HomeMy WebLinkAboutA3.1GENERAL RCP NOTES 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES. 2. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED OTHERWISE. 3. EACH CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR OMISSIONS TO THE ARCHITECT. 4. REFER TO ROOM FINISH SCHEDULE ON SHEET A9.1 FOR MATERIALS, CEILING HEIGHTS, AND FINISH FOR ALL NEW CEILINGS. 5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE REFLECTED CEILING PLANS AND THE ELECTRICAL DRAWINGS. 6. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR FIRE ALARM AND EMERGENCY LIGHTING COMPONENTS. 7. COORDINATE ALL MECHANICAL SYSTEM BULKHEAD SIZES WITH MECHANICAL DRAWINGS PRIOR TO INSTALLATION OF SPRINKLER SYSTEM. 8. REFER TO ELECTRIC LIGHTING PLANS FOR FIXTURE QUANTITIES, MANUFACTURERS AND MODEL NUMBERS. THE REFLECTED CEILING PLAN IS FOR FIXTURE ORIENTATIONS, LOCATIONS AND CEILING GRID LAYOUT. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF THE REFLECTED CEILING PLANS DIFFERS FROM THE ELECTRICAL LIGHTING PLANS. 9. SPRINKLER HEADS AND RECESSED CAN LIGHTS ARE TO BE LOCATED IN THE CENTER OF THE AFFECTED CEILING PANEL. WHERE THE CEILING PANEL HAS A CENTER REVEAL, THE SPRINKLER HEAD OR LIGHT FIXTURE SHALL BE LOCATED IN THE CENTER OF THE 2'x2' PORTION OF THAT CEILING PANEL. EXIT LIGHT 2 x 4 FLUORESCENT RECESSED FIXTURE RECESSED INCANDESCENT LIGHT 2 x 4 FLUORESCENT RECESSED FIXTURE (NIGHT LIGHT) OUTDOOR WALL MOUNTED LIGHT FIXTURE 1 x 4 FLUORESCENT SURFACE- MOUNTED FIXTURE E EMERGENCY LIGHT PENDANT MOUNTED HIGH-BAY FIXTURE LEGEND 2 x 4 ACOUSTIC CEILING SYSTEM GYPSUM BOARD CEILING ELEVATION MARKX'-X"2"SEE REF. CLG. PLAN B. / CEILING (SEE ROOM FINISH SCHED.) 25 ga. 3 5/8" METAL STUD BRACING @ 48" O.C. (TYPICAL) 25 ga. 3 5/8" METAL STUDS @ 16" O.C. TO DECK ABOVE SCHEDULED CEILING 5/8" GYPSUM BOARD (TYP.) B. / CEILING (SEE ROOM FINISH SCHED.) 25 ga. 3 5/8" METAL STUD BRACING @ 48" O.C. (TYPICAL) 5/8" GYPSUM BOARD (TYP.) 25 ga. 3 5/8" METAL STUDS @ 16" O.C. TO DECK ABOVE SCHEDULED CEILING TYP BULKHEAD TYP LARGE BULKHEAD2"A A.6 B.1 B.7 C.9 D E 4 4 4.4 4.4 5 5 A.1 D.9 A6.1 2 4.3 6 6 WAITING 100 SERVICE DESK 101 WORKROOM 104 TOILET 103 TOILET 102 STAIR S1-1 ALIGNMENT BAY 113 REPAIR BAY 119 STAFF TOILET 110 OFFICE 107DRESSING ROOM 106 OFFICE 105 CLO. 108 1 1 2 2 3 44 E E E EEE E 7'-10" 7'-10" 3 A A A.6 B.1 B.7 C B.2 C.8 C.9 D E E 1 1 2 2 3 3 4 4 4.4 4.4 5 5 A.1 D.9 A6.1 1 A6.1 2 4.3 6 6 ATTIC 200 PARTS STORAGE 201 BREAK ROOM 202 TOILET 203 MECHANICAL 204 EEE EESLOPE DOWNSLOPE DOWNSLOPE DOWNSLOPE DOWNTYP. 5 TYP. 5 TYP. 5 TYP. 5 STATE OF 900019 No.MICHAE L W .HALS T E ADIND I A N AREGISTER E DARCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2020 Halstead Architects All Rights ReservedSTATE RFI - 06/01/2020 - - - - DESIGN DEVELOPMENT SET - 01/16/2020 90% CONST. DOCUMENTS - 04/01/2020NEW CONSTRUCTION FORMILLER AUTO CARE985 N. RANGELINE ROADCARMEL, INDIANA 46032HAMILTON COUNTYCLAY TOWNSHIP100% CONST. DOCUMENTS - 05/15/2020 1 2 3 4 A3.1 1832 MAY 15, 2020 REFLECTED CEIILNG PLANS SCALE: 1" = 1'-0"3 RCP Bulkhead Detail SCALE: 1/8" = 1'-0"1 REFLECTED CLG. PLANFIRST FLOOR SCALE: 1/8" = 1'-0"2 REFLECTED CLG. PLANMEZZANINE KEYNOTES 1 CANOPY WITH ALUMINUM SOFFIT SYSTEM. 2 EXPOSED STRUCTURAL STEEL FRAMING TO BE PAINTED - TYP (SEE FRAMING PLANS). 3 STAIR FRAMING ABOVE TO BE PAINTED. 4 METAL STUD FRAMED AND GYP. BOARD BULKHEAD (SEE DETAIL 3/A3.1) 5 OPEN TO STRUCTURE ABOVE (STEEL TO BE SHOP PRIMED)