HomeMy WebLinkAboutA101 - Floor and Roof Plan, Porch Section1
A1.02
2
A1.02
3
A1.02
3
A1.01
11' - 7 3/8" (+,-)12' - 7 5/8"1/2"7" 3' - 5 3/4" 5" 3' - 7" 5" 3' - 5 3/4" 7" 1/2" 5' - 9"
1' - 0 1/2" 2' - 8" 2' - 0 1/2"
1/2"7" 5" 2' - 8" 5" 1' - 2 1/2" 5"
5 1/2" WOOD POST w/ 3/4"
WOOD TRIM, PAINTED FINISH,
PROVIDE POST BASE ANCHOR,
STRONG-TIE OR EQUAL
3 1/2" WOOD POST w/ 3/4"
WOOD TRIM, PAINTED FINISH
1 1/4" SILL CAP WITH 1/8" WASH
1 1/2" x 1 1/2" WOOD STOP,
TYPICAL
ALIGN FACE OF LOWER TRIM
WITH FACE OF EXISTING
CONCRETE WALL BELOW,
TYPICAL
EXISTING PAVER PATIO
EXISTING STEPS
EXISTING RAISED
CONCRETE PATIO
ALIGN w/BUILDING FACE1' - 10" 14' - 6" (+,-)17' - 6 3/4" (+,-)16' - 4"
1' - 10"8" 2' - 4"2' - 4"5 1/2" WOOD POST w/ 3/4"
WOOD TRIM, PAINTED FINISH
(2 LOCATIONS), PROVIDE POST
BASE ANCHOR, STRONG-TIE
OR EQUAL
CAST STONE CAP ON MASONRY PIER
(MATCH EXISTING MASONRY)
ON 3'-0" x 3'-0" x 15" CONCRETE FOOTING,
MIN. DEPTH @ +30" BELOW GRADE LINE
ALIGN COLUMNS
PROVIDE WP OUTLET IN CEILING,
TIE INTO EXISTING CIRCUIT PER
CURRENT CODES
PROVIDE WP OUTLET IN CEILING,
TIE INTO EXISTING CIRCUIT PER
CURRENT CODES
PROVIDE JUNCTION BOX FOR
NEW CEILING FAN. TIE INTO
EXISTING POWER PER CURRENT
CODES
PROVIDE JUNCTION BOX FOR
NEW CEILING FAN. TIE INTO
EXISTING POWER PER CURRENT
CODES
4
A1.02
1
1
1
1
1
A. REFERENCE SHEET A0.00 FOR GENERAL PROJECT INFORMATION,
WALL TYPES, SYMBOLS AND PROJECT SCOPE DEFINITIONS.
B. REFERENCE SITE PLAN FOR INFORMATION REGARDING
DRIVES, SIDEWALKS, RAMPS, FENCES, ETC.
C. CONFORM ALL CONSTRUCTION TO THE CODES INDICATED ON
SHEET A0.00 AS WELL AS LOCAL, COUNTY, AND/OR CITY
JURISDICTIONS.
D. FIRESTOP ALL PENETRATIONS THROUGH FIRE-RATED
ASSEMBLIES AND THROUGH EACH FLOOR.
E. FLOOR PLAN DIMENSIONS ARE INDICATED FROM FACE OF STUD
AND FACE OF MASONRY UNLESS OTHERWISE INDICATED.
F. PROVIDE 2X SOLID BLOCKING AND GROUNDS AS REQ'D TO
SUPPORT WALL-MOUNTED ITEMS.
GENERAL NOTES
1
A1.02
2
A1.02
3
A1.02
3
A1.01
AREA OF NEW ROOF, MATCH
EXISTING SLOPE AND FRAMING/
SOFFIT ELEVATION, ASPHALT
SHINGLESTO MATCH EXISTING
ROOF
NEW ALUMINUM GUTTER AND
DOWNSPOUT TO MATCH EXISTING
HOUSE, TYPICAL
EXISTING ROOF
4
A1.02
First Floor
100' - 0"
Patio Level
99' - 6"
110' - 8"
GUTTER BOARD LINE HEIGHT
(V.I.F.)
110' - 0"
B.O. BEARING
(V.I.F.)
109' - 4"
B.O. TRIM
109' - 9 3/4"
NEW 2 x 8 ROOF FRAMING @ 16" O.C.,
3/4" T&G EXTERIOR GRADE ROOFING
PLYWOOD w/ UNDERLAYMENT AND
ASPHALT SHINGLES TO MATCH EXISTING
(2) 1 3/4" x 12" LVL BEAM @ PERIMETER,
TYPICAL
ROOF RAFTER CLIP BY STRONG-TIE
OR EQUAL
ALUMINUM GUTTER AND
DOWNSPOUT
WOOD TRIM BOARD TO MATCH
EXISTING PROFILE
WOOD TRIM, PAINTED
SCREEN PANEL, w/ 1 1/2" x 1 1/2" WOOD
STOPS, TYPICAL
NEW T&G WOOD CEILING
EXISTING C.I.P. CONCRETE SLAB,
FOUNDATION AND FOOTING 5 1/2"1' - 9 1/4" 1 1/4" 6" 2' - 4"2' - 10"ALIGN FACE OF TRIM w/ EXISTING
C.I.P. CONCRETE WALL
2 1/4" (+,-)
9
12
3/4"
2 x 10 CAP w/ SLOPED TOP
FOR DRAINAGE
EMBED NEW 1/2" ANCHOR BOLT @
48" O.C. MAX. SPACING IN EPOXY
drawn:
checked:
certification:
sheet number:
date: description:
PERMIT ISSUE
sheet title:
consultants:
S. PATRICK KESTNER
ARCHITECT
PH: 317-450-3208
patrickkestner18@gmail.com
8095 BOWLINE DRIVE
INDIANAPOLIS, IN 46236
SPK
SPK
06.08.2020
A1.012020-006The Pacilio Residence14302 Laura Vista Drive, Carmel Indiana 46033Permit Issue
Floor and Roof
Plan, Porch
Section
3/8" = 1'-0"
1
First Floor Dimension Plan
3/8" = 1'-0"
2
Roof Plan
3/4" = 1'-0"
3
Porch Section
09.25.2020 Revision 1
09/29/20