Loading...
HomeMy WebLinkAboutA0.5am Z am cn a) _ 2 ry Lm 2 U N L U < a co U) co = 0 N O N 09 6500 - RESILIENT FLOORING (CONT.) K. PREPARATION: REMOVE EXISTING RESILIENT FLOORING AND FLOORING ADHESIVES. PREPARE SUB -FLOOR SURFACES AS RECOMMENDED BY FLOORING AND ADHESIVE MANUFACTURERS. REMOVE SUB -FLOOR RIDGES AND BUMPS. FILL MINOR LOW SPOTS, CRACKS, JOINTS, HOLES, AND OTHER DEFECTS WITH SUB -FLOOR FILLER TO ACHIEVE SMOOTH, FLAT, HARD SURFACE. L. INSTALLATION: 1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. SPREAD ONLY ENOUGH ADHESIVE TO PERMIT INSTALLATION OF MATERIALS BEFORE INITIAL SET. 3. FIT JOINTS TIGHTLY WHILE SETTING FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ATTAIN FULL ADHESION. 4. WHERE TYPES OF FLOOR FINISH, DIFFERENT ON OPPOSITE SIDES OF DOOR, TERMINATE FLOORING UNDER CENTERLINE OF DOOR. 5. INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES, AND WHERE FLOORING TERMINATES. 6. SCRIBE FLOORING TO WALLS, COLUMNS, CABINETS, FLOOR OUTLETS, AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS. M. TILE FLOORING INSTALLATION: MIX TILE FROM CONTAINER TO ENSURE SHADE VARIATIONS ARE CONSISTENT WHEN TILE IS PLACED. LAY FLOORING WITH JOINTS AND SEAMS PARALLEL TO BUILDING LINES TO PRODUCE SYMMETRICAL TILE PATTERN. INSTALL TILE TO DESIGNED PATTERN AS SHOWN IN DRAWINGS. ALLOW MINIMUM 1/2 SIZE TILE WIDTH AT ROOM PERIMETER. N. RESILIENT BASE INSTALLATION: FIT JOINTS TIGHTLY AND MAKE VERTICAL. MAINTAIN MINIMUM DIMENSION OF 18 INCHES BETWEEN JOINTS. INSTALL BASE ON SOLID BACKING. BOND TIGHTLY TO WALL AND FLOOR SURFACES. 0. CLEANING AND POLISHING: REPLACE DAMAGED OR OTHERWISE DEFECTIVE TILE PRIOR TO FINAL INSPECTION, AND BEFORE MAINTENANCE MATERIALS ARE USED. CLEAN FLOORS AS APPROVED BY MANUFACTURER. RINSE FLOORS AND ALLOW DRYING THOROUGHLY. APPLY ONE (1) COAT OF SYNTHETIC TYPE, WATER EMULSION, SELF -POLISHING, MEDIUM GLOSS POLISH, SIMILAR TO ARMSTRONG'S VINAFLOS. CLEANING AND POLISHING SHALL RESULT IN ABSENCE OF SOIL, DUST, SCUFF MARKS, SCRAPES, EXCESSIVE ADHESIVE, AND OTHER BLEMISHES. SECTION 09 9100 - PAINTING A. SECTION INCLUDES: PAINTING, FINISHING AND DECORATING WORK AS SHOWN AND SPECIFIED OF ALL NORMALLY FINISHED SURFACES THROUGHOUT INTERIOR AND EXTERIOR OF BUILDING EXCEPT WHEN OTHERWISE INDICATED. PAINTING INCLUDES THE FINISHING OF MECHANICAL AND ELECTRICAL WORK, INCLUDING EXTERIOR UNITS AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS. COPPER, BRONZE, CHROMIUM PLATE, NICKEL, STAINLESS STEEL, ALUMINUM, LEAD AND LEAD COATED COPPER SHALL NOT BE PAINTED OR FINISHED. B. SUBMITTALS: SUBMIT MANUFACTURER'S TECHNICAL LITERATURE, SPECIFICATIONS AND INSTALLATION INSTRUCTIONS THAT INCLUDE WET AND DRY FILM THICKNESS, VOLUME SOLIDS PERCENTAGE AND ANY OTHER PERTINENT INFORMATION. C. DELIVERY AND STORAGE: DELIVER MATERIALS TO SITE IN MANUFACTURER'S UNBROKEN, SEALED CONTAINERS, BEARING ORIGINAL LABELS. STORE MATERIALS IN SINGLE PLACE AS APPROVED. TAKE ALL NECESSARY PRECAUTIONS TO AVOID DANGER OF FIRE. REMOVE SOILED OR USED RAGS, WASTE AND TRASH EACH NIGHT UNLESS STORED IN CLOSED METAL CONTAINERS. KEEP PAINT AND SOLVENTS SEALED IN CLOSED METAL CONTAINERS. D. PROTECTION AND CLEAN-UP: PROTECT WORK OF OTHER TRADES AGAINST DAMAGE, INJURY, OR SOILING FROM MATERIALS, TOOLS OR UTENSILS USED. AT COMPLETION OF WORK REMOVE PAINT WHERE IT HAS BEEN SPILLED OR SPLATTERED ON SURFACES, INCLUDING FIXTURES, GLASS, FURNITURE, FITTINGS, HARDWARE, ETC. REMOVE WITHOUT MARRING FINISH OF ITEM BEING CLEANED. E. ACCEPTABLE MANUFACTURERS: SHERWIN WILLIAMS BENJAMIN MOORE DEVOE PAINT MAB DURON PORTER PAINT CO., PRATT & LAMBERT OR APPROVED EQUAL. F. MATERIALS: 1. ALL COLORS TO BE SELECTED BY ARCHITECT. 2. MATERIALS SHALL BE EXACTLY AS SCHEDULED IN BRAND AND QUALITY. 3. MATERIALS SHALL BE FIRST LINE PRODUCTS OF THE APPROVED MANUFACTURERS. 4. UNSPECIFIED BRANDS OF MATERIALS SUCH AS SHELLAC, LINSEED OIL, TURPENTINE OR THINNERS SHALL BE PURE, HIGHEST QUALITY, BEAR IDENTIFYING LABEL ON CONTAINER, AS APPROVED. 5. MIXING AND TINTING SHALL BE IN STRICT ACCORD WITH MANUFACTURER'S DIRECTIONS. IF REQUIRED, PREPARE 3 PANELS FOR FINISH AND COLOR, IN ADVANCE, FOR APPROVAL. G. SURFACE PREPARATION: 1. SURFACES SHALL BE CLEAN, FREE OF DIRT, GREASE AND ANY FOREIGN MATTER THAT WOULD ADVERSELY AFFECT FINISHED APPEARANCE OR PROTECTIVE PROPERTIES OF PAINT APPLIED. FACTORY PRIMED SURFACES SHALL BE DETERMINED PAINTABLE IN A NORMAL MANNER OR TREATED PROPERLY TO SECURE ADEQUATE ADHESION. 2. GYPSUM BOARD: FILL MINOR IRREGULARITIES WITH SPACKLING COMPOUND, SAND TO SMOOTH, LEVEL SURFACE. EXERCISE CARE TO AVOID RAISING NAP OF PAPER. 3. WOOD: SANDPAPER TO SMOOTH AND EVEN SURFACE AND DUST OFF. TOUCH UP KNOTS, PITCH STREAKS AND SAPPY SPOTS WITH SHELLAC OR KNOT SEALER. PUTTY OR FILL NAIL HOLES, OTHER CRACKS OR DEFECTS, AFTER PRIME COAT. PUTTY SHALL MATCH COLOR OF WOOD, SAND SMOOTH. 4. METALS: REMOVE DIRT, GREASE AND OIL WITH XYLOL. REMOVE RUST, MILL SCALE AND DEFECTIVE PAINT DOWN TO SOUND SURFACE, USING SCRAPER, SANDPAPER, OR WIRE BRUSH AS APPROPRIATE. GRIND, IF NECESSARY, TO REMOVE SHOULDERS AT EDGE OF SOUND PAINT TO PREVENT FLAWS FROM PHOTOGRAPHING THROUGH FINISH COATS. 5. WOOD DOORS: COMPLY WITH AWI AND NWWDA a. JUST PRIOR TO FINISHING, COMPLETELY BLOCK SAND DOORS IN HORIZONTAL POSITION, USING NOT LESS THAN 150 GRIT SANDPAPER, REMOVE HANDLING MARKS AND RAISED GRAIN. b. PAINT TOP, BOTTOM, OPENING AND HARDWARE RECESS EDGE AS SOON AS POSSIBLE. H. MOISTURE AND TEMPERATURE: 1. DO NOT PAINT WHEN AIR TEMPERATURE IS BELOW 50 DEGREES F OR ABOVE 100 DEGREES F OR WHEN THE TEMPERATURE OF THE SURFACE TO BE COATED IS BELOW 50 DEGREES F. DO NOT PAINT EXTERIOR SURFACES WHEN THE RELATIVE HUMIDITY MEETS OR EXCEEDS 85% AND WHEN THE SURFACE TEMPERATURE IS WITHIN 5 DEGREES F OF THE DEW POINT. ALL PAINT AND COATING MATERIALS SHALL BE STORED UNDER COVER AND AT A TEMPERATURE WITHIN 10 DEGREES F OF ANTICIPATED APPLICATION TEMPERATURE. DO NOT PAINT DAMP SURFACES. 2. PROVIDE VENTILATION DURING PAINTING AND DRYING PERIODS. I. APPLICATION: 1. APPLY FINISHES UNDER CONDITIONS CONDUCIVE TO GOOD RESULTS. HONOR INDIVIDUAL REQUIREMENTS OF EACH MATERIAL USED AS TO DIGESTION TIME, POT LIFE, AND TEMPERATURE AND HUMIDITY LIMITS. 2. APPLY EACH COAT UNIFORMLY WITH SPREADING RATE RECOMMENDED BY MANUFACTURER. 3. EACH SUCCEEDING COAT SHALL BE VISIBLY DIFFERENT FROM PRECEDING COAT. 4. FINAL COAT OF FINISH SHALL GIVE VISUAL EVIDENCE OF SOLID HIDING AND UNIFORM APPEARANCE. THERE SHALL BE NO RUNS, SAGS, CURTAINS OR OTHER EVIDENCE OF POOR APPLICATION. 5. EACH COAT SHALL BE THOROUGHLY DRY BEFORE APPLYING SUCCEEDING COATS, UNLESS SPECIFICALLY EXEMPTED BY MANUFACTURER. 6. EDGES OF FINISH ADJOINING OTHER MATERIALS OR COLOR SHALL BE SHARP AND CLEAN, WITH NO OVERLAPPING. 7. BRUSH APPLICATION: BRUSH OUT EACH COAT UNIFORMLY TO ELIMINATE LAPS, SKIPS AND EXCESS BRUSH MARKS. 8. ROLLER APPLICATION: USE PROPER SKILL TO AVOID LAPPING AND EXCESS PAINT LINES FROM EDGE OF ROLLER. AREAS CUT IN WITH BRUSH SHALL HAVE SAME TEXTURE, COLOR AND HIDING AS ADJACENT AREAS. 9. SPRAY APPLICATION: SPRAY PAINTING SHALL BE DONE PRIOR TO INSTALLATION OF FIXTURES, HARDWARE, FLOORING AND OTHER FINISH ITEMS UNLESS THOROUGHLY PROTECTED. USE SKILLED PAINTERS TO ASSURE UNIFORM FINISH WITH NO EVIDENCE OF POOR OR IMPROPER APPLICATION. 10. SPOT PRIMING TO CORRECT SOILED OR DAMAGED SURFACES WILL BE ALLOWED ONLY WHEN TOUCH-UP SPOT IS BLENDED INTO SURROUNDING FINISH AND IS INVISIBLE TO NORMAL VIEWING. OTHERWISE, RECOATING OF ENTIRE WALL OR AREA WILL BE REQUIRED. 11. FINISH TOP AND BOTTOM OF DOORS WITH TWO COATS OF SAME FINISH AS USED FOR FACES AND EDGES AFTER THEY ARE FITTED. J. MECHANICAL AND ELECTRICAL WORK: PROVIDE FINISH PAINTING FOR EXTERIOR MECHANICAL AND ELECTRICAL WORK. WORK SHALL INCLUDE BUT NOT BE LIMITED TO GRILLES, LOUVERS, PIPING, CONDUIT, SHEET METAL, FRAMES AND COVERS, ACCESS DOORS, AND EQUIPMENT. IN GENERAL AIR CONDENSING UNITS AND METERS WILL BE FACTORY FINISHED. SECTION 09 9100 - PAINTING (CONT.) K. MISCELLANEOUS PAINTING WORK: PROVIDE FINISH PAINTING FOR EXPOSED EXTERIOR STEEL INCLUDING BUT NOT LIMITED TO STEEL COLUMNS, LINTELS, BOLLARDS, GUARDRAILSMANDRAILS, AND GAS LINES. L. PAINTING SCHEDULE: 1. CONCRETE & CMU a. 1ST COAT: S-W LOXON CONCRETE & MASONRY PRIMER, A24W8300 b. 2ND COAT: S-W PROMAR 200 ZERO VOC SEMI -GLOSS, B31 SERIES C. 3RD COAT PROMAR 200 ZERO VOC SEMI -GLOSS, B31 SERIES 2. METAL (ALUMINUM) a. 1ST COAT: PRO INDUSTRIAL PRO-CRYL® UNIVERSAL ACRYLIC PRIMER B66-310 SERIES (2.0 - 4.0 MILS DRY PER COAT) b. 2ND COAT: S-W PRO INDUSTRIAL ACRYLIC, B66-600 SERIES C. 3RD COAT: S-W PRO INDUSTRIAL ACRYLIC, B66-600 3. METAL (GALVANIZED) a. 1ST COAT: S-W PRO INDUSTRIAL PROCRYL UNIVERSAL ACRYLIC PRIMER, B66-310 b. 2ND COAT: S-W PRO INDUSTRIAL ACRYLIC, B66-600 SERIES C. 3RD COAT: S-W PRO INDUSTRIAL ACRYLIC, B66-600 SERIES 4. METAL (INTERIOR PRE -PRIMED FERROUS METAL): STRUCTURAL STEEL TO RECEIVE INTUMESCENT FIRE-RESISTANT COATING - SEE SPECIFICATION SECTION 07816 - INTUMESCENT FIREPROOFING. OTHER, NON -FIRE RATED ELEMENTS SHALL RECEIVE THE FOLLOWING FINISH, INCLUDING PRE -PRIMED HOLLOW METAL DOOR AND WINDOW FRAMES: a. 1ST COAT: S-W PRO INDUSTRIAL PROCRYL UNIVERSAL ACRYLIC PRIMER, B66-310 b. 2ND COAT: S-W PRO INDUSTRIAL ACRYLIC, B66-650 5. METAL (ALL OTHER FERROUS METAL): a. 1ST COATS-W PRO INDUSTRIAL PROCRYL UNIVERSAL ACRYLIC PRIMER, B66-310 b. 2ND COAT: S-W PRO INDUSTRIAL ACRYLIC SEMI -GLOSS COATING, B66- 650SERIES C. 3RD COAT: S-W PRO INDUSTRIAL ACRYLIC SEMI -GLOSS COATING, B66-650 SERIES (4 MILS WET, 1.3 MILS DRY PER COAT) 6. DRYWALL ( TYPICAL ) a. 1ST COAT: S-W PROMAR 2000 ZERO VOC LATEX PRIMER (4 MILS WET, 1.2 MILS DRY) b. 2ND COAT: S-W PROMAR 200 ZERO VOC EGSHEL, B20 SERIES C. 3RD COAT: S-W PROMAR 200 ZERO VOC EGSHEL, B20 SERIES 7. DRYWALL - EPDXY: (RESTROOM WET WALLS) a. 1ST COAT: S-W PROMAR 2000 ZERO VOC LATEX PRIMER (4 MILS WET, 1.2 MILS DRY) b. 2ND COAT: S-W PROINDUSTRIAL PRE -CATALYZED WATER BASED EPDXY EG-SHEL c. 3RD COAT: S-W PROINDUSTRIAL PRE -CATALYZED WATER BASED EPDXY EG-SHEL L. PAINT COLOR SCHEDULE: 1. PT-1: CUSTOMER AREA FIELD 2. PT-2: CUSTOMER AREA ACCENT 3. PT-3: OFFICE AREA FIELD 4. PT-4: OFFICE AREA ACCENT 5. PT-5: SERVICE AREA 6. PT-6: STORAGE / MECHANICAL 7. PT-7: BREAK ROOM 7. PT-8: MILD STEEL STAIRS, HANDRAILS AND TRIM 7. PT-9: HARD LID CEILINGS 8. PT-10: TOILET ROOM WALLS 1 (EPDXY) 8. PT-11: TOILET ROOM WALLS 2 (EPDXY) 10 1000 - MISCELLANEOUS SPECIALTIES A. SECTION INCLUDES: PROVIDE MISCELLANEOUS SPECIALTIES AND ACCESSORIES AS SCHEDULED BELOW. B. SUBMITTALS: SUBMIT SHOP DRAWINGS, MANUFACTURER'S SPECIFICATIONS, COLOR AND FINISH SAMPLES, AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. C. SLIDING TRANSACTION WINDOW: 1. BASIS OF DESIGN: CRL (OR APPROVED EQUAL) DW SERIES DELUXE MANUAL SLIDING OXXO TRANSACTION WINDOW WITHOUT SCREEN AS FOLLOWS: a. MODEL: DW3400DU b. COLOR: BRONZE ANODIZED c. GLASS: 1/4" TEMPERED d. LOCK: KEYED LOCK D. PRE -FABRICATED EXTERIOR AWNINGS: 1. BASIS OF DESIGN: PRE -FABRICATED ALUMINUM AND STEEL CANOPY, DESIGN AS SHOWN ON THE DRAWINGS AND AS FOLLOWS: a. MFR: JAG METAL SOLUTIONS, INC, MAPES, OR APPROVED EQUAL: b. COLOR: CUSTOM TO MATCH OVERHEAD DOORS AND BUILDING TRIM C. GUTTERS: INTEGRAL, LOCATIONS TBD, WITH DOWNSPOUTS TO DISCHARGE AT GRADE d. FASCIA: 10" DEPTH SMOOTH FACE (REFER TO DRAWINGS) E. FIRE EXTINGUISHERS & CABINETS: 1. MANUFACTURERS: JL INDUSTRIES, INC; LARSEN'S MANUFACTURING CO., POTTER-ROEMER, OR APPROVED EQUAL. 2. FIRE EXTINGUISHERS: COMPLY WITH PRODUCT REQUIREMENTS OF NFPA 10 AND APPLICABLE CODES, WHICHEVER IS MORE STRINGENT. PROVIDE UL LABELED PRODUCTS. a. TYPE: DRY CHEMICAL TYPE, JL INDUSTRIES COSMIC 10E, STAINLESS STEEL TANK, WITH PRESSURE GAGE, MULTI -PURPOSE CHEMICAL b. CLASS: A, B & C FIRES c. SIZE: 10 lb. d. FINISH: BAKED ENAMEL, RED COLOR 3. FIRE EXTINGUISHER CABINETS: JL INDUSTRIES 1017F10 SERIES, RECESSED OR SURFACE MOUNTED DEPENDING ON WALL TYPE WITH HINGE DOORS WITH CLEAR 1/8 INCH GLASS, AND RED LETTER SIGNAGE. 4. ACCESSORIES: PROVIDE EXTINGUISHER BRACKETS WHERE NOTED ON THE DRAWINGS; JL INDUSTRIES J HOOK, FORMED STEEL, POWDER COATED RED FINISH. F. EMPLOYEE LOCKERS: 12" WIDE X 12" DEEP X 72" HIGH, SINGLE TIER, SURFACE MOUNTED UNITS ON A 4" HIGH METAL BASE WITH A SLOPED TOP WITH CLOSURES. PROVIDE FOR LOCKING BY COMBINATION LOCKS (LOCKING DEVICE SUPPLIED BY OWNER). 1. MANUFACTURERS: LIST INDUSTRIES, INC., SUPERIOR CLASSIC KID WARDROBE LOCKERS, REPUBLIC STORAGE SYSTEMS "STANDARD" SERIES, ASI STORAGE SOLUTIONS "TRADITIONAL" SERIES, LYON WORKSPACE PRODUCTS, PENCO PRODUCTS, INC., OR APPROVED EQUAL. 2. MATERIALS: a. SHEET STEEL: ASTM A 653/A 653M SS GRADE 33/230, WITH G602180 COATING, STRETCHER LEVELED; TO THE FOLLOWING MINIMUM THICKNESSES: b. BODY AND SHELF: 24 GAUGE, 0.024". C. DOOR OUTER FACE: 18 GAUGE, 0.048". d. DOOR INNER FACE, BASE, SLOPING TOP AND TRIM: 20 GAUGE, 0.036". e. DOOR FRAME: 16 GAUGE, 0.060". f. HINGES: 14 GAUGE, 0.075". 3. ACCESSORIES: TWO SINGLE PRONG WALL HOOKS, COAT HANGER BAR. G. INSTALLATION: 1. ALL ACCESSORIES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION GUIDELINES. 2. USE EXPANSION TYPE ANCHORS IN CONCRETE FLOORS. USE SECURITY FASTENERS AT ALL LOCATIONS. 10 1400 - SIGNAGE A. SECTION INCLUDES: ROOM AND DOOR SIGNS, INTERIOR DIRECTIONAL AND INFORMATIONAL SIGNS, EMERGENCY EVACUATION MAPS, BUILDING IDENTIFICATION SIGNS AND PLAQUES. B. SUBMITTALS: SUBMIT SHOP DRAWINGS, PRODUCT DATA, TECHNICAL LITERATURE, SCHEDULES, COLOR SAMPLES, ETC. INDICATE SPACING OF LETTERS AND METHODS OF ANCHORAGE. PROVIDE A SIGNAGE SCHEDULE IDENTIFYING SIGNAGE TEXT AND GRAPHICS FOR APPROVAL BY ARCHITECT. SUBMIT TWO SAMPLES OF EACH TYPE OF SIGN, OF SIZE SIMILAR TO THAT REQUIRED FOR PROJECT, ILLUSTRATING SIGN STYLE, FONT, AND METHOD OF ATTACHMENT. C. DELIVERY, STORAGE, AND HANDLING: PACKAGE SIGNS AS REQUIRED TO PREVENT DAMAGE BEFORE INSTALLATION. PACKAGE ROOM AND DOOR SIGNS IN SEQUENTIAL ORDER OF INSTALLATION, LABELED BY FLOOR OR BUILDING. STORE TAPE ADHESIVE AT NORMAL ROOM TEMPERATURE. D. FIELD CONDITIONS: DO NOT INSTALL TAPE ADHESIVE WHEN AMBIENT TEMPERATURE IS LOWER THAN RECOMMENDED BY MANUFACTURER. MAINTAIN THIS MINIMUM TEMPERATURE DURING AND AFTER INSTALLATION OF SIGNS. E. MANUFACTURERS: ASI SIGN SYSTEMS ARE SPECIFIED TO INDICATE PERFORMANCE, QUALITY AND DESIGN INTENT. APPROVED EQUAL MANUFACTURERS INCLUDE; ACS SIGN SYSTEMS, E&S, ACE SIGN SYSTEMS, ESSENTIAL SIGNS OR APPROVED EQUAL. 1. FLAT SIGNS: ASI SIGN SYSTEMS, BEST SIGN SYSTEMS, INC., MOHAWK SIGN SYSTEMS, INC. 2. CURVED SIGNS: ASI SIGN SYSTEMS - VISTA SYSTEM, OR APPROVED EQUAL 3. DIMENSIONAL LETTER SIGNS: ASI SIGN SYSTEMS. 4. INTERIOR PLAQUE SIGNS: ASI "INTAC", INTERIOR RATED SIGNAGE, WITH HIGH -QUALITY DOMED BRAILLE, SURFACE AND SUBSURFACE GRAPHICS CAPABILITY. F. SIGNAGE APPLICATIONS: ALL SIGNS TO COMPLY WITH ADAAG AND ANSI/ICC A 117.1 AND APPLICABLE BUILDING CODES. ALL SIGNS WILL BE IDENTIFIED WITH A ROOM NUMBER THAT IS TO BE DETERMINED LATER. DO NOT USE THE ROOM NUMBERS SHOWN ON THE DRAWINGS. 1. ROOM AND DOOR SIGNS: PROVIDE A SIGN FOR EVERY DOORWAY, WHETHER IT HAS A DOOR OR NOT, NOT INCLUDING CORRIDORS, LOBBIES, AND SIMILAR OPEN AREAS. PROVIDE 2" HIGH FLAT SIGNS WITH 1" CHARACTER HEIGHT, ENGRAVED PANEL MEDIA AS SPECIFIED, AND "TACTILE" SIGNAGE, WITH LETTERS RAISED MINIMUM 1/32 INCH AND GRADE II BRAILLE, UNLESS OTHERWISE INDICATED. 2. OFFICE DOORS: IDENTIFY WITH ROOM NUMBERS TO BE DETERMINED LATER. IN ADDITION, PROVIDE A "WINDOW" SECTION FOR REPLACEABLE OCCUPANT NAME. 3. CONFERENCE AND MEETING ROOMS: PROVIDE "WINDOW" SECTION WITH SLIDING "IN USE/VACANT" INDICATOR. 4. UTILITY / COMMON ROOM SIGNAGE: PROVIDE BASIC ADA READY SIGNAGE AT STAIRS, MECHANICAL ROOMS, ETC. AS DESIRED BY OWNER. ASI "INTAC", WALL MOUNTED ROOM SIGNAGE, 3" HIGH X 8" WIDE. 5. REST ROOMS: IDENTIFY WITH PICTOGRAMS, THE NAMES "MEN" AND "WOMEN", AND BRAILLE. 6. INTERIOR DIRECTIONAL AND INFORMATIONAL SIGNS: SAME AS ROOM AND DOOR SIGNS, IN SIZES INDICATED ON THE DRAWINGS. 7. EMERGENCY EVACUATION MAPS: MAP CONTENT TO BE PROVIDED BY THE ARCHITECT. 8. BUILDING IDENTIFICATION SIGNS: USE INDIVIDUAL METAL LETTERS MOUNTED IN LOCATION SHOWN ON DRAWINGS. 9. PLAQUE: SEE ALLOWANCE FOR DETAILS. F. SIGN TYPES: SIGNAGE MEDIA WITHOUT FRAME WITH SQUARE EDGES AND CORNERS. 1. CLEAR COVER: FOR CUSTOMER PRODUCED SIGN MEDIA, PROVIDE CLEAR COVER OF POLYCARBONATE PLASTIC, GLOSSY ON BACK, NON -GLARE ON FRONT. 2. WALL MOUNTING OF ONE-SIDED SIGNS: TAPE ADHESIVE. G. CURVED SIGN TYPES: ONE-PIECE CURVED EXTRUDED CLEAR ANODIZED ALUMINUM MEDIA HOLDER SECURING FLAT, FLEXIBLE SIGN MEDIA BY CURVED LIP ON TWO SIDES, CONCEALED MOUNTING ATTACHMENT, IN SIZES INDICATED ON THE DRAWINGS. SIGNAGE TO BE CURVED IN HORIZONTAL SECTION. 1. END CAPS: ALUMINUM WITH FINISH MATCHING FRAME AND STAINLESS STEEL SCREW ATTACHMENT. 2. END CAPS: PLASTIC, COLOR SELECTED FROM MANUFACTURER'S STANDARD COLORS, PAINTABLE. 3. CLEAR COVER: FOR CUSTOMER PRODUCED SIGN MEDIA, PROVIDE CLEAR COVER OF POLYCARBONATE PLASTIC, GLOSSY ON BACK, NON -GLARE ON FRONT. 4. WALL MOUNTING OF ONE-SIDED SIGNS: MECHANICAL ANCHORAGE WITH PREDRILLED HOLES AND SET IN CLEAR SILICONE SEALANT. 5. CHARACTER FONT: HELVETICA, ARIAL, OR OTHER SANS SERIF FONT AS INDICATED, IN UPPER CASE ONLY, AND IN CONTRASTING COLOR. 6. BACKGROUND COLOR: CLEAR. H. TACTILE SIGNAGE MEDIA: 1. ENGRAVED PANELS: 1/16" THICK LAMINATED COLORED PLASTIC; ENGRAVED THROUGH FACE TO EXPOSE CORE AS BACKGROUND COLOR. 2. INJECTION MOLDED PANELS: ONE-PIECE ACRYLIC PLASTIC 1/8" THICK, WITH RAISED LETTERS AND BRAILLE. 3. APPLIED CHARACTER PANELS: 1/8" THICK ACRYLIC PLASTIC BASE, WITH 1/8" THICK APPLIED ACRYLIC PLASTIC LETTERS WITH SQUARE EDGES, AND BRAILLE. I. DIMENSIONAL LETTERS: 1. EXTERIOR BUILDING SIGNAGE: DIMENSIONAL LETTERS 3/4" THICK ACRYLIC LETTERS AS INDICATED IN THE DRAWINGS. SIGN CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL DESIGN DEVELOPMENT TO BE APPROVED BY ARCHITECT PRIOR TO FABRICATION. SIZE OF THE LETTERING TO BE AS INDICATED IN THE DRAWINGS. a. MOUNTING: FLUSH STUD MOUNTING 1" MIN. FROM FACE OF CORRUGATED METAL PANEL SIDING. b. MINIMIZE NUMBER OF ATTACHMENT POINTS WHERE POSSIBLE. 2. EXTERIOR BUILDING SIGNAGE: CUSTOMIZED METAL SIGN PANEL, MOUNTED TO BUILDING OR ELEMENTS AS SHOWN IN THE DRAWINGS a. PANEL MATERIAL: 1/4" THICK ALUMINUM PLATE, WITH POWDER COAT TO MATCH FENCE COLOR, SIZE AS INDICATED IN THE DRAWINGS. b. GRAPHICS: PRECISION CUT VINYL LETTERING / GRAPHICS ON PLATE, UNLESS NOTED OTHERWISE C. THE ARCHITECT SHALL PROVIDE THE SIGN COMPANY WITH LOGO DESIGN AND INITIAL LAYOUT PRIOR TO SHOP DRAWING SUBMITTAL. d. MOUNTING: ATTACH SIGN PANEL TO FENCING AS REQUIRED WITH COLOR MATCHED, CONCEALED TYPE SECURITY FASTENERS. J. SITE SIGNAGE: ADA AND SITE RELATED SIGNAGE COMPONENTS. SEE SITE DESIGN DRAWINGS. K. ACCESSORIES: 1. CONCEALED SCREWS: STAINLESS STEEL, GALVANIZED STEEL, CHROME PLATED, OR OTHER NON -CORRODING METAL. 2. TAPE ADHESIVE: DOUBLE SIDED TAPE, PERMANENT ADHESIVE. L. INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. INSTALL WHERE DESIGNATED ON THE DRAWINGS, NEATLY, WITH HORIZONTAL EDGES LEVEL. 2. ROOM AND DOOR SIGNS: LOCATE ON WALL AT LATCH SIDE OF DOOR WITH CENTERLINE OF SIGN AT 60 INCHES ABOVE FINISHED FLOOR. 3. PROTECT FROM DAMAGE UNTIL SUBSTANTIAL COMPLETION; REPAIR OR REPLACE DAMAGE ITEMS. 10 2800 - TOILET, BATH & LAUNDRY ACCESSORIES A. SECTION INCLUDES: ACCESSORIES FOR TOILET ROOMS, SHOWERS, AND UTILITY ROOMS, AND GRAB BARS. B. SUBMITTALS: PROVIDE DATA ON ACCESSORIES DESCRIBING SIZE, FINISH, DETAILS OF FUNCTION, ATTACHMENT METHODS. C. MANUFACTURERS: PRODUCTS LISTED ARE MADE BY BOBRICK. OTHER ACCEPTABLE MANUFACTURERS: AMERICAN SPECIALTIES, INC., BRADLEY CORPORATION OR APPROVED EQUAL. D. MATERIALS: 1. ACCESSORIES - GENERAL: SHOP ASSEMBLED, FREE OF DENTS AND SCRATCHES AND PACKAGED COMPLETE WITH ANCHORS AND FITTINGS, STEEL ANCHOR PLATES, ADAPTERS, AND ANCHOR COMPONENTS FOR INSTALLATION. 2. KEYS: PROVIDE 3 KEYS FOR EACH ACCESSORY TO OWNER; MASTER KEY ALL LOCKABLE ACCESSORIES. 3. STAINLESS STEEL SHEET: ASTM A 666, TYPE 304. 4. MIRROR GLASS: FLOAT GLASS, ASTM C 1036 TYPE I, CLASS 1, QUALITY Q2, WITH SILVERING. 5. FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED, TAMPER -PROOF, SECURITY TYPE. E. FINISHES: 1. STAINLESS STEEL: NO.4 SATIN BRUSHED FINISH. 2. CHROME/NICKEL PLATING: ASTM B 456, SC 2, SATIN FINISH. 3. GALVANIZING FOR ITEMS OTHER THAN SHEET: COMPLY WITH ASTM A 123/A 123M; GALVANIZE FERROUS METAL AND FASTENING DEVICES. 4. BACK PAINT COMPONENTS WHERE CONTACT IS MADE WITH BUILDING FINISHES TO PREVENT ELECTROLYSIS. F. TOILET ROOM ACCESSORIES: 1. TOILET PAPER DISPENSER: DOUBLE ROLL, RECESSED, STAINLESS STEEL UNIT WITH PIVOT HINGE, TUMBLER LOCK. PRODUCT: BOBRICK B-3888. 2. TOILET PAPER DISPENSER: DOUBLE ROLL, SURFACE MOUNTED, STAINLESS STEEL UNIT WITH PIVOT HINGE, TUMBLER LOCK. PRODUCT: BOBRICK B-2888. 3. COMBINATION TOWEL DISPENSER/WASTE RECEPTACLE: RECESSED FLUSH WITH WALL, STAINLESS STEEL; SEAMLESS WALL FLANGES, CONTINUOUS PIANO HINGES, TUMBLER LOCKS ON UPPER AND LOWER DOORS. PRODUCT: BOBRICK B-369. a. WASTE RECEPTACLE: REUSABLE, HEAVY-DUTY VINYL WITH 2 GALLON CAPACITY. b. TOWEL DISPENSER CAPACITY: 350 C-FOLD. 4. COMBINATION TOWEL DISPENSER/WASTE RECEPTACLE: RECESSED FLUSH WITH WALL, STAINLESS STEEL; SEAMLESS WALL FLANGES, CONTINUOUS PIANO HINGES, TUMBLER LOCKS ON UPPER AND LOWER DOORS. PRODUCT: BOBRICK B-3944 a. WASTE RECEPTACLE: REUSABLE, HEAVY-DUTY VINYL WITH 12 GALLON CAPACITY. b. TOWEL DISPENSER CAPACITY: 600 C-FOLD. 5. MIRRORS: TYPE 430 STAINLESS STEEL FRAMED WITH BRIGHT POLISHED FINISH, 6 MM THICK FLOAT GLASS MIRROR, SIZED AS INDICATED ON THE SCHEDULE. ONE-PIECE 1/2" X 1/2" X 1/2" CHANNEL FRAME. PRODUCT: BOBRICK B-165. a. BACKING: FULL -MIRROR SIZED, MINIMUM 0.03 INCH GALVANIZED STEEL SHEET AND NON -ABSORPTIVE FILLER MATERIAL. b. CONCEALED HANGERS WITH THEFT -RESISTANT MOUNTING. 6. SEAT COVER DISPENSER: STAINLESS STEEL, SURFACE -MOUNTED, RELOADING FROM THE BOTTOM, TUMBLER LOCK. DISPENSES 250 SEAT COVERS, EACH SIDE. PRODUCT: BOBRICK B-221. 7. GRAB BARS: STAINLESS STEEL, 1-1/4 INCHES OUTSIDE DIAMETER, MINIMUM 0.05 INCH WALL THICKNESS, NON -SLIP GRASPING SURFACE FINISH, CONCEALED FLANGE MOUNTING; 1-1/2 INCHES CLEARANCE BETWEEN WALL AND INSIDE OF GRAB BAR. SIZES AS INDICATED ON THE DRAWINGS. PRODUCT: BOBRICK B-5806. 8. COMBINATION SANITARY NAPKINITAMPON DISPENSER: STAINLESS STEEL, RECESSED MOUNTED. DOOR: SEAMLESS 0.05 INCH DOOR WITH RETURNED EDGES AND TUMBLER LOCK. PRODUCT: BOBRICK B-3500. a. CABINET: FULLY WELDED, 0.03 INCH THICK SHEET. b. OPERATION: 25 CENT COIN REQUIRED TO OPERATE DISPENSER. PROVIDE LOCKED COIN BOX, SEPARATELY KEYED. C. MINIMUM CAPACITY: 31 NAPKINS AND 22 TAMPONS. 9. SANITARY NAPKIN DISPOSAL UNIT: STAINLESS STEEL, RECESSED MOUNTED, SELF -CLOSING DOOR, LOCKING BOTTOM PANEL WITH FULL-LENGTH STAINLESS STEEL PIANO -TYPE HINGE, REMOVABLE RECEPTACLE. PRODUCT: BOBRICK B-35303. 10. SANITARY NAPKIN DISPOSAL UNIT: STAINLESS STEEL, PARTITION MOUNTED, SELF -CLOSING DOOR, LOCKING BOTTOM PANEL WITH FULL-LENGTH STAINLESS STEEL PIANO -TYPE HINGE, REMOVABLE RECEPTACLE. PRODUCT: BOBRICK B-354. 11. DIAPER CHANGING STATION: WALL -MOUNTED POLYETHYLENE FOLDING DIAPER CHANGING STATION FOR USE IN COMMERCIAL TOILET FACILITIES, MEETING OR EXCEEDING ASTM F 2255. PRODUCT: KOALAKARE KB100-00. a. STYLE: HORIZONTAL, SURFACE -MOUNTED. b. COLOR: CREAM G. SHOWER AND TUB ACCESSORIES: 1. SHOWER CURTAIN ROD: STAINLESS STEEL TUBE, 1 INCH OUTSIDE DIAMETER, SATIN -FINISHED, WITH 3 INCH OUTSIDE DIAMETER, MINIMUM 0.04 INCH THICK SATIN -FINISHED, STAINLESS STEEL FLANGES, FOR INSTALLATION WITH CONCEALED MOUNTING. PRODUCT: BOBRICK B-207. 2. SHOWER CURTAIN: OPAQUE VINYL 0.008 INCH THICK WITH ANTIBACTERIAL TREATMENT FLAMEPROOF AND STAIN -RESISTANT. SIZE: 42 BY 72 INCHES, WITH NICKEL -PLATED BRASS GROMMETS AT 6" ON CENTER. BOTTOM AND SIDES ARE HEMMED. PRODUCT: BOBRICK 204-2 ALONG WITH STAINLESS STEEL HOOKS - BOBRICK 204-1 (7 PER CURTAIN). 3. FOLDING SHOWER SEAT: ADA COMPLIANT WALL -MOUNTED, WELDED TUBULAR SEAT FRAME, STRUCTURAL SUPPORT MEMBERS, HINGES AND MECHANICAL FASTENERS OF TYPE 304 STAINLESS STEEL L SHAPED PHENOLIC OR POLYMERIC COMPOSITE ONE-PIECE SEAT SLATS. PRODUCT: BOBRICK B-5181. H. UTILITY ROOM ACCESSORIES: 1. MOP AND BROOM HOLDER: 36" LONG STAINLESS STEEL, TYPE 304, WITH 4 SPRING -LOADED RUBBER CAM HOLDERS. PRODUCT: BOBRICK B-223. 2. COMBINATION UTILITY SHELF/MOP AND BROOM HOLDER: 36" LONG X 8" DEEP 18 GAUGE STAINLESS STEEL SHELF, TYPE 304, WITH 4 SPRING -LOADED RUBBER CAM HOLDERS, AND 3 RAG HOOKS, AND STAINLESS STEEL DRYING ROD. PRODUCT: BOBRICK B-224. 12 2118 - FABRIC ROLLING SHADES A. SECTION INCLUDES: HORIZONTAL FABRIC ROLLING SHADES AND OPERATING HARDWARE. B. SUBMITTALS: PROVIDE PRODUCT DATA INDICATING PHYSICAL AND DIMENSIONAL CHARACTERISTICS. SUBMIT SHOP DRAWINGS THAT INDICATE OPENING SIZES, TOLERANCES REQUIRED, METHOD OF ATTACHMENT, CLEARANCES, AND OPERATION. C. MANUFACTURERS: ACCEPTABLE MANUFACTURERS INCLUDE; HUNTER DOUGLAS, LEVOLOR GLOBE, BALI, DRAPER, BLINDS.COM OR APPROVED EQUAL. D. FABRIC SHADES: 1. SHADES: DRAPER ROLLER SHADES, SHEAR WEAVE - 3000 FABRIC, PATTERN AND COLOR AS SELECTED BY ARCHITECT. FABRIC CONTENTS TO BE CHEMICALLY FLAME RETARDANT, FADE AND STAIN RESISTANT. 2. TYPICAL MOUNTING: JAMB -MOUNTED WITH STEEL BRACKETS. INSTALL AT INTERIOR WINDOW HEADS. THE BOTTOM OF THE SHADES SHALL EXTEND TO THE WINDOW STOOL. 3. CURTAIN WALL MOUNTED: MOUNTED TO THE FACE OF CURTAIN WALL SYSTEM WITH COMPATIBLE BRACKETS. PROVIDE FASCIA TO CONCEAL THE SHADE ROLLER MECHANISM OF ANODIZED ALUMINUM MATERIAL TO MATCH GLAZING SYSTEM. 4. HARDWARE: 1 INCH DIAMETER TUBE CLUTCH ROLLER SYSTEM, REVERSE ROLL TO HIDE TUBE, MANUAL OPERATION, AND POLYESTER WRAPPED. E. INSTALLATION: 1. REMOVE EXISTING WINDOW TREATMENTS UTILIZING A SUB=CONTRACTOR EXPERIENCED IN THE INSTALLATION AND OPERATION OF TYPICAL WINDOW TREATMENT SYSTEMS. 2. VERIFY THAT SURFACES AND CONDITIONS IN WHICH WINDOW TREATMENTS WILL BE INSTALLED ARE FREE OF CONDITIONS INTERFERING WITH BLIND INSTALLATION. DO NOT BEGIN INSTALLATION UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3. INSTALL NEW WINDOW TREATMENTS IN ACCORDANCE WITH ACCEPTED SHOP DRAWINGS AND MANUFACTURER'S RECOMMENDATIONS. INSTALL INTERMEDIATE SUPPORT BRACKETS WHERE REQUIRED. INSTALL WITH ADEQUATE CLEARANCE TO PERMIT UNENCUMBERED OPERATION. F. ADJUSTING: ADJUST BLIND CLEARANCES AND OVERLAPS. G. CLEANING: CLEAN SOILED SURFACES AND COMPONENTS JUST PRIOR TO OCCUPANCY. 12 3600 - MANUFACTURERD CASEWORK A. SECTION INCLUDES: BASE UNITS, WALL UNITS, STORAGE UNITES, COUNTERTOPS, ACCESSORIES AND HARDWARE AS SHOWN AND SPECIFIED. COORDINATE WITH CARPENTRY, PLUMBING AND ELECTRICAL CONTRACTORS FOR PROPER INSTALLATION AND HOOKUP. B. SUBMITTALS: 1. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO BE USED, INCLUDING: a. TEST REPORTS CERTIFYING THAT THE CASEWORK FINISH COMPLIES WITH SEFA-8 STANDARDS FOR CHEMICAL AND PHYSICAL RESISTANCE PERFORMANCE REQUIREMENTS. b. PERFORMANCE TEST REPORTS FROM AN INDEPENDENT TESTING LAB ON EACH SPECIFIED TOP MATERIAL. C. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS. d. STORAGE AND HANDLING REQUIREMENTS AND RECOMMENDATIONS. e. INSTALLATION METHODS. 2. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. a. INDICATE LOCATIONS OF BLOCKING AND REINFORCEMENTS REQUIRED FOR INSTALLING LABORATORY CASEWORK. b. INDICATE LOCATIONS AND TYPES OF SERVICE FITTINGS, TOGETHER WITH ASSOCIATED SERVICE SUPPLY CONNECTION REQUIRED. C. INCLUDE DETAILS OF UTILITY SPACES. d. INCLUDE INDICATORS OF EXPOSED CONDUITS, IF REQUIRED, FOR SERVICE FITTINGS. e. INDICATE LOCATIONS OF AND CLEARANCES FROM ADJACENT WALLS, DOORS, WINDOWS, OTHER BUILDING COMPONENTS, AND OTHER LABORATORY EQUIPMENT. f. INCLUDE COORDINATED DIMENSIONS FOR LABORATORY EQUIPMENT SPECIFIED IN OTHER SECTIONS. 3. SELECTION SAMPLES: PROVIDE ONE (1) COMPLETE SET OF COLOR CHIPS REPRESENTING MANUFACTURER'S FULL RANGE OF AVAILABLE COLORS AND PATTERNS. a. ONE SET OF SAMPLES INDICATING FULL RANGE OF FINISHES FOR COUNTERTOP SPECIFIED. b. ONE SET OF CASEWORK SAMPLES INDICATING FULL RANGE OF FINISHES FOR CASEWORK SPECIFIED. B. COUNTERTOP & CASEWORK ASSEMBLIES: 1. PRODUCT DESIGNATIONS: DRAWINGS INDICATE SIZES AND CONFIGURATIONS OF CASEWORK, COUNTERTOPS, AND ACCESSORIES BY REFERENCING DIMENSIONAL REQUIREMENTS AND GENERAL DESCRIPTIONS. 2. PROVIDE FILLERS TRIM NECESSARY TO MAKE WORK COMPLETE AND WORKABLE AND MOLDINGS NECESSARY TO CONCEAL JOINTS AT INTERSECTION OF CABINETS WITH WALLS AND CEILINGS. 3. PROVIDE CABINET DRAWER AND DOOR HARDWARE AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. 4. TOE SPACE, FILLERS AND FACE FRAME: HIGH DENSITY LAMINATE TO MATCH DRAWER AND DOOR FRONTS. C. CONSTRUCTION: 1. EXPOSED CABINET EXTERIORS AND COUNTERTOPS: COMPLETELY FACTORY FINISHED HIGH DENSITY LAMINATE ON PARTICLEBOARD CORE, COLOR AS SELECTED BY ARCHITECT 2. EXPOSED CABINET INTERIORS: LOW PRESSURE LAMINATE WITH WHITE MELAMINE COATING. INTERIOR EDGES TO BE PVC. 3. CABINET SURFACE FINISH: HIGH DENSITY LAMINATE. REFER TO THE DRAWINGS FOR LAMINATE TYPES AND LOCATION. 4. DOOR AND DRAWER HARDWARE STYLE: a. DOOR HINGES: MANUFACTURER'S STANDARD HEAVY DUTY TYPE, ADJUSTABLE FOR PROPER FIT AND FIELD OPERATION b. DRAWER SLIDES: DRAWER SLIDES MANUFACTURER'S STANDARD HEAVY DUTY TYPE, EQUIPPED WITH HEAVY-DUTY, NYLON ROLLERS FOR SMOOTH EFFORTLESS OPERATION. SLIDES HAVE AUTOMATIC POSITIVE STOP TO PREVENT DRAWER'S ACCIDENTAL REMOVAL, BUT ALLOW FOR QUICK REMOVAL WITHOUT TOOLS. 5. DRAWER & DOOR PULLS: 4" CHROME WIRE PULLS E. ACCESSORY MATERIALS: 1. PLYWOOD FOR SUPPORTING SUBSTRATE: PS 1 EXTERIOR GRADE, A-C VENEER GRADE, MINIMUM 5-PLY; MINIMUM 3/4" THICK; JOIN LENGTHS USING METAL SPLINES. 2. PARTICLEBOARD FOR SUPPORTING SUBSTRATE: ANSI A208.1 GRADE 2-M-2, 45 PCF MINIMUM DENSITY; MINIMUM 3/4" THICK; JOIN LENGTHS USING METAL SPLINES. 3. ADHESIVES: CHEMICAL RESISTANT WATERPROOF ADHESIVE AS RECOMMENDED BY MANUFACTURER OF MATERIALS BEING JOINED. 4. JOINT SEALANT: MILDEW -RESISTANT SILICONE SEALANT, CLEAR OR COLOR AS SELECTED BY THE ARCHITECT. F. FABRICATION: 1. FABRICATE TOPS AND SPLASHES IN THE LARGEST SECTIONS PRACTICABLE, WITH TOP SURFACE OF JOINTS FLUSH. 2. JOIN LENGTHS OF TOPS USING BEST METHOD RECOMMENDED BY MANUFACTURER. 3. FABRICATE TO OVERHANG FRONTS AND ENDS OF CABINETS VEXCEPT WHERE TOP BUTTS AGAINST CABINET OR WALL. 4. PREPARE ALL CUTOUTS ACCURATELY TO SIZE; REPLACE TOPS HAVING IMPROPERLY DIMENSIONED OR UNNECESSARY CUTOUTS OR FIXTURE HOLES. 5. PROVIDE 4" HIGH BACK/END SPLASH WHEREVER COUNTER EDGE ABUTS VERTICAL SURFACE. 6. SECURE TO COUNTERTOP WITH CONCEALED FASTENERS AND WITH CONTACT SURFACES SET IN WATERPROOF GLUE. 7. UNITS AND CONFIGURATION DESIGNATED FOR ACCESSIBILITY BY USERS SHALL COMPLY WITH THE ADAAG (ADA STANDARDS). 8. DESIGN, MATERIAL AND CONSTRUCTION OF CASEWORK, SHELVING AND TABLES SHALL COMPLY WITH SEFA 8 STANDARDS. 9. CABINET CONSTRUCTION IS BORED, DOWELED, DADOED, GLUED AND SCREWED CONSTRUCTION, PER AWISTANDARDS. a. PROVIDE ADJUSTABLE SHELVING COMPONENTS FOR WALL MOUNTED CABINETS. G. PREPARATION: CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE SUBSTRATE UNDER THE PROJECT CONDITIONS. FIELD VERIFY CONDITIONS FOR PROPER FIT PRIOR TO FABRICATION. H. COORDINATION: COORDINATE DESIGN AND INSTALLATION WITH MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTORS WHO SHALL FURNISH, INSTALL AND CONNECT MEP COMPONENTS. G. INSTALLATION: SECURELY ATTACH COUNTERTOPS AND CASEWORK TO ADJACENT WALLS AND CABINETRY USING CONCEALED FASTENERS. MAKE FLAT SURFACES LEVEL; SHIM WHERE REQUIRED. ATTACH PLASTIC LAMINATE COUNTERTOPS USING SCREWS WITH MINIMUM PENETRATION INTO SUBSTRATE BOARD OF 5/8". SEAL JOINT BETWEEN BACK / END SPLASHES AND VERTICAL SURFACES. SEAL JOINTS BETWEEN CASEWORK AND DISSIMILAR MATERIALS. LUBRICATE OPERATING HARDWARE AS RECOMMENDED BY THE MANUFACTURER. PROVIDE REQUIRED HOLES AND CUTOUTS FOR SERVICE FITTINGS. PROVIDE SCRIBE MOLDINGS FOR CLOSURES AT JUNCTURES OF COUNTERTOP, CURB, AND SPLASH, WITH WALLS AS RECOMMENDED BY MANUFACTURER FOR MATERIALS INVOLVED. H. PROTECT, ADJUST, & CLEAN: PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT. CAREFULLY DRESS JOINTS SMOOTH, REMOVE SURFACE SCRATCHES, AND CLEAN ENTIRE SURFACE THOROUGHLY. ENSURE THAT OPERATING PARTS WORK FREELY AND FIT NEATLY. ADJUST HARDWARE AND MOVING PARTS AS NECESSARY. REPAIR OR REPLACE DAMAGED PARTS, DENTS, BUCKLES, ABRASIONS, OR OTHER DEFECTS AFFECTING APPEARANCE OR SERVICEABILITY, SO THAT UNITS ARE IN UNDAMAGED CONDITION AT TIME OF FINAL ACCEPTANCE. CERTIFIED BY: ♦♦`► ► //' �♦`♦C''' fil �ky .i �`e••\STF. � . -1 •GNo.RF = 0 900019 0 = STATE OF .. IN.DIN Lu W Q N < cy) Of O U O 0�,ql- z O C)H W Q � U z J Z Q 0- z= D D w Ei oz c) �: z O O � a V Z z __ F- J Q z O J 2 J =" U L.L W 3: LU Z 2E w J z J � U 2 DRAWING ARCHITECTURAL SPECIFICATIONS ISSUE 100% CONST. DOCUMENTS - 05/15/2020 90% CONST. DOCUMENTS - 04/01/2020 DESIGN DEVELOPMENT SET-01/16/2020 REVISIONS 1 - 2 - 3 - 4 - PROJECT NUMBER 1832 DATE MAY 15, 2020 AOm5 Lel