A2.2
UP UP A5.1 2 A5.1 3 A5.1 4 A5.1 1 A A A.6 B.1 B.7 C B.2 C.8 C.9 D E E 1 1 2 2 3 3 4 4 4.4 4.4 5 5 A.1 D.9 A6.1 1 A6.1 1 A6.1 2 STAIR S2-1OPEN TO BELOW 11'-8"25'-9"22'-9"19'-10"1 1/4"42'-5 3/4"2'-9"8'-1 1/2"4'-0"8'-1 1/2"2'-9"1 1/4"21'-1 3/4"28'-0"31'-4"31'-5"4'-0" 17'-8"25'-0"15'-0"15'-0"25'-0"21'-3"28'-0"31'-4"31'-5" 17'-8" W7 W7 ATTIC 200 PARTS STORAGE 201 MECHANICAL 204 BREAK ROOM 202 15'-2 1/8"23'-10 1/2"17'-4 1/4" 4'-9"16'-8 1/2" TOILET 2035'-7"7'-1"203202 4.3 6 6 80'-0"112'-0"80'-0"4'-4" A7.1 1 31'-2"A8.1 7 9'-0"TYP. 1 TYP. 1 2 2 3 3 4 +11'-6" +10'-0" 2 GENERAL PLAN NOTES: 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES. 2. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED OTHERWISE. 3. ALL DOOR FRAME OPENINGS SHALL BE 6" FROM ADJACENT WALLS UNLESS NOTED OTHERWISE. 4. PROVIDE NECESSARY BLOCKING (FIRE TREATED), CONCEALED WITHIN THE CONSTRUCTION, AS REQUIRED FOR ANY AND ALL ITEMS THAT MUST BE SECURED TO THE WALL. VERIFY LOCATIONS WITH OWNER. 5. REFER TO WINDOW & DOOR SCHEDULES ON SHEET A9.1 FOR SIZE, TYPE, AND FINISH OF ALL DOORS, FRAMES, AND WINDOWS. 6. REFER TO PLUMBING PLANS FOR ALL PLUMBING FIXTURE LOCATIONS, SPECIFICATIONS, AND FIXTURE COUNTS. THE ARCHITECTURAL FLOOR PLANS ARE FOR DESIGN INTENT ONLY. 7. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.1 FOR ALL FINISHES. F.E.C. NEW DOOR AND FRAME NEW INTERIOR PARTITION -SEE WALL TYPES WALL LEGEND FIRE EXTINGUISHER CABINET 25 GA. 2 1/2" METAL STUDS @ 16" O.C. WITH 5/8" GYP. BD ONE SIDE ONLY TO DECK ABOVE. 25 GA. 6" METAL STUDS @ 16" O.C. WITH BATT INSULATION AND 5/8" GYP. BOARD BOTH SIDES TO DECK ABOVE. 25 GA. 3 5/8" METAL STUDS @ 16" O.C. WITH 5/8" GYP. BD. ONE SIDE ONLY TO DECK ABOVE. 25 GA. 3 5/8" METAL STUDS @ 16" O.C. WITH BATT INSULATION AND 5/8" GYP. BD BOTH SIDES TO DECK ABOVE. WALL TYPES 25 GA. 6" METAL STUDS @ 16" O.C. WITH 5/8" GYP. BD. ONE SIDE ONLY TO DECK ABOVE. W1 W2 W5 W3 W4 STATE OF 900019 No.MICHAE L W .HALS T E ADIND I A N AREGISTER E DARCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2020 Halstead Architects All Rights ReservedSTATE RFI - 06/01/2020 - - - - DESIGN DEVELOPMENT SET - 01/16/2020 90% CONST. DOCUMENTS - 04/01/2020NEW CONSTRUCTION FORMILLER AUTO CARE985 N. RANGELINE ROADCARMEL, INDIANA 46032HAMILTON COUNTYCLAY TOWNSHIP100% CONST. DOCUMENTS - 05/15/2020 1 2 3 4 A2.2 1832 MAY 15, 2020 MEZZANINE FLOOR PLAN SCALE: 1/8" = 1'-0"1 MEZZANINE PLAN KEYNOTES 1 STRUCTURAL STEEL COLUMN (SEE FRAMING PLANS - PAINTED). 2 METAL STUD FRAMED GAURDRAIL WITH WOOD CAP. PROVIDE STEEL SUPPORT FRAME WITH VERTICAL MEMBERS SPACED 6' O.C. WELDED TO FLOOR STRUCTURE BELOW (SEE SHEET A7.1). 3 PREFABRICATED CANOPY BELOW. 4 MECHANICAL EQUIPMENT (SEE MECH. DWGS.)