORPORATION OR APPROVED EQUAL.
1. EPDXY ADHESIVE: ANSI A118.3, THINSET BOND TYPE.
2. TILE SETTING ADHESIVE: ELASTOMERIC, WATERPROOF, LIQUID APPLIED.
H. MORTAR MATERIALS: AS MANUFACTURED BY BONSAL AMERICAN, INC., BOSTIK INC., CUSTOM
BUILDING PRODUCTS OR APPROVED EQUAL.
1. MORTAR BED MATERIALS: PORTLAND CEMENT, SAND, LATEX ADDITIVE AND WATER.
2. MORTAR BOND COAT MATERIALS: DRY -SET PORTLAND CEMENT TYPE: ANSI A118.1.
LATEX-PORTLAND CEMENT TYPE: ANSI A118.4.
I. GROUT MATERIALS: AS MANUFACTURED BY BONSAL AMERICAN, INC., BOSTIK INC., OR APPROVED
EQUAL IN COLORS AS SELECTED BY THE ARCHITECT.
1. STANDARD GROUT: ANY TYPE SPECIFIED IN ANSI A118.6 OR A118.7.
2. EPDXY GROUT: ANSI A118.8, MODIFIED EPDXY EMULSION GROUT.
J. ACCESSORY MATERIALS:
1. CLEAVAGE MEMBRANE: 4 MIL THICK POLYETHYLENE FILM.
2. UNCOUPLING MEMBRANE: 1/8 INCH THICK POLYURETHANE MATTING WITH THREE-DIMENSIONAL
GRID STRUCTURE WITH DOVETAIL SHAPED CAVITIES AND FLEECE WEBBING LAMINATED TO THE
UNDERSIDE TO PROVIDE A MECHANICAL BOND TO THE SUBSTRATE ADHESIVE. PRODUCT TO BE
SCHLUTER SYSTEMS "DITRA." OR APPROVED EQUAL.
3. WATERPROOFING MEMBRANE AT FLOORS: AS SPECIFIED ELSEWHERE.
4. MEMBRANE AT WALLS: 4 MIL THICK POLYETHYLENE FILM.
5. REINFORCING MESH: 2 X 2 INCH SIZE WEAVE OF 16/16 WIRE SIZE; WELDED FABRIC,
GALVANIZED.
6. METAL LATH: ASTM C 847, FLAT DIAMOND MESH, OF WEIGHT TO SUIT APPLICATION,
GALVANIZED FINISH.
7. CEMENTITIOUS BACKER BOARD: ANSI A118.9; HIGH DENSITY, CEMENTITIOUS, GLASS FIBER
REINFORCED, 1/2 INCH THICK; 2 INCH WIDE COATED GLASS FIBER TAPE FOR JOINTS AND
CORNERS.
8. COATED GLASS MAT BACKER BOARD: ASTM C 1178/C 1178M, WITH COATED INORGANIC
FIBERGLASS MAT ON BOTH SURFACES AND INTEGRAL ACRYLIC COATING VAPOR RETARDER.
9. MESH TAPE: 2-INCH WIDE SELF-ADHESIVE FIBERGLASS MESH TAPE.
K. EXAMINATION: VERIFY THAT SUB -FLOOR, AND WALL, SURFACES ARE SMOOTH AND FLAT WITHIN THE
TOLERANCES SPECIFIED, DUST FREE, AND ARE READY TO RECEIVE TILE. VERIFY THAT CONCRETE
SUB -FLOOR SURFACES ARE READY FOR TILE INSTALLATION BY TESTING FOR MOISTURE EMISSION
RATE AND ALKALINITY; CONSULT MANUFACTURER IF THE TEST RESULTS ARE NOT WITHIN
RECOMMENDED LIMITS.
09 3000 - TILING (CONT.)
L. PREPARATION:
1. PROTECT SURROUNDING WORK FROM DAMAGE.
2. VACUUM CLEAN SURFACES AND DAMP CLEAN.
3. SEAL SUBSTRATE SURFACE CRACKS WITH FILLER. LEVEL EXISTING SUBSTRATE SURFACES TO
ACCEPTABLE FLATNESS TOLERANCES.
4. INSTALL CEMENTITIOUS BACKER BOARD IN ACCORDANCE WITH ANSI A108.11 AND BOARD
MANUFACTURER'S INSTRUCTIONS. TAPE JOINTS AND CORNERS, COVER WITH SKIM COAT OF
DRY -SET MORTAR TO A FEATHER EDGE.
5. INSTALL TILE BACKER BOARD IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS,
USING GALVANIZED ROOFING NAILS OR CORROSION -RESISTANT BUGLE HEAD DRYWALL
SCREWS. BED FIBERGLASS SELF-ADHESIVE TAPE AT ALL JOINTS AND CORNERS WITH MATERIAL
USED TO SET TILES.
M. INSTALLATION - GENERAL:
1. INSTALL TILE, THRESHOLDS, AND STAIR TREADS AND GROUT IN ACCORDANCE WITH
APPLICABLE REQUIREMENTS OF ANSI A108.1 THROUGH A108.13, MANUFACTURER'S
INSTRUCTIONS, AND TCA HANDBOOK RECOMMENDATIONS.
2. LAY TILE TO PATTERN INDICATED. DO NOT INTERRUPT TILE PATTERN THROUGH OPENINGS.
3. CUT AND FIT TILE TO PENETRATIONS THROUGH TILE, LEAVING SEALANT JOINT SPACE. FORM
CORNERS AND BASES NEATLY. ALIGN FLOOR JOINTS.
4. PLACE TILE JOINTS UNIFORM IN WIDTH, SUBJECT TO VARIANCE IN TOLERANCE ALLOWED IN TILE
SIZE. MAKE JOINTS WATERTIGHT, WITHOUT VOIDS, CRACKS, EXCESS MORTAR, OR EXCESS
GROUT.
5. FORM INTERNAL ANGLES SQUARE AND EXTERNAL ANGLES BULLNOSED.
6. INSTALL CERAMIC ACCESSORIES RIGIDLY IN PREPARED OPENINGS.
7. INSTALL NON -CERAMIC TRIM IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
8. SOUND TILE AFTER SETTING. REPLACE HOLLOW SOUNDING UNITS.
9. KEEP EXPANSION JOINTS FREE OF ADHESIVE OR GROUT. APPLY SEALANT TO JOINTS.
10. ALLOW TILE TO SET FOR A MINIMUM OF 48 HOURS PRIOR TO GROUTING.
11. GROUT TILE JOINTS. USE STANDARD GROUT.
12. APPLY SEALANT TO JUNCTION OF TILE AND DISSIMILAR MATERIALS AND JUNCTION OF
DISSIMILAR PLANES.
N. INSTALLATION - FLOORS - THIN -SET METHODS:
1. OVER EXTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA HANDBOOK
METHOD F102, WITH STANDARD GROUT.
2. OVER INTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA HANDBOOK
METHOD F113, DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT, WITH STANDARD GROUT.
3. USE UNCOUPLING MEMBRANE UNDER ALL TILE.
4. OVER WOOD SUBSTRATE WITH BACKER BOARD UNDERLAYMENT, INSTALL IN ACCORDANCE
WITH TCA HANDBOOK METHOD F144, FOR CEMENTITIOUS BACKER BOARDS, WITH STANDARD
GROUT.
0. INSTALLATION - FLOORS - MORTAR BED METHODS:
1. OVER EXTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA F101, BONDED,
WITH STANDARD GROUT.
2. OVER INTERIOR CONCRETE SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA HANDBOOK
METHOD F111, WITH CLEAVAGE MEMBRANE.
3. WHERE WATERPROOFING MEMBRANE IS INDICATED, WITH STANDARD GROUT OR NO MENTION
OF GROUT TYPE, INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD F121.
4. OVER WOOD SUBSTRATES, INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD F141, WITH
STANDARD GROUT.
5. CLEAVAGE MEMBRANE: LAP EDGES AND ENDS.
6. WATERPROOFING MEMBRANE: INSTALL AS SPECIFIED IN ANSI A108.13.
7. MORTAR BED THICKNESS: 5/8 INCH.
P. INSTALLATION - SHOWERS AND BATHTUB WALLS:
1. AT BATHTUB WALLS INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD B412, OVER
CEMENTITIOUS BACKER UNITS WITH WATERPROOFING MEMBRANE.
2. GROUT WITH STANDARD GROUT AS SPECIFIED ABOVE.
3. SEAL JOINTS BETWEEN TILE WORK AND OTHER WORK WITH SEALANT AS SPECIFIED
ELSEWHERE.
Q. INSTALLATION - WALL TILE:
1. OVER CEMENTITIOUS BACKER UNITS ON STUDS, INSTALL IN ACCORDANCE WITH TCA
HANDBOOK METHOD W244, USING MEMBRANE AT TOILET ROOMS.
2. OVER COATED GLASS MAT BACKER BOARD ON STUDS, INSTALL IN ACCORDANCE WITH TCA
HANDBOOK METHOD W245.
3. OVER GYPSUM WALLBOARD ON WOOD OR METAL STUDS INSTALL IN ACCORDANCE WITH TCA
HANDBOOK METHOD W243, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT.
4. WHERE MORTAR BED IS INDICATED, INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD
W222, ONE COAT METHOD.
5. WHERE WATERPROOFING MEMBRANE IS INDICATED OTHER THAN AT SHOWERS AND BATHTUB
WALLS, INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD W222, ONE COAT METHOD.
6. OVER INTERIOR CONCRETE AND MASONRY INSTALL IN ACCORDANCE WITH TCA HANDBOOK
METHOD W202, THIN -SET WITH DRY -SET OR LATEX-PORTLAND CEMENT BOND COAT.
7. OVER WOOD STUDS WITHOUT BACKER INSTALL IN ACCORDANCE WITH TCA HANDBOOK METHOD
W231 MORTAR BED WITH MEMBRANE WHERE INDICATED.
8. OVER METAL STUDS WITHOUT BACKER INSTALL IN ACCORDANCE WITH TCA HANDBOOK
METHOD W241 MORTAR BED WITH MEMBRANE WHERE INDICATED.
R. CLEANING: CLEAN TILE AND GROUT SURFACES.
S. PROTECTION: DO NOT PERMIT TRAFFIC OVER FINISHED FLOOR SURFACE FOR 4 DAYS AFTER
INSTALLATION.
09 5100 - ACOUSTIC CEILINGS
A. SECTION INCLUDES: SUSPENDED METAL GRID CEILING SYSTEM AND ACOUSTICAL UNITS.
B. SUBMITTALS: PROVIDE PRODUCT DATA ON SUSPENSION SYSTEM COMPONENTS. SUBMIT TWO
SAMPLES 4X4 INCH IN SIZE ILLUSTRATING MATERIAL AND FINISH OF ACOUSTICAL UNITS.
C. FIELD CONDITIONS: MAINTAIN UNIFORM TEMPERATURE OF MINIMUM 60 DEGREES F, AND MAXIMUM
HUMIDITY OF 40 PERCENT PRIOR TO, DURING, AND AFTER ACOUSTICAL UNIT INSTALLATION.
D. ACOUSTICAL UNITS:
1. ACCEPTABLE MANUFACTURERS INCLUDE: ARMSTRONG WORLD INDUSTRIES, INC.,
CERTAINTEED CORPORATION, USG OR APPROVED EQUAL.
2. ACOUSTICAL UNITS - GENERAL: ASTM E 1264, CLASS A.
3. UNITS FOR INSTALLATION IN FIRE -RATED SUSPENSION SYSTEM: LISTED AND CLASSIFIED FOR
THE FIRE -RESISTIVE ASSEMBLY THE SUSPENSION SYSTEM IS A PART OF.
4. METAL -FACED ACOUSTICAL PANELS: GALVANIZED STEEL FLAT FORMED SHEET, WITH GLASS
FIBER ACOUSTICAL MEDIA BACKING; SQUARE EDGED 24" X 24" WHITE PERFORATED PANELS
WITH A CEILING ATTENUATION CLASS (CAC) AS SPECIFIED IN ASTM E 1264.
5. SUSPENSION SYSTEM: EXPOSED GRID.
6. ACOUSTICAL PANELS #1: 5/8" X 2' X 4"'RADAR CLIMAPLUS", LAY -IN MINERAL FIBER BOARD UNITS
WITH SQUARE EDGE AS MANUFACTURED BY USG. PANELS SHALL BE WHITE WITH A
NON -DIRECTIONAL PATTERN.
7. ACOUSTICAL PANEL #2: 3/4" X 2' X 4"'ECLIPSE CLIMAPLUS ILLUSION TWO/24", LAY -IN MINERAL
FIBER BOARD UNITS WITH SILT BEVELED EDGE AS MANUFACTURED BY USG. PANELS SHALL BE
WHITE, WITH A NON -DIRECTIONAL PATTERN.
8. ACOUSTICAL PANEL #3: 3/4" X 2' X 2"'MARS CLIMAPLUS", ITEM #86985, LAY -IN MINERAL FIBER
BOARD UNITS WITH FLB BEVELED EDGE AS MANUFACTURED BY USG. PANELS SHALL BE WHITE
WITH A NON -DIRECTIONAL PATTERN.
9. ACOUSTICAL PANEL #4:1/2" X 2' X 4-SHEETROCK LAY -IN CEILING PANEL CLIMAPLUS", LAY -IN
GYPSUM CORE UNITS WRAPPED WITH VINYL WITH SO SQUARE EDGE RESTING ON FLANGES OF
EXPOSED GRID SYSTEM, AS MANUFACTURED BY USG. PANELS SHALL BE WHITE IN COLOR, AND
BE ANTIMICROBIAL, ANTI -ODOR, LOW VOC. THE PANELS MUST CONFORM TO US DEPARTMENT
OF AGRICULTURE FOOD SAFETY INSPECTION SERVICE REQUIREMENTS FOR FOOD PROCESSING
AREAS AND WET LOCATIONS.
E. SUSPENSION SYSTEM(S):
1. ACCEPTABLE MANUFACTURERS INCLUDE: ARMSTRONG WORLD INDUSTRIES, INC.,
CERTAINTEED CORPORATION, CHICAGO METALLIC CORPORATION, USG OR APPROVED EQUAL.
2. SUSPENSION SYSTEMS - GENERAL: ASTM C 635; DIE CUT AND INTERLOCKING COMPONENTS,
WITH STABILIZER BARS, CLIPS, SPLICES, PERIMETER MOLDINGS, AND HOLD DOWN CLIPS AS
REQUIRED.
3. SUSPENSION SYSTEM #1 & #2: 2 X 4 GRID SUSPENSION SYSTEM "DONN DX" AS MANUFACTURED
BY USG. PROVIDE FIRE -RATED SUSPENSION SYSTEM WHERE NOTED ON DRAWINGS. DIRECT
HUNG, STANDARD 15/16" WIDE FACE TEE EXPOSED STEEL GRID, LO-GLOSS WHITE FINISH, WITH
DOUBLE WEB CONSTRUCTION. THE MAIN RUNNERS SHALL CONFORM TO THE HEAVY-DUTY
CLASSIFICATION OF ASTM C635.
09 5100 - ACOUSTIC CEILINGS (CONT.)
4. SUSPENSION SYSTEM #3: 2 X 2 GRID SUSPENSION SYSTEM: "DONN FINELINE 1/8 DXFF" SYSTEM
AS MANUFACTURED BY USG. PROVIDE FIRE -RATED SUSPENSION SYSTEM WHERE NOTED ON
DRAWINGS. DIRECT HUNG, STANDARD 9/16" WIDE FACE TEE EXPOSED STEEL GRID, LO-GLOSS
WHITE FINISH, WITH DOUBLE WEB CONSTRUCTION. THE MAIN RUNNERS SHALL CONFORM TO
THE HEAVY-DUTY CLASSIFICATION OF ASTM C635.
5. SUSPENSION SYSTEM #4: 2 X 4 GRID SUSPENSION SYSTEM: "DONN DXLA" SYSTEM AS
MANUFACTURED BY USG. DIRECT HUNG, STANDARD 15/16" WIDE FACE TEE EXPOSED STEEL
GRID, LO-GLOSS WHITE FINISH, WITH DOUBLE WEB CONSTRUCTION. THE MAIN RUNNERS SHALL
CONFORM TO THE HEAVY-DUTY CLASSIFICATION OF ASTM C635. THE SYSTEM MUST CONFORM
TO US DEPARTMENT OF AGRICULTURE FOOD SAFETY INSPECTION SERVICE REQUIREMENTS
FOR FOOD PROCESSING AREAS AND WET LOCATIONS.
F. ACCESSORIES:
1. SUPPORT CHANNELS AND HANGERS: GALVANIZED STEEL; SIZE AND TYPE TO SUIT
APPLICATION, SEISMIC REQUIREMENTS, AND CEILING SYSTEM FLATNESS REQUIREMENT
SPECIFIED.
2. PERIMETER MOLDINGS: SAME MATERIAL AND FINISH AS GRID.
3. AT EXPOSED GRID: PROVIDE L-SHAPED MOLDING FOR MOUNTING AT SAME ELEVATION AS FACE
OF GRID.
4. GYPSUM BOARD: FIRE RATED TYPE; 5/8 INCH THICK, ENDS AND EDGES SQUARE, PAPER FACED.
5. GASKET FOR PERIMETER MOLDINGS: CLOSED CELL RUBBER SPONGE TAPE.
6. TOUCH-UP PAINT: TYPE AND COLOR TO MATCH ACOUSTICAL AND GRID UNITS.
G. INSTALLATION - SUSPENSION SYSTEM:
1. INSTALL SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C 636, ASTM E 580, AND
MANUFACTURER'S INSTRUCTIONS AND AS SUPPLEMENTED IN THIS SECTION.
2. RIGIDLY SECURE SYSTEM, INCLUDING INTEGRAL MECHANICAL AND ELECTRICAL COMPONENTS,
FOR MAXIMUM DEFLECTION OF 1:360.
3. LOCATE SYSTEM ON ROOM AXIS ACCORDING TO REFLECTED CEILING PLANS.
4. PROVIDE HANGER CLIPS DURING STEEL DECK ERECTION. PROVIDE ADDITIONAL HANGERS AND
INSERTS AS REQUIRED.
5. HANG SUSPENSION SYSTEM INDEPENDENT OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT
6. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS,
REINFORCE THE NEAREST AFFECTED HANGERS AND RELATED CARRYING CHANNELS TO SPAN
THE EXTRA DISTANCE.
7. DO NOT SUPPORT COMPONENTS ON MAIN RUNNERS OR CROSS RUNNERS IF WEIGHT EXCEEDS
THE TOTAL DEAD LOAD DEFLECTION CAPABILITY.
8. SUPPORT FIXTURE LOADS USING SUPPLEMENTARY HANGERS, OR SUPPORT COMPONENTS
INDEPENDENTLY.
9. PERIMETER MOLDING: INSTALL AT INTERSECTION OF CEILING AND VERTICAL SURFACES AND
AT JUNCTIONS WITH OTHER INTERRUPTIONS. USE THE LONGEST PRACTICAL LENGTHS AND
OVERLAP AND RIVET CORNERS.
H. INSTALLATION -ACOUSTICAL UNITS:
1. INSTALL ACOUSTICAL UNITS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
2. FIT ACOUSTICAL UNITS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER DEFECTS
DETRIMENTAL TO APPEARANCE AND FUNCTION.
3. FIT BORDER TRIM NEATLY AGAINST ABUTTING SURFACES.
4. INSTALL ACOUSTICAL UNITS LEVEL, IN UNIFORM PLANE, AND FREE FROM TWIST, WARP, AND
DENTS.
5. CUTTING ACOUSTICAL UNITS: MAKE FIELD CUT EDGES OF SAME PROFILE AS FACTORY EDGES.
6. INSTALL HOLD-DOWN CLIPS ON EACH PANEL TO RETAIN PANELS TIGHT TO GRID SYSTEM;
COMPLY WITH FIRE RATING REQUIREMENTS. INSTALL HOLD-DOWN CLIPS ON PANELS WITHIN 20
FT OF AN EXTERIOR DOOR.
I. TOLERANCES: MAXIMUM VARIATION FROM FLAT AND LEVEL SURFACE SHALL BE 1/8" IN 10 FEET. THE
MAXIMUM VARIATION FROM PLUMB OF GRID MEMBERS SHALL BE 2 DEGREES.
09 6500 - RESILIENT FLOORING
A. SECTION INCLUDES: RESILIENT SHEET AND TILE FLOORING, RESILIENT BASE, RESILIENT STAIR
ACCESSORIES AND INSTALLATION ACCESSORIES.
B. SUBMITTALS: PROVIDE PRODUCT DATA DESCRIBING PHYSICAL AND PERFORMANCE
CHARACTERISTICS; INCLUDING SIZES, PATTERNS AND COLORS AVAILABLE; AND INSTALLATION
INSTRUCTIONS. SUBMIT TWO SAMPLES, 4"X4" IN SIZE ILLUSTRATING COLOR AND PATTERN FOR EACH
RESILIENT FLOORING PRODUCT SPECIFIED.
C. DELIVERY, STORAGE, AND HANDLING: PROTECT ROLL MATERIALS FROM DAMAGE BY STORING ON
END.
D. FIELD CONDITIONS: MAINTAIN TEMPERATURE IN STORAGE AREA BETWEEN 55 DEGREES F AND 90
DEGREES F. STORE MATERIALS FOR NOT LESS THAN 48 HOURS PRIOR TO INSTALLATION AT A
TEMPERATURE OF 70 DEGREES F. THEREAFTER, MAINTAIN CONDITIONS ABOVE 55 DEGREES F.
F. TILE FLOORING:
1. VINYL COMPOSITION TILE: HOMOGENEOUS WITH COLOR EXTENDING THROUGHOUT
THICKNESS OF TILE. SHALL COMPLY WITH ASTM F 1066, OF CLASS CORRESPONDING TO TYPE
SPECIFIED.
a. TILE SIZE: 12" X 12", 0.125" THICK.
b. COLOR AND PATTERN: AS SELECTED BY ARCHITECT FROM MANUFACTURE'S STANDARD
SELECTIONS.
c. MANUFACTURERS: ARMSTRONG WORLD INDUSTRIES, INC., CONGOLEUM VCT BY
MOHAWK GROUP, COMMERCIAL VCT, AZROCK BY TARKETT INC., KENTILE, MANNINGTON
OR APPROVED EQUAL.
d. ADHESIVE: AS RECOMMENDED FOR USE BY THE TIEL MANUFACTURER.
2. RUBBER TILE: HOMOGENEOUS COLOR AND PATTERN THROUGHOUT THICKNESS OF TILE.
SHALL COMPLY WITH ASTM F 1344, OF CLASS 1.
a. TILE SIZE: 0.080" THICK BY 12"X12", 19 11/16" X 19 11/16" OR 36"X36".
b. COLOR AND PATTERN: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD
SELECTIONS.
c. MANUFACTURERS: ROPPE CORP., "SAFETCORK", JOHNSONITE, VPI, BURKE FLOORING OR
APPROVED EQUAL.
d. ADHESIVE: ROPPE CORP., "375 RUBBER AND VINYL TILE ADHESIVE", OR APPROVED EQUAL.
3. LINOLEUM TILE: HOMOGENEOUS WEAR LAYER BONDED TO BACKING, WITH COLOR AND
PATTERN THROUGH WEAR LAYER THICKNESS. SHALL COMPLY WITH ASTM F 2195, TYPE
CORRESPONDING TO TYPE SPECIFIED.
a. TLIE SIZE: 13"X13" OR 20"X20" AS INDICATED ON THE DRAWINGS.
b. BACKING: POLYESTER.
c. WEAR LAYER THICKNESS: 0.098 INCH, MINIMUM, EXCLUDING BACKING.
d. COLOR: TO BE SELECTED FROM MANUFACTURER'S FULL COLOR RANGE.
e. MANUFACTURERS: MARMOLEUM BY FORBID FLOORING SYSTEMS, TARKETT INC. OR
APPROVED EQUAL.
H. RESILIENT BASE: ASTM F 1861, TYPE TS RUBBER, VULCANIZED THERMOSET; TOP SET STYLE B, COVE
BASE 1/8" THICK AND 6" IN HEIGHT.
1. COLOR: AS SELECTED FROM MANUFACTURER'S STANDARDS.
2. ACCESSORIES: PRE -MOLDED EXTERNAL CORNERS AND END STOPS.
3. MANUFACTURERS: JOHNSONITE, INC., ROPPE CORP., VPI OR APPROVED EQUAL.
I. ACCESSORIES:
1. SUBFLOOR FILLER: WHITE PREMIX LATEX; TYPE RECOMMENDED BY ADHESIVE MATERIAL
MANUFACTURER.
2. PRIMERS, ADHESIVES, AND SEAMING MATERIALS: WATERPROOF; TYPES RECOMMENDED BY
FLOORING MANUFACTURER.
3. MOLDINGS AND EDGE STRIPS: SAME MATERIAL AS FLOORING.
4. FILLER FOR COVED BASE: PLASTIC.
5. SEALER AND WAX: TYPES RECOMMENDED BY FLOORING MANUFACTURER.
J. EXAMINATION: VERIFY THAT SURFACES ARE FLAT TO TOLERANCES ACCEPTABLE TO FLOORING
MANUFACTURER, FREE OF CRACKS, CLEAN, DRY, AND FREE OF CURING COMPOUNDS, SURFACE
HARDENERS, AND OTHER CHEMICALS THAT MIGHT INTERFERE WITH BONDING OF FLOORING TO
SUBSTRATE. VERIFY THAT CONCRETE SUB -FLOOR SURFACES ARE DRY ENOUGH AND READY FOR
INSTALLATION BY TESTING FOR MOISTURE EMISSION RATE AND ALKALINITY IN ACCORDANCE WITH
ASTM F 710. CONTACT MANUFACTURER IF TEST RESULTS ARE NOT WITHIN RECOMMENDED LIMITS.
CERTIFIED BY:
,� <<$' ,i
R'
. 'ems �o' :�a
No. _
= 0 900019 0 =
STATE OF
iN� Np.
.e I A
i
i
Lu
W o N
0�aac)
p 0 cD
LL V Nt
z W
Q O < >-
H -
� z z z=
C)J Q oz
D D W c) 3:
z
(D
0 �
j< v Z _ J >_
-
Q
z Q 2J
QU
O ce � J =
U W
3: LU z 2E
w
z J �
J 00
cy) U
2
DRAWING
ARCHITECTURAL
SPECIFICATIONS
ISSUE
100% CONST. DOCUMENTS - 05/15/2020
90% CONST. DOCUMENTS - 04/01/2020
DESIGN DEVELOPMENT SET-01/16/2020
r___ - �
REVISIONS
Al -
2 -
3 -
4 -
PROJECT NUMBER 1832
DATE MAY 15, 2020